Matthew V. Dipane
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Matthew V. Dipane has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
- Edward J. McPherson
Department of Orthopaedic Surgery, University of California Los Angeles, Los Angeles, CA 90404, USA
12 shared publications - Madhav Chowdhry
Department of Continuing Education, Kellogg College University of Oxford Oxford UK
7 shared publications - Alexandra I. Stavrakis
Department of Orthopaedic Surgery, University of California Los Angeles, Los Angeles, CA, USA
4 shared publications Andrew J. Wassef
Long Beach Lakewood Orthopedic Institute, Long Beach, CA 90808, USA
3 shared publications- Paul Stoodley
Department of Microbial Infection and Immunity, The Ohio State University, Columbus, OH 43210, USA
2 shared publications - Adolfo Hernandez
Department of Orthopaedic Surgery, David Geffen School of Medicine at UCLA, Santa Monica, California
1 shared publication
Latest Publications
- Open Access
- 15 August 2025
- Published by Copernicus GmbH in Journal of Bone and Joint Infection
- Vol. 10  (4) , 309-315
In vitro mixing formulas for antimicrobial calcium sulfate beads for point-of-care applications: an additional update to formulas
This communication updates a previous report describing mixing formulas for antimicrobial agents into a synthetic, dissolvable calcium sulfate (CaSO4) product to create small-sized beads (3–6 mm). Antimicrobial-loaded calcium sulfate (ALCS) beads are applied as surgeon-directed, point-of-care use in cases of periprosthetic joint infection (PJI), fracture-related infection (FRI), and other related bone site infections. This treatment technique has been utilized more frequently in the last decade to combat microbial musculoskeletal infections (MSIs). With the widening spectrum of identified microbes encountered in MSIs, we have provided additional antimicrobial formulas to be used singularly and in combination using our in vitro mixing lab protocol previously published. This communication reports 20 additional agents/combinations tested using our protocol to arrive at a standard mix formula or, when necessary, a modified mixing method. Most mixing formulas derived were for antimicrobials effective against fungi and mycobacterium species.
- 15 August 2025
- Published by Copernicus GmbH in Journal of Bone and Joint Infection
- Vol. 10  (4) , 309-315
Open AccessIn vitro mixing formulas for antimicrobial calcium sulfate beads for point-of-care applications: an additional update to formulas
This communication updates a previous report describing mixing formulas for antimicrobial agents into a synthetic, dissolvable calcium sulfate (CaSO4) product to create small-sized beads (3–6 mm). Antimicrobial-loaded calcium sulfate (ALCS) beads are applied as surgeon-directed, point-of-care use in cases of periprosthetic joint infection (PJI), fracture-related infection (FRI), and other related bone site infections. This treatment technique has been utilized more frequently in the last decade to combat microbial musculoskeletal infections (MSIs). With the widening spectrum of identified microbes encountered in MSIs, we have provided additional antimicrobial formulas to be used singularly and in combination using our in vitro mixing lab protocol previously published. This communication reports 20 additional agents/combinations tested using our protocol to arrive at a standard mix formula or, when necessary, a modified mixing method. Most mixing formulas derived were for antimicrobials effective against fungi and mycobacterium species.
- Open Access
- 19 June 2025
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 107  (16) , 1818-1824
Comparing the in Vitro Efficacy of Commonly Used Surgical Irrigants for the Treatment of Implant-Associated Infections
Background: Implant-associated infections (IAIs) require aggressive debridement to eliminate microbial bioburden. The use of irrigants may improve microbial killing during debridement. This study compared the efficacy of surgical irrigants in vitro against Staphylococcus aureus alone and in combination with Candida albicans, in both planktonic and biofilm states. Methods: Full-strength Dakin’s solution, 0.35% povidone-iodine (PI), 10% PI, 3% hydrogen peroxide (HP), a 1:1 combination of 10% PI and 3% HP (PI + HP), Irrisept, XPERIENCE, Bactisure, and normal saline solution were tested. For planktonic testing, 1 × 106 colony-forming units (CFUs) of S. aureus and C. albicans were utilized, and biofilms were grown in these conditions on 0.8 × 10-mm titanium alloy Kirschner wires for 48 hours. Killing assays were performed using 5-minute dwell times. Success was defined by complete eradication of planktonic or biofilm CFUs. Results: PI + HP and Bactisure were the only irrigants to eradicate S. aureus in both planktonic and biofilm states. PI + HP was the only irrigant to eradicate polymicrobial S. aureus + C. albicans bioburden in both states. Conclusions: PI + HP and Bactisure were superior irrigants against S. aureus, eliminating it in planktonic and biofilm states. PI + HP was the only irrigant to eradicate polymicrobial S. aureus + C. albicans bioburden in both states. In vivo studies are needed to evaluate the clinical effectiveness. Clinical Relevance: Surgical irrigants have variable efficacy in eradicating microbes depending on their state of existence (planktonic versus biofilm). In this study, the most effective eradication of polymicrobial S. aureus + C. albicans bioburden was a 1:1 combination of 10% PI and 3% HP, which is of nominal cost.
- 19 June 2025
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 107  (16) , 1818-1824
Open AccessComparing the in Vitro Efficacy of Commonly Used Surgical Irrigants for the Treatment of Implant-Associated Infections
Background: Implant-associated infections (IAIs) require aggressive debridement to eliminate microbial bioburden. The use of irrigants may improve microbial killing during debridement. This study compared the efficacy of surgical irrigants in vitro against Staphylococcus aureus alone and in combination with Candida albicans, in both planktonic and biofilm states. Methods: Full-strength Dakin’s solution, 0.35% povidone-iodine (PI), 10% PI, 3% hydrogen peroxide (HP), a 1:1 combination of 10% PI and 3% HP (PI + HP), Irrisept, XPERIENCE, Bactisure, and normal saline solution were tested. For planktonic testing, 1 × 106 colony-forming units (CFUs) of S. aureus and C. albicans were utilized, and biofilms were grown in these conditions on 0.8 × 10-mm titanium alloy Kirschner wires for 48 hours. Killing assays were performed using 5-minute dwell times. Success was defined by complete eradication of planktonic or biofilm CFUs. Results: PI + HP and Bactisure were the only irrigants to eradicate S. aureus in both planktonic and biofilm states. PI + HP was the only irrigant to eradicate polymicrobial S. aureus + C. albicans bioburden in both states. Conclusions: PI + HP and Bactisure were superior irrigants against S. aureus, eliminating it in planktonic and biofilm states. PI + HP was the only irrigant to eradicate polymicrobial S. aureus + C. albicans bioburden in both states. In vivo studies are needed to evaluate the clinical effectiveness. Clinical Relevance: Surgical irrigants have variable efficacy in eradicating microbes depending on their state of existence (planktonic versus biofilm). In this study, the most effective eradication of polymicrobial S. aureus + C. albicans bioburden was a 1:1 combination of 10% PI and 3% HP, which is of nominal cost.
- Open Access
- 25 February 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14  (5) , 1531
Antibiotic-Loaded Calcium Sulphate Beads for Treatment of Acute Periprosthetic Joint Infection in Total Knee Arthroplasty: Results Based on Risk Stratification
Background: A post-operative or late acute periprosthetic joint infection (PJI) after Total Knee Arthroplasty (TKA) requires a protocol of aggressive joint Debridement, modular implant Exchange, Component Retention, and post-operative Antimicrobial therapy (DECRA). Recently, the novel addition of intra-articular Antimicrobial Loaded Calcium Sulphate (AL-CaSO4) beads during DECRA has been utilized to improve microbial eradication. This study reviews a consecutive series of DECRA TKA procedures with AL-CaSO4 beads with a standardized antimicrobial regimen. We hypothesize AL-CaSO4 beads will not improve infection-free implant survival in compromised hosts and limbs. Methods: This consecutive series included DECRA procedures for acute post-operative or late hematogenous PJI-TKA (primary and revision) detected within 4 weeks. One gram of vancomycin powder and 240 mg of liquid tobramycin were added to 10 cc of CaSO4 powder to create 3.0 and 4.8 mm beads delivered into the joint at closure. All patients were risk stratified according to McPherson Staging and followed for a minimum of 1 year. Results: Forty-two patients were studied. The infection-free success rate of DECRA with AL-CaSO4 was 62% (26/42) at 1 year. Average bead volume per case was 18.6 cc (range = 10–40 cc). McPherson Host stage and Limb Score were found to be significantly correlated with the success of the DECRA (p < 0.05). The success rate was highest in A-hosts (87.5%), declining to 50% in B-hosts, and 25% in C-hosts. Similarly, the success rate was highest for patients with Limb score 1 (100%), declining to 58.6% with Limb score 2, and 20% with Limb score 3. Importantly, a previous episode of infection in the affected joint was associated with significantly increased failure (p = 0.000025). Conclusions: This study reports an overall higher infection-free success rate of DECRA using AL-CaSO4 beads compared to the current literature. Antibiotic beads provide an advantage in selected groups that include A or B hosts and Limb scores of 1 or 2. In C-hosts, where the immune system is weak, or Limb score 3, where the wound is compromised and leaks, antibiotic beads do not improve success. Importantly, DECRAs should not be considered curative with a prior history of joint infection. In these difficult circumstances, one should consider an exchange protocol.
- 25 February 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14  (5) , 1531
Open AccessAntibiotic-Loaded Calcium Sulphate Beads for Treatment of Acute Periprosthetic Joint Infection in Total Knee Arthroplasty: Results Based on Risk Stratification
Background: A post-operative or late acute periprosthetic joint infection (PJI) after Total Knee Arthroplasty (TKA) requires a protocol of aggressive joint Debridement, modular implant Exchange, Component Retention, and post-operative Antimicrobial therapy (DECRA). Recently, the novel addition of intra-articular Antimicrobial Loaded Calcium Sulphate (AL-CaSO4) beads during DECRA has been utilized to improve microbial eradication. This study reviews a consecutive series of DECRA TKA procedures with AL-CaSO4 beads with a standardized antimicrobial regimen. We hypothesize AL-CaSO4 beads will not improve infection-free implant survival in compromised hosts and limbs. Methods: This consecutive series included DECRA procedures for acute post-operative or late hematogenous PJI-TKA (primary and revision) detected within 4 weeks. One gram of vancomycin powder and 240 mg of liquid tobramycin were added to 10 cc of CaSO4 powder to create 3.0 and 4.8 mm beads delivered into the joint at closure. All patients were risk stratified according to McPherson Staging and followed for a minimum of 1 year. Results: Forty-two patients were studied. The infection-free success rate of DECRA with AL-CaSO4 was 62% (26/42) at 1 year. Average bead volume per case was 18.6 cc (range = 10–40 cc). McPherson Host stage and Limb Score were found to be significantly correlated with the success of the DECRA (p < 0.05). The success rate was highest in A-hosts (87.5%), declining to 50% in B-hosts, and 25% in C-hosts. Similarly, the success rate was highest for patients with Limb score 1 (100%), declining to 58.6% with Limb score 2, and 20% with Limb score 3. Importantly, a previous episode of infection in the affected joint was associated with significantly increased failure (p = 0.000025). Conclusions: This study reports an overall higher infection-free success rate of DECRA using AL-CaSO4 beads compared to the current literature. Antibiotic beads provide an advantage in selected groups that include A or B hosts and Limb scores of 1 or 2. In C-hosts, where the immune system is weak, or Limb score 3, where the wound is compromised and leaks, antibiotic beads do not improve success. Importantly, DECRAs should not be considered curative with a prior history of joint infection. In these difficult circumstances, one should consider an exchange protocol.
- Open Access
- 22 January 2024
- Published by Elsevier in Arthroplasty Today
- Vol. 25, 101302
Point-of-Care Coating of Revision Femoral Stems With Antibiotic-Loaded Calcium Sulfate: Reduction in Infection After 2nd Stage Reimplantation but Not With Aseptic Revisions
- 22 January 2024
- Published by Elsevier in Arthroplasty Today
- Vol. 25, 101302
Open AccessPoint-of-Care Coating of Revision Femoral Stems With Antibiotic-Loaded Calcium Sulfate: Reduction in Infection After 2nd Stage Reimplantation but Not With Aseptic Revisions
- Open Access
- 1 December 2022
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 3  (12) , 991-997
Biphasic bone graft substitute in revision total hip arthroplasty with significant acetabular bone defects
Aims: Large acetabular bone defects encountered in revision total hip arthroplasty (THA) are challenging to restore. Metal constructs for structural support are combined with bone graft materials for restoration. Autograft is restricted due to limited volume, and allogenic grafts have downsides including cost, availability, and operative processing. Bone graft substitutes (BGS) are an attractive alternative if they can demonstrate positive remodelling. One potential product is a biphasic injectable mixture (Cerament) that combines a fast-resorbing material (calcium sulphate) with the highly osteoconductive material hydroxyapatite. This study reviews the application of this biomaterial in large acetabular defects. Methods: We performed a retrospective review at a single institution of patients undergoing revision THA by a single surgeon. We identified 49 consecutive patients with large acetabular defects where the biphasic BGS was applied, with no other products added to the BGS. After placement of metallic acetabular implants, the BGS was injected into the remaining bone defects surrounding the new implants. Patients were followed and monitored for functional outcome scores, implant fixation, radiological graft site remodelling, and revision failures. Results: Mean follow-up was 39.5 months (36 to 71), with a significant improvement in post-revision function compared to preoperative function. Graft site remodelling was rated radiologically as moderate in 31 hips (63%) and strong in 12 hips (24%). There were no cases of complete graft site dissolution. No acetabular loosening was identified. None of the patients developed clinically significant heterotopic ossification. There were twelve reoperations: six patients developed post-revision infections, three experienced dislocations, two sustained periprosthetic femur fractures, and one subject had femoral component aseptic loosening. Conclusion: Our series reports bone defect restoration with the sole use of a biphasic injectable BGS in the periacetabular region. We did not observe significant graft dissolution. We emphasize that successful graft site remodelling requires meticulous recipient site preparation. Cite this article: Bone Jt Open 2022;3(12):991–997.
- 1 December 2022
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 3  (12) , 991-997
Open AccessBiphasic bone graft substitute in revision total hip arthroplasty with significant acetabular bone defects
Aims: Large acetabular bone defects encountered in revision total hip arthroplasty (THA) are challenging to restore. Metal constructs for structural support are combined with bone graft materials for restoration. Autograft is restricted due to limited volume, and allogenic grafts have downsides including cost, availability, and operative processing. Bone graft substitutes (BGS) are an attractive alternative if they can demonstrate positive remodelling. One potential product is a biphasic injectable mixture (Cerament) that combines a fast-resorbing material (calcium sulphate) with the highly osteoconductive material hydroxyapatite. This study reviews the application of this biomaterial in large acetabular defects. Methods: We performed a retrospective review at a single institution of patients undergoing revision THA by a single surgeon. We identified 49 consecutive patients with large acetabular defects where the biphasic BGS was applied, with no other products added to the BGS. After placement of metallic acetabular implants, the BGS was injected into the remaining bone defects surrounding the new implants. Patients were followed and monitored for functional outcome scores, implant fixation, radiological graft site remodelling, and revision failures. Results: Mean follow-up was 39.5 months (36 to 71), with a significant improvement in post-revision function compared to preoperative function. Graft site remodelling was rated radiologically as moderate in 31 hips (63%) and strong in 12 hips (24%). There were no cases of complete graft site dissolution. No acetabular loosening was identified. None of the patients developed clinically significant heterotopic ossification. There were twelve reoperations: six patients developed post-revision infections, three experienced dislocations, two sustained periprosthetic femur fractures, and one subject had femoral component aseptic loosening. Conclusion: Our series reports bone defect restoration with the sole use of a biphasic injectable BGS in the periacetabular region. We did not observe significant graft dissolution. We emphasize that successful graft site remodelling requires meticulous recipient site preparation. Cite this article: Bone Jt Open 2022;3(12):991–997.
- Open Access
- 11 August 2022
- Published by Wolters Kluwer Health in JAAOS: Global Research and Reviews
- Vol. 6  (8)
Outcomes of Second-stage Reimplantation After Modular Knee Arthrodesis for Periprosthetic Joint Infection
Background: Modular knee arthrodesis (MKU) is a salvage treatment for recurrent periprosthetic joint infection (PJI) or PJI associated with notable bone loss. Reimplantation endoprosthetic reconstruction (REI) is an option in patients with MKU who have PJI clearance but are not satisfied with pain or functional outcomes with MKU. The purpose of this study was to evaluate the outcomes of MKU to REI conversion. Methods: This was a single-center retrospective cohort study of 56 patients who underwent MKU to REI from 2010 to 2019. All patients were staged according to the McPherson staging system. An infecting organism was documented based on pre-MKU aspiration or intraoperative cultures at the time of MKU. Rate ratios were calculated for relevant patient factors. Rate ratios were calculated using Poisson regression with a log link. Results: The mean REI patient age was 67 years, most of the patients were McPherson B hosts (62.5%) with a type 2 (46.4%) or type 3 (51.8%) limb score, and all PJI were chronic. The most common infecting organisms at the time of MKU were Staphylococcus epidermidis (23.2%) and Staphylococcus aureus (23.2%, MSSA 14.3%, MRSA 8.9%). The mean time from MKU to REI was 220 days. An 8.9% REI index hospitalization complication rate and a 21.4% overall complication rate (excluding reinfection) were observed. Sixty-seven percent of the patients remained infection-free at an average follow-up of 37 months, among those there was 96.4% implant survivorship. No notable association was observed between index PJI organism or McPherson staging and REI failure secondary to PJI. Discussion: Approximately two thirds of patients who undergo conversion from MKU to REI have infection-free survival at the midterm follow-up. An index infecting organism and a McPherson host type do not seem to be markedly associated with reinfection risk. These findings help guide expectations of PJI MKU conversion to REI.
- 11 August 2022
- Published by Wolters Kluwer Health in JAAOS: Global Research and Reviews
- Vol. 6  (8)
Open AccessOutcomes of Second-stage Reimplantation After Modular Knee Arthrodesis for Periprosthetic Joint Infection
Background: Modular knee arthrodesis (MKU) is a salvage treatment for recurrent periprosthetic joint infection (PJI) or PJI associated with notable bone loss. Reimplantation endoprosthetic reconstruction (REI) is an option in patients with MKU who have PJI clearance but are not satisfied with pain or functional outcomes with MKU. The purpose of this study was to evaluate the outcomes of MKU to REI conversion. Methods: This was a single-center retrospective cohort study of 56 patients who underwent MKU to REI from 2010 to 2019. All patients were staged according to the McPherson staging system. An infecting organism was documented based on pre-MKU aspiration or intraoperative cultures at the time of MKU. Rate ratios were calculated for relevant patient factors. Rate ratios were calculated using Poisson regression with a log link. Results: The mean REI patient age was 67 years, most of the patients were McPherson B hosts (62.5%) with a type 2 (46.4%) or type 3 (51.8%) limb score, and all PJI were chronic. The most common infecting organisms at the time of MKU were Staphylococcus epidermidis (23.2%) and Staphylococcus aureus (23.2%, MSSA 14.3%, MRSA 8.9%). The mean time from MKU to REI was 220 days. An 8.9% REI index hospitalization complication rate and a 21.4% overall complication rate (excluding reinfection) were observed. Sixty-seven percent of the patients remained infection-free at an average follow-up of 37 months, among those there was 96.4% implant survivorship. No notable association was observed between index PJI organism or McPherson staging and REI failure secondary to PJI. Discussion: Approximately two thirds of patients who undergo conversion from MKU to REI have infection-free survival at the midterm follow-up. An index infecting organism and a McPherson host type do not seem to be markedly associated with reinfection risk. These findings help guide expectations of PJI MKU conversion to REI.
- Open Access
- 17 May 2022
- Published by Copernicus GmbH in Journal of Bone and Joint Infection
- Vol. 7  (3) , 117-125
Simulated large joint fluid model for evaluating intra-articular antibiotic delivery systems: initial evaluation using antibiotic-loaded calcium sulfate beads
Introduction: Local antimicrobial delivery via calcium sulfate (CaSO4) beads is used as an adjunctive treatment for periprosthetic joint infection. There is limited clinical information describing the performance of antimicrobial-loaded CaSO4 (ALCS) in large-scale applications. We developed a simulated large joint model to study properties of eluting ALCS. Methods: The in vitro testing platform was an adapted standardized model for tribological testing of prosthetic total hips and total knees (ASTM F732). The model was 70 mL total fluid volume, 25 % bovine serum, and 75 % phosphate-buffered saline, using ISO standard 14242-1 for human synovial fluid simulation. Four brands of CaSO4 were evaluated. Each 10 mL of CaSO4 was loaded with 1.2 grams (g) of tobramycin and 1 g of vancomycin powders. A 35 mL bead volume, equaling 175 beads, of each product was placed in incubated flasks. The test period was 6 weeks with scheduled interval fluid exchanges. Fluid samples were tested for antibiotic and calcium concentrations and pH. Results: Antibiotic elution showed an initial burst on Day 1, followed by a logarithmic reduction over 1 week. Tobramycin fully eluted within 2.5 weeks. Vancomycin showed sustained release over 6 weeks. Calcium ion concentrations were high, with gradual decrease after 3 weeks. All four CaSO4 products were inherently acidic. Fluid became more acidic with the addition of antibiotics primarily driven by vancomycin. Discussion: Clinicians should be cognizant of tobramycin elution burst with ALCS in large loads. The main driver of acidic pH levels was vancomycin. We propose that joint complications may result from lowered fluid acidity, and we suggest clinical study of synovial pH.
- 17 May 2022
- Published by Copernicus GmbH in Journal of Bone and Joint Infection
- Vol. 7  (3) , 117-125
Open AccessSimulated large joint fluid model for evaluating intra-articular antibiotic delivery systems: initial evaluation using antibiotic-loaded calcium sulfate beads
Introduction: Local antimicrobial delivery via calcium sulfate (CaSO4) beads is used as an adjunctive treatment for periprosthetic joint infection. There is limited clinical information describing the performance of antimicrobial-loaded CaSO4 (ALCS) in large-scale applications. We developed a simulated large joint model to study properties of eluting ALCS. Methods: The in vitro testing platform was an adapted standardized model for tribological testing of prosthetic total hips and total knees (ASTM F732). The model was 70 mL total fluid volume, 25 % bovine serum, and 75 % phosphate-buffered saline, using ISO standard 14242-1 for human synovial fluid simulation. Four brands of CaSO4 were evaluated. Each 10 mL of CaSO4 was loaded with 1.2 grams (g) of tobramycin and 1 g of vancomycin powders. A 35 mL bead volume, equaling 175 beads, of each product was placed in incubated flasks. The test period was 6 weeks with scheduled interval fluid exchanges. Fluid samples were tested for antibiotic and calcium concentrations and pH. Results: Antibiotic elution showed an initial burst on Day 1, followed by a logarithmic reduction over 1 week. Tobramycin fully eluted within 2.5 weeks. Vancomycin showed sustained release over 6 weeks. Calcium ion concentrations were high, with gradual decrease after 3 weeks. All four CaSO4 products were inherently acidic. Fluid became more acidic with the addition of antibiotics primarily driven by vancomycin. Discussion: Clinicians should be cognizant of tobramycin elution burst with ALCS in large loads. The main driver of acidic pH levels was vancomycin. We propose that joint complications may result from lowered fluid acidity, and we suggest clinical study of synovial pH.
- Open Access
- 9 March 2022
- Published by Elsevier in Arthroplasty Today
- Vol. 14, 116-120
Stress-Induced, Aseptic Osteolysis of the Mid-Tibia in a Revision Hinged Total Knee Arthroplasty Mimicking Infection
- 9 March 2022
- Published by Elsevier in Arthroplasty Today
- Vol. 14, 116-120
Open AccessStress-Induced, Aseptic Osteolysis of the Mid-Tibia in a Revision Hinged Total Knee Arthroplasty Mimicking Infection
- Open Access
- 10 November 2021
- Published by Copernicus GmbH in Journal of Bone and Joint Infection
- Vol. 6  (9) , 405-412
Fabrication of antibiotic-loaded dissolvable calcium sulfate beads: an in vitro mixing lab utilizing various antibiotic mixing formulas
Chronic periprosthetic joint infection (PJI) is a devastating complication that requires an aggressive eradication protocol. Local antimicrobial delivery via dissolvable calcium sulfate (CaSO4) using small-sized beads (3–8 mm) has been utilized as an adjunctive treatment combined with implant exchange, radical debridement, and antimicrobial loaded acrylic spacers. The non-exothermic setting of CaSO4 theoretically allows for any antimicrobial agent to be used, so long as mixing methods provide a consistent fabrication within a reasonable set time. This study performed the first in vitro mixing study, in which various antimicrobial agents, used singularly and in combination, were mixed with a synthetic CaSO4 product to observe and document their interactions. The study was performed in a simulated operating room environment. We report a standard mix formula with set times, testing 22 different antimicrobial agents, combinations, and doses. For some antimicrobials and combinations, set times using the standard formula were either too fast or exceedingly slow. For these 14 antimicrobial agents and combinations, we were able to arrive at individualized mixing methods. We present all mixing formulas and set times. In all, we were able to establish mixing methods that incorporate all antimicrobial agents and combinations that we have seen utilized via surgeon-directed use.
- 10 November 2021
- Published by Copernicus GmbH in Journal of Bone and Joint Infection
- Vol. 6  (9) , 405-412
Open AccessFabrication of antibiotic-loaded dissolvable calcium sulfate beads: an in vitro mixing lab utilizing various antibiotic mixing formulas
Chronic periprosthetic joint infection (PJI) is a devastating complication that requires an aggressive eradication protocol. Local antimicrobial delivery via dissolvable calcium sulfate (CaSO4) using small-sized beads (3–8 mm) has been utilized as an adjunctive treatment combined with implant exchange, radical debridement, and antimicrobial loaded acrylic spacers. The non-exothermic setting of CaSO4 theoretically allows for any antimicrobial agent to be used, so long as mixing methods provide a consistent fabrication within a reasonable set time. This study performed the first in vitro mixing study, in which various antimicrobial agents, used singularly and in combination, were mixed with a synthetic CaSO4 product to observe and document their interactions. The study was performed in a simulated operating room environment. We report a standard mix formula with set times, testing 22 different antimicrobial agents, combinations, and doses. For some antimicrobials and combinations, set times using the standard formula were either too fast or exceedingly slow. For these 14 antimicrobial agents and combinations, we were able to arrive at individualized mixing methods. We present all mixing formulas and set times. In all, we were able to establish mixing methods that incorporate all antimicrobial agents and combinations that we have seen utilized via surgeon-directed use.