Ezzat Elmoujarkach
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ezzat Elmoujarkach has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Abdulsalam Mohammed Alhawsawi
Nuclear Department, Faculty of Engineering, King Abdulaziz University, P.O. Box 80204, Jeddah 21589, Saudi Arabia
7 shared publications - Essam Banoqitah
Department of Nuclear Engineering Faculty of Engineering King Abdulaziz University P.O. Box 80204 Jeddah 21589 Saudi Arabia kau.edu.sa
6 shared publications - Fathi Djouider
Nuclear Department, Faculty of Engineering, King Abdulaziz University, P.O. Box 80204, Jeddah 21589, Saudi Arabia
4 shared publications - Eslam Taha
Nuclear Engineering Department, Faculty of Engineering, King Abdulaziz University , P.O. Box 80204 , Jeddah 21589, Saudi Arabia; , P.O. Box 80204 , Jeddah 21589, Saudi Arabia; , Queen’s Buildings, 14-17 The Parade, Cardiff CF24 3AA, UK
3 shared publications - Essam B. Moustafa
Converging Sciences and Emerging Technology (CoSET) Center, Benha National University (BNU), Al Obour 13518, Egypt
3 shared publications - Antonio Javier Gonzalez
Instituto de Instrumentación para Imagen Molecular (I3M), Centro Mixto CSIC—Universitat Politècnica de València, Camino de Vera s/n, 46022 Valencia, Spain
2 shared publications
Latest Publications
- Open Access
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (6) , 837-848
PETAL-3D: Progressive Elimination of Noise Toward Accurate Ultra Low-Count PET Images Using 3-D U-Nets
In PET, reducing the amount of radiotracer administered reduces the effective dose, at the cost of increasing image statistical noise. For low-count PET, we proposed here Progressive Elimination of Noise Towards Accurate Ultra Low-Dose PET Images Using 3D U-Nets (PETAL-3D), which operates by passing the low-count PET image (input) through multiple 3D U-Net networks. So, the image noise is gradually removed. PETAL-3D was trained on data from two PET/CT scanners; a Siemens Biograph Vision Quadra and a United Imaging uEXPLORER. Patient scans with different noise levels were used to assess PETAL-3D performance, and compare it to Gaussian filtering and conventional 3D U-Net denoising. PETAL-3D successfully restored images with a dose reduction factor (DRF) of 100 to a quality comparable to DRF20 images. After PETAL-3D denoising of DRF12 images, 91% of lesions were recovered, compared to 65% in the input. Physicians rated denoised DRF24 image quality as clinically acceptable, in contrast to the non-diagnostic quality of the DRF24 input images. A 90Y-PET scan of the AbdoMan phantom was denoised with PETAL-3D; despite the model was not trained on 90Y images, the coefficient of variation improved from 33% and 45% to 8% and 9%, in 30-min and 20-min equivalent scans, respectively.
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (6) , 837-848
Open AccessPETAL-3D: Progressive Elimination of Noise Toward Accurate Ultra Low-Count PET Images Using 3-D U-Nets
In PET, reducing the amount of radiotracer administered reduces the effective dose, at the cost of increasing image statistical noise. For low-count PET, we proposed here Progressive Elimination of Noise Towards Accurate Ultra Low-Dose PET Images Using 3D U-Nets (PETAL-3D), which operates by passing the low-count PET image (input) through multiple 3D U-Net networks. So, the image noise is gradually removed. PETAL-3D was trained on data from two PET/CT scanners; a Siemens Biograph Vision Quadra and a United Imaging uEXPLORER. Patient scans with different noise levels were used to assess PETAL-3D performance, and compare it to Gaussian filtering and conventional 3D U-Net denoising. PETAL-3D successfully restored images with a dose reduction factor (DRF) of 100 to a quality comparable to DRF20 images. After PETAL-3D denoising of DRF12 images, 91% of lesions were recovered, compared to 65% in the input. Physicians rated denoised DRF24 image quality as clinically acceptable, in contrast to the non-diagnostic quality of the DRF24 input images. A 90Y-PET scan of the AbdoMan phantom was denoised with PETAL-3D; despite the model was not trained on 90Y images, the coefficient of variation improved from 33% and 45% to 8% and 9%, in 30-min and 20-min equivalent scans, respectively.
- Open Access
- 9 February 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (3) , 039501
CORRIGENDUM: Performance evaluation of a multiplexing circuit combined with ASIC readout for cost-effective brain PET imaging (2025 Phys. Med. Biol. 70 205001)
- 9 February 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (3) , 039501
Open AccessCORRIGENDUM: Performance evaluation of a multiplexing circuit combined with ASIC readout for cost-effective brain PET imaging (2025 Phys. Med. Biol. 70 205001)
- Open Access
- 7 October 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (20) , 205001
Performance evaluation of a multiplexing circuit combined with ASIC readout for cost-effective brain PET imaging
Objective. A key challenge in PET systems is collecting large amounts of data with the most accurate information—time, energy, and position-to produce high—resolution images while limiting the number of channels to reduce costs and improve data collection efficiency. The new ultra-high-performance brain (UHB) scanner under development aims to tackle this issue, using a semi-monolithic detector that combines pixelated arrays and monolithic designs, along with signal multiplexing techniques. Approach. We assessed the time, energy, and positioning performance of the multiplexing circuit (summing signals along rows and columns) and compared it to the standard readout, both using TOFPET2 ASIC. Main Results. While time resolution worsens by about 15%, energy and positioning resolution—more crucial in small diameter scanners—are unaffected by signal summation. Overall, a pair of detector modules (2 × 2 arrays each) features an energy resolution of 16.9 ± 1.3% and 405 ± 29 ps coincidence time resolution. Positioning accuracy—estimated using multilayer perceptron neural network—is 1.9 ±0.4 mm and 3.0 ±0.7 mm along the monolithic and depth-of-interaction direction, respectively. Significance. This study demonstrates that this channel reduction readout effectively maintains high performance while allowing for reduced costs and enhanced scalability.
- 7 October 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (20) , 205001
Open AccessPerformance evaluation of a multiplexing circuit combined with ASIC readout for cost-effective brain PET imaging
Objective. A key challenge in PET systems is collecting large amounts of data with the most accurate information—time, energy, and position-to produce high—resolution images while limiting the number of channels to reduce costs and improve data collection efficiency. The new ultra-high-performance brain (UHB) scanner under development aims to tackle this issue, using a semi-monolithic detector that combines pixelated arrays and monolithic designs, along with signal multiplexing techniques. Approach. We assessed the time, energy, and positioning performance of the multiplexing circuit (summing signals along rows and columns) and compared it to the standard readout, both using TOFPET2 ASIC. Main Results. While time resolution worsens by about 15%, energy and positioning resolution—more crucial in small diameter scanners—are unaffected by signal summation. Overall, a pair of detector modules (2 × 2 arrays each) features an energy resolution of 16.9 ± 1.3% and 405 ± 29 ps coincidence time resolution. Positioning accuracy—estimated using multilayer perceptron neural network—is 1.9 ±0.4 mm and 3.0 ±0.7 mm along the monolithic and depth-of-interaction direction, respectively. Significance. This study demonstrates that this channel reduction readout effectively maintains high performance while allowing for reduced costs and enhanced scalability.
- Open Access
- 4 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 9 (3) , 362-371
Dedicated 3D-Printed Radioactive Phantoms With ¹⁸F-FDG for Ultrahigh-Resolution PET
This study explores the potential of digital light processing to 3D print radioactive phantoms for high-resolution positron emission tomography (PET). Using a slightly modified desktop 3D printer and mixtures of 18F-FDG (T1/2: 109.8 minutes) and photopolymer resin, we have printed standardized and custom radioactive objects designed for ultra-high-resolution PET, also as a first step toward complex geometries. The phantoms were: a flood source to assess uniformity, a two-point phantom for spatial resolution assessment, a multi-line phantom for validating submillimeter printing resolution, a fish-like phantom with different activity concentrations, and a 50%-downscaled micro-PET image quality phantom (NEMA NU 4-2008). Positron range effects were examined on the latter using a removable cover. The evaluation relied on planar images from a phosphor imager and tomographic images from a commercial small animal PET scanner. We were able to print radioactive uniform distributions with relative standard deviation below 4.5% and structures as small as 0.3 mm. Our two-point phantom outperformed a commercial one in terms of peak difference (6% vs. 72%) and peak-to-valley ratio (75.3 vs. 14.1). The fish-like phantom shows that printing hot regions and air cavities onto a uniform background is feasible. Future steps include using longer-lived radionuclides like 89Zr and 22Na.
- 4 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 9 (3) , 362-371
Open AccessDedicated 3D-Printed Radioactive Phantoms With ¹⁸F-FDG for Ultrahigh-Resolution PET
This study explores the potential of digital light processing to 3D print radioactive phantoms for high-resolution positron emission tomography (PET). Using a slightly modified desktop 3D printer and mixtures of 18F-FDG (T1/2: 109.8 minutes) and photopolymer resin, we have printed standardized and custom radioactive objects designed for ultra-high-resolution PET, also as a first step toward complex geometries. The phantoms were: a flood source to assess uniformity, a two-point phantom for spatial resolution assessment, a multi-line phantom for validating submillimeter printing resolution, a fish-like phantom with different activity concentrations, and a 50%-downscaled micro-PET image quality phantom (NEMA NU 4-2008). Positron range effects were examined on the latter using a removable cover. The evaluation relied on planar images from a phosphor imager and tomographic images from a commercial small animal PET scanner. We were able to print radioactive uniform distributions with relative standard deviation below 4.5% and structures as small as 0.3 mm. Our two-point phantom outperformed a commercial one in terms of peak difference (6% vs. 72%) and peak-to-valley ratio (75.3 vs. 14.1). The fish-like phantom shows that printing hot regions and air cavities onto a uniform background is feasible. Future steps include using longer-lived radionuclides like 89Zr and 22Na.
- Open Access
- 30 November 2023
- Published by MDPI AG in Lubricants
- Vol. 11 (12) , 507
A Comprehensive Investigation of BN and VC Reinforcements on the Properties of FSP AA6061 Composites
This present study investigated the impact of incorporating boron nitride (BN) and vanadium carbide (VC) reinforcements on various properties of friction stir processed (FSP) AA6061 alloy composites, focusing specifically on grain structure, thermal conductivity, electrical conductivity, and compressive strength. The findings indicate that VC more effectively refines the grain structure of the AA6061 alloy during FSP compared to BN. The inclusion of BN particles in the metal matrix composites resulted in a decrease in both thermal and electrical conductivity. In contrast, the addition of VC particles led to an increase in both thermal and electrical conductivity. The AA6061/VC composite material exhibited the highest thermal conductivity among all composites tested. The electrical conductivity of the hybrid-composite AA6061/30%BN+70%VC showed a slight reduction, measuring only 2.8% lower than the base alloy AA6061. The mono-composite AA6061/VC exhibited a marginal decrease in thermal conductivity, with a measured value only 7.5% lower than the conventional alloy AA6061. However, the mono-composite AA6061/BN displayed a more significant decline, exhibiting a loss of 14.7% and 13.9% in electrical and thermal conductivity, respectively. The composite material comprising 30% BN and 70% VC reinforcement demonstrated the highest compressive strength compared to all other tested composites. The observed percentage enhancement in the mechanical properties of mono and hybrid composites, compared to the parent AA6061 alloy, ranged from 17.1% to 31.5%.
- 30 November 2023
- Published by MDPI AG in Lubricants
- Vol. 11 (12) , 507
Open AccessA Comprehensive Investigation of BN and VC Reinforcements on the Properties of FSP AA6061 Composites
This present study investigated the impact of incorporating boron nitride (BN) and vanadium carbide (VC) reinforcements on various properties of friction stir processed (FSP) AA6061 alloy composites, focusing specifically on grain structure, thermal conductivity, electrical conductivity, and compressive strength. The findings indicate that VC more effectively refines the grain structure of the AA6061 alloy during FSP compared to BN. The inclusion of BN particles in the metal matrix composites resulted in a decrease in both thermal and electrical conductivity. In contrast, the addition of VC particles led to an increase in both thermal and electrical conductivity. The AA6061/VC composite material exhibited the highest thermal conductivity among all composites tested. The electrical conductivity of the hybrid-composite AA6061/30%BN+70%VC showed a slight reduction, measuring only 2.8% lower than the base alloy AA6061. The mono-composite AA6061/VC exhibited a marginal decrease in thermal conductivity, with a measured value only 7.5% lower than the conventional alloy AA6061. However, the mono-composite AA6061/BN displayed a more significant decline, exhibiting a loss of 14.7% and 13.9% in electrical and thermal conductivity, respectively. The composite material comprising 30% BN and 70% VC reinforcement demonstrated the highest compressive strength compared to all other tested composites. The observed percentage enhancement in the mechanical properties of mono and hybrid composites, compared to the parent AA6061 alloy, ranged from 17.1% to 31.5%.
- Open Access
The Effect of Hybrid B4C and Si3N4 Nanoparticles on the Mechanical and Physical Properties of Copper Nanocomposites
This study investigated the effects of reinforcing pure copper with hybrid B4C and Si3N4 nanoparticles on the mechanical and physical properties of the nanocomposite matrix. The composite matrix was prepared using the powder metallurgy (PM) method, allowing uniform nanoparticle dispersion within the copper matrix. The PM method was a practical approach for achieving a homogeneous and good dispersion of the reinforcing particles in the matrix while controlling the porosity and improving the microstructure of the fabricated composite matrix. The addition of B4C and Si3N4 are both very hard and dense materials. When added to a material, they can fill voids and reduce porosity. This can lead to significant improvements in the material’s mechanical properties. The study found that adding hybrid B4C and Si3N4 nanoparticles enhanced the microhardness and mechanical properties of the nanocomposites. The improvements in the mechanical and physical properties of such composites containing 5% B4C were 21.6% and 18.4% higher than the copper base alloy. The findings suggest that including ceramic particles is a viable strategy for enhancing the mechanical characteristics of copper in its pure form. For example, adding 5% B4C particles to copper resulted in a 23% increase in Young’s modulus of the material while reducing electrical conductivity by 4.6%. On the other hand, the hybrid composite Cu/5%B4C + 2.5%Si3N4 showed a 32% improvement in Young’s modulus and 71% in the microhardness value compared to the base metal. This makes it a promising option for various engineering applications, such as high-performance electrical contacts and bearings.
Open AccessThe Effect of Hybrid B4C and Si3N4 Nanoparticles on the Mechanical and Physical Properties of Copper Nanocomposites
This study investigated the effects of reinforcing pure copper with hybrid B4C and Si3N4 nanoparticles on the mechanical and physical properties of the nanocomposite matrix. The composite matrix was prepared using the powder metallurgy (PM) method, allowing uniform nanoparticle dispersion within the copper matrix. The PM method was a practical approach for achieving a homogeneous and good dispersion of the reinforcing particles in the matrix while controlling the porosity and improving the microstructure of the fabricated composite matrix. The addition of B4C and Si3N4 are both very hard and dense materials. When added to a material, they can fill voids and reduce porosity. This can lead to significant improvements in the material’s mechanical properties. The study found that adding hybrid B4C and Si3N4 nanoparticles enhanced the microhardness and mechanical properties of the nanocomposites. The improvements in the mechanical and physical properties of such composites containing 5% B4C were 21.6% and 18.4% higher than the copper base alloy. The findings suggest that including ceramic particles is a viable strategy for enhancing the mechanical characteristics of copper in its pure form. For example, adding 5% B4C particles to copper resulted in a 23% increase in Young’s modulus of the material while reducing electrical conductivity by 4.6%. On the other hand, the hybrid composite Cu/5%B4C + 2.5%Si3N4 showed a 32% improvement in Young’s modulus and 71% in the microhardness value compared to the base metal. This makes it a promising option for various engineering applications, such as high-performance electrical contacts and bearings.
- Open Access
The Role of Friction Stir Processing Parameters and Hybrid ZrC/WC Reinforcement Particles in Improving the Surface Composite Dissimilar Matrix’s Dynamic Behavior and Microstructure Refinement
This study examined the impact of hybrid reinforcement particles, specifically zirconium carbide (ZrC) and tungsten carbide (WC), as well as the parameters of friction stir processing (FSP), on the microstructure, mechanical properties, and dynamic behavior of aluminum alloys. The hybrid particles were integrated into the aluminum alloy using friction stir processing (FSP). The fabricated metal matrix composites (MMCs) were characterized using optical microscopy, scanning electron microscopy (SEM), and dynamic mechanical analysis (DMA). The results showed that the FSP parameters and reinforcement particles played an important role in improving the grain refinement of the MMCs. This study’s results suggest that the FSP samples’ UTS can be maximized using a tool rotation speed of 600 rpm and a traverse speed of 30 mm/min. The grain refinement in the composite surface was attributed to the dynamic recrystallization during the friction stir processing (FSP) process. The reinforcement particles also acted as grain growth restrictors, further refining the grain size. This resulted in a 34% increase in ultimate tensile strength compared to AA2024 alloys and a 12% increase compared to AA7075 alloys. The composite surface also exhibited enhanced dynamic properties, with an increase in impact energy of 26%. The free vibration test showed that the hybrid reinforcement particles significantly improved the strength and damping capacity of the aluminum alloys, resulting in a high resonant frequency. This is important for applications such as vibration damping and noise reduction.
Open AccessThe Role of Friction Stir Processing Parameters and Hybrid ZrC/WC Reinforcement Particles in Improving the Surface Composite Dissimilar Matrix’s Dynamic Behavior and Microstructure Refinement
This study examined the impact of hybrid reinforcement particles, specifically zirconium carbide (ZrC) and tungsten carbide (WC), as well as the parameters of friction stir processing (FSP), on the microstructure, mechanical properties, and dynamic behavior of aluminum alloys. The hybrid particles were integrated into the aluminum alloy using friction stir processing (FSP). The fabricated metal matrix composites (MMCs) were characterized using optical microscopy, scanning electron microscopy (SEM), and dynamic mechanical analysis (DMA). The results showed that the FSP parameters and reinforcement particles played an important role in improving the grain refinement of the MMCs. This study’s results suggest that the FSP samples’ UTS can be maximized using a tool rotation speed of 600 rpm and a traverse speed of 30 mm/min. The grain refinement in the composite surface was attributed to the dynamic recrystallization during the friction stir processing (FSP) process. The reinforcement particles also acted as grain growth restrictors, further refining the grain size. This resulted in a 34% increase in ultimate tensile strength compared to AA2024 alloys and a 12% increase compared to AA7075 alloys. The composite surface also exhibited enhanced dynamic properties, with an increase in impact energy of 26%. The free vibration test showed that the hybrid reinforcement particles significantly improved the strength and damping capacity of the aluminum alloys, resulting in a high resonant frequency. This is important for applications such as vibration damping and noise reduction.
- Open Access
- 1 June 2022
- Published by Walter de Gruyter GmbH in Nukleonika
- Vol. 67 (2) , 35-40
Utilization of an energy-resolving detection system for mammography applications: A preliminary study
Breast cancer remains one of the major causes of mortality among female cancer patients. This fact caused a spark in the medical field, which in turn helped to improve the diagnostic and treatment of breast cancer patients over the years making this field always active with new ideas and innovative methods. In our study, a new method was explored using an energy-resolving detection system made from a NaI (Tl) scintillation detector to detect the gamma photons from an Am-241 radiation source to try and construct an image by scanning the American College of Radiology (ACR) mammography phantom. In addition to the experimental work, a Geant4 Application for Tomographic Emission (GATE) toolkit was used to investigate more complex options to improve the image quality of mammographic systems, which is limited by the experimental setup. From the experimental setup, the researchers were able to construct an image using the 26.3 keV and the 59.5 keV energy photons, to show the largest size tumour (12 mm) in the ACR phantom. With an improved setup in the simulation environment, the majority of the ACR phantom tumours was visible using both energy windows from the 26.3 keV and the 59.5 keV, where the 26.3 keV yielded better quality images showing four tumours compared to three when using 59.5 keV. The simulation results were promising; however, several improvements need to be incorporated into the experimental work so that the system can generate high-resolution mammographic images similar to the ones obtained by the GATE simulation setup.
- 1 June 2022
- Published by Walter de Gruyter GmbH in Nukleonika
- Vol. 67 (2) , 35-40
Open AccessUtilization of an energy-resolving detection system for mammography applications: A preliminary study
Breast cancer remains one of the major causes of mortality among female cancer patients. This fact caused a spark in the medical field, which in turn helped to improve the diagnostic and treatment of breast cancer patients over the years making this field always active with new ideas and innovative methods. In our study, a new method was explored using an energy-resolving detection system made from a NaI (Tl) scintillation detector to detect the gamma photons from an Am-241 radiation source to try and construct an image by scanning the American College of Radiology (ACR) mammography phantom. In addition to the experimental work, a Geant4 Application for Tomographic Emission (GATE) toolkit was used to investigate more complex options to improve the image quality of mammographic systems, which is limited by the experimental setup. From the experimental setup, the researchers were able to construct an image using the 26.3 keV and the 59.5 keV energy photons, to show the largest size tumour (12 mm) in the ACR phantom. With an improved setup in the simulation environment, the majority of the ACR phantom tumours was visible using both energy windows from the 26.3 keV and the 59.5 keV, where the 26.3 keV yielded better quality images showing four tumours compared to three when using 59.5 keV. The simulation results were promising; however, several improvements need to be incorporated into the experimental work so that the system can generate high-resolution mammographic images similar to the ones obtained by the GATE simulation setup.
- Open Access
- 17 February 2022
- Published by Walter de Gruyter GmbH in Nukleonika
- Vol. 67 (1) , 11-18
Prompt gamma-ray methods for industrial process evaluation: A simulation study
Radioisotope applications in industrial process inspection and evaluation using gamma-ray emitters provide otherwise unavailable information. Offering alternative gamma-ray sources can support the technology by complementing sources’ availability and radiation safety. This work proposes to replace gamma-ray from radioisotopes with prompt gamma-ray from the interaction of neutrons with stable isotopes injected into the industrial process or with the structural material of the industrial process equipment. Monte Carlo N-Particle Transport Code (MCNP5) was used to simulate the irradiation of two-phase flow pipes by 252Cf neutron source. Two simulations were run for each pipe, with and without mixing the liquid phase with the stable isotope 157Gd. The detected gamma-ray spectra were analysed, and images of the two phases inside the pipes were produced. The images were compared to images obtained from simulations of gamma transmission measurement using 60Co. Furthermore, results for prompt gamma computed tomography (CT) were presented and discussed. The studies’ outcomes indicate the potential of prompt gamma-ray to carry out the sealed sources applications of gamma transmission measurements and imaging.
- 17 February 2022
- Published by Walter de Gruyter GmbH in Nukleonika
- Vol. 67 (1) , 11-18
Open AccessPrompt gamma-ray methods for industrial process evaluation: A simulation study
Radioisotope applications in industrial process inspection and evaluation using gamma-ray emitters provide otherwise unavailable information. Offering alternative gamma-ray sources can support the technology by complementing sources’ availability and radiation safety. This work proposes to replace gamma-ray from radioisotopes with prompt gamma-ray from the interaction of neutrons with stable isotopes injected into the industrial process or with the structural material of the industrial process equipment. Monte Carlo N-Particle Transport Code (MCNP5) was used to simulate the irradiation of two-phase flow pipes by 252Cf neutron source. Two simulations were run for each pipe, with and without mixing the liquid phase with the stable isotope 157Gd. The detected gamma-ray spectra were analysed, and images of the two phases inside the pipes were produced. The images were compared to images obtained from simulations of gamma transmission measurement using 60Co. Furthermore, results for prompt gamma computed tomography (CT) were presented and discussed. The studies’ outcomes indicate the potential of prompt gamma-ray to carry out the sealed sources applications of gamma transmission measurements and imaging.
- 8 March 2021
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 47 (1) , 795-799
A Simulation Analysis for Thermal Neutron Applications of ABS 3D Printing Filament Doped with Nanoparticles
- 8 March 2021
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 47 (1) , 795-799
A Simulation Analysis for Thermal Neutron Applications of ABS 3D Printing Filament Doped with Nanoparticles