Panagiota Anna Chousou
Panagiota Anna Chousou has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Liam Ring
Department of Cardiology, West Suffolk Hospital , Hardwick Lane, Bury St Edmunds, Bury Saint Edmunds IP33 2QZ
2 shared publicationsRahul Chattopadhyay
Norwich Medical School, University of East Anglia , Norwich NR4 7TJ , UK
2 shared publications- Rahul Chattopadhyay
University of East Anglia Norwich Research Park Department of Cardiac Medicine, Norwich Medical School Norwich, Norfolk, NR4 7TJ
2 shared publications - Vassilios S. Vassiliou
Norwich Medical School, University of East Anglia, Norwich NR4 7TJ, UK
2 shared publications Allan Clark
Norwich Medical School, University of East Anglia, Norwich NR4 7TJ, UK
1 shared publicationAris Perperoglou
School of Mathematics, Statistics and Astrophysics, University of Newcastle , Newcastle , UK
1 shared publication
Latest Publications
- Open Access
- 1 January 2026
- Published by Oxford University Press (OUP) in European Heart Journal - Imaging Methods and Practice
- Vol. 4 (1)
The predictive value of left atrioventricular coupling index for ILR-detected atrial fibrillation following an embolic stroke of undetermined source in patients with sinus rhythm
The prediction of atrial fibrillation in high-risk populations is an important research area of modern atrial fibrillation care. One such population is the embolic stroke of undetermined source population, where appropriate anticoagulation might help reduce the annual stroke recurrence risk by 5%. In this study, individuals were categorized according to their tertile of left atrioventricular coupling index, a composite echocardiographic parameter that reflects both left atrial and ventricular size. Its association with the detection of an implantable loop recorder and subclinical atrial fibrillation was investigated. A retrospective single-centre cohort study was performed. A total of 296 embolic stroke of undetermined source patients, referred for an implantable loop recorder, who also underwent echocardiography, were screened. Of these, 230 cases had echocardiograms of sufficient quality to measure the left atrioventricular coupling index. Patients were categorized according to their left atrioventricular coupling index tertile, with tertile 1 being less than 16.97, tertile 2 being 16.97–23.9, and tertile 3 being greater than 23.9. Patients in the third left atrioventricular coupling tertile were more likely to develop atrial fibrillation of any duration, with a 1.9-fold increased univariable hazard ratio, although this association was not significant in longer duration of atrial fibrillation episode. This effect was no longer significant with stepwise multivariable analysis, suggesting that age was primarily mediating the effect seen in this study. Left atrioventricular coupling index was not an independent predictor of future implantable loop recorder-detected atrial fibrillation after adjustment for age in this cohort.
- 1 January 2026
- Published by Oxford University Press (OUP) in European Heart Journal - Imaging Methods and Practice
- Vol. 4 (1)
Open AccessThe predictive value of left atrioventricular coupling index for ILR-detected atrial fibrillation following an embolic stroke of undetermined source in patients with sinus rhythm
The prediction of atrial fibrillation in high-risk populations is an important research area of modern atrial fibrillation care. One such population is the embolic stroke of undetermined source population, where appropriate anticoagulation might help reduce the annual stroke recurrence risk by 5%. In this study, individuals were categorized according to their tertile of left atrioventricular coupling index, a composite echocardiographic parameter that reflects both left atrial and ventricular size. Its association with the detection of an implantable loop recorder and subclinical atrial fibrillation was investigated. A retrospective single-centre cohort study was performed. A total of 296 embolic stroke of undetermined source patients, referred for an implantable loop recorder, who also underwent echocardiography, were screened. Of these, 230 cases had echocardiograms of sufficient quality to measure the left atrioventricular coupling index. Patients were categorized according to their left atrioventricular coupling index tertile, with tertile 1 being less than 16.97, tertile 2 being 16.97–23.9, and tertile 3 being greater than 23.9. Patients in the third left atrioventricular coupling tertile were more likely to develop atrial fibrillation of any duration, with a 1.9-fold increased univariable hazard ratio, although this association was not significant in longer duration of atrial fibrillation episode. This effect was no longer significant with stepwise multivariable analysis, suggesting that age was primarily mediating the effect seen in this study. Left atrioventricular coupling index was not an independent predictor of future implantable loop recorder-detected atrial fibrillation after adjustment for age in this cohort.
- Open Access
- 11 July 2023
- Published by Oxford University Press (OUP) in European Journal of Preventive Cardiology
- Vol. 30 (18) , 1965-1974
Atrial fibrillation in embolic stroke of undetermined source: role of advanced imaging of left atrial function
Aims: Atrial fibrillation (AF) is detected in over 30% of patients following an embolic stroke of undetermined source (ESUS) when monitored with an implantable loop recorder (ILR). Identifying AF in ESUS survivors has significant therapeutic implications, and AF risk is essential to guide screening with long-term monitoring. The present study aimed to establish the role of left atrial (LA) function in subsequent AF identification and develop a risk model for AF in ESUS. Methods and results: We conducted a single-centre retrospective case–control study including all patients with ESUS referred to our institution for ILR implantation from December 2009 to September 2019. We recorded clinical variables at baseline and analysed transthoracic echocardiograms in sinus rhythm. Univariate and multivariable analyses were performed to inform variables associated with AF. Lasso regression analysis was used to develop a risk prediction model for AF. The risk model was internally validated using bootstrapping. Three hundred and twenty-three patients with ESUS underwent ILR implantation. In the ESUS population, 293 had a stroke, whereas 30 had suffered a transient ischaemic attack as adjudicated by a senior stroke physician. Atrial fibrillation of any duration was detected in 47.1%. The mean follow-up was 710 days. Following lasso regression with backwards elimination, we combined increasing lateral PA (the time interval from the beginning of the P wave on the surface electrocardiogram to the beginning of the A′ wave on pulsed wave tissue Doppler of the lateral mitral annulus) [odds ratio (OR) 1.011], increasing Age (OR 1.035), higher Diastolic blood pressure (OR 1.027), and abnormal LA reservoir Strain (OR 0.973) into a new PADS score. The probability of identifying AF can be estimated using the formula. Model discrimination was good [area under the curve (AUC) 0.72]. The PADS score was internally validated using bootstrapping with 1000 samples of 150 patients showing consistent results with an AUC of 0.73. Conclusion: The novel PADS score can identify the risk of AF on prolonged monitoring with ILR following ESUS and should be considered a dedicated risk stratification tool for decision-making regarding the screening strategy for AF in stroke.
- 11 July 2023
- Published by Oxford University Press (OUP) in European Journal of Preventive Cardiology
- Vol. 30 (18) , 1965-1974
Open AccessAtrial fibrillation in embolic stroke of undetermined source: role of advanced imaging of left atrial function
Aims: Atrial fibrillation (AF) is detected in over 30% of patients following an embolic stroke of undetermined source (ESUS) when monitored with an implantable loop recorder (ILR). Identifying AF in ESUS survivors has significant therapeutic implications, and AF risk is essential to guide screening with long-term monitoring. The present study aimed to establish the role of left atrial (LA) function in subsequent AF identification and develop a risk model for AF in ESUS. Methods and results: We conducted a single-centre retrospective case–control study including all patients with ESUS referred to our institution for ILR implantation from December 2009 to September 2019. We recorded clinical variables at baseline and analysed transthoracic echocardiograms in sinus rhythm. Univariate and multivariable analyses were performed to inform variables associated with AF. Lasso regression analysis was used to develop a risk prediction model for AF. The risk model was internally validated using bootstrapping. Three hundred and twenty-three patients with ESUS underwent ILR implantation. In the ESUS population, 293 had a stroke, whereas 30 had suffered a transient ischaemic attack as adjudicated by a senior stroke physician. Atrial fibrillation of any duration was detected in 47.1%. The mean follow-up was 710 days. Following lasso regression with backwards elimination, we combined increasing lateral PA (the time interval from the beginning of the P wave on the surface electrocardiogram to the beginning of the A′ wave on pulsed wave tissue Doppler of the lateral mitral annulus) [odds ratio (OR) 1.011], increasing Age (OR 1.035), higher Diastolic blood pressure (OR 1.027), and abnormal LA reservoir Strain (OR 0.973) into a new PADS score. The probability of identifying AF can be estimated using the formula. Model discrimination was good [area under the curve (AUC) 0.72]. The PADS score was internally validated using bootstrapping with 1000 samples of 150 patients showing consistent results with an AUC of 0.73. Conclusion: The novel PADS score can identify the risk of AF on prolonged monitoring with ILR following ESUS and should be considered a dedicated risk stratification tool for decision-making regarding the screening strategy for AF in stroke.
- Open Access
- 1 December 2021
- Published by Oxford University Press (OUP) in European Journal of Preventive Cardiology
- Vol. 29 (6) , e227-e229
Sodium glucose co-transporter 2 inhibitors in heart failure with preserved ejection fraction: a systematic review and meta-analysis
Whilst heart failure with preserved ejection fraction (HFpEF) is increasingly studied, the search for a single pharmacotherapeutic agent that will improve hard endpoints like hospitalization and mortality still continues. 1 Given the various subphenotypes of HFpEF, 2 this makes it difficult for a single agent to be universally beneficial. The recent publication of EMPEROR-PRESEVED 3 was an instrumental time for an updated meta-analysis focused on sodium glucose co-transporter 2 inhibitors (SGLT2i) use in HFpEF.
- 1 December 2021
- Published by Oxford University Press (OUP) in European Journal of Preventive Cardiology
- Vol. 29 (6) , e227-e229
Open AccessSodium glucose co-transporter 2 inhibitors in heart failure with preserved ejection fraction: a systematic review and meta-analysis
Whilst heart failure with preserved ejection fraction (HFpEF) is increasingly studied, the search for a single pharmacotherapeutic agent that will improve hard endpoints like hospitalization and mortality still continues. 1 Given the various subphenotypes of HFpEF, 2 this makes it difficult for a single agent to be universally beneficial. The recent publication of EMPEROR-PRESEVED 3 was an instrumental time for an updated meta-analysis focused on sodium glucose co-transporter 2 inhibitors (SGLT2i) use in HFpEF.
- Open Access
- 9 March 2021
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 5 (3) , ytab063
Transfemoral cardiac resynchronization in a multi-comorbid patient
An 89-year-old female with severely impaired left ventricular function (ejection fraction biplane 27%) due to coronary artery disease, diabetes, and end-stage renal failure on haemodialysis, experienced repeated hospitalization due to heart failure decompensation. Electrocardiogram ( Supplementary Figure 1 ) demonstrated sinus rhythm with broad left bundle branch block (QRS duration 158 ms). Biventricular pacing was considered, but conventional approach via upper limb veins was unsuitable as she was on haemodialysis via a combination of left-sided fistula and right-sided tunnelled line. She was initially managed conservatively, as it was felt her comorbidities and vascular access concerns meant exposing her to the risks of complex device insertion was not in the patient’s best interest.
- 9 March 2021
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 5 (3) , ytab063
Open AccessTransfemoral cardiac resynchronization in a multi-comorbid patient
An 89-year-old female with severely impaired left ventricular function (ejection fraction biplane 27%) due to coronary artery disease, diabetes, and end-stage renal failure on haemodialysis, experienced repeated hospitalization due to heart failure decompensation. Electrocardiogram ( Supplementary Figure 1 ) demonstrated sinus rhythm with broad left bundle branch block (QRS duration 158 ms). Biventricular pacing was considered, but conventional approach via upper limb veins was unsuitable as she was on haemodialysis via a combination of left-sided fistula and right-sided tunnelled line. She was initially managed conservatively, as it was felt her comorbidities and vascular access concerns meant exposing her to the risks of complex device insertion was not in the patient’s best interest.