Songtao Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Songtao Huang has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Jie Ye
National Key Laboratory of Science and Technology on Multispectral Information Processing and Key Laboratory of Image Processing and Intelligent Control, School of Artificial Intelligence and Automation, Huazhong University of Science and Technology, Wuhan, China
9 shared publications - Anwen Shen
National Key Laboratory of Science and Technology on Multispectral Information Processing and Key Laboratory of Image Processing and Intelligent Control, School of Artificial Intelligence and Automation, Huazhong University of Science and Technology, Wuhan, China
8 shared publications - Jinbang Xu
National Key Laboratory of Science and Technology on Multispectral Information Processing and Key Laboratory of Image Processing and Intelligent Control, School of Artificial Intelligence and Automation, Huazhong University of Science and Technology, Wuhan, China
8 shared publications - Haozhe Wang
National Key Laboratory of Science and Technology on Multispectral Information Processing and Key Laboratory of Image Processing and Intelligent Control, School of Artificial Intelligence and Automation, Huazhong University of Science and Technology, Wuhan, China
4 shared publications - Yihua Hu
King’s College London
4 shared publications - Yukai Huang
National Key Laboratory of Science and Technology on Multispectral Information Processing and Key Laboratory of Image Processing and Intelligent Control, School of Artificial Intelligence and Automation, Huazhong University of Science and Technology, Wuhan, China
4 shared publications
Latest Publications
- 11 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. PP (21686777) , 1
Passivity-Oriented Analysis of Control Delay on Output Admittance Beyond the Nyquist Frequency of Grid-Following Inverters
The interconnection stability of grid-connected inverters can be evaluated through the dissipative characteristics of the output admittance. While the influence of admittance components beyond the Nyquist frequency on stability has been recognized, the effects of control delays on high-frequency admittance behavior still merit further investigation. A detailed analysis of output admittance is presented considering two primary delay sources the system sampling period and the sampling instant. The absolute delay defined by the sampling frequency is quantitatively assessed and the relative delay caused by the sampling instant affects both the depth and the span of the negative damping region. The results indicate that although increasing the sampling frequency mitigates non-passive admittance effects above the Nyquist frequency, non-passivity remains a key contributor to high-frequency instability. To address this issue, an admittance-based passive damping method is developed based on an admittance model that includes frequency aliasing effects to improve high-frequency stability. Experimental results validate the theoretical analysis and demonstrate the effectiveness of the proposed method.
- 11 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. PP (21686777) , 1
Passivity-Oriented Analysis of Control Delay on Output Admittance Beyond the Nyquist Frequency of Grid-Following Inverters
The interconnection stability of grid-connected inverters can be evaluated through the dissipative characteristics of the output admittance. While the influence of admittance components beyond the Nyquist frequency on stability has been recognized, the effects of control delays on high-frequency admittance behavior still merit further investigation. A detailed analysis of output admittance is presented considering two primary delay sources the system sampling period and the sampling instant. The absolute delay defined by the sampling frequency is quantitatively assessed and the relative delay caused by the sampling instant affects both the depth and the span of the negative damping region. The results indicate that although increasing the sampling frequency mitigates non-passive admittance effects above the Nyquist frequency, non-passivity remains a key contributor to high-frequency instability. To address this issue, an admittance-based passive damping method is developed based on an admittance model that includes frequency aliasing effects to improve high-frequency stability. Experimental results validate the theoretical analysis and demonstrate the effectiveness of the proposed method.
- Open Access
- 5 February 2026
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 175
Stability enhancement of multi-parallel inverter systems in distributed power grids with unconventional control delay
- 5 February 2026
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 175
Open AccessStability enhancement of multi-parallel inverter systems in distributed power grids with unconventional control delay
- Open Access
- 6 January 2026
- Published by Springer Nature in Nature Reviews Electrical Engineering
- Vol. 3 (2) , 111-122
Recycling power semiconductor devices
- 6 January 2026
- Published by Springer Nature in Nature Reviews Electrical Engineering
- Vol. 3 (2) , 111-122
Open AccessRecycling power semiconductor devices
- Open Access
- 28 August 2025
- Published by Wiley in Annalen der Physik
- Vol. 537 (11)
Dispersion of First Sound in a Weakly Interacting Ultracold Fermi Liquid
At low temperature, a normal gas of unpaired spin‐1/2 fermions is one of the cleanest realizations of a Fermi liquid. It is described by Landau's theory, where no phenomenological parameters are needed as the quasiparticle interaction function can be computed perturbatively in powers of the scattering length , the sole parameter of the short‐range interparticle interactions. Obtaining an accurate solution of the transport equation nevertheless requires a careful treatment of the collision kernel, as the uncontrolled error made by the relaxation time approximations increases when the temperature drops below the Fermi temperature. Here, sound waves in the hydrodynamic regime are studied up to second order in the Chapman‐Enskog's expansion. It is found that the frequency of the sound wave is shifted above its linear departure as where and are the speed and wavenumber of the sound wave and the typical collision time scales as . Besides the shear viscosity, the coefficient is described by a single second‐order collision time, which is computed exactly from an analytical solution of the transport equation, resulting in a positive dispersion . The results suggest that ultracold atomic Fermi gases are an ideal experimental system for quantitative tests of second‐order hydrodynamics.
- 28 August 2025
- Published by Wiley in Annalen der Physik
- Vol. 537 (11)
Open AccessDispersion of First Sound in a Weakly Interacting Ultracold Fermi Liquid
At low temperature, a normal gas of unpaired spin‐1/2 fermions is one of the cleanest realizations of a Fermi liquid. It is described by Landau's theory, where no phenomenological parameters are needed as the quasiparticle interaction function can be computed perturbatively in powers of the scattering length , the sole parameter of the short‐range interparticle interactions. Obtaining an accurate solution of the transport equation nevertheless requires a careful treatment of the collision kernel, as the uncontrolled error made by the relaxation time approximations increases when the temperature drops below the Fermi temperature. Here, sound waves in the hydrodynamic regime are studied up to second order in the Chapman‐Enskog's expansion. It is found that the frequency of the sound wave is shifted above its linear departure as where and are the speed and wavenumber of the sound wave and the typical collision time scales as . Besides the shear viscosity, the coefficient is described by a single second‐order collision time, which is computed exactly from an analytical solution of the transport equation, resulting in a positive dispersion . The results suggest that ultracold atomic Fermi gases are an ideal experimental system for quantitative tests of second‐order hydrodynamics.
- 27 April 2025
- Published by Springer Nature
- p. 460-471
An Impedance Shaping Method for Suppressing Low-Frequency Oscillations in Power Systems
- 27 April 2025
- Published by Springer Nature
- p. 460-471
An Impedance Shaping Method for Suppressing Low-Frequency Oscillations in Power Systems
- 18 April 2025
- Published by Springer Nature in Electrical Engineering
- Vol. 107 (8) , 11159-11170
Enhanced active damping control with phase compensation for mitigating high-frequency oscillations in grid-connected systems
- 18 April 2025
- Published by Springer Nature in Electrical Engineering
- Vol. 107 (8) , 11159-11170
Enhanced active damping control with phase compensation for mitigating high-frequency oscillations in grid-connected systems
- 28 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 40 (4) , 2994-3006
Stability Enhancement of Inverter-Current Feedback Grid-Following Inverters Using a Passivity-Based Voltage Controller
Grid-following inverters remain the primary interface for modern renewable energy systems due to their strong power output performance. As the global demand for clean and efficient energy conversion increases, optimizing the stability of inverter systems is crucial for integrating renewable sources into the power grid. In certain energy conversion scenarios, current sensors are placed on the inverter side due to equipment constraints and space limitations, which can impact the stability of the inverter. Although the stability of inverter-side current feedback (ICF) configurations has been studied, methods to further enhance their stability remain underexplored. In this paper, the stability of ICF grid-following inverters is analyzed using a passivity-based design approach, focusing on a point of common coupling voltage controller. The proposed controller is thoroughly analyzed, and a detailed design strategy is presented to ensure stability under varying grid impedance conditions. Experimental results validate the theoretical analysis, demonstrating the effectiveness of the proposed design in enhancing the stability of ICF grid-following inverters. These advancements contribute to improving energy conversion efficiency and reliability.
- 28 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 40 (4) , 2994-3006
Stability Enhancement of Inverter-Current Feedback Grid-Following Inverters Using a Passivity-Based Voltage Controller
Grid-following inverters remain the primary interface for modern renewable energy systems due to their strong power output performance. As the global demand for clean and efficient energy conversion increases, optimizing the stability of inverter systems is crucial for integrating renewable sources into the power grid. In certain energy conversion scenarios, current sensors are placed on the inverter side due to equipment constraints and space limitations, which can impact the stability of the inverter. Although the stability of inverter-side current feedback (ICF) configurations has been studied, methods to further enhance their stability remain underexplored. In this paper, the stability of ICF grid-following inverters is analyzed using a passivity-based design approach, focusing on a point of common coupling voltage controller. The proposed controller is thoroughly analyzed, and a detailed design strategy is presented to ensure stability under varying grid impedance conditions. Experimental results validate the theoretical analysis, demonstrating the effectiveness of the proposed design in enhancing the stability of ICF grid-following inverters. These advancements contribute to improving energy conversion efficiency and reliability.
- 10 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (9) , 10962-10975
A New Parameter Tuning Method for Generalized Multiresonant Current Controllers in Grid-Connected Inverters
Multiresonant controllers are widely used in the current control of grid-connected converters due to their accurate tracking of reference sinusoidal signals containing high harmonic counts. However, the performance of multiresonant controllers relies heavily on the suitability of the parameter design. In this paper, a generalized multiresonant controller that unifies various existing resonant controllers is proposed, which achieves the decoupling of the proportional terms, eliminates the need for online operation of trigonometric functions, and obtains a more extensive range of regulation capability. Furthermore, a new multioptimized parameter tuning method that considers several performance indexes is proposed to utilize the generalized resonant controller's performance fully. Finally, based on the proposed method, a generalized multiresonant controller is designed for $ {\bm {L}}$ -type and $ {\bm {LCL}}$ -type grid-connected inverters, respectively, demonstrating the universality of the proposed approach. Simulation and experimental results validate the effectiveness of the proposed method.
- 10 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (9) , 10962-10975
A New Parameter Tuning Method for Generalized Multiresonant Current Controllers in Grid-Connected Inverters
Multiresonant controllers are widely used in the current control of grid-connected converters due to their accurate tracking of reference sinusoidal signals containing high harmonic counts. However, the performance of multiresonant controllers relies heavily on the suitability of the parameter design. In this paper, a generalized multiresonant controller that unifies various existing resonant controllers is proposed, which achieves the decoupling of the proportional terms, eliminates the need for online operation of trigonometric functions, and obtains a more extensive range of regulation capability. Furthermore, a new multioptimized parameter tuning method that considers several performance indexes is proposed to utilize the generalized resonant controller's performance fully. Finally, based on the proposed method, a generalized multiresonant controller is designed for $ {\bm {L}}$ -type and $ {\bm {LCL}}$ -type grid-connected inverters, respectively, demonstrating the universality of the proposed approach. Simulation and experimental results validate the effectiveness of the proposed method.
- 2 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (8) , 9494-9513
Harmonic Spectra Analysis of Digital SPWM in VSI With DC Bus Ripple and Dead-Time Effects
This article presents a closed-form analytical solution to the harmonic spectrum of output voltage of a single-phase H-bridge inverter, and gives the precise harmonic spectrum considering the effects of dead time and dc bus voltage ripple in a digitally controlled system. Since the H-bridge is the basic block in converters, this solution and spectrum can be extended and applied to a variety of pulsewidth-modulation-based topologies. The interaction between modulation waveform and triangular during the modulation process is fully analyzed from a mathematical perspective so that the combined effects of digital sampling, dead time, and dc bus voltage ripple on the output voltage are summarized in time and frequency domains. Furthermore, the presented harmonic spectra do not need to judge the current polarity in calculation, which means that the exact amplitude and phase of each output harmonic can be obtained accurately, providing the important theoretical basis for system parameter design and specific harmonic compensation or elimination. The presented analysis results are verified by simulations and experiments.
- 2 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (8) , 9494-9513
Harmonic Spectra Analysis of Digital SPWM in VSI With DC Bus Ripple and Dead-Time Effects
This article presents a closed-form analytical solution to the harmonic spectrum of output voltage of a single-phase H-bridge inverter, and gives the precise harmonic spectrum considering the effects of dead time and dc bus voltage ripple in a digitally controlled system. Since the H-bridge is the basic block in converters, this solution and spectrum can be extended and applied to a variety of pulsewidth-modulation-based topologies. The interaction between modulation waveform and triangular during the modulation process is fully analyzed from a mathematical perspective so that the combined effects of digital sampling, dead time, and dc bus voltage ripple on the output voltage are summarized in time and frequency domains. Furthermore, the presented harmonic spectra do not need to judge the current polarity in calculation, which means that the exact amplitude and phase of each output harmonic can be obtained accurately, providing the important theoretical basis for system parameter design and specific harmonic compensation or elimination. The presented analysis results are verified by simulations and experiments.