Seon-Chil Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Seon-Chil Kim has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Chang-Gyu Kim
Gimcheon University
1 shared publication - Hae-Kag Lee
Soonchunhyang University
1 shared publication - Jae-Hwan Cho
Ansan University
1 shared publication - Ji Hyun Yu
R&D Institute, Sae-An Enertech Corp, Daejeon 34016, Republic of Korea
1 shared publication Jun-Sik Son
Korea Textile Development Institute, Daegu, Korea
1 shared publicationKwang-Hwan Kim
Kon Yang University
1 shared publication
Latest Publications
- Open Access
- 3 September 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-12
Development and performance evaluation of medical radiation-reducing creams using eco-friendly radiation-shielding composites
To ensure the safety of medical personnel in healthcare organizations, radiation-shielding materials like protective clothing are used to protect against low-dose radiation, such as scattered rays. The extremities, particularly the hands, are the most exposed to radiation. New materials that can be directly coated onto the skin would be more cost-effective, efficient, and convenient than gloves. We developed protective creams using eco-friendly shielding materials, including barium sulfate, bismuth oxide, and ytterbium oxide, to avoid harmful effects of heavy metals like lead, and tested their skin-protective effects. Particularly, the radiation-shielding effect of ytterbium oxide was compared with that of the other materials. As shielding material dispersion and layer thickness greatly affect the efficacy of radiation-shielding creams, we assessed dispersion in terms of the weight percentage (wt%). The effective radiation energy was reduced by 20% with a 1.0-mm increase in cream thickness. Ytterbium oxide had a higher radiation-shielding rate than the other two materials. A 28% difference in protective effect was observed with varying wt%, and the 45 wt% cream at 63.4 keV radiation achieved a 61.3% reduction rate. Higher content led to a more stable incident energy-reducing effect. In conclusion, ytterbium oxide shows potential as a radiation-shielding material for creams.
- 3 September 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-12
Open AccessDevelopment and performance evaluation of medical radiation-reducing creams using eco-friendly radiation-shielding composites
To ensure the safety of medical personnel in healthcare organizations, radiation-shielding materials like protective clothing are used to protect against low-dose radiation, such as scattered rays. The extremities, particularly the hands, are the most exposed to radiation. New materials that can be directly coated onto the skin would be more cost-effective, efficient, and convenient than gloves. We developed protective creams using eco-friendly shielding materials, including barium sulfate, bismuth oxide, and ytterbium oxide, to avoid harmful effects of heavy metals like lead, and tested their skin-protective effects. Particularly, the radiation-shielding effect of ytterbium oxide was compared with that of the other materials. As shielding material dispersion and layer thickness greatly affect the efficacy of radiation-shielding creams, we assessed dispersion in terms of the weight percentage (wt%). The effective radiation energy was reduced by 20% with a 1.0-mm increase in cream thickness. Ytterbium oxide had a higher radiation-shielding rate than the other two materials. A 28% difference in protective effect was observed with varying wt%, and the 45 wt% cream at 63.4 keV radiation achieved a 61.3% reduction rate. Higher content led to a more stable incident energy-reducing effect. In conclusion, ytterbium oxide shows potential as a radiation-shielding material for creams.
- Open Access
- 17 November 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-11
Manufacturing and performance evaluation of medical radiation shielding fiber with plasma thermal spray coating technology
Lead, which has been used for radiation shielding in medicine, is currently sought to be replaced by an eco-friendly shielding material. Therefore, it should be replaced with shielding materials possessing excellent processability and radiation shielding performance similar to that of lead. In this study, a new process technology was developed focusing on the processability of tungsten, a representative eco-friendly shielding material. It is difficult to reproduce the shielding performance when using the method of coating nonwoven fabrics with a liquid using tungsten powder on a polymer material, which is adopted to ensure the flexibility of the shielding fabric. To address this, tungsten powder was sprayed on the fabric using a plasma thermal spray coating process and coated to a thickness of 0.2 mm to evaluate the shielding performance. Compared to standard lead with a thickness of 0.2 mm, the shielding efficiency differed by approximately 15%. Since the developed process can maintain the amount of injection in an area, it is possible to ensure the reproducibility of the shielding performance and automated process for mass production. This approach is economically feasible as it does not entail the mixing of polymer materials; hence, it can be used for preparing radiation shielding clothing for medical institutions.
- 17 November 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-11
Open AccessManufacturing and performance evaluation of medical radiation shielding fiber with plasma thermal spray coating technology
Lead, which has been used for radiation shielding in medicine, is currently sought to be replaced by an eco-friendly shielding material. Therefore, it should be replaced with shielding materials possessing excellent processability and radiation shielding performance similar to that of lead. In this study, a new process technology was developed focusing on the processability of tungsten, a representative eco-friendly shielding material. It is difficult to reproduce the shielding performance when using the method of coating nonwoven fabrics with a liquid using tungsten powder on a polymer material, which is adopted to ensure the flexibility of the shielding fabric. To address this, tungsten powder was sprayed on the fabric using a plasma thermal spray coating process and coated to a thickness of 0.2 mm to evaluate the shielding performance. Compared to standard lead with a thickness of 0.2 mm, the shielding efficiency differed by approximately 15%. Since the developed process can maintain the amount of injection in an area, it is possible to ensure the reproducibility of the shielding performance and automated process for mass production. This approach is economically feasible as it does not entail the mixing of polymer materials; hence, it can be used for preparing radiation shielding clothing for medical institutions.
- 9 February 2017
- Published by Springer Nature in Cluster Computing
- Vol. 21 (1) , 1109-1116
Development of radiation shield providing medical support for radioactive disaster in computer awareness analysis convergence-based
- 9 February 2017
- Published by Springer Nature in Cluster Computing
- Vol. 21 (1) , 1109-1116
Development of radiation shield providing medical support for radioactive disaster in computer awareness analysis convergence-based
- 4 May 2012
- Published by Springer Nature in Applied Magnetic Resonance
- Vol. 42 (4) , 531-544
The Usefulness of Diffusion-Weighted Imaging in MRI Test for Breast Cancer
- 4 May 2012
- Published by Springer Nature in Applied Magnetic Resonance
- Vol. 42 (4) , 531-544
The Usefulness of Diffusion-Weighted Imaging in MRI Test for Breast Cancer