Research Subjects
Birgit Frotscher has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Annie Harroche
Hemophilia care centre, Hematology unit Hôpital Universitaire Necker enfants malades Paris France
1 shared publicationBrigitte Pan Petesch
Unité Hémostase Service hématologie CHU Brest Brest France
1 shared publication- Christine Biron-Andreani
Haemophilia Treatment Centre, University Hospital of Montpellier, Montpellier, France
1 shared publication Cédric Martin
CSL Behring Paris France
1 shared publicationDiane Bracquart
CSL Behring Paris France
1 shared publicationDominique Desprez
Centre de Traitement de l'Hémophilie CHU Strasbourg Strasbourg France
1 shared publication
Latest Publications
- Open Access
- 29 April 2022
- Published by Wiley in European Journal of Haematology
- Vol. 109 (1) , 109-117
Effectiveness of long‐term prophylaxis using pdFVIII/VWF concentrate in patients with inherited von Willebrand disease
Background: Patients with symptomatic von Willebrand disease (VWD) should be offered long‐term prophylaxis (LTP) to prevent recurrent bleedings. Our objective was to evaluate the effectiveness and safety of Voncento®, a plasma‐derived FVIII/VWF concentrate (ratio 1:2.4), administrated in LTP.Methods: We included patients from the OPALE study (May 2016 to April 2021), a French multicenter observational study following patients with inherited VWD, who received a Voncento® LTP during the study period.Results: Among the 130 OPALE‐study patients, 23 patients (12 women) received a LTP and were therefore included. The median (range) age was 16 (1–85) years; 16 patients were type 3, 1 was type 2A, 6 were type 2B. Before inclusion, 19 (83%) were under LTP and 4 (17%) received on‐demand (OD) treatment. The indications for initiating prophylaxis in the overall population were joint bleeding (43%), ear, nose, and throat (ENT) bleeding including epistaxis or oral bleeding (39%), and recurrent muscle hematoma (22%). The medians (ranges) dose of Voncento® per infusion, frequency, and weekly dose were 45 (33–109) IU/kg, 2 infusions per week, and 96 (44–222) IU/kg/week, respectively. The median (range) annualized bleeding rate (ABR) was 0.8, 0.7 (0–3.5), and 0 (0–2.3) for type 2A, 2B, 3 patients, respectively. There was no difference regarding to the dose, frequency of infusion, or in terms of ABR in 9/19 patients who replaced previous concentrates with Voncento®. During the study period, no adverse event was reported.Conclusion: These results suggest that Voncento® is effective to prevent recurrent bleedings in patients symptomatic VWD.
- 29 April 2022
- Published by Wiley in European Journal of Haematology
- Vol. 109 (1) , 109-117
Open AccessEffectiveness of long‐term prophylaxis using pdFVIII/VWF concentrate in patients with inherited von Willebrand disease
Background: Patients with symptomatic von Willebrand disease (VWD) should be offered long‐term prophylaxis (LTP) to prevent recurrent bleedings. Our objective was to evaluate the effectiveness and safety of Voncento®, a plasma‐derived FVIII/VWF concentrate (ratio 1:2.4), administrated in LTP.Methods: We included patients from the OPALE study (May 2016 to April 2021), a French multicenter observational study following patients with inherited VWD, who received a Voncento® LTP during the study period.Results: Among the 130 OPALE‐study patients, 23 patients (12 women) received a LTP and were therefore included. The median (range) age was 16 (1–85) years; 16 patients were type 3, 1 was type 2A, 6 were type 2B. Before inclusion, 19 (83%) were under LTP and 4 (17%) received on‐demand (OD) treatment. The indications for initiating prophylaxis in the overall population were joint bleeding (43%), ear, nose, and throat (ENT) bleeding including epistaxis or oral bleeding (39%), and recurrent muscle hematoma (22%). The medians (ranges) dose of Voncento® per infusion, frequency, and weekly dose were 45 (33–109) IU/kg, 2 infusions per week, and 96 (44–222) IU/kg/week, respectively. The median (range) annualized bleeding rate (ABR) was 0.8, 0.7 (0–3.5), and 0 (0–2.3) for type 2A, 2B, 3 patients, respectively. There was no difference regarding to the dose, frequency of infusion, or in terms of ABR in 9/19 patients who replaced previous concentrates with Voncento®. During the study period, no adverse event was reported.Conclusion: These results suggest that Voncento® is effective to prevent recurrent bleedings in patients symptomatic VWD.
- Open Access
- 28 February 2021
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 5 (3) , ytaa447
Outbreak of SARS-CoV-2: challenge for diagnosis and medical management in patients with left ventricular assist device: a case series
Background: The outbreak of coronavirus disease 2019 (COVID-19) exposes vulnerable patients to high risk of mortality. Patients with left ventricular assist device (LVAD) usually have symptoms such as cough, fever, and shortness of breath because of their cardiac condition and comorbidity, therefore these related symptoms challenge the correct diagnosis in time within the COVID-19 pandemic. Case summary: We report two case studies of patients with LVAD in whom COVID-19 related symptoms were overlapped by their cardiac status and comorbidities. In the first case, the patient was admitted for suspicion of COVID-19 due to cough and shortness of breath for 1 month. The blood test evocated a high index of suspicion of COVID-19. The nasopharyngeal test for COVID-19 performed on admission and at Day 2 was inconclusive for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), but the test obtained on Day 3 of admission was positive, whereas computed tomography confirmed the diagnosis of COVID-19. This patient developed acute respiratory distress syndrome (ARDS) and nasal epistaxis within 48 h during hospitalization. The ARDS was treated by non-invasive ventilation and probabilistic antibiotics for 3 days and resulted significant improvement. The nasal epistaxis due to international normalized ratio increase was treated by nasal packing and vitamin K antagonist was switched to parenteral heparin infusion. The patient was kept hospitalized for 1 month for further supportive treatment. In the second case, the patient was admitted for recurrent anaemia due to melaena, the patient was tested for COVID-19 because of new-onset symptoms of cough and rhinorrhoea. The first nasopharyngeal test was positive, and sudden increase of anticoagulation status was noted in the setting of gastrointestinal bleeding. The anticoagulation status was controlled by parenteral heparin infusion, and the melaena was disappeared at Day 3. The moderate dyspnoea of the patient was quickly improved with nasal oxygen delivery for 4 days. The patient was discharged at Day 5. Discussion: COVID-19 specific symptoms are challenging to distinguish in patients with LVADs, although radiological evidence can be beneficial in the COVID-19 diagnosis. We also observed the need for precise anticoagulation control to avoid bleeding or thrombotic events in these patients.
- 28 February 2021
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 5 (3) , ytaa447
Open AccessOutbreak of SARS-CoV-2: challenge for diagnosis and medical management in patients with left ventricular assist device: a case series
Background: The outbreak of coronavirus disease 2019 (COVID-19) exposes vulnerable patients to high risk of mortality. Patients with left ventricular assist device (LVAD) usually have symptoms such as cough, fever, and shortness of breath because of their cardiac condition and comorbidity, therefore these related symptoms challenge the correct diagnosis in time within the COVID-19 pandemic. Case summary: We report two case studies of patients with LVAD in whom COVID-19 related symptoms were overlapped by their cardiac status and comorbidities. In the first case, the patient was admitted for suspicion of COVID-19 due to cough and shortness of breath for 1 month. The blood test evocated a high index of suspicion of COVID-19. The nasopharyngeal test for COVID-19 performed on admission and at Day 2 was inconclusive for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), but the test obtained on Day 3 of admission was positive, whereas computed tomography confirmed the diagnosis of COVID-19. This patient developed acute respiratory distress syndrome (ARDS) and nasal epistaxis within 48 h during hospitalization. The ARDS was treated by non-invasive ventilation and probabilistic antibiotics for 3 days and resulted significant improvement. The nasal epistaxis due to international normalized ratio increase was treated by nasal packing and vitamin K antagonist was switched to parenteral heparin infusion. The patient was kept hospitalized for 1 month for further supportive treatment. In the second case, the patient was admitted for recurrent anaemia due to melaena, the patient was tested for COVID-19 because of new-onset symptoms of cough and rhinorrhoea. The first nasopharyngeal test was positive, and sudden increase of anticoagulation status was noted in the setting of gastrointestinal bleeding. The anticoagulation status was controlled by parenteral heparin infusion, and the melaena was disappeared at Day 3. The moderate dyspnoea of the patient was quickly improved with nasal oxygen delivery for 4 days. The patient was discharged at Day 5. Discussion: COVID-19 specific symptoms are challenging to distinguish in patients with LVADs, although radiological evidence can be beneficial in the COVID-19 diagnosis. We also observed the need for precise anticoagulation control to avoid bleeding or thrombotic events in these patients.
- 28 April 2015
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 37 (5) , 613-619
Interference of blast cell fragments with automated platelet counting
Introduction: Automated haematology analysers may inaccurately determine platelet counts in several circumstances. Spuriously elevated automated platelet counts have been reported in some acute leukaemia (AL) cases because of fragmentation of circulating blast cells (pseudoplatelets). Haemorrhagic diathesis is a common manifestation of AL, which is often caused by severe thrombocytopenia. Therefore, overestimation of the actual platelet count in patients with AL can affect its clinical management. We aimed to detect the frequency of pseudoplatelets in patients with AL.Methods: Complete blood cell counts were performed on 86 AL patients with three automated analysers (ADVIA 2120, Coulter LH 750 and Sysmex XE‐2100D). Platelet counts were also performed by quantitative flow cytometry (QFC). The platelet counts of the automatic analysers were compared to the platelet counts by QFC. Blood smears were checked for the presence of pseudoplatelets.Results: The automated analysers overestimated the platelet count due to the presence of pseudoplatelets in patients with AL. Pseudoplatelets were observed in the blood smears of 11 patients (13%). Three of these patients were near the prophylactic platelet transfusion threshold.Conclusion: Spurious increases in automated platelet counts by blast cell fragments are little known but frequent artefacts that should be ruled out by careful examination of peripheral blood smears.
- 28 April 2015
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 37 (5) , 613-619
Interference of blast cell fragments with automated platelet counting
Introduction: Automated haematology analysers may inaccurately determine platelet counts in several circumstances. Spuriously elevated automated platelet counts have been reported in some acute leukaemia (AL) cases because of fragmentation of circulating blast cells (pseudoplatelets). Haemorrhagic diathesis is a common manifestation of AL, which is often caused by severe thrombocytopenia. Therefore, overestimation of the actual platelet count in patients with AL can affect its clinical management. We aimed to detect the frequency of pseudoplatelets in patients with AL.Methods: Complete blood cell counts were performed on 86 AL patients with three automated analysers (ADVIA 2120, Coulter LH 750 and Sysmex XE‐2100D). Platelet counts were also performed by quantitative flow cytometry (QFC). The platelet counts of the automatic analysers were compared to the platelet counts by QFC. Blood smears were checked for the presence of pseudoplatelets.Results: The automated analysers overestimated the platelet count due to the presence of pseudoplatelets in patients with AL. Pseudoplatelets were observed in the blood smears of 11 patients (13%). Three of these patients were near the prophylactic platelet transfusion threshold.Conclusion: Spurious increases in automated platelet counts by blast cell fragments are little known but frequent artefacts that should be ruled out by careful examination of peripheral blood smears.