Joong Ho Shin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Joong Ho Shin has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
Won Han
8 shared publications- Balamurugan Thangavel
Major of Biomedical Engineering, Division of Smart Healthcare, College of Information Technology and Convergence, Pukyong National University, Busan 48513, Republic of Korea
7 shared publications Hyo-Eun Kang
3 shared publicationsSe Been Park
Industry 4.0 Convergence Bionics Engineering
3 shared publications- Bui The Huy
Major of Biomedical Engineering, Division of Smart Healthcare, College of Information Technology and Convergence, Pukyong National University, Republic of Korea
2 shared publications Ganghak Lee
2 shared publications
Latest Publications
- 14 August 2026
- Published by American Chemical Society (ACS) in ACS Sensors
Field-Deployable Paper-Based Detection of Vibrio vulnificus via Mechanically Automated Sequential RPA/CRISPR-Cas12a
Vibrio vulnificus (V. vulnificus) is a highly virulent marine pathogen that causes severe infections, including sepsis and necrotizing fasciitis, with high fatality rates in susceptible individuals. Rapid and sensitive on-site detection is therefore essential, yet existing methods often depend on laboratory-based equipment and trained personnel, limiting field applicability. Here, we present an automated, paper-based RPA/CRISPR-Cas12a diagnostic platform that integrates a microfluidic paper pad with a spiral-spring-driven mechanical actuator. The device enables sequential execution of recombinase polymerase amplification (RPA), CRISPR-Cas12a-mediated detection, and lateral flow assay (LFA) readout through a single user-initiated winding step, without the need for external power or instrumentation. The multistep process was achieved through automatic reconfiguration of the paper pads, enabling pipette-free transfer of RPA amplicons from the paper-based RPA pad to the paper-based CRISPR pad, followed by transfer of the reporter probes to the LFA strip. The paper-based system is preloaded with lyophilized reagents and designed to autonomously control fluid flow and reaction timing. Targeting the vvhA gene specific to V. vulnificus, the platform achieved a limit of detection of 1 colony-forming unit per reaction (CFU/reaction) in pure cultures. This sensitivity was consistently reproduced in gill swab samples from oysters exposed to artificially contaminated seawater at 20 CFU/mL, confirming that reliable detection was achievable in oyster gill swabs under these conditions. Overall, this work establishes a fully mechanical, instrument-free RPA/CRISPR-based diagnostic system for V. vulnificus, offering a rapid, portable, and highly sensitive approach for point-of-care testing and food safety applications.
- 14 August 2026
- Published by American Chemical Society (ACS) in ACS Sensors
Field-Deployable Paper-Based Detection of Vibrio vulnificus via Mechanically Automated Sequential RPA/CRISPR-Cas12a
Vibrio vulnificus (V. vulnificus) is a highly virulent marine pathogen that causes severe infections, including sepsis and necrotizing fasciitis, with high fatality rates in susceptible individuals. Rapid and sensitive on-site detection is therefore essential, yet existing methods often depend on laboratory-based equipment and trained personnel, limiting field applicability. Here, we present an automated, paper-based RPA/CRISPR-Cas12a diagnostic platform that integrates a microfluidic paper pad with a spiral-spring-driven mechanical actuator. The device enables sequential execution of recombinase polymerase amplification (RPA), CRISPR-Cas12a-mediated detection, and lateral flow assay (LFA) readout through a single user-initiated winding step, without the need for external power or instrumentation. The multistep process was achieved through automatic reconfiguration of the paper pads, enabling pipette-free transfer of RPA amplicons from the paper-based RPA pad to the paper-based CRISPR pad, followed by transfer of the reporter probes to the LFA strip. The paper-based system is preloaded with lyophilized reagents and designed to autonomously control fluid flow and reaction timing. Targeting the vvhA gene specific to V. vulnificus, the platform achieved a limit of detection of 1 colony-forming unit per reaction (CFU/reaction) in pure cultures. This sensitivity was consistently reproduced in gill swab samples from oysters exposed to artificially contaminated seawater at 20 CFU/mL, confirming that reliable detection was achievable in oyster gill swabs under these conditions. Overall, this work establishes a fully mechanical, instrument-free RPA/CRISPR-based diagnostic system for V. vulnificus, offering a rapid, portable, and highly sensitive approach for point-of-care testing and food safety applications.
- 2 September 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 13 (41) , 13256-13271
Surfactant-free synthesis of gold nanoparticle-decorated poly( o -phenylenediamine) sub-microspheres as surface-confined signaling probes for label-free electrochemical immunosensing of E. coli O157:H7
Surfactant-free AuNPs@PoPD composites act as dual-function redox probes and antibody matrices for label-free pathogen detection at physiological pH for point-of-care diagnosis.
- 2 September 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 13 (41) , 13256-13271
Surfactant-free synthesis of gold nanoparticle-decorated poly( o -phenylenediamine) sub-microspheres as surface-confined signaling probes for label-free electrochemical immunosensing of E. coli O157:H7
Surfactant-free AuNPs@PoPD composites act as dual-function redox probes and antibody matrices for label-free pathogen detection at physiological pH for point-of-care diagnosis.
- Open Access
CMC-Based Injectable Hydrogels Crosslinked by Diels–Alder Chemistry for Wound Healing Applications
Chronic wounds disrupt natural healing and tissue regeneration, posing a major challenge in healthcare. Conventional wound care often lacks effective drug delivery, tissue integration, infection control, and patient comfort. However, injectable hydrogels offer localized, minimally invasive treatment and conform to irregular wound shapes. This study presents carboxymethyl cellulose (CMC)-based injectable hydrogels, prepared via Diels–Alder click chemistry using highly furan functionalized CMC (45%) and a bismaleimide crosslinker. The hydrogels showed a rapid gelation time (E. coli, supporting its potential for wound healing applications.
Open AccessCMC-Based Injectable Hydrogels Crosslinked by Diels–Alder Chemistry for Wound Healing Applications
Chronic wounds disrupt natural healing and tissue regeneration, posing a major challenge in healthcare. Conventional wound care often lacks effective drug delivery, tissue integration, infection control, and patient comfort. However, injectable hydrogels offer localized, minimally invasive treatment and conform to irregular wound shapes. This study presents carboxymethyl cellulose (CMC)-based injectable hydrogels, prepared via Diels–Alder click chemistry using highly furan functionalized CMC (45%) and a bismaleimide crosslinker. The hydrogels showed a rapid gelation time (E. coli, supporting its potential for wound healing applications.
- 1 May 2025
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 172 (5) , 056509
Au3+-Assisted Bilirubin Oxidation and Electrochemical Investigation of Biliverdin on Poly(4-aminobenzoic acid)-Modified Screen-Printed Carbon Electrode
Free-unconjugated bilirubin (BR) is a crucial biomarker of liver function and its related disorders. Electrochemical BR detection suffers due to insolubility and its electrode fouling nature. This study demonstrates a new approach to the electrochemical investigation of biliverdin (BV), obtained from Au3+-assisted BR oxidation. The BR oxidation reaction was analyzed using UV–vis spectroscopy, demonstrating Au3+ as a suitable oxidant for complete BR oxidation within 3 min with a molar ratio of 1.67. Cyclic voltammetry and amperometric techniques were used to investigate the BV on poly (aminobenzoic acid) (PABA) modified screen-printed carbon electrodes (SPE). The fabricated SPE/PABA electrode was developed by potential-dynamic technique and characterized using physicochemical, and electrochemical methods. BV was electrochemically oxidized at 0.32 V in a buffer with pH 8.5. The SPE/PABA shows selective BV oxidation, reduced fouling, and enables a broad range of BV detection. The sensor shows a high sensitivity and linear range of 0.115 μA μM−1 cm−2 and 5 to 440 μM, respectively, with a limit of detection of 0.9 μM. Additionally, the sensor exhibited good reproducibility and high selectivity in the presence of potential interfering biomolecules. The analysis of human serum spiked samples shows promising results, suggesting potential applications in the diagnosis of bilirubin-related disorders.
- 1 May 2025
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 172 (5) , 056509
Au3+-Assisted Bilirubin Oxidation and Electrochemical Investigation of Biliverdin on Poly(4-aminobenzoic acid)-Modified Screen-Printed Carbon Electrode
Free-unconjugated bilirubin (BR) is a crucial biomarker of liver function and its related disorders. Electrochemical BR detection suffers due to insolubility and its electrode fouling nature. This study demonstrates a new approach to the electrochemical investigation of biliverdin (BV), obtained from Au3+-assisted BR oxidation. The BR oxidation reaction was analyzed using UV–vis spectroscopy, demonstrating Au3+ as a suitable oxidant for complete BR oxidation within 3 min with a molar ratio of 1.67. Cyclic voltammetry and amperometric techniques were used to investigate the BV on poly (aminobenzoic acid) (PABA) modified screen-printed carbon electrodes (SPE). The fabricated SPE/PABA electrode was developed by potential-dynamic technique and characterized using physicochemical, and electrochemical methods. BV was electrochemically oxidized at 0.32 V in a buffer with pH 8.5. The SPE/PABA shows selective BV oxidation, reduced fouling, and enables a broad range of BV detection. The sensor shows a high sensitivity and linear range of 0.115 μA μM−1 cm−2 and 5 to 440 μM, respectively, with a limit of detection of 0.9 μM. Additionally, the sensor exhibited good reproducibility and high selectivity in the presence of potential interfering biomolecules. The analysis of human serum spiked samples shows promising results, suggesting potential applications in the diagnosis of bilirubin-related disorders.
- 4 March 2025
- Published by American Chemical Society (ACS) in ACS Sustainable Chemistry & Engineering
- Vol. 13 (10) , 3867-3876
Stacked Spring-Based Nonelectric Fuel Delivery System for the Operation of Microfluidic Fuel Cells
- 4 March 2025
- Published by American Chemical Society (ACS) in ACS Sustainable Chemistry & Engineering
- Vol. 13 (10) , 3867-3876
Stacked Spring-Based Nonelectric Fuel Delivery System for the Operation of Microfluidic Fuel Cells
- 2 November 2024
- Published by Elsevier in Microchemical Journal
- Vol. 207
Innovative fluorescent ratiometric probe from Oolong tea dreg for highly sensitive bilirubin detection
- 2 November 2024
- Published by Elsevier in Microchemical Journal
- Vol. 207
Innovative fluorescent ratiometric probe from Oolong tea dreg for highly sensitive bilirubin detection
- 29 August 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1329, 343174
A novel low-cost and simple fabrication technique for a paper-based analytical device using super glue
- 29 August 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1329, 343174
A novel low-cost and simple fabrication technique for a paper-based analytical device using super glue