Jim O’bRien
Research Subjects
Jim O’bRien has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Ashish Mittal
Dept. of Cardiac Electrophysiology, St Bartholomew’s Hospital Heart Centre , London EC1A 7BE , UK
1 shared publication - Edward Keelan
Atrial Fibrillation Institute, Mater Private Network , 72 Eccles Street, Dublin 7, D07 RD8P , Ireland
1 shared publication - Gael Jauvert
Atrial Fibrillation Institute, Mater Private Network , 72 Eccles Street, Dublin 7, D07 RD8P , Ireland
1 shared publication - Gábor Széplaki
Mater Private Hospital and Royal College of Surgeons in Ireland , Dublin
1 shared publication John Keaney
Health Sciences Centre, UCD School of Medicine, University of College Dublin , Belfield, Dublin 4, D04 V1W8 , Ireland
1 shared publication- Joseph Galvin
Mater Misericordiae University Hospital , Dublin
1 shared publication
Latest Publications
- Open Access
- 21 December 2023
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 8 (1) , ytad641
Anomalous origin of the left circumflex coronary artery: is surgery required? A case report
Background: Deviations from usual coronary artery anatomy are well documented. The left circumflex artery (LCx) arising from the pulmonary artery is an example of one such deviation which is rarely seen. We present the case of a 26-year-old male with this coronary artery distribution presenting with an episode of ventricular flutter with late gadolinium enhancement and pluri-morphological ventricular arrhythmias. Case summary: A 26-year-old male with a history of cardiac surgery presented to his local hospital with an episode of symptomatic broad-complex tachycardia (BCT). It failed to revert to sinus rhythm following intravenous beta-blockers and amiodarone and required external cardioversion. Subsequently, the patient developed a aspiration pneumonia requiring ICU admission, after which he was transferred to our institute for ongoing cardiac management. Cardiac computed tomography CTA and coronary angiography revealed that the LCx was found to originate from the pulmonary artery. He underwent insertion of a subcutaneous pacemaker and was subsequently discharged. Despite the potential for steal syndrome of viable coronary territories. Multidisciplinary team discussion determined him to be fit for conservative management and not for surgical correction of his anomalous coronary artery anatomy. Discussion: Aberrant coronary artery anatomy can lead to diverse outcomes for patients in terms of both morbidity and mortality. The need for surgery in these situations varies on a case-by-case basis and little research exists to guide decision-making for healthcare professionals. As such there is a need for further study both to guide treatment and to ensure high-quality outcomes for patients with this condition.
- 21 December 2023
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 8 (1) , ytad641
Open AccessAnomalous origin of the left circumflex coronary artery: is surgery required? A case report
Background: Deviations from usual coronary artery anatomy are well documented. The left circumflex artery (LCx) arising from the pulmonary artery is an example of one such deviation which is rarely seen. We present the case of a 26-year-old male with this coronary artery distribution presenting with an episode of ventricular flutter with late gadolinium enhancement and pluri-morphological ventricular arrhythmias. Case summary: A 26-year-old male with a history of cardiac surgery presented to his local hospital with an episode of symptomatic broad-complex tachycardia (BCT). It failed to revert to sinus rhythm following intravenous beta-blockers and amiodarone and required external cardioversion. Subsequently, the patient developed a aspiration pneumonia requiring ICU admission, after which he was transferred to our institute for ongoing cardiac management. Cardiac computed tomography CTA and coronary angiography revealed that the LCx was found to originate from the pulmonary artery. He underwent insertion of a subcutaneous pacemaker and was subsequently discharged. Despite the potential for steal syndrome of viable coronary territories. Multidisciplinary team discussion determined him to be fit for conservative management and not for surgical correction of his anomalous coronary artery anatomy. Discussion: Aberrant coronary artery anatomy can lead to diverse outcomes for patients in terms of both morbidity and mortality. The need for surgery in these situations varies on a case-by-case basis and little research exists to guide decision-making for healthcare professionals. As such there is a need for further study both to guide treatment and to ensure high-quality outcomes for patients with this condition.
- Open Access
- 9 March 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (4) , 1345-1351
The impact of steerable sheath visualization during catheter ablation for atrial fibrillation
Incorporating a steerable sheath that can be visualized using an electroanatomical mapping (EAM) system may allow for more efficient mapping and catheter placement, while reducing radiation exposure, during ablation procedures for atrial fibrillation (AF). This study evaluated fluoroscopy usage and procedure times when a visualizable steerable sheath was used compared with a non-visualizable steerable sheath for catheter ablation for AF. In this retrospective, observational, single-centre study, patients underwent catheter ablation for AF using a steerable sheath that is visualizable using the CARTO EAM (VIZIGO; n = 57) or a non-visualizable steerable sheath (n = 34). The acute procedural success rate was 100%, with no acute complications in either group. Use of the visualizable sheath vs. the non-visualizable sheath was associated with a significantly shorter fluoroscopy time [median (first quartile, third quartile), 3.4 (2.1, 5.4) vs. 5.8 (3.8, 8.6) min; P = 0.003], significantly lower fluoroscopy dose [10.0 (5.0, 20.0) vs. 18.5 (12.3, 34.0) mGy; P = 0.015], and significantly lower dose area product [93.0 (48.0, 197.9) vs. 182.2 (124.5, 355.0) μGy·m2; P = 0.017] but with a significantly longer mapping time [12.0 (9.0, 15.0) vs. 9.0 (7.0, 11.0) min; P = 0.004]. There was no significant difference between the visualizable and non-visualizable sheaths in skin-to-skin time [72.0 (60.0, 82.0) vs. 72.0 (55.5, 80.8) min; P = 0.623]. In this retrospective study, use of a visualizable steerable sheath for catheter ablation of AF significantly reduced radiation exposure vs. a non-visualizable steerable sheath. Although mapping time was longer with the visualizable sheath, the overall procedure time was not increased.
- 9 March 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (4) , 1345-1351
Open AccessThe impact of steerable sheath visualization during catheter ablation for atrial fibrillation
Incorporating a steerable sheath that can be visualized using an electroanatomical mapping (EAM) system may allow for more efficient mapping and catheter placement, while reducing radiation exposure, during ablation procedures for atrial fibrillation (AF). This study evaluated fluoroscopy usage and procedure times when a visualizable steerable sheath was used compared with a non-visualizable steerable sheath for catheter ablation for AF. In this retrospective, observational, single-centre study, patients underwent catheter ablation for AF using a steerable sheath that is visualizable using the CARTO EAM (VIZIGO; n = 57) or a non-visualizable steerable sheath (n = 34). The acute procedural success rate was 100%, with no acute complications in either group. Use of the visualizable sheath vs. the non-visualizable sheath was associated with a significantly shorter fluoroscopy time [median (first quartile, third quartile), 3.4 (2.1, 5.4) vs. 5.8 (3.8, 8.6) min; P = 0.003], significantly lower fluoroscopy dose [10.0 (5.0, 20.0) vs. 18.5 (12.3, 34.0) mGy; P = 0.015], and significantly lower dose area product [93.0 (48.0, 197.9) vs. 182.2 (124.5, 355.0) μGy·m2; P = 0.017] but with a significantly longer mapping time [12.0 (9.0, 15.0) vs. 9.0 (7.0, 11.0) min; P = 0.004]. There was no significant difference between the visualizable and non-visualizable sheaths in skin-to-skin time [72.0 (60.0, 82.0) vs. 72.0 (55.5, 80.8) min; P = 0.623]. In this retrospective study, use of a visualizable steerable sheath for catheter ablation of AF significantly reduced radiation exposure vs. a non-visualizable steerable sheath. Although mapping time was longer with the visualizable sheath, the overall procedure time was not increased.
- Open Access
- 28 February 2021
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 5 (3) , ytab082
Dynamic left ventricular outflow tract gradient resulting from Takotsubo cardiomyopathy ameliorated by intra-aortic balloon pump counterpulsation: a case report
Background: Takotsubo cardiomyopathy is a variant of acute coronary syndrome with characteristic acute left ventricular apical ballooning. Uncommonly, there can be associated left ventricular outflow tract (LVOT) obstruction causing cardiogenic shock refractory to inotropic support. The use of afterload-reducing mechanical support such as intra-aortic balloon pump (IABP) counterpulsation is not routinely employed in instances of this kind. Case summary: In our case report, we describe a 66-year-old female with acute Takotsubo cardiomyopathy and associated LVOT obstruction which failed to respond to high-dose dobutamine and whose clinical trajectory was worsened by fast atrial fibrillation with rapid ventricular response. Within 24 h of admission, the patient had an IABP placed which rapidly improved her haemodynamics. Two days later, IABP was removed and within 6 days of admission, apical ballooning and LVOT obstruction had fully recovered. Conclusion: We recommend early use of mechanical support with IABP counterpulsation to expedite recovery in patients with acute Takotsubo cardiomyopathy with associated LVOT obstruction.
- 28 February 2021
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 5 (3) , ytab082
Open AccessDynamic left ventricular outflow tract gradient resulting from Takotsubo cardiomyopathy ameliorated by intra-aortic balloon pump counterpulsation: a case report
Background: Takotsubo cardiomyopathy is a variant of acute coronary syndrome with characteristic acute left ventricular apical ballooning. Uncommonly, there can be associated left ventricular outflow tract (LVOT) obstruction causing cardiogenic shock refractory to inotropic support. The use of afterload-reducing mechanical support such as intra-aortic balloon pump (IABP) counterpulsation is not routinely employed in instances of this kind. Case summary: In our case report, we describe a 66-year-old female with acute Takotsubo cardiomyopathy and associated LVOT obstruction which failed to respond to high-dose dobutamine and whose clinical trajectory was worsened by fast atrial fibrillation with rapid ventricular response. Within 24 h of admission, the patient had an IABP placed which rapidly improved her haemodynamics. Two days later, IABP was removed and within 6 days of admission, apical ballooning and LVOT obstruction had fully recovered. Conclusion: We recommend early use of mechanical support with IABP counterpulsation to expedite recovery in patients with acute Takotsubo cardiomyopathy with associated LVOT obstruction.