Katie Garland
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Katie Garland has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Damir B. Matic
Division of Plastic and Reconstructive Surgery, University of Western Ontario, London, Canada
2 shared publications Damir Matic
Division of Plastic Surgery, Schulich School of Medicine & Dentistry, Western University, London, ON, Canada; Division of Pediatric Surgery, Schulich School of Medicine & Dentistry, Western University, London, ON, Canada; Cleft Lip and Palate Program, Thames Valley Children's Centre, London, ON, Canada
2 shared publicationsAnne Dworschak-Stokan
Speech Language Pathologist, Thames Valley Children's Centre, London, ON, Canada
1 shared publication- Brendan Douglas McNeely
Division of Otolaryngology Head & Neck Surgery, University of British Columbia, Vancouver, BC, Canada
1 shared publication Luc Dubois
Division of Vascular Surgery, Department of Surgery, Western University, London, Ontario, Canada
1 shared publicationMichelle Coyle
Schulich School of Medicine and Dentistry, Western University, London, ON, Canada
1 shared publication
Latest Publications
- 24 June 2022
- Published by Elsevier in Journal of Plastic, Reconstructive & Aesthetic Surgery
- Vol. 75 (10) , 3813-3816
Patient and surgical factors that affect the development of velopharyngeal insufficiency
- 24 June 2022
- Published by Elsevier in Journal of Plastic, Reconstructive & Aesthetic Surgery
- Vol. 75 (10) , 3813-3816
Patient and surgical factors that affect the development of velopharyngeal insufficiency
- 13 June 2022
- Published by SAGE Publications in The Cleft Palate Craniofacial Journal
- Vol. 60 (11) , 1359-1365
Ten-Year Cephalometric Comparison of Patients With Cleft Palate who Received Treatment With Active or Passive Pre-surgical Orthopedic Devices
Background: Pre-surgical orthopedic (PSO) devices can be used in the management of patient with cleft lip/palate (CL/P) to narrow the alveolar gap (AG) prior to lip surgery. There are few studies comparing these 2 devices. The objective of this work was to compare the effects of active and passive PSO devices on facial growth in a single surgeon's cohort of patients with CL/P over a 10-year period. Methods: A retrospective review of all patients with CL/P in a single surgeon's practice from 2002 to 2018 was performed. Preoperative measurements of AG size were done using electronic calipers on patient molds. Patient radiographs were taken at 5 and 10 years of age and cephalometric landmarks were plotted using specialized software. Independent sample t-tests were used to compare means for maxillary, mandibular, vertical, and dento-alveolar growth parameters. Results: Twenty patients with an active device and 23 patients with a passive device were included. No differences were observed in the basic demographic information between the two groups. At the time of lip repair, patients with a passive device had significantly larger horizontal AGs ( P < .01), but by the time of palate repair, there was no difference between the two groups ( P = .94). There was no significant difference in any growth measurements between the active and passive device groups at 5 and 10 years. Conclusions: Despite closing the AG more quickly, patients treated with an active device have no significant difference in facial growth at 10 years compared to patients treated with a passive device.
- 13 June 2022
- Published by SAGE Publications in The Cleft Palate Craniofacial Journal
- Vol. 60 (11) , 1359-1365
Ten-Year Cephalometric Comparison of Patients With Cleft Palate who Received Treatment With Active or Passive Pre-surgical Orthopedic Devices
Background: Pre-surgical orthopedic (PSO) devices can be used in the management of patient with cleft lip/palate (CL/P) to narrow the alveolar gap (AG) prior to lip surgery. There are few studies comparing these 2 devices. The objective of this work was to compare the effects of active and passive PSO devices on facial growth in a single surgeon's cohort of patients with CL/P over a 10-year period. Methods: A retrospective review of all patients with CL/P in a single surgeon's practice from 2002 to 2018 was performed. Preoperative measurements of AG size were done using electronic calipers on patient molds. Patient radiographs were taken at 5 and 10 years of age and cephalometric landmarks were plotted using specialized software. Independent sample t-tests were used to compare means for maxillary, mandibular, vertical, and dento-alveolar growth parameters. Results: Twenty patients with an active device and 23 patients with a passive device were included. No differences were observed in the basic demographic information between the two groups. At the time of lip repair, patients with a passive device had significantly larger horizontal AGs ( P < .01), but by the time of palate repair, there was no difference between the two groups ( P = .94). There was no significant difference in any growth measurements between the active and passive device groups at 5 and 10 years. Conclusions: Despite closing the AG more quickly, patients treated with an active device have no significant difference in facial growth at 10 years compared to patients treated with a passive device.
- Open Access
- 8 March 2021
- Published by SAGE Publications in The Cleft Palate Craniofacial Journal
- Vol. 59 (2) , 156-165
Systematic Review of the Long-Term Effects of Presurgical Orthopedic Devices on Patient Outcomes
Objective: To perform a systematic review of the literature to identify the long-term effects of presurgical orthopedic (PSO) device use on patient outcomes. Design: A comprehensive literature review of Embase and Ovid databases was performed to identify all English-language publications related to unilateral cleft lip and palate, presurgical devices, and patient outcomes. Studies were excluded if they did not report patient outcomes beyond 2 years of age, did not describe the use of a PSO device, were case reports (n < 10), or were purely descriptive studies. Main Outcome Measures: Reported patient outcomes following the use of PSO devices. Results: Following a review of all articles by 2 independent reviews, 30 articles were selected for inclusion. Overall, there was no reported consensus as to the long-term effects of PSO devices. Furthermore, this study identified that only 10% of published research controlled for confounding factors that could influence the reported results. Confounding factors that were identified included different operating surgeon, different surgical protocols, and different rates of revision surgeries. Conclusions: Overall, this systematic review identified 2 important conclusions. Firstly, there is no consensus in the literature about the long-term effects of PSO devices on long-term patient outcomes. Secondly, research in this domain is limited by confounding factors that influence the applicability of the reported results.
- 8 March 2021
- Published by SAGE Publications in The Cleft Palate Craniofacial Journal
- Vol. 59 (2) , 156-165
Open AccessSystematic Review of the Long-Term Effects of Presurgical Orthopedic Devices on Patient Outcomes
Objective: To perform a systematic review of the literature to identify the long-term effects of presurgical orthopedic (PSO) device use on patient outcomes. Design: A comprehensive literature review of Embase and Ovid databases was performed to identify all English-language publications related to unilateral cleft lip and palate, presurgical devices, and patient outcomes. Studies were excluded if they did not report patient outcomes beyond 2 years of age, did not describe the use of a PSO device, were case reports (n < 10), or were purely descriptive studies. Main Outcome Measures: Reported patient outcomes following the use of PSO devices. Results: Following a review of all articles by 2 independent reviews, 30 articles were selected for inclusion. Overall, there was no reported consensus as to the long-term effects of PSO devices. Furthermore, this study identified that only 10% of published research controlled for confounding factors that could influence the reported results. Confounding factors that were identified included different operating surgeon, different surgical protocols, and different rates of revision surgeries. Conclusions: Overall, this systematic review identified 2 important conclusions. Firstly, there is no consensus in the literature about the long-term effects of PSO devices on long-term patient outcomes. Secondly, research in this domain is limited by confounding factors that influence the applicability of the reported results.