YCYongqiang Cheng

Yongqiang Cheng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yongqiang Cheng has a total of 8 co-authors. Here are the top co-authors by number of shared publications:

  • Hailian Jia

    Key Laboratory of Medicine Chemistry and Molecular Diagnosis, Ministry of Education, College of Chemistry and Environment Science, Hebei University, Baoding, P. R. China

    2 shared publications
  • Liyong Wang

    Key Laboratory of Medicine Chemistry and Molecular Diagnosis, Ministry of Education, College of Chemistry and Environment Science, Hebei University, Baoding, China

    2 shared publications
  • Zhengping Li

    Key Laboratory of Medicine Chemistry and Molecular Diagnosis, Ministry of Education, College of Chemistry and Environment Science, Hebei University, Baoding, P. R. China

    2 shared publications
  • Hui Wang

    Beijing Key Laboratory for Bioengineering and Sensing Technology, School of Chemistry and Biological Engineering, University of Science and Technology Beijing, 30 Xueyuan Road, Haidian District, Beijing, 100083, China

    1 shared publication
  • Jingjing Zhao

    Key Laboratory of Medicine Chemistry and Molecular Diagnosis, Ministry of Education, College of Chemistry and Environment Science, Hebei University, Baoding, P. R. China

    1 shared publication
  • Qing Du

    Key Laboratory of Medicine Chemistry and Molecular Diagnosis, Ministry of Education, College of Chemistry and Environment Science, Hebei University, Baoding 071002, China

    1 shared publication

Latest Publications

  • Ligase chain reaction coupled with rolling circle amplification for high sensitivity detection of single nucleotide polymorphisms

    by Yongqiang Cheng, Jingjing Zhao, Hailian Jia, Zheng Yuan, Zhengping Li

    We present a highly sensitive and homogeneous assay for the detection of single nucleotide polymorphisms (SNPs) by ligase chain reaction (LCR) coupled with rolling circle amplification (RCA). The LCR probes include one pair of probes and a padlock probe (PLP). In the LCR, one pair of probes composed of X and Y, perfectly hybridize with the upper strand of the target DNA after thermal denaturation. They are then ligated by the thermostable ligase to form the ligation product of XY. At the same time, the PLP hybridizes with the lower strand of the target DNA and are ligated to form the circular PLP (cPLP). After repeated cycles of denaturation, annealing, and ligation, the target DNA is amplified exponentially to generate a large number of XY and cPLPs. Subsequently, RCA is triggered by the cPLP as a template and XY as a primer, producing large numbers of long strand DNA products, which are detected by binding with the fluorescent dye, SYBR Green I, in a homogeneous manner. This method is simple, and avoids the need for detection of the LCR products with labeled probes and complex separation steps. The assay is sensitive and specific enough to detect a 1 fM target DNA molecule. It is possible to accurately determine the allele frequency as low as 1.0%. The LCR coupled with RCA assay extends the application of the LCR and RCA, and provides a new strategy for detecting SNPs as well as nucleic acid analysis, immunoassay, and molecular diagnosis.


  • A homogeneous fluorescence sensing platform with water-soluble carbon nanoparticles for detection of microRNA and nuclease activity

    by Liyong Wang, Yongqiang Cheng, Hui Wang, Zhengping Li

    Based on the high efficiency of fluorescence quenching and the different affinities of water-soluble carbon nanoparticles (CNPs) towards single-stranded DNA (ssDNA) and double-stranded DNA/RNA hybrid, a novel, rapid and cost-effective assay for detection of microRNA and nuclease activity was developed. The fluorescein-labeled ssDNA probe (FAM-P) could be adsorbed on the surface of CNPs through π–π stacking interaction giving rise to fluorescence quenching. By introduction of microRNA complementary to the DNA probe, the double-stranded DNA/miRNA hybrid could be formed and released from the surface of CNPs resulting in the fluorescence recovery. Thus, microRNA was successfully detected in homogenous fashion without any amplification or enzyme-involving reactions. Moreover, we demonstrated that the nuclease activities of RNase H and DNase I could also be sensitively monitored by using CNPs based on the fluorescence changing of the DNA probe. So, the CNPs provide an excellent homogeneous sensing platform for studying molecular diagnosis and therapeutics.


  • Fluorescently Cationic Conjugated Polymer as an Indicator of Ligase Chain Reaction for Sensitive and Homogeneous Detection of Single Nucleotide Polymorphism

    by Yongqiang Cheng, Qing Du, Liyong Wang, Hailian Jia, Zhengping Li

    Ligase chain reaction (LCR) offers a simple and robust alternative platform for nucleic acid amplification, but its application has been limited because the LCR products are mostly detected by gel electrophoresis separation or heterogeneous analysis. In this paper, we report a novel homogeneous LCR assay by using cationic conjugated polymers (CCPs) as an indicator for detection of single-nucleotide polymorphism (SNP). For LCR, we design two pairs of unique target-complement probes. Each pair of probes contains two adjacent probes, in which one probe is designed with phosphorothioate modification at its 3′-end, and the other probe is labeled with fluorescein at its 5′-end. After the LCR, the two adjacent probes are ligated to form one DNA strand with a fluorescein label at its 5′-end and phosphorothioate modification at its 3′-end, which is resistant to the exonuclease I and exonuclease III degradation. When the CCP is added, because of the strong electrostatic interactions between CCP and DNA, effective fluorescence resonance energy transfer (FRET) from the CCP to the fluorescein-labeled DNA can be observed. In contrast, the unligated fluorescein-labeled probes are degraded to the mononucleotides by exonuclease I and exonuclease III. Introduction of CCP leads to inefficient FRET results because much weaker electrostatic interactions between the fluorescein-labeled mononucleotides and CCP keep the fluorescein far away from CCP. Accordingly, homogeneous LCR for SNP detection is performed successfully. The method is sensitive and specific enough to detect 1 fM (600 zmol) DNA molecules. It is possible to quantify SNP and accurately determine the allele frequency as low as 1.0%. This proposed assay strategy extends the application of LCR and provides a new platform for homogeneous detection of SNP.