M. E. Bugriy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
M. E. Bugriy has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Sergey P. Mironov
Myasnikov Institute of Clinical Cardiology, National Medical Research Center for Cardiology
2 shared publications - Vladimir B. Sergienko
Myasnikov Institute of Clinical Cardiology, National Medical Research Center for Cardiology
2 shared publications - Elena I. Vasilenko
Sechenov First Moscow State Medical University
1 shared publication - Mariya A. Karalkina
Federal Center of Brain Research and Neurotechnologies
1 shared publication
Latest Publications
- 19 May 2026
- Published by Luchevaya Diagnostika in Journal of radiology and nuclear medicine
- Vol. 107 (1)
Focal Artifacts and Extraorgan Findings in Pulmonary Perfusion Scintigraphy
Objective : to clarify and systematize the causes of focal and non-organ artifacts capable of acting as diagnostic pitfalls in lung perfusion scintigraphy using 99mTc macroaggregated albumin (MAA), as well as their semiotics, principles, and methods for differentiating from pathological changes. Material and methods. The outcomes of lung perfusion scintigraphy were analyzed in 1,025 patients who underwent examinations to rule out pulmonary embolism (PE) or thromboembolic factors contributing to diagnosed pulmonary hypertension. The procedure was carried out in a multiplanar mode using twodetector single-photon emission computed tomography (SPECT) scanners while the patient was lying supine, 4–5 minutes after intravenous injection of a radiopharmaceutical (RPh) with an activity level of 111–148 MBq. Lung images were captured in six projections, including anterior, posterior, and four oblique planes. If required, additional screening was performed in combined SPECT/CT mode. The term “artifact” was used to describe isolated perfusion defects that simulate PE, as well as extrapulmonary findings resembling signs of a right-to-left shunt. Results . Artefact scintigraphic findings corresponding to the above criteria were found in 634 (61.8%) patients. Focal changes (n=618) were classified into “cold” and “hot” based on their scintigraphic presentation. Single “cold” lesions (n=611) were most commonly due to the shielding effect of altered anatomical structures (heart – 493, pulmonary artery trunk – 72, pleural effusion and elevated diaphragm – 41), as well as implanted pacemakers (n=5). “Hot spot” (n=7) obscured thromboembolic perfusion defects because of their high specific radioactivity. The main reason for this artifact is blood ingress into a syringe with 99mTc-MAA during intravenous administration of RPh. Extrapulmonary signs of right-to-left shunt were observed in 14 patients with congenital heart defects and were characterized by concurrent visualization of the kidneys and other organs in the systemic circulation (spleen, liver, thyroid gland). The reason for artefactual intestinal imaging (n=2) was residual radioactivity following prior myocardial perfusion scintigraphy with 99mTc methoxyisobutyl-isonitrile. Conclusion. Examining the reasons behind the occurrence of focal and extra-organ artifact findings in lung perfusion scintigraphy, as well as associated diagnostic and interpretive pitfalls, will enable the development of an appropriate quality control strategy to reduce the likelihood of false-positive interpretations of PE and systemic pulmonary shunts.
- 19 May 2026
- Published by Luchevaya Diagnostika in Journal of radiology and nuclear medicine
- Vol. 107 (1)
Focal Artifacts and Extraorgan Findings in Pulmonary Perfusion Scintigraphy
Objective : to clarify and systematize the causes of focal and non-organ artifacts capable of acting as diagnostic pitfalls in lung perfusion scintigraphy using 99mTc macroaggregated albumin (MAA), as well as their semiotics, principles, and methods for differentiating from pathological changes. Material and methods. The outcomes of lung perfusion scintigraphy were analyzed in 1,025 patients who underwent examinations to rule out pulmonary embolism (PE) or thromboembolic factors contributing to diagnosed pulmonary hypertension. The procedure was carried out in a multiplanar mode using twodetector single-photon emission computed tomography (SPECT) scanners while the patient was lying supine, 4–5 minutes after intravenous injection of a radiopharmaceutical (RPh) with an activity level of 111–148 MBq. Lung images were captured in six projections, including anterior, posterior, and four oblique planes. If required, additional screening was performed in combined SPECT/CT mode. The term “artifact” was used to describe isolated perfusion defects that simulate PE, as well as extrapulmonary findings resembling signs of a right-to-left shunt. Results . Artefact scintigraphic findings corresponding to the above criteria were found in 634 (61.8%) patients. Focal changes (n=618) were classified into “cold” and “hot” based on their scintigraphic presentation. Single “cold” lesions (n=611) were most commonly due to the shielding effect of altered anatomical structures (heart – 493, pulmonary artery trunk – 72, pleural effusion and elevated diaphragm – 41), as well as implanted pacemakers (n=5). “Hot spot” (n=7) obscured thromboembolic perfusion defects because of their high specific radioactivity. The main reason for this artifact is blood ingress into a syringe with 99mTc-MAA during intravenous administration of RPh. Extrapulmonary signs of right-to-left shunt were observed in 14 patients with congenital heart defects and were characterized by concurrent visualization of the kidneys and other organs in the systemic circulation (spleen, liver, thyroid gland). The reason for artefactual intestinal imaging (n=2) was residual radioactivity following prior myocardial perfusion scintigraphy with 99mTc methoxyisobutyl-isonitrile. Conclusion. Examining the reasons behind the occurrence of focal and extra-organ artifact findings in lung perfusion scintigraphy, as well as associated diagnostic and interpretive pitfalls, will enable the development of an appropriate quality control strategy to reduce the likelihood of false-positive interpretations of PE and systemic pulmonary shunts.
- Open Access
- 10 March 2021
- Published by Luchevaya Diagnostika in Journal of radiology and nuclear medicine
- Vol. 102 (1) , 18-27-27
Focal Artefacts in Skeletal Scitigraphy
Objective: to clarify and systematize the causes that can induce focal artefacts in skeletal scintigraphy with 99mTc-pyrophosphate (PyP), their semiotics, principles and methods of differentiation from bone pathology.Material and methods. Results of skeletal scintigraphy from 1568 patients were analyzed. Scanning in “whole body” mode started in 3 hours after 740 MBq of radiotracer activity intravenous administration, and performed in anterior and posterior projections in continuous table motion mode at rate of 12 cm per minute. Single photon emission computed tomography/computed tomography was additionally performed when necessary.Results. Focal artifacts were detected in 40 patients (2.55%) and were divided into “cold” and “hot” according to the nature of the bone system changes they simulated. “Cold” spots (n = 29) were the result of the shielding effect of metal accessories (n = 10), implants, endoprostheses (n = 18), and barium suspension residues in the large intestine (n = 1). “Hot” spots (n = 11) mimicking metastatic lesion of bone structures were the results of the projection effect of extraosseous uptake of 99mTc-PyP (n = 9) or urinary contamination (n = 2). “Hot” spots in the projection of the upper pole of the kidney (n = 5) could be the result of both calicostasis (n = 3) and injury of the adjacent rib (n = 2). The high uptake of 99mTc-PyP in thyroid nodule (n = 3) simulated a “hot” spot in the lateral part of the cervical vertebra. Abnormal accumulation of 99m Tc-PyP in the nipple-areola areas of the breast was projected onto the posterior segments of the ribs. Urinary contamination imitated focal pathology of the pelvic bones. To differentiate the focal pathology of the ribs and calicostases, the patients were examined in the standing position. The “mask in” program was used to clarify the localization and projection correspondence of “hot” foci.Conclusion. Analysis of focal artefacts formation causes in skeletal scintigraphy contributes to an adequate assessment of the data obtained, allows to choose the necessary method for their diagnosis and to avoid false results of osteoscintigraphy.
- 10 March 2021
- Published by Luchevaya Diagnostika in Journal of radiology and nuclear medicine
- Vol. 102 (1) , 18-27-27
Open AccessFocal Artefacts in Skeletal Scitigraphy
Objective: to clarify and systematize the causes that can induce focal artefacts in skeletal scintigraphy with 99mTc-pyrophosphate (PyP), their semiotics, principles and methods of differentiation from bone pathology.Material and methods. Results of skeletal scintigraphy from 1568 patients were analyzed. Scanning in “whole body” mode started in 3 hours after 740 MBq of radiotracer activity intravenous administration, and performed in anterior and posterior projections in continuous table motion mode at rate of 12 cm per minute. Single photon emission computed tomography/computed tomography was additionally performed when necessary.Results. Focal artifacts were detected in 40 patients (2.55%) and were divided into “cold” and “hot” according to the nature of the bone system changes they simulated. “Cold” spots (n = 29) were the result of the shielding effect of metal accessories (n = 10), implants, endoprostheses (n = 18), and barium suspension residues in the large intestine (n = 1). “Hot” spots (n = 11) mimicking metastatic lesion of bone structures were the results of the projection effect of extraosseous uptake of 99mTc-PyP (n = 9) or urinary contamination (n = 2). “Hot” spots in the projection of the upper pole of the kidney (n = 5) could be the result of both calicostasis (n = 3) and injury of the adjacent rib (n = 2). The high uptake of 99mTc-PyP in thyroid nodule (n = 3) simulated a “hot” spot in the lateral part of the cervical vertebra. Abnormal accumulation of 99m Tc-PyP in the nipple-areola areas of the breast was projected onto the posterior segments of the ribs. Urinary contamination imitated focal pathology of the pelvic bones. To differentiate the focal pathology of the ribs and calicostases, the patients were examined in the standing position. The “mask in” program was used to clarify the localization and projection correspondence of “hot” foci.Conclusion. Analysis of focal artefacts formation causes in skeletal scintigraphy contributes to an adequate assessment of the data obtained, allows to choose the necessary method for their diagnosis and to avoid false results of osteoscintigraphy.