EAEbrahim Fihaid Alsubaiy

Ebrahim Fihaid Alsubaiy

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ebrahim Fihaid Alsubaiy has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Impact of Repeated Steam Sterilization Cycles on the Efficacy of Chairside Adjustment Kits for Polishing Monolithic Multi-Layered Zirconia Dental Restoration Material

    by Mohammed E. Sayed, Honey Lunkad, Enas Jaber Mohana, Sara Ahmad Mesawa, Fatimah Ibrahim Dowairi, Emad Aldeen A. Alharbi, Hayat Ali Hakami, Hossam F. Jokhadar, Nasser M. Alqahtani, Abdullah Hasan Alshehri, et al.

    The Impact of Repeated Steam Sterilization Cycles on the Efficacy of Chairside Adjustment Kits for Polishing Monolithic Multi-Layered Zirconia Dental Restoration Material - Article abstract #944502


  • Open Access

    Impact of Auxiliary Features on Retention of Short Dental Crowns: An In-Vitro Analysis of Box and Groove Preparations

    by Mohammed E. Sayed, Amit Porwal, Bassam Ali Hamdi, Salman Y. Hurubi, Abdulwahab Khalid Hakami, Abdulwahab M. Dighriri, Yaser A. Jad, Saeed M. Alqahtani, Ebrahim Fihaid Alsubaiy, Mohammed A. Alfaifi, et al.

    BACKGROUND Several auxiliary features have been proposed to achieve sustainable retention for short-prepared dental crowns; however, achieving retention is challenging. This study aimed to assess the impact of increased total occlusal convergence and auxiliary preparation factors like box and groove on the retention form of short tooth preparations. MATERIAL AND METHODS Eighty resin machine-milled dies with a height of 3 mm and a deep chamfer margin of 1 mm were prepared to mimic the short-prepared molar. Initially, 2 teeth were prepared following the guidelines, and the total occlusal convergence was kept at 10° and 20°, respectively. Auxiliary features such as the proximal box and buccal groove were prepared on separate 20° dies. Eighty dies were prepared with 10 samples each for 10°, 20°, 20° with proximal box and 20° with buccal groove for zirconia (n=40) and metal crowns (n=40). Cementation was done with glass ionomer luting cement, and a pull-off test was conducted. Data were analyzed using one-way analysis of variance and post hoc fisher least significant difference test (P<0.05). RESULTS The highest mean was observed in the proximal box group with the metal crown (14.59), and the lowest in the group with 20° zirconia crowns (9.12). Within groups, the highest retentive values were found for the 20° taper with proximal box preparation; the lowest was for the 20° taper group. CONCLUSIONS Within the study limitations, it could be concluded that incorporating a proximal box or buccal groove in short tooth preparations with an increased total occlusal convergence improved retentive values.


  • Open Access

    Influence of Chairside Simulated Adjustment (Finishing and Polishing) Protocol and Chlorhexidine Mouthwash Immersion on Color Stability and Translucency of 2 and 3 Preshaded Multilayered Monolithic Zirconia

    by Mohammed E. Sayed, Saurabh Jain, Abrar A. Ageeli, Alhanouf K. Alnajdi, Asma Ahmed Zain, Maimonah Alali, Abdulaziz Ali Ahmed Alhazmi, Ebrahim Fihaid Alsubaiy, Abdullah Hasan Alshehri, Ahid Amer Alshahrani, et al.

    Background: Preshaded monolithic zirconia (MLZ) is reported to have high translucency. This study aimed to assess the effect of chlorhexidine gluconate (ChG) mouthwash on color and translucency parameter (TP) of 2 different preshaded MLZ dental ceramics after clinical adjustment. Material/Methods: Two MLZ disk-shaped specimens [NPM (Nacera Pearl Multi-Shade) (n=72) and CZM (Ceramill Zolid FX Multilayer)] (n=72) were simulated for clinical adjustment, finished, and polished using 2 adjustment kits [recommended kit, third-party kit: Diasynt Plus and SUN (n=12 each)] and later immersed in ChG mouthwash (Avohex) for 2 weeks. Difference in color (Delta E) and TP (Y) were calculated using the CIELab formula after measuring the coordinates (Lab) with a colorimeter. Individual changes in color and TP were assessed on the Clinical acceptance (perceptible) threshold (CAT/CPT) and Translucency perception threshold (TPT), respectively. Differences between the 2 ceramics were assessed using one-way ANOVA and post hoc tests, with all differences considered significant at P<0.05. Results: NPM and CZM differed in color at baseline despite having the same Vita shade combination. Between the 2 preshaded MLZ ceramics, NPM showed significant changes in color when adjusted with a third-party kit. Chlorhexidine produced changes in color and TP that were designated as clinically perceptible (Delta E=1.0 to 3.3) on the CAT/CPT and TPT scales, irrespective of the adjustment kit used. ChG produced the least or no changes in glazed MLZ specimens. Conclusions: ChG mouthwash, whenever prescribed for preshaded MLZ restoration, should be adjusted prior to final glazing to avoid clinical adjustments that adversely affects color and translucency of the restoration.


  • Open Access

    Evaluation of the Milled and Three-Dimensional Digital Manufacturing, 10-Degree and 20-Degree Preparation Taper, Groove and Box Auxiliary Retentive Features, and Conventional and Resin-Based Provisional Cement Type on the Adhesive Failure Stress of 3 mm Short Provisional Crowns

    by Mohammed Sayed, Nandalur Kulashekar Reddy, Naveen R. Reddy, Khurshid A. Mattoo, Yaser Ali Jad, Abdullah Jaber Hakami, Abdulwahab Khalid Hakami, Abdulwahab M. Dighriri, Salman Y. Hurubi, Bassam Ali Hamdi, et al.

    Background: This study evaluated the effects of milling (CADCAM), 3D printing, preparation taper angles (10 -degree and 20 -degree), auxiliary retentive features (groove and box), and provisional cement types (conventional and resin -based) on the adhesive failure stress of 3 -mm short provisional crowns (PC). The research was motivated by the need to understand how digital dentistry technologies impact the retention and durability of provisional crowns. Material/Methods: A total of 160 working models (3D -printed) and PCs [80 milled (CopraTemp)/80 printed (Asiga)] were fabricated from two 10- and 20 -degree typodont master models and two 20 -degree 3D -printed master models (groove and box), simulating a 3 mm high all -ceramic short PC. After provisional cementation with conventional (Kerr TempBond) and resin -based (ProviTemp) cements, 16 subgroups (n=10 each) underwent thermocycling (10 000 cycles; 5-55 degrees C) and pull -off tests on a universal testing machine. Statistical analysis was performed using oneway ANOVA and post hoc Tukey test. Results: Conventional cement failed at lower stress for milled (47.68 to 73.54) and printed (48.40 to 77.91) as compared to resin cement for milled (104.2 to 137.27) and printed (184.85 to 328.84), respectively, with significant differences. Increased taper and groove decreased failure load except for the printed PC/resin cement combination. Use of proximal box preparation increased retention significantly. Except for 20 -degree taper cemented with conventional cement, the differences in auxiliary retentive features for milled and printed provisional crowns were statistically significant at P 0.05 pound. Conclusions: 3D -printed PC, resin -based cement, 10 -degree taper, and proximal box preparation were associated with higher retention than milled, conventional cements, 20 -degree taper, and vertical groove.


  • Open Access

    Fracture resistance of CAD-CAM all-ceramic surveyed crowns with different occlusal rest seat designs

    by Saurabh Chaturvedi, Turki Alqahtani, Saleh Alsolami, Abdulbari Alqahtani, Gotam Das, Ebrahim Alsubaiy

    Chaturvedi S, et al. J Adv Prosthodont. 2021 Feb;13(1):36-45. https://doi.org/10.4047/jap.2021.13.1.36