Xinming Ye
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xinming Ye has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Chenyun Dai
School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200240, P. R. China
7 shared publications - Wei Chen
The University of Sydney
7 shared publications - Xinyu Jiang
School of Informatics, The University of Edinburgh, Edinburgh, U.K.
6 shared publications - Jiahao Fan
Department of Mechanical Engineering, Pennsylvania State University, USA
5 shared publications - Edward A. Clancy
Worcester Polytechnic Institute, Worcester, MA, USA
4 shared publications Xiangyu Liu
College of Communication and Art Design, University of Shanghai for Science and Technology, Shanghai, China
4 shared publications
Latest Publications
- Open Access
- 1 January 2026
- Published by Wiley in International Journal Of Clinical Practice
- Vol. 2026 (1) , 1624893
The 20‐Meter Shuttle Run Test as a Feasible Tool for Physical Fitness Surveillance in Chinese Children and Adolescents: A Nationwide Cross‐Sectional Study
Objective: We examine the association between the 20‐m shuttle run test and physical fitness in a large nationwide sample of Chinese children and adolescents aged 7–18 years. Methods: A total of 85,535 children and adolescents (43,902 boys and 41,633 girls) were enrolled in this study. We measured height, weight, waist circumference (WC), grip strength, standing long jump, 30‐s sit‐ups, sit and reach, 50‐m dash, 20‐s repeated straddling, and 20‐m shuttle run test. Body mass index (BMI) was calculated as weight/height 2 . VO 2 max/kg and VO 2max were calculated from the 20‐m shuttle run test using the model developed by Léger et al. Pearson correlation and multiple regression analyses were conducted for the analysis. Results: Correlations between parameters (age, height, weight, BMI, WC, grip strength, standing long jump, 30‐s sit‐ups, sit and reach, 50‐m dash, 20‐s repeated straddling) were significant ( p < 0.05). The results of multiple regression analysis showed that 20‐m shuttle run test, VO 2max/kg , and VO 2max were significantly correlated with age, height, weight, BMI, WC, grip strength, standing long jump, 30‐s sit‐ups, sit and reach, 50‐m dash, and 20‐s repeated straddling in Chinese children and adolescents. Conclusions: The present study shows associations between 20‐m shuttle run test and physical fitness of Chinese children and adolescents. Hence, the 20‐m shuttle run test can be a feasible tool for population physical fitness surveillance and inform policy‐making and public health planning. Further studies are needed to further elucidate the relationships between 20‐m shuttle run test and physical fitness, providing references for physical fitness screening.
- 1 January 2026
- Published by Wiley in International Journal Of Clinical Practice
- Vol. 2026 (1) , 1624893
Open AccessThe 20‐Meter Shuttle Run Test as a Feasible Tool for Physical Fitness Surveillance in Chinese Children and Adolescents: A Nationwide Cross‐Sectional Study
Objective: We examine the association between the 20‐m shuttle run test and physical fitness in a large nationwide sample of Chinese children and adolescents aged 7–18 years. Methods: A total of 85,535 children and adolescents (43,902 boys and 41,633 girls) were enrolled in this study. We measured height, weight, waist circumference (WC), grip strength, standing long jump, 30‐s sit‐ups, sit and reach, 50‐m dash, 20‐s repeated straddling, and 20‐m shuttle run test. Body mass index (BMI) was calculated as weight/height 2 . VO 2 max/kg and VO 2max were calculated from the 20‐m shuttle run test using the model developed by Léger et al. Pearson correlation and multiple regression analyses were conducted for the analysis. Results: Correlations between parameters (age, height, weight, BMI, WC, grip strength, standing long jump, 30‐s sit‐ups, sit and reach, 50‐m dash, 20‐s repeated straddling) were significant ( p < 0.05). The results of multiple regression analysis showed that 20‐m shuttle run test, VO 2max/kg , and VO 2max were significantly correlated with age, height, weight, BMI, WC, grip strength, standing long jump, 30‐s sit‐ups, sit and reach, 50‐m dash, and 20‐s repeated straddling in Chinese children and adolescents. Conclusions: The present study shows associations between 20‐m shuttle run test and physical fitness of Chinese children and adolescents. Hence, the 20‐m shuttle run test can be a feasible tool for population physical fitness surveillance and inform policy‐making and public health planning. Further studies are needed to further elucidate the relationships between 20‐m shuttle run test and physical fitness, providing references for physical fitness screening.
- 1 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 10 (5) , 4388-4402
Optimizing the Cross-Day Performance of Electromyogram Biometric Decoder
With massive data collected in Internet of Things (IoT)-based smart environment, improving privacy preservation via client verification and identification is crucial. Surface electromyogram (sEMG) has emerged as a cancelable neuromuscular biometric trait, which makes up the noncancelability flaw of the traditional face and fingerprint biometrics. Current studies are in the proof-of-concept stage. In-depth studies to find the optimal solution to decode sEMG biometrics with excellent cross-day performance are very scarce. For neurophysiological biometrics, the permanence across time is a crucial factor. Our work aims to optimize the cross-day performance of the sEMG biometric decoder. We systematically evaluated the performance of 28 hand gestures to generate sEMG, 55 temporal–spectral–spatial features to represent sEMG, 9 distance measures and 9 classifiers to make decisions. Both biometric verification and identification were investigated in rigorous cross-day validations. Results show that the optimal combination of ≥ 10 temporal–spectral–spatial features achieved the best cross-day performance with city-block distance and support vector machine (SVM) applied. EMG generated by middle finger extension and hand close is preferred as biometric tokens. Using the optimized decoder, a cross-day identification accuracy of 88.75% and verification error rate of 9.85% were achieved. The verification error rate could be further reduced to 2.45% if impostors input sEMG under random gestures. Moreover, our work proved the reliability of sEMG biometrics even under muscle fatigue for the first time. This is also the first study to systematically evaluate the cross-day performance of different components in sEMG biometric decoding systems, serving as a technique-screening tool for future studies.
- 1 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 10 (5) , 4388-4402
Optimizing the Cross-Day Performance of Electromyogram Biometric Decoder
With massive data collected in Internet of Things (IoT)-based smart environment, improving privacy preservation via client verification and identification is crucial. Surface electromyogram (sEMG) has emerged as a cancelable neuromuscular biometric trait, which makes up the noncancelability flaw of the traditional face and fingerprint biometrics. Current studies are in the proof-of-concept stage. In-depth studies to find the optimal solution to decode sEMG biometrics with excellent cross-day performance are very scarce. For neurophysiological biometrics, the permanence across time is a crucial factor. Our work aims to optimize the cross-day performance of the sEMG biometric decoder. We systematically evaluated the performance of 28 hand gestures to generate sEMG, 55 temporal–spectral–spatial features to represent sEMG, 9 distance measures and 9 classifiers to make decisions. Both biometric verification and identification were investigated in rigorous cross-day validations. Results show that the optimal combination of ≥ 10 temporal–spectral–spatial features achieved the best cross-day performance with city-block distance and support vector machine (SVM) applied. EMG generated by middle finger extension and hand close is preferred as biometric tokens. Using the optimized decoder, a cross-day identification accuracy of 88.75% and verification error rate of 9.85% were achieved. The verification error rate could be further reduced to 2.45% if impostors input sEMG under random gestures. Moreover, our work proved the reliability of sEMG biometrics even under muscle fatigue for the first time. This is also the first study to systematically evaluate the cross-day performance of different components in sEMG biometric decoding systems, serving as a technique-screening tool for future studies.
- 6 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-15
Measuring Neuromuscular Electrophysiological Activities to Decode HD-sEMG Biometrics for Cross-Application Discrepant Personal Identification With Unknown Identities
Measuring the physical, physiological, behavioural or chemical characteristics of an individual as biometrics for personal identification has attracted increasing attentions in smart environment applications. Noncancelability and cross-application invariance are two flaws of traditional DNA, face and fingerprint-based biometrics, because users cannot volitionally change the biometric template. In this work, we acquired high-density surface electromyogram (HD-sEMG) signals encoded by gesture passwords as biometrics. The different sEMG patterns under different motor tasks allow users to enroll multiple accounts using sEMG under different hand gestures as biometrics. By simply changing to a new gesture password, users can cancel the original template once it is compromised. Even if impostors enter the correct gesture password, the individual differences of HD-sEMG as the second defense, can still achieve excellent performance. To improve the current state-of-the-art identification accuracy, we acquired 256-channel forearm HD-sEMG and decoded high-resolution neuromuscular information in temporal-spectral-spatial domain. We achieved a high identification accuracy of 99.85% on a 200-account (20 subjects × 10 accounts per subject) recognition task, with training and testing data acquired 3–25 days apart. Moreover, to address the concern of “unknown identities,” we applied an “authentication + identification” validation, achieving a high accuracy of 93.81% on a 200-account ((16 enrolled subjects + 4 unknown subjects) × 10 accounts per subject) task. Our work substantially improves the current state-of-the-art accuracy for cross-day sEMG biometric identification (improved from ~ 88% to > 99%, with a similar number of identified classes).
- 6 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-15
Measuring Neuromuscular Electrophysiological Activities to Decode HD-sEMG Biometrics for Cross-Application Discrepant Personal Identification With Unknown Identities
Measuring the physical, physiological, behavioural or chemical characteristics of an individual as biometrics for personal identification has attracted increasing attentions in smart environment applications. Noncancelability and cross-application invariance are two flaws of traditional DNA, face and fingerprint-based biometrics, because users cannot volitionally change the biometric template. In this work, we acquired high-density surface electromyogram (HD-sEMG) signals encoded by gesture passwords as biometrics. The different sEMG patterns under different motor tasks allow users to enroll multiple accounts using sEMG under different hand gestures as biometrics. By simply changing to a new gesture password, users can cancel the original template once it is compromised. Even if impostors enter the correct gesture password, the individual differences of HD-sEMG as the second defense, can still achieve excellent performance. To improve the current state-of-the-art identification accuracy, we acquired 256-channel forearm HD-sEMG and decoded high-resolution neuromuscular information in temporal-spectral-spatial domain. We achieved a high identification accuracy of 99.85% on a 200-account (20 subjects × 10 accounts per subject) recognition task, with training and testing data acquired 3–25 days apart. Moreover, to address the concern of “unknown identities,” we applied an “authentication + identification” validation, achieving a high accuracy of 93.81% on a 200-account ((16 enrolled subjects + 4 unknown subjects) × 10 accounts per subject) task. Our work substantially improves the current state-of-the-art accuracy for cross-day sEMG biometric identification (improved from ~ 88% to > 99%, with a similar number of identified classes).
- 26 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Human-Machine Systems
- Vol. 52 (6) , 1281-1291
Optimization of HD-sEMG-Based Cross-Day Hand Gesture Classification by Optimal Feature Extraction and Data Augmentation
Human–machine interaction requires accurate recognition of human intentions (e.g., via hand gestures). Here, we assessed the cross-day robustness of widely used hand gesture classification techniques applied to high-density surface electromyogram (HD-sEMG) signals (256 channels). Our evaluation covered techniques in each stage of the classification framework: first, 50 temporal-spectral-spatial domain features, second, 15 feature optimization techniques, and third, seven classifiers. Moreover, although HD-sEMG provides sufficient neuromuscular information, some of the channels may present low signal-to-noise ratio and should therefore be treated as outliers. Accordingly, we performed our evaluation with, first, all outlier channels retained, and second, removal of the features corresponding to poor-quality channels and substitution with interpolated values from neighbor channels. The impact of sliding window and data augmentation was also investigated. We examined the results on a 35-gesture classification task using HD-sEMG acquired from 20 subjects on two sessions in separate days. The results showed that interpolation of features from outlier channels significantly improved the performance in most cases. Use of a sliding window and of data augmentation contributed to a higher classification accuracy. For the classification of 11 selected gestures of common daily use, the support vector machine classifier achieved the highest classification accuracy of 91.9% in a cross-day validation protocol using an optimal combination of 13 features (each extracted from sliding windows), feature optimization by linear discriminant analysis, and data augmentation. Our work can serve as a technique-screening tool on cross-day applications of human–machine interactions.
- 26 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Human-Machine Systems
- Vol. 52 (6) , 1281-1291
Optimization of HD-sEMG-Based Cross-Day Hand Gesture Classification by Optimal Feature Extraction and Data Augmentation
Human–machine interaction requires accurate recognition of human intentions (e.g., via hand gestures). Here, we assessed the cross-day robustness of widely used hand gesture classification techniques applied to high-density surface electromyogram (HD-sEMG) signals (256 channels). Our evaluation covered techniques in each stage of the classification framework: first, 50 temporal-spectral-spatial domain features, second, 15 feature optimization techniques, and third, seven classifiers. Moreover, although HD-sEMG provides sufficient neuromuscular information, some of the channels may present low signal-to-noise ratio and should therefore be treated as outliers. Accordingly, we performed our evaluation with, first, all outlier channels retained, and second, removal of the features corresponding to poor-quality channels and substitution with interpolated values from neighbor channels. The impact of sliding window and data augmentation was also investigated. We examined the results on a 35-gesture classification task using HD-sEMG acquired from 20 subjects on two sessions in separate days. The results showed that interpolation of features from outlier channels significantly improved the performance in most cases. Use of a sliding window and of data augmentation contributed to a higher classification accuracy. For the classification of 11 selected gestures of common daily use, the support vector machine classifier achieved the highest classification accuracy of 91.9% in a cross-day validation protocol using an optimal combination of 13 features (each extracted from sliding windows), feature optimization by linear discriminant analysis, and data augmentation. Our work can serve as a technique-screening tool on cross-day applications of human–machine interactions.
- 28 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 26 (4) , 1782-1793
Cancelable HD-SEMG Biometric Identification via Deep Feature Learning
Conventional biometric modalities, such as the face, fingerprint, and iris, are vulnerable against imitation and circumvention. Accordingly, secure biometric modalities with cancelable properties are needed for personal identification, especially in smart healthcare applications. Here we developed a person identification model using high-density surface electromyography (HD-sEMG) as biometric traits. In this model, the HD-sEMG biometric templates are cancelable and could be customized by the users through finger isometric contractions. A deep feature learning approach, implemented by convolutional neural networks (CNNs) is used to capture user-specific patterns from HD-sEMG signals and make identification decisions. This model has been validated on twenty-two subjects, with training and testing data acquired from two different days. The rank-1 identification accuracy and equal error rate for 44 identities (22 subjects × 2 accounts) can reach 87.23% and 4.66%, respectively. The cross-day identification accuracy of the proposed model is higher than the results of previous methods reported in the literature. The usability and efficiency of the proposed model are also investigated, indicating its potentials for practical applications.
- 28 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 26 (4) , 1782-1793
Cancelable HD-SEMG Biometric Identification via Deep Feature Learning
Conventional biometric modalities, such as the face, fingerprint, and iris, are vulnerable against imitation and circumvention. Accordingly, secure biometric modalities with cancelable properties are needed for personal identification, especially in smart healthcare applications. Here we developed a person identification model using high-density surface electromyography (HD-sEMG) as biometric traits. In this model, the HD-sEMG biometric templates are cancelable and could be customized by the users through finger isometric contractions. A deep feature learning approach, implemented by convolutional neural networks (CNNs) is used to capture user-specific patterns from HD-sEMG signals and make identification decisions. This model has been validated on twenty-two subjects, with training and testing data acquired from two different days. The rank-1 identification accuracy and equal error rate for 44 identities (22 subjects × 2 accounts) can reach 87.23% and 4.66%, respectively. The cross-day identification accuracy of the proposed model is higher than the results of previous methods reported in the literature. The usability and efficiency of the proposed model are also investigated, indicating its potentials for practical applications.
- 1 September 2021
- Published by Elsevier in Neuroscience Letters
- Vol. 761, 136101
Changes in synchronization of the motor unit in muscle fatigue condition during the dynamic and isometric contraction in the Biceps Brachii muscle
- 1 September 2021
- Published by Elsevier in Neuroscience Letters
- Vol. 761, 136101
Changes in synchronization of the motor unit in muscle fatigue condition during the dynamic and isometric contraction in the Biceps Brachii muscle
- 22 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 8 (22) , 16535-16547
Enhancing IoT Security via Cancelable HD-sEMG-Based Biometric Authentication Password, Encoded by Gesture
Enhancing information security via reliable user authentication in wireless body area network (WBAN)-based Internet-of-Things (IoT) applications has attracted increasing attention. The noncancelability of traditional biometrics (e.g., fingerprint) for user authentication increases the privacy disclosure risks once the biometric template is exposed, because users cannot volitionally create a new template. In this work, we propose a cancelable biometric modality based on high-density surface electromyogram (HD-sEMG) encoded by hand gesture password, for user authentication. HD-sEMG signals (256 channels) were acquired from the forearm muscles when users performed a prescribed gesture password, forming their biometric token. Thirty four alternative hand gestures in common daily use were studied. Moreover, to reduce the data acquisition and transmission burden in IoT devices, an automatically generated password-specific channel mask was employed to reduce the number of active channels. HD-sEMG biometrics were also robust with reduced sampling rate, further reducing power consumption. HD-sEMG biometrics achieved a low equal error rate (EER) of 0.0013 when impostors entered a wrong gesture password, as validated on 20 subjects. Even if impostors entered the correct gesture password, the HD-sEMG biometrics still achieved an EER of 0.0273. If the HD-sEMG biometric template was exposed, users could cancel it by simply changing it to a new gesture password, with an EER of 0.0013. To the best of our knowledge, this is the first study to employ HD-sEMG signals under common daily hand gestures as biometric tokens, with training and testing data acquired on different days.
- 22 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 8 (22) , 16535-16547
Enhancing IoT Security via Cancelable HD-sEMG-Based Biometric Authentication Password, Encoded by Gesture
Enhancing information security via reliable user authentication in wireless body area network (WBAN)-based Internet-of-Things (IoT) applications has attracted increasing attention. The noncancelability of traditional biometrics (e.g., fingerprint) for user authentication increases the privacy disclosure risks once the biometric template is exposed, because users cannot volitionally create a new template. In this work, we propose a cancelable biometric modality based on high-density surface electromyogram (HD-sEMG) encoded by hand gesture password, for user authentication. HD-sEMG signals (256 channels) were acquired from the forearm muscles when users performed a prescribed gesture password, forming their biometric token. Thirty four alternative hand gestures in common daily use were studied. Moreover, to reduce the data acquisition and transmission burden in IoT devices, an automatically generated password-specific channel mask was employed to reduce the number of active channels. HD-sEMG biometrics were also robust with reduced sampling rate, further reducing power consumption. HD-sEMG biometrics achieved a low equal error rate (EER) of 0.0013 when impostors entered a wrong gesture password, as validated on 20 subjects. Even if impostors entered the correct gesture password, the HD-sEMG biometrics still achieved an EER of 0.0273. If the HD-sEMG biometric template was exposed, users could cancel it by simply changing it to a new gesture password, with an EER of 0.0013. To the best of our knowledge, this is the first study to employ HD-sEMG signals under common daily hand gestures as biometric tokens, with training and testing data acquired on different days.
- 1 January 2021
- Published by Human Kinetics in Motor Control
- Vol. 25 (1) , 100-116
Generalized Finger Motion Classification Model Based on Motor Unit Voting
Surface electromyogram-based finger motion classification has shown its potential for prosthetic control. However, most current finger motion classification models are subject-specific, requiring calibration when applied to new subjects. Generalized subject-nonspecific models are essential for real-world applications. In this study, the authors developed a subject-nonspecific model based on motor unit (MU) voting. A high-density surface electromyogram was first decomposed into individual MUs. The features extracted from each MU were then fed into a random forest classifier to obtain the finger label (primary prediction). The final prediction was selected by voting for all primary predictions provided by the decomposed MUs. Experiments conducted on 14 subjects demonstrated that our method significantly outperformed traditional methods in the context of subject-nonspecific finger motion classification models.
- 1 January 2021
- Published by Human Kinetics in Motor Control
- Vol. 25 (1) , 100-116
Generalized Finger Motion Classification Model Based on Motor Unit Voting
Surface electromyogram-based finger motion classification has shown its potential for prosthetic control. However, most current finger motion classification models are subject-specific, requiring calibration when applied to new subjects. Generalized subject-nonspecific models are essential for real-world applications. In this study, the authors developed a subject-nonspecific model based on motor unit (MU) voting. A high-density surface electromyogram was first decomposed into individual MUs. The features extracted from each MU were then fed into a random forest classifier to obtain the finger label (primary prediction). The final prediction was selected by voting for all primary predictions provided by the decomposed MUs. Experiments conducted on 14 subjects demonstrated that our method significantly outperformed traditional methods in the context of subject-nonspecific finger motion classification models.
- 15 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 25 (3) , 647-655
Quantifying Spatial Activation Patterns of Motor Units in Finger Extensor Muscles
The ability to expertly control different fingers contributes to hand dexterity during object manipulation in daily life activities. The macroscopic spatial patterns of muscle activations during finger movements using global surface electromyography (sEMG) have been widely researched. However, the spatial activation patterns of microscopic motor units (MUs) under different finger movements have not been well investigated. The present work aims to quantify MU spatial activation patterns during movement of distinct fingers (index, middle, ring and little finger). Specifically, we focused on extensor muscles during extension contractions. Motor unit action potentials (MUAPs) during movement of each finger were obtained through decomposition of high-density sEMG (HD-sEMG). First, we quantified the spatial activation patterns of MUs for each finger based on 2-dimension (2-D) root-mean-square (RMS) maps of MUAP grids after spike-triggered averaging. We found that these activation patterns under different finger movements are distinct along the distal-proximal direction, but with partial overlap. Second, to further evaluate MU separability, we classified the spatial activation pattern of each individual MU under distinct finger movement and associated each MU with its corresponding finger with Regularized Uncorrelated Multilinear Discriminant Analysis (RUMLDA). A high accuracy of MU-finger classification tested on 12 subjects with a mean of 88.98% was achieved. The quantification of MU spatial activation patterns could be beneficial to studies of neural mechanisms of the hand. To the best of our knowledge, this is the first work which manages to quantify MU behaviors under different finger movements.
- 15 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 25 (3) , 647-655
Quantifying Spatial Activation Patterns of Motor Units in Finger Extensor Muscles
The ability to expertly control different fingers contributes to hand dexterity during object manipulation in daily life activities. The macroscopic spatial patterns of muscle activations during finger movements using global surface electromyography (sEMG) have been widely researched. However, the spatial activation patterns of microscopic motor units (MUs) under different finger movements have not been well investigated. The present work aims to quantify MU spatial activation patterns during movement of distinct fingers (index, middle, ring and little finger). Specifically, we focused on extensor muscles during extension contractions. Motor unit action potentials (MUAPs) during movement of each finger were obtained through decomposition of high-density sEMG (HD-sEMG). First, we quantified the spatial activation patterns of MUs for each finger based on 2-dimension (2-D) root-mean-square (RMS) maps of MUAP grids after spike-triggered averaging. We found that these activation patterns under different finger movements are distinct along the distal-proximal direction, but with partial overlap. Second, to further evaluate MU separability, we classified the spatial activation pattern of each individual MU under distinct finger movement and associated each MU with its corresponding finger with Regularized Uncorrelated Multilinear Discriminant Analysis (RUMLDA). A high accuracy of MU-finger classification tested on 12 subjects with a mean of 88.98% was achieved. The quantification of MU spatial activation patterns could be beneficial to studies of neural mechanisms of the hand. To the best of our knowledge, this is the first work which manages to quantify MU behaviors under different finger movements.