Balakrishna Pamulaparthy
Research Subjects
Research Interests
Balakrishna Pamulaparthy has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Christine Crites
GE Vernova, Houston, TX, USA
1 shared publication Kola Y V Bhargav Reddy
Indian Oil Corporation, Ltd., Mathura, India
1 shared publicationRavindranauth Ramlachan
GE Vernova, Orlando, FL, USA
1 shared publication- Umar Khan
General Electric, Hyderabad, India
1 shared publication
Latest Publications
- 5 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (4) , 6822-6832
Relay-Based Electrical Signature Analysis for Incipient Motor Failure Detection – Field Successes
Unexpected motor failures cause a significant impact to facility operations. To improve personnel safety, minimize unplanned shutdowns, reduce maintenance expenses, and maximize operational revenue, industry worldwide has largely shifted to an enhanced approach to motor maintenance – one that focuses on proactive, preventative maintenance rather than reactionary repair. One prevalent motor failure detection technique used is Electrical Signature Analysis (ESA). While historically cost-prohibitive to apply to smaller machines or less crucial processes, technological advancements have given rise to various much more economical and accessible options to implement ESA technology. This paper will discuss one option: the application of ESA as part of an existing motor protection & control relay. The general concept of ESA will be outlined as well as the benefits ESA incorporated into a protection relay offers. It will also address the types of mechanical faults it can effectively detect. Several case studies will be presented.
- 5 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (4) , 6822-6832
Relay-Based Electrical Signature Analysis for Incipient Motor Failure Detection – Field Successes
Unexpected motor failures cause a significant impact to facility operations. To improve personnel safety, minimize unplanned shutdowns, reduce maintenance expenses, and maximize operational revenue, industry worldwide has largely shifted to an enhanced approach to motor maintenance – one that focuses on proactive, preventative maintenance rather than reactionary repair. One prevalent motor failure detection technique used is Electrical Signature Analysis (ESA). While historically cost-prohibitive to apply to smaller machines or less crucial processes, technological advancements have given rise to various much more economical and accessible options to implement ESA technology. This paper will discuss one option: the application of ESA as part of an existing motor protection & control relay. The general concept of ESA will be outlined as well as the benefits ESA incorporated into a protection relay offers. It will also address the types of mechanical faults it can effectively detect. Several case studies will be presented.
- Open Access
- 3 September 2024
- Published by Institution of Engineering and Technology (IET) in Digital Twins and Applications
- Vol. 1 (1) , 93-102
Hi‐Z fault location identification on low voltage distribution systems using IoT‐based digital twin model computation
Distribution feeders carry and supply power to industrial, commercial and residential loads from the point where sub‐transmission (33 kV level) ends after stepping down to suitable voltages, such as 11 kV and further down to 400/230 V. In recent times, high impedance (Hi‐Z) faults on distribution systems are creating unique challenges to utilities both from operational and safety perspectives. Most of these Hi‐Z faults occur at distribution voltages of 15 kV or below, with the problem being worse at lower voltages. Hi‐Z fault detection technologies emerged and were developed and incorporated on embedded platforms, such as relays, reclosers and sensors, which protect and monitor distribution systems. Although these technologies can detect Hi‐Z fault on feeders, most of them cannot identify the exact location of the fault. Specifically, there is no solution available in literature for detecting Hi‐Z fault location on low voltage (LV) circuits like 3‐phase 4‐wire 400 V distribution network. In this paper, we introduce a novel and a unique algorithm to identify the location of Hi‐Z faults using proposed smart metres IoT data‐based distribution system load flow and digital twin model representation of the network. Furthermore, a case study on the standard 33 bus LV system clearly depicts the functionality of the proposed algorithm.
- 3 September 2024
- Published by Institution of Engineering and Technology (IET) in Digital Twins and Applications
- Vol. 1 (1) , 93-102
Open AccessHi‐Z fault location identification on low voltage distribution systems using IoT‐based digital twin model computation
Distribution feeders carry and supply power to industrial, commercial and residential loads from the point where sub‐transmission (33 kV level) ends after stepping down to suitable voltages, such as 11 kV and further down to 400/230 V. In recent times, high impedance (Hi‐Z) faults on distribution systems are creating unique challenges to utilities both from operational and safety perspectives. Most of these Hi‐Z faults occur at distribution voltages of 15 kV or below, with the problem being worse at lower voltages. Hi‐Z fault detection technologies emerged and were developed and incorporated on embedded platforms, such as relays, reclosers and sensors, which protect and monitor distribution systems. Although these technologies can detect Hi‐Z fault on feeders, most of them cannot identify the exact location of the fault. Specifically, there is no solution available in literature for detecting Hi‐Z fault location on low voltage (LV) circuits like 3‐phase 4‐wire 400 V distribution network. In this paper, we introduce a novel and a unique algorithm to identify the location of Hi‐Z faults using proposed smart metres IoT data‐based distribution system load flow and digital twin model representation of the network. Furthermore, a case study on the standard 33 bus LV system clearly depicts the functionality of the proposed algorithm.
- 15 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-8
An Autonomous Electrical Signature Analysis-Based Method for Faults Monitoring in Industrial Motors
Rotating machines are widely used in Industries, Manufacturing and Oil & Gas plants as a critical component for process availability. The inadvertent failure of these rotating machines causes significant process downtime, incur higher repair costs and loss of revenue. These failures can belong to electrical, thermal or mechanical fault categories. Early detection of all these faults is very much critical for avoiding complete failure of these machines and requires continuous 24/7 online monitoring using sensors or intelligent electronic devices. However, an affordable low cost and efficient online monitoring is a desire to practice specifically for Medium Voltage (MV) machines which has a larger install base. Electrical Signature Analysis (ESA) technology offers such flexibility and requires measuring just current and/or voltage at a motor control panel for machine health diagnosis, unlike Vibration Analysis (VA) requiring installation of sensors and its wiring on the machine. Further, an intelligent, self-reliable and autonomous ESA procedure is required for monitoring the machines due to the lack of ESA standards in practice unlike for VA. This paper proposes a new Autonomous Electrical Signature Analysis (AESA) based measurement technique implemented in Intelligent Electronic Device (IED) i.e. Protection Relay offering 24/7 online monitoring. The proposed technique implemented in Relay not only avoids dependency on standalone ESA hardware but also provides earlier detection of failures using peak and energy magnitudes computation approach at fault frequencies. To validate the proposed method, various tests were performed on the actual 1000 HP and 300 HP motors with/without mechanical faults in a machine repair shop and results are discussed. Performance of the proposed method is also compared with commercially available third-party ESA device results proving the efficacy.
- 15 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-8
An Autonomous Electrical Signature Analysis-Based Method for Faults Monitoring in Industrial Motors
Rotating machines are widely used in Industries, Manufacturing and Oil & Gas plants as a critical component for process availability. The inadvertent failure of these rotating machines causes significant process downtime, incur higher repair costs and loss of revenue. These failures can belong to electrical, thermal or mechanical fault categories. Early detection of all these faults is very much critical for avoiding complete failure of these machines and requires continuous 24/7 online monitoring using sensors or intelligent electronic devices. However, an affordable low cost and efficient online monitoring is a desire to practice specifically for Medium Voltage (MV) machines which has a larger install base. Electrical Signature Analysis (ESA) technology offers such flexibility and requires measuring just current and/or voltage at a motor control panel for machine health diagnosis, unlike Vibration Analysis (VA) requiring installation of sensors and its wiring on the machine. Further, an intelligent, self-reliable and autonomous ESA procedure is required for monitoring the machines due to the lack of ESA standards in practice unlike for VA. This paper proposes a new Autonomous Electrical Signature Analysis (AESA) based measurement technique implemented in Intelligent Electronic Device (IED) i.e. Protection Relay offering 24/7 online monitoring. The proposed technique implemented in Relay not only avoids dependency on standalone ESA hardware but also provides earlier detection of failures using peak and energy magnitudes computation approach at fault frequencies. To validate the proposed method, various tests were performed on the actual 1000 HP and 300 HP motors with/without mechanical faults in a machine repair shop and results are discussed. Performance of the proposed method is also compared with commercially available third-party ESA device results proving the efficacy.