Jae Hyun Kwon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jae Hyun Kwon has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Young Do Kim
Department of Civil and Environmental Engineering, Myongji University, Yongin 17058, Republic of Korea
8 shared publications - Hwang Jin Young
Gyeongnam Development Institute, Changwon, Korea
2 shared publications - Il-Kyu Kim
Department of Environmental Engineering, Pukyong National University, Busan 48513, Republic of Korea
2 shared publications - Joonwoo Noh
K-water Research Institute
2 shared publications - Do Sung Huh
Inje University
1 shared publication - Dongsu Kim
Civil & Environmental Engineering Dankook University Yongin South Korea
1 shared publication
Latest Publications
- Open Access
- 6 April 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (7) , 4631
Classification Technique of Algae Using Hyperspectral Images of Algae Culture Media
Increases in algal growth have been reported in rivers, reservoirs, and other water resources worldwide, including Korea. Algal overgrowth can result in algal bloom, which has several negative impacts, such as ecosystem degradation and economic losses. Mitigation measures employed in Korea include an algal warning system and survey-based water quality forecast systems. However, these methods are time-consuming and require sample collection from the site. On the other hand, remote sensing techniques that use chlorophyll a are unable to distinguish between different types of algal species. In this paper, we aimed to identify a classification technique based on remote sensing methods that can be used to distinguish between blue-green algae and green algae. We acquired and prepared an algal culture solution and used a hyperspectral sensor to obtain an algae spectrum. Thereafter, we measured the absorption and emission spectra of blue-green and green algae and distinguished them using the instantaneous slope change of the spectrum. The absorption spectra for green algae showed two peaks at 417–437 nm and 661–673 nm, whereas those of blue-green algae showed three peaks at 449–529 nm, 433–437 nm, and 669–677 nm. The results of this study could form a basis for developing mitigation measures for algal overgrowth.
- 6 April 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (7) , 4631
Open AccessClassification Technique of Algae Using Hyperspectral Images of Algae Culture Media
Increases in algal growth have been reported in rivers, reservoirs, and other water resources worldwide, including Korea. Algal overgrowth can result in algal bloom, which has several negative impacts, such as ecosystem degradation and economic losses. Mitigation measures employed in Korea include an algal warning system and survey-based water quality forecast systems. However, these methods are time-consuming and require sample collection from the site. On the other hand, remote sensing techniques that use chlorophyll a are unable to distinguish between different types of algal species. In this paper, we aimed to identify a classification technique based on remote sensing methods that can be used to distinguish between blue-green algae and green algae. We acquired and prepared an algal culture solution and used a hyperspectral sensor to obtain an algae spectrum. Thereafter, we measured the absorption and emission spectra of blue-green and green algae and distinguished them using the instantaneous slope change of the spectrum. The absorption spectra for green algae showed two peaks at 417–437 nm and 661–673 nm, whereas those of blue-green algae showed three peaks at 449–529 nm, 433–437 nm, and 669–677 nm. The results of this study could form a basis for developing mitigation measures for algal overgrowth.
- Open Access
Comparison of Optimal Machine Learning Algorithms for Early Detection of Unknown Hazardous Chemicals in Rivers Using Sensor Monitoring Data
Water environment pollution due to chemical spills occurs constantly worldwide. When a chemical accident occurs, a quick initial response is most important. In previous studies, samples collected from chemical accident sites were subjected to laboratory-based precise analysis or predictive research through modeling. These results can be used to formulate appropriate responses in the event of chemical accidents; however, there are limitations to this process. For the initial response, it is important to quickly acquire information on chemicals leaked from the site. In this study, pH and electrical conductivity (EC), which are easy to measure in the field, were applied. In addition, 13 chemical substances were selected, and pH and EC data for each were established according to concentration change. The obtained data were applied to machine learning algorithms, including decision trees, random forests, gradient boosting, and XGBoost (XGB), to determine the chemical substances present. Through performance evaluation, the boosting method was found to be sufficient, and XGB was the most suitable algorithm for chemical substance detection.
Open AccessComparison of Optimal Machine Learning Algorithms for Early Detection of Unknown Hazardous Chemicals in Rivers Using Sensor Monitoring Data
Water environment pollution due to chemical spills occurs constantly worldwide. When a chemical accident occurs, a quick initial response is most important. In previous studies, samples collected from chemical accident sites were subjected to laboratory-based precise analysis or predictive research through modeling. These results can be used to formulate appropriate responses in the event of chemical accidents; however, there are limitations to this process. For the initial response, it is important to quickly acquire information on chemicals leaked from the site. In this study, pH and electrical conductivity (EC), which are easy to measure in the field, were applied. In addition, 13 chemical substances were selected, and pH and EC data for each were established according to concentration change. The obtained data were applied to machine learning algorithms, including decision trees, random forests, gradient boosting, and XGBoost (XGB), to determine the chemical substances present. Through performance evaluation, the boosting method was found to be sufficient, and XGB was the most suitable algorithm for chemical substance detection.
- Open Access
- 1 December 2022
- Published by Korean Society of Environmental Engineering in Journal of Korean Society of Environmental Engineers
- Vol. 44 (12) , 569-577
The Estimation of Blue-green algae Cell Count and Phycocyanin Concentration using Fluorescent Concentration analyzer
Objectives:The purpose of this study is to provide basic data for the development of a rapid and easy to measure alternative indicator for estimating the number of cyanobacteria cells in the field.Methods:Phycocyanin, algal cell number, and water quality items were measured at the left, middle, and right points of Maery Bridge near the Mulgeum and Maery algae monitoring network located downstream of the Nakdong River. The phycocyanin concentration(PC) was measured in the field using the LISST-HAB sensor, which is a fluorescence concentration analyzer, and comparative analysis was performed with the number of algal cells by algae species.Results and Discussion:As a limiting factor for blue-green algae occurrence, the correlation coefficient (r) between T-P and Blue-green algae (BGA) was 0.58 (≥0.3). Phycocyanin and Blue-green algae showed a high significant correlation at 0.96 (≥0.3). Prob (F-statistics) of the blue-green algae cell count estimation formula using phycocyanin was less than 0.05, showing a significant result. The estimation formula was estimated BGA(cells/mL) = 326.95×PC+50,484. As a result of the analysis of the predicted and measured values of Blue-green algae, r2 was 0.988, indicating a high coefficient of determination and 92.5% accuracy.Conclusion: The correlation analysis with the number of cyanobacteria showed a high significant correlation with phycocyanin of 0.96 (≥0.3), followed by T-P, a limiting factor for the occurrence of cyanobacteria, of 0.58 (≥0.3) indicating a significant correlation. In addition, the formula for estimating the number of blue-green algae cells using phycocyanin was found to be BGA (cells/mL)=326.95×PC+50,484 in which r2 was 0.927, and Prob (F-statistics) was less than 0.05. As a result of analyzing the predicted and measured values of cyanobacteria cell numbers, r2 was 0.988, indicating a high coefficient of determination, with accuracy of 92.5%. Through this results, it reveals that the number of cyanobacteria cells can be estimated using the sensor of the fluorescence concentration analyzer at the target point by substituting the phycocyanin concentration into the blue-green algae cell number estimation formula.
- 1 December 2022
- Published by Korean Society of Environmental Engineering in Journal of Korean Society of Environmental Engineers
- Vol. 44 (12) , 569-577
Open AccessThe Estimation of Blue-green algae Cell Count and Phycocyanin Concentration using Fluorescent Concentration analyzer
Objectives:The purpose of this study is to provide basic data for the development of a rapid and easy to measure alternative indicator for estimating the number of cyanobacteria cells in the field.Methods:Phycocyanin, algal cell number, and water quality items were measured at the left, middle, and right points of Maery Bridge near the Mulgeum and Maery algae monitoring network located downstream of the Nakdong River. The phycocyanin concentration(PC) was measured in the field using the LISST-HAB sensor, which is a fluorescence concentration analyzer, and comparative analysis was performed with the number of algal cells by algae species.Results and Discussion:As a limiting factor for blue-green algae occurrence, the correlation coefficient (r) between T-P and Blue-green algae (BGA) was 0.58 (≥0.3). Phycocyanin and Blue-green algae showed a high significant correlation at 0.96 (≥0.3). Prob (F-statistics) of the blue-green algae cell count estimation formula using phycocyanin was less than 0.05, showing a significant result. The estimation formula was estimated BGA(cells/mL) = 326.95×PC+50,484. As a result of the analysis of the predicted and measured values of Blue-green algae, r2 was 0.988, indicating a high coefficient of determination and 92.5% accuracy.Conclusion: The correlation analysis with the number of cyanobacteria showed a high significant correlation with phycocyanin of 0.96 (≥0.3), followed by T-P, a limiting factor for the occurrence of cyanobacteria, of 0.58 (≥0.3) indicating a significant correlation. In addition, the formula for estimating the number of blue-green algae cells using phycocyanin was found to be BGA (cells/mL)=326.95×PC+50,484 in which r2 was 0.927, and Prob (F-statistics) was less than 0.05. As a result of analyzing the predicted and measured values of cyanobacteria cell numbers, r2 was 0.988, indicating a high coefficient of determination, with accuracy of 92.5%. Through this results, it reveals that the number of cyanobacteria cells can be estimated using the sensor of the fluorescence concentration analyzer at the target point by substituting the phycocyanin concentration into the blue-green algae cell number estimation formula.
- Open Access
Experimental Study on the Detection of Hazardous Chemicals Using Alternative Sensors in the Water Environment
Chemical accidents in rivers may be triggered by natural or anthropogenic causes and refer to the flow of large quantities of hazardous chemicals into rivers. In South Korea, domestic water is sourced from large rivers, such as the Nakdong River. However, owing to rapid industrialization, industrial facilities have become heavily concentrated in the middle and upper reaches of the Nakdong River. Therefore, severe problems could arise if harmful chemicals are leaked from industrial facilities into the river, and this contaminated river water is supplied to cities. Quantitative evaluation based on instrumental analysis during chemical accidents and prediction research based on modeling is actively being conducted however, research on the initial response is insufficient. Therefore, in this study, the variations in pH and EC were analyzed according to their chemical concentrations for seven chemicals. These seven chemicals are designated accident-preparedness substances that frequently cause chemical spills in South Korea. Additionally, we evaluated the possibility of identifying unknown substances by comparing the variations in pH and EC and statistics while diluting unknown substances. Thus, the potential of pH and EC as alternative indicators for detecting and identifying chemicals was evaluated in this study. NaF, NH4HF2, NaCN, and NH4OH were classified by comparing their spatial distributions in a pH-EC relation curve. However, H2SO4, HCl, and SOCl2 showed similar spatial distributions in the pH-EC curves and were difficult to identify. The results of this study provide information for chemical detection and identification using alternative sensors that permit easy and rapid field measurements in the event of a chemical spill and could be used as preliminary data for rapidly responding to accidents.
Open AccessExperimental Study on the Detection of Hazardous Chemicals Using Alternative Sensors in the Water Environment
Chemical accidents in rivers may be triggered by natural or anthropogenic causes and refer to the flow of large quantities of hazardous chemicals into rivers. In South Korea, domestic water is sourced from large rivers, such as the Nakdong River. However, owing to rapid industrialization, industrial facilities have become heavily concentrated in the middle and upper reaches of the Nakdong River. Therefore, severe problems could arise if harmful chemicals are leaked from industrial facilities into the river, and this contaminated river water is supplied to cities. Quantitative evaluation based on instrumental analysis during chemical accidents and prediction research based on modeling is actively being conducted however, research on the initial response is insufficient. Therefore, in this study, the variations in pH and EC were analyzed according to their chemical concentrations for seven chemicals. These seven chemicals are designated accident-preparedness substances that frequently cause chemical spills in South Korea. Additionally, we evaluated the possibility of identifying unknown substances by comparing the variations in pH and EC and statistics while diluting unknown substances. Thus, the potential of pH and EC as alternative indicators for detecting and identifying chemicals was evaluated in this study. NaF, NH4HF2, NaCN, and NH4OH were classified by comparing their spatial distributions in a pH-EC relation curve. However, H2SO4, HCl, and SOCl2 showed similar spatial distributions in the pH-EC curves and were difficult to identify. The results of this study provide information for chemical detection and identification using alternative sensors that permit easy and rapid field measurements in the event of a chemical spill and could be used as preliminary data for rapidly responding to accidents.
- Open Access
- 1 March 2016
- Published by Elsevier in Desalination and Water Treatment
- Vol. 57 (11) , 5138-5145
Applications of electrochemical ferrate(VI) for degradation of trichloroethylene in the aqueous phase
The degradation of trichloroethylene (TCE) by ferrate generated from electrochemical synthesis has been studied. The degradation efficiency of TCE in aqueous solution was observed at various pH (3, 7, 11), ferrate dosages (5, 8, 11, 13, 15 and 17 mg/L), and temperature (10, 25, 35 and 50°C). The experimental results showed that TCE removal efficiency increased with an increase in ferrate dosages. For the effect of pH, the highest value of kapp, 893.54 M−1s−1, was observed at pH 7. The TCE degradation pathways have been proposed based on the intermediate products such as ethyl chloride, dichloroethylene, chloroform, 1,1-dichloropropene, trichloroacetic acid and trichloroethane, and Cl− was identified as an end product.
- 1 March 2016
- Published by Elsevier in Desalination and Water Treatment
- Vol. 57 (11) , 5138-5145
Open AccessApplications of electrochemical ferrate(VI) for degradation of trichloroethylene in the aqueous phase
The degradation of trichloroethylene (TCE) by ferrate generated from electrochemical synthesis has been studied. The degradation efficiency of TCE in aqueous solution was observed at various pH (3, 7, 11), ferrate dosages (5, 8, 11, 13, 15 and 17 mg/L), and temperature (10, 25, 35 and 50°C). The experimental results showed that TCE removal efficiency increased with an increase in ferrate dosages. For the effect of pH, the highest value of kapp, 893.54 M−1s−1, was observed at pH 7. The TCE degradation pathways have been proposed based on the intermediate products such as ethyl chloride, dichloroethylene, chloroform, 1,1-dichloropropene, trichloroacetic acid and trichloroethane, and Cl− was identified as an end product.
- Open Access
- 1 January 2014
- Published by Elsevier in KSCE Journal of Civil Engineering
- Vol. 18 (1) , 73-80
Hydrodynamic and water quality modeling for gate operation: A case study for the Seonakdong River basin in Korea
- 1 January 2014
- Published by Elsevier in KSCE Journal of Civil Engineering
- Vol. 18 (1) , 73-80
Open AccessHydrodynamic and water quality modeling for gate operation: A case study for the Seonakdong River basin in Korea
- Open Access
- 1 January 2014
- Published by Elsevier in KSCE Journal of Civil Engineering
- Vol. 18 (1) , 81-85
Removal of phosphorus and coliforms from secondary effluent using ferrate(VI)
- 1 January 2014
- Published by Elsevier in KSCE Journal of Civil Engineering
- Vol. 18 (1) , 81-85
Open AccessRemoval of phosphorus and coliforms from secondary effluent using ferrate(VI)
- 1 January 2009
- Published by Springer Nature
- p. 705-709
A Study on Water Quality Modeling of Seonakdong River Using CE-QUAL-RIV1
- 1 January 2009
- Published by Springer Nature
- p. 705-709
A Study on Water Quality Modeling of Seonakdong River Using CE-QUAL-RIV1
- 1 November 2005
- Published by IWA Publishing in Water Science & Technology
- Vol. 52 (10-11) , 201-210
A pilot study on accelerated sludge degradation by a high-concentration membrane bioreactor coupled with sludge pretreatment
A new sludge treatment process combining a high MLSS membrane bioreactor with sludge pretreatment techniques was studied in pilot-scale experiments. The membrane bioreactor (MBR) was adopted for high efficiency aerobic digestion. The combination of alkaline-ozone treatment of the mixed liquor in the MBR reactor accelerated the biodegradation process by enhancing biodegradability of the sludge. The hydraulic retention time (HRT) of the reactor was set as 3.1 days and the DO level was 1mg/L on average. After 5 months of operation, the accumulative total solids reduction was more than 70%. Removal efficiency of volatile solids and non-volatile solids were 76% and 54%, respectively. It was found that a considerable portion of the non-volatile solids was dissolved into ions and then flushed out with the effluent. Also, about 41% and 28% of T-N and T-P in the raw sludge were removed although no biological nutrient removal process was adopted. The experiment was run smoothly without significant membrane fouling, even at the relatively high levels of MLSS concentration (11,000–25,000mg/L). It is concluded that the newly proposed process can significantly increase the sludge reduction efficiency with much shorter retention times.
- 1 November 2005
- Published by IWA Publishing in Water Science & Technology
- Vol. 52 (10-11) , 201-210
A pilot study on accelerated sludge degradation by a high-concentration membrane bioreactor coupled with sludge pretreatment
A new sludge treatment process combining a high MLSS membrane bioreactor with sludge pretreatment techniques was studied in pilot-scale experiments. The membrane bioreactor (MBR) was adopted for high efficiency aerobic digestion. The combination of alkaline-ozone treatment of the mixed liquor in the MBR reactor accelerated the biodegradation process by enhancing biodegradability of the sludge. The hydraulic retention time (HRT) of the reactor was set as 3.1 days and the DO level was 1mg/L on average. After 5 months of operation, the accumulative total solids reduction was more than 70%. Removal efficiency of volatile solids and non-volatile solids were 76% and 54%, respectively. It was found that a considerable portion of the non-volatile solids was dissolved into ions and then flushed out with the effluent. Also, about 41% and 28% of T-N and T-P in the raw sludge were removed although no biological nutrient removal process was adopted. The experiment was run smoothly without significant membrane fouling, even at the relatively high levels of MLSS concentration (11,000–25,000mg/L). It is concluded that the newly proposed process can significantly increase the sludge reduction efficiency with much shorter retention times.