Angelica Svalkvist
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Angelica Svalkvist has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
- Magnus Båth
University of Gothenburg, Sahlgrenska Academy, Institute of Clinical Sciences, Department of Medical Radiation Sciences, Gothenburg, Sweden
11 shared publications - Jenny Vikgren
Department of Radiology, Institute of Clinical Sciences, The Sahlgrenska Academy at University of Gothenburg, SE-413 45 Gothenburg, Sweden Department of Radiology, Sahlgrenska University Hospital, SE-413 45 Gothenburg, Sweden
3 shared publications Magnus Båth
Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Sweden
3 shared publications- Åse Allansdotter Johnsson
University of Gothenburg, Sahlgrenska Academy, Institute of Clinical Sciences, Department of Radiology, Gothenburg, Sweden
3 shared publications Agneta Flinck
Department of Radiology, Sahlgrenska Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg
2 shared publicationsChristina Söderman
Department of Radiation Physics, Institute of Clinical Sciences, Sahlgrenska Academy at University of Gothenburg, Sweden
2 shared publications
Latest Publications
- Open Access
- 13 March 2026
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 202 (3–4) , 114-129
Survey of radiological optimization processes in Swedish hospitals—similarities and differences between different modalities
The optimization process is an important part of image-based diagnostics and treatments, requiring collaboration among medical physicists, radiologists, physicians, radiographers, nurses, engineers, and vendors. However, such teamwork can be challenging in some departments. In spring 2024, questionnaires were sent to Swedish medical physicists working with radiology, interventional radiology, or surgery facilities using radiological equipment. The surveys included modality-specific questions about optimization processes. The aim was to explore differences in optimization processes between modalities and departments, identify common challenges, and understand factors facilitating effective optimization. Results showed variations in optimization processes across different modalities, where successful optimization processes were harder to achieve for stationary fluoroscopy systems and mobile fluoroscopy systems than for the other modalities. Common challenges included limited time and lack of knowledge about image quality issues, while close collaboration, continuous meetings with focus on optimization, and good communication were mentioned as important factors for obtaining successful optimization processes.
- 13 March 2026
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 202 (3–4) , 114-129
Open AccessSurvey of radiological optimization processes in Swedish hospitals—similarities and differences between different modalities
The optimization process is an important part of image-based diagnostics and treatments, requiring collaboration among medical physicists, radiologists, physicians, radiographers, nurses, engineers, and vendors. However, such teamwork can be challenging in some departments. In spring 2024, questionnaires were sent to Swedish medical physicists working with radiology, interventional radiology, or surgery facilities using radiological equipment. The surveys included modality-specific questions about optimization processes. The aim was to explore differences in optimization processes between modalities and departments, identify common challenges, and understand factors facilitating effective optimization. Results showed variations in optimization processes across different modalities, where successful optimization processes were harder to achieve for stationary fluoroscopy systems and mobile fluoroscopy systems than for the other modalities. Common challenges included limited time and lack of knowledge about image quality issues, while close collaboration, continuous meetings with focus on optimization, and good communication were mentioned as important factors for obtaining successful optimization processes.
- Open Access
- 13 March 2026
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 202 (3–4) , 113
Optimisation in X-ray and molecular imaging 2025—editorial
- 13 March 2026
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 202 (3–4) , 113
Open AccessOptimisation in X-ray and molecular imaging 2025—editorial
- Open Access
- 24 August 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (9) , e70221
Impact of deep learning model uncertainty on manual corrections to MRI‐based auto‐segmentation in prostate cancer radiotherapy
Background: Deep learning (DL)‐based organ segmentation is increasingly used in radiotherapy. While methods exist to generate voxel‐wise uncertainty maps from DL‐based auto‐segmentation models, these maps are rarely presented to clinicians. Purpose: This study aimed to evaluate the impact of DL‐generated uncertainty maps on experienced radiation oncologists during the manual correction of DL‐based auto‐segmentation for prostate radiotherapy. Methods: Two nnUNet DL models were trained with 10‐fold cross‐validation on a dataset of 434 patient cases undergoing ultra‐hypofractionated MRI‐only radiotherapy for prostate cancer. The models performed prostate clinical target volume (CTV) and rectum segmentation. Each cross‐validation model was evaluated on an independent test set of 35 patient cases. Segmentation uncertainty was calculated voxel‐wise as the SoftMax standard deviation (0–0.5, n = 10) and visualized as a fixed scale color‐coded map. Four experienced oncologists were asked to: Step 1: Rate the quality of and confidence in the DL segmentations using a four‐ and five‐point Likert scale, respectively, and edit the segmentations without access to the uncertainty map. Step 2: Repeat step 1 after at least 4 weeks, but this time with the color‐coded uncertainty map available. Oncologists were asked to blend the uncertainty map with the DL segmentation and MRI volume. Segmentation edit time was recorded for both steps. In step 2, oncologists also provided free‐text feedback on the benefits and drawbacks of using the uncertainty map during segmentation. A histogram analysis was performed to compare the number of voxels edited between step 1 and step 2 for different uncertainty levels (bins with 0.1 intervals). Results: The DL models achieved high‐quality segmentations with a mean Dice coefficient per oncologist of 0.97–0.99, calculated between edited and unedited segmentation in step 1 for the prostate CTV and rectum. While the overall quality rating for rectum segmentations decreased slightly on a group level in step 2 compared to step 1, individual responses varied. Some oncologists rated the quality higher for the prostate CTV segmentation with the uncertainty map present, while others rated it lower. Similarly, confidence ratings varied across oncologists for prostate CTV and rectum. Decreased segmentation time was recorded for three oncologists using uncertainty maps, saving 1–2 min per patient case, corresponding to 14%–33% time reduction. Three oncologists found the uncertainty maps helpful, and one reported benefit was the ability to identify regions of interest more quickly. The histogram analysis had fewer voxel edits in regions of low uncertainty in step 2 compared to step 1. Specifically, 50% fewer voxel edits were recorded for the uncertainty region 0.0–0.1, suggesting increased trust in the DL model's prediction in these areas. Conclusions: Presenting DL uncertainty information to experienced radiation oncologists influences their decision‐making, quality perception, and confidence in the DL segmentations. Regions with low uncertainty were less likely to be edited, indicating increased reliance on the model's predictions. Additionally, uncertainty maps can improve efficiency by reducing segmentation time. DL‐based segmentation uncertainty can be a valuable tool in clinical practice, enhancing the efficiency of radiotherapy planning.
- 24 August 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (9) , e70221
Open AccessImpact of deep learning model uncertainty on manual corrections to MRI‐based auto‐segmentation in prostate cancer radiotherapy
Background: Deep learning (DL)‐based organ segmentation is increasingly used in radiotherapy. While methods exist to generate voxel‐wise uncertainty maps from DL‐based auto‐segmentation models, these maps are rarely presented to clinicians. Purpose: This study aimed to evaluate the impact of DL‐generated uncertainty maps on experienced radiation oncologists during the manual correction of DL‐based auto‐segmentation for prostate radiotherapy. Methods: Two nnUNet DL models were trained with 10‐fold cross‐validation on a dataset of 434 patient cases undergoing ultra‐hypofractionated MRI‐only radiotherapy for prostate cancer. The models performed prostate clinical target volume (CTV) and rectum segmentation. Each cross‐validation model was evaluated on an independent test set of 35 patient cases. Segmentation uncertainty was calculated voxel‐wise as the SoftMax standard deviation (0–0.5, n = 10) and visualized as a fixed scale color‐coded map. Four experienced oncologists were asked to: Step 1: Rate the quality of and confidence in the DL segmentations using a four‐ and five‐point Likert scale, respectively, and edit the segmentations without access to the uncertainty map. Step 2: Repeat step 1 after at least 4 weeks, but this time with the color‐coded uncertainty map available. Oncologists were asked to blend the uncertainty map with the DL segmentation and MRI volume. Segmentation edit time was recorded for both steps. In step 2, oncologists also provided free‐text feedback on the benefits and drawbacks of using the uncertainty map during segmentation. A histogram analysis was performed to compare the number of voxels edited between step 1 and step 2 for different uncertainty levels (bins with 0.1 intervals). Results: The DL models achieved high‐quality segmentations with a mean Dice coefficient per oncologist of 0.97–0.99, calculated between edited and unedited segmentation in step 1 for the prostate CTV and rectum. While the overall quality rating for rectum segmentations decreased slightly on a group level in step 2 compared to step 1, individual responses varied. Some oncologists rated the quality higher for the prostate CTV segmentation with the uncertainty map present, while others rated it lower. Similarly, confidence ratings varied across oncologists for prostate CTV and rectum. Decreased segmentation time was recorded for three oncologists using uncertainty maps, saving 1–2 min per patient case, corresponding to 14%–33% time reduction. Three oncologists found the uncertainty maps helpful, and one reported benefit was the ability to identify regions of interest more quickly. The histogram analysis had fewer voxel edits in regions of low uncertainty in step 2 compared to step 1. Specifically, 50% fewer voxel edits were recorded for the uncertainty region 0.0–0.1, suggesting increased trust in the DL model's prediction in these areas. Conclusions: Presenting DL uncertainty information to experienced radiation oncologists influences their decision‐making, quality perception, and confidence in the DL segmentations. Regions with low uncertainty were less likely to be edited, indicating increased reliance on the model's predictions. Additionally, uncertainty maps can improve efficiency by reducing segmentation time. DL‐based segmentation uncertainty can be a valuable tool in clinical practice, enhancing the efficiency of radiotherapy planning.
- Open Access
- 28 October 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 12 (S1) , S13007-15
Lung nodule localization and size estimation on chest tomosynthesis
Digital tomosynthesis (DTS) of the chest is a relatively modern modality, based on conventional X-ray techniques, which allows superior visualization of anatomical structures and pathological findings in multiple sections that would otherwise be seen in the same projection in a standard posterior-anterior chest X-ray.1,2 The ability to isolate small structures is ideal for the visualization of lung nodules. A lung nodule is a relatively well-defined approximately rounded opacity measuring up to 3 cm in diameter within the lung parenchyma.3 It is known that nodule size, morphology, nodule location, and nodule growth rate are characteristics associated with the risk of malignancy.4 Consequently, nodule size estimate is an important factor in nodule assessment in all major recommended algorithms.5 – 7
- 28 October 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 12 (S1) , S13007-15
Open AccessLung nodule localization and size estimation on chest tomosynthesis
Digital tomosynthesis (DTS) of the chest is a relatively modern modality, based on conventional X-ray techniques, which allows superior visualization of anatomical structures and pathological findings in multiple sections that would otherwise be seen in the same projection in a standard posterior-anterior chest X-ray.1,2 The ability to isolate small structures is ideal for the visualization of lung nodules. A lung nodule is a relatively well-defined approximately rounded opacity measuring up to 3 cm in diameter within the lung parenchyma.3 It is known that nodule size, morphology, nodule location, and nodule growth rate are characteristics associated with the risk of malignancy.4 Consequently, nodule size estimate is an important factor in nodule assessment in all major recommended algorithms.5 – 7
- Open Access
- 14 September 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 12 (S1) , S13004-14
Breathing motion compensation in chest tomosynthesis: evaluation of the effect on image quality and presence of artifacts
Chest tomosynthesis (CTS) is an X-ray examination that has been shown to be a promising imaging technique in chest radiology.1 – 3 Although conventional chest radiography (CXR) remains the most common diagnostic examination for pulmonary diseases, with the advantages of low cost and low radiation dose, CTS has shown an increased sensitivity in the detection of pulmonary nodules.1,4 The increased sensitivity in the detection of these lesions is due to the tomographic technique used in CTS resulting in section images of the chest where the impact of overlaying anatomy is reduced.5
- 14 September 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 12 (S1) , S13004-14
Open AccessBreathing motion compensation in chest tomosynthesis: evaluation of the effect on image quality and presence of artifacts
Chest tomosynthesis (CTS) is an X-ray examination that has been shown to be a promising imaging technique in chest radiology.1 – 3 Although conventional chest radiography (CXR) remains the most common diagnostic examination for pulmonary diseases, with the advantages of low cost and low radiation dose, CTS has shown an increased sensitivity in the detection of pulmonary nodules.1,4 The increased sensitivity in the detection of these lesions is due to the tomographic technique used in CTS resulting in section images of the chest where the impact of overlaying anatomy is reduced.5
- Open Access
- 4 March 2021
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 195 (3-4) , 372-377
VIEWDEX 3.0—RECENT DEVELOPMENT OF A SOFTWARE APPLICATION FACILITATING ASSESSMENT OF IMAGE QUALITY AND OBSERVER PERFORMANCE
ViewDEX (Viewer for Digital Evaluation of X-ray Images) is an image viewer compatible with Digital Imaging and Communications in Medicine (DICOM) that has been especially designed to facilitate image perception and observer performance studies within medical imaging. The software was first released in 2004 and since then a continuous development has been ongoing. One of the major drawbacks of previous versions of ViewDEX has been that they have lacked functionality enabling the possibility to evaluate multiple images and/or image stacks simultaneously. This functionality is especially requested by researchers working with modalities, where an image acquisition can result in multiple image stacks (e.g. axial, coronal and sagittal reformations in computed tomography). In ViewDEX 3.0 this functionality has been added and it is now possible to perform image evaluations of multiple images and/or image stacks simultaneously, by using multiple monitors and/or multiple image canvases in monitors. Additionally, some of the previously available functionality has been updated and improved. This paper describes the recent developments of ViewDEX 3.0.
- 4 March 2021
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 195 (3-4) , 372-377
Open AccessVIEWDEX 3.0—RECENT DEVELOPMENT OF A SOFTWARE APPLICATION FACILITATING ASSESSMENT OF IMAGE QUALITY AND OBSERVER PERFORMANCE
ViewDEX (Viewer for Digital Evaluation of X-ray Images) is an image viewer compatible with Digital Imaging and Communications in Medicine (DICOM) that has been especially designed to facilitate image perception and observer performance studies within medical imaging. The software was first released in 2004 and since then a continuous development has been ongoing. One of the major drawbacks of previous versions of ViewDEX has been that they have lacked functionality enabling the possibility to evaluate multiple images and/or image stacks simultaneously. This functionality is especially requested by researchers working with modalities, where an image acquisition can result in multiple image stacks (e.g. axial, coronal and sagittal reformations in computed tomography). In ViewDEX 3.0 this functionality has been added and it is now possible to perform image evaluations of multiple images and/or image stacks simultaneously, by using multiple monitors and/or multiple image canvases in monitors. Additionally, some of the previously available functionality has been updated and improved. This paper describes the recent developments of ViewDEX 3.0.
- Open Access
- 31 October 2020
- Published by MDPI AG in Diagnostics
- Vol. 10 (11) , 892
Comparison of Magnetic Resonance Angiography and Digital Subtraction Angiography for the Assessment of Infrapopliteal Arterial Occlusive Lesions, Based on the TASC II Classification Criteria
This paper aimed to study the agreement and repeatability, both intra- and interobserver, of infrapopliteal lesion assessment with magnetic resonance angiography (MRA), using the TransAtlantic Inter-Society Consensus (TASC) II criteria, with perioperative digital subtraction angiography (DSA) as a reference. Sixty-eight patients with an MRA preceding an endovascular infrapopliteal revascularization were included. Preoperative MRAs and perioperative DSAs were evaluated in random order by three independent observers using the TASC II classification. The results were analyzed using visual grading characteristics (VGC) analysis and Krippendorff’s α. No systematic difference was found between modalities: area under the VGC curve (AUCVGC) = 0.48 (p = 0.58) or intraobserver; AUCVGC for Observer 1 and 2 respectively, 0.49 (p = 0.85) and 0.53 (p = 0.52) for MRA compared with 0.54 (p = 0.30) and 0.49 (p = 0.81) for DSA. Interobserver differences were seen: AUCVGC of 0.63 (p < 0.01) for DSA and 0.80 (p < 0.01) for MRA. These results were confirmed using Krippendorff’s α for the three observers showing 0.13 (95% confidence interval (CI) −0.07–0.31) for MRA and 0.39 (95% CI 0.23–0.53) for DSA. Poor interobserver agreement was also found in the choice of a target vessel on preoperative MRA: Krippendorff’s α = 0.19 (95% CI 0.01‒0.36). In conclusion, infrapopliteal lesions can be reliably determined on preoperative MRA, but interobserver variability regarding the choice of a target vessel is a major concern that appears to affect the overall TASC II grade.
- 31 October 2020
- Published by MDPI AG in Diagnostics
- Vol. 10 (11) , 892
Open AccessComparison of Magnetic Resonance Angiography and Digital Subtraction Angiography for the Assessment of Infrapopliteal Arterial Occlusive Lesions, Based on the TASC II Classification Criteria
This paper aimed to study the agreement and repeatability, both intra- and interobserver, of infrapopliteal lesion assessment with magnetic resonance angiography (MRA), using the TransAtlantic Inter-Society Consensus (TASC) II criteria, with perioperative digital subtraction angiography (DSA) as a reference. Sixty-eight patients with an MRA preceding an endovascular infrapopliteal revascularization were included. Preoperative MRAs and perioperative DSAs were evaluated in random order by three independent observers using the TASC II classification. The results were analyzed using visual grading characteristics (VGC) analysis and Krippendorff’s α. No systematic difference was found between modalities: area under the VGC curve (AUCVGC) = 0.48 (p = 0.58) or intraobserver; AUCVGC for Observer 1 and 2 respectively, 0.49 (p = 0.85) and 0.53 (p = 0.52) for MRA compared with 0.54 (p = 0.30) and 0.49 (p = 0.81) for DSA. Interobserver differences were seen: AUCVGC of 0.63 (p < 0.01) for DSA and 0.80 (p < 0.01) for MRA. These results were confirmed using Krippendorff’s α for the three observers showing 0.13 (95% confidence interval (CI) −0.07–0.31) for MRA and 0.39 (95% CI 0.23–0.53) for DSA. Poor interobserver agreement was also found in the choice of a target vessel on preoperative MRA: Krippendorff’s α = 0.19 (95% CI 0.01‒0.36). In conclusion, infrapopliteal lesions can be reliably determined on preoperative MRA, but interobserver variability regarding the choice of a target vessel is a major concern that appears to affect the overall TASC II grade.
- 30 September 2016
- Published by SAGE Publications in Acta Radiologica
- Vol. 58 (4) , 408-413
Evaluation of a corrected implementation of a method of simulating pulmonary nodules in chest tomosynthesis
Background: A method of simulating pulmonary nodules in tomosynthesis images has previously been developed and evaluated. An unknown feature of a rounding function included in the computer code was later found to introduce an artifact, affecting simulated nodules in low-signal regions of the images. The computer code has now been corrected. Purpose: To perform a thorough evaluation of the corrected nodule-simulation method, comparing the detection rate and visual appearance of artificial nodules with those of real nodules in an observer performance experiment. Material and Methods: A cohort of 64 patients with a total of 129 pulmonary nodules was used in the study. Artificial nodules, each matching a corresponding real nodule by size, attenuation, and anatomical location, were generated and simulated into the tomosynthesis images of the different patients. The detection rate and visual appearance of artificial nodules generated using both the corrected and uncorrected computer code were compared to those of real nodules. The results were evaluated using modified receiver operating characteristic (ROC) analyses. Results: The difference in detection rate between artificial and real nodules slightly increased using the corrected computer code (uncorrected code: area under the curve [AUC], 0.47; 95% CI, 0.43–0.51; corrected code: AUC, 0.42; 95% CI, 0.38–0.46). The visual appearance was however substantially improved using the corrected computer code (uncorrected code: AUC, 0.70; 95% CI, 0.63–0.76; corrected code: AUC, 0.49; 95% CI, 0.29–0.65). Conclusion: The computer code including a correct rounding function generates simulated nodules that are more visually realistic than simulated nodules generated using the uncorrected computer code, but have a slightly different detection rate compared to real nodules.
- 30 September 2016
- Published by SAGE Publications in Acta Radiologica
- Vol. 58 (4) , 408-413
Evaluation of a corrected implementation of a method of simulating pulmonary nodules in chest tomosynthesis
Background: A method of simulating pulmonary nodules in tomosynthesis images has previously been developed and evaluated. An unknown feature of a rounding function included in the computer code was later found to introduce an artifact, affecting simulated nodules in low-signal regions of the images. The computer code has now been corrected. Purpose: To perform a thorough evaluation of the corrected nodule-simulation method, comparing the detection rate and visual appearance of artificial nodules with those of real nodules in an observer performance experiment. Material and Methods: A cohort of 64 patients with a total of 129 pulmonary nodules was used in the study. Artificial nodules, each matching a corresponding real nodule by size, attenuation, and anatomical location, were generated and simulated into the tomosynthesis images of the different patients. The detection rate and visual appearance of artificial nodules generated using both the corrected and uncorrected computer code were compared to those of real nodules. The results were evaluated using modified receiver operating characteristic (ROC) analyses. Results: The difference in detection rate between artificial and real nodules slightly increased using the corrected computer code (uncorrected code: area under the curve [AUC], 0.47; 95% CI, 0.43–0.51; corrected code: AUC, 0.42; 95% CI, 0.38–0.46). The visual appearance was however substantially improved using the corrected computer code (uncorrected code: AUC, 0.70; 95% CI, 0.63–0.76; corrected code: AUC, 0.49; 95% CI, 0.29–0.65). Conclusion: The computer code including a correct rounding function generates simulated nodules that are more visually realistic than simulated nodules generated using the uncorrected computer code, but have a slightly different detection rate compared to real nodules.
- 27 January 2016
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 169 (1-4) , 38-45
VIEWDEX: A STATUS REPORT
ViewDEX (Viewer for Digital Evaluation of X-ray images) is an image viewer and task manager suitable for research and optimisation tasks in medical imaging. The software has undergone continuous development during more than a decade and has during this time period been used in numerous studies. ViewDEX is DICOM compatible, and the features of the interface (tasks, image handling and functionality) are general and flexible. The set-up of a study is determined by altering properties in a text-editable file, enabling easy and flexible configuration. ViewDEX is developed in Java and can run from any disc area connected to a computer. It is free to use for non-commercial purposes and can be downloaded from http://www.vgregion.se/sas/viewdex. The purposes of the present article are to give a short overview of the development of ViewDEX and to describe recent updates of the software. In addition, a description on how to configure a viewing session in ViewDEX is provided.
- 27 January 2016
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 169 (1-4) , 38-45
VIEWDEX: A STATUS REPORT
ViewDEX (Viewer for Digital Evaluation of X-ray images) is an image viewer and task manager suitable for research and optimisation tasks in medical imaging. The software has undergone continuous development during more than a decade and has during this time period been used in numerous studies. ViewDEX is DICOM compatible, and the features of the interface (tasks, image handling and functionality) are general and flexible. The set-up of a study is determined by altering properties in a text-editable file, enabling easy and flexible configuration. ViewDEX is developed in Java and can run from any disc area connected to a computer. It is free to use for non-commercial purposes and can be downloaded from http://www.vgregion.se/sas/viewdex. The purposes of the present article are to give a short overview of the development of ViewDEX and to describe recent updates of the software. In addition, a description on how to configure a viewing session in ViewDEX is provided.
- 15 December 2015
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 169 (1-4) , 274-280
EFFECTIVE DOSE TO PATIENTS FROM THORACIC SPINE EXAMINATIONS WITH TOMOSYNTHESIS
The purposes of the present work were to calculate the average effective dose to patients from lateral tomosynthesis examinations of the thoracic spine, compare the results with the corresponding conventional examination and to determine a conversion factor between dose-area product (DAP) and effective dose for the tomosynthesis examination. Thoracic spine examinations from 17 patients were included in the study. The registered DAP and information about the field size for each projection radiograph were, together with patient height and mass, used to calculate the effective dose for each projection radiograph. The total effective doses for the tomosynthesis examinations were obtained by adding the effective doses from the 60 projection radiographs included in the examination. The mean effective dose was 0.47 mSv (range 0.24–0.81 mSv) for the tomosynthesis examinations and 0.20 mSv (range 0.07–0.29 mSv) for the corresponding conventional examinations (anteroposterior + left lateral projection). For the tomosynthesis examinations, a conversion factor between total DAP and effective dose of 0.092 mSv Gycm−2 was obtained.
- 15 December 2015
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 169 (1-4) , 274-280
EFFECTIVE DOSE TO PATIENTS FROM THORACIC SPINE EXAMINATIONS WITH TOMOSYNTHESIS
The purposes of the present work were to calculate the average effective dose to patients from lateral tomosynthesis examinations of the thoracic spine, compare the results with the corresponding conventional examination and to determine a conversion factor between dose-area product (DAP) and effective dose for the tomosynthesis examination. Thoracic spine examinations from 17 patients were included in the study. The registered DAP and information about the field size for each projection radiograph were, together with patient height and mass, used to calculate the effective dose for each projection radiograph. The total effective doses for the tomosynthesis examinations were obtained by adding the effective doses from the 60 projection radiographs included in the examination. The mean effective dose was 0.47 mSv (range 0.24–0.81 mSv) for the tomosynthesis examinations and 0.20 mSv (range 0.07–0.29 mSv) for the corresponding conventional examinations (anteroposterior + left lateral projection). For the tomosynthesis examinations, a conversion factor between total DAP and effective dose of 0.092 mSv Gycm−2 was obtained.