Ze'EV Shpilman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ze'EV Shpilman has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Alon Hoffman
Schulich Faculty of Chemistry, Technion—Israel Institute of Technology, Haifa 3200003, Israel
2 shared publications R. Kalish
Solid State Institute , Physics Department, Technion, Haifa 32000, Israel
2 shared publications- Reed Hollinger
Colorado State University
2 shared publications Sh. Michaelson
Schulich Faculty of Chemistry , Technion, Haifa 32000, Israel
2 shared publications- Alex Wilhelm
Colorado School of Mines
1 shared publication B. Afeyan
Polymath Research, Inc. 3 , Pleasanton, California 94588, USA
1 shared publication
Latest Publications
- 11 December 2024
- Published by IOP Publishing in Journal of Optics
- Vol. 27 (1) , 015401
Enhanced proton acceleration using spiral-phase plasma mirrors
We present a method for generating intense vortex laser beams using spiral-phase plasma mirrors. These single-use micro-metric formations imprint a set amount of orbital angular momentum (OAM) to an arbitrary high power focusing beam. Using these beams, we irradiated ultrathin foils and measured the emission of ions from their back side. Utilizing a PW class laser, 5 J@45fs@2w resulting in an Intensity of 2×1020 W cm − 2 at spot focus, we observed an increase in the energy and numbers of these ions, compared to shots taken with reflection off flat plasma mirrors. A 45% increase in the proton numbers and a 35% increase in cutoff energy was observed. This is a major advance since the area of interaction and intensity are reduced due to the planar shape of the generated OAM laser. We review the available data-sets on laser ion acceleration using vortex beams, and conclude with a comparison to our findings.
- 11 December 2024
- Published by IOP Publishing in Journal of Optics
- Vol. 27 (1) , 015401
Enhanced proton acceleration using spiral-phase plasma mirrors
We present a method for generating intense vortex laser beams using spiral-phase plasma mirrors. These single-use micro-metric formations imprint a set amount of orbital angular momentum (OAM) to an arbitrary high power focusing beam. Using these beams, we irradiated ultrathin foils and measured the emission of ions from their back side. Utilizing a PW class laser, 5 J@45fs@2w resulting in an Intensity of 2×1020 W cm − 2 at spot focus, we observed an increase in the energy and numbers of these ions, compared to shots taken with reflection off flat plasma mirrors. A 45% increase in the proton numbers and a 35% increase in cutoff energy was observed. This is a major advance since the area of interaction and intensity are reduced due to the planar shape of the generated OAM laser. We review the available data-sets on laser ion acceleration using vortex beams, and conclude with a comparison to our findings.
- Open Access
- 3 April 2024
- Published by Springer Nature in Research Square
Ponderomotive snowplow electron acceleration with high energy tilted ultrafast laser pulses
The application high intensity ultrafast lasers to compact plasma-based electron accelerators has recently been an extremely active area of research. Here, for the first time, we show experimentally and theoretically that carefully sculpting an intense ultrafast pulse in the spatio-temporal domain allows ponderomotive pressure to be used for direct acceleration of electron bunches from rest to relativistic energies. With subluminal group velocity and above-threshold intensity, a laser pulse can capture and accelerate electrons, pushing on them like a snowplow. Acceleration of electrons from rest requires a substantial reduction of group velocity. In this demonstration experiment, we achieve a group velocity of ∼0.6c in a tilted pulse by focusing the output of a novel asymmetric pulse compressor we developed for the petawatt-class ALEPH system at Colorado State University. This direct laser-electron approach opens a route towards exploiting optical spatio-temporal control techniques to sculpt electron beams with desired properties such as narrow energy and angular distributions. The tilted-pulse snowplow technique can be scaled from small-scale to facility-scale amplifiers to produce short electron bunches in the 10 keV−10 MeV range for applications including ultrafast electron diffraction and efficient injection into laser wakefield accelerators for acceleration beyond the GeV level.
- 3 April 2024
- Published by Springer Nature in Research Square
Open AccessPonderomotive snowplow electron acceleration with high energy tilted ultrafast laser pulses
The application high intensity ultrafast lasers to compact plasma-based electron accelerators has recently been an extremely active area of research. Here, for the first time, we show experimentally and theoretically that carefully sculpting an intense ultrafast pulse in the spatio-temporal domain allows ponderomotive pressure to be used for direct acceleration of electron bunches from rest to relativistic energies. With subluminal group velocity and above-threshold intensity, a laser pulse can capture and accelerate electrons, pushing on them like a snowplow. Acceleration of electrons from rest requires a substantial reduction of group velocity. In this demonstration experiment, we achieve a group velocity of ∼0.6c in a tilted pulse by focusing the output of a novel asymmetric pulse compressor we developed for the petawatt-class ALEPH system at Colorado State University. This direct laser-electron approach opens a route towards exploiting optical spatio-temporal control techniques to sculpt electron beams with desired properties such as narrow energy and angular distributions. The tilted-pulse snowplow technique can be scaled from small-scale to facility-scale amplifiers to produce short electron bunches in the 10 keV−10 MeV range for applications including ultrafast electron diffraction and efficient injection into laser wakefield accelerators for acceleration beyond the GeV level.
- Open Access
- 1 May 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (5)
Variable magnetic field electron spectrometer to measure hot electrons in the range of 50–460 keV
Resonance absorption (RA) occurs when a p-polarized electromagnetic wave, obliquely incident on an inhomogeneous plasma, tunnels past its turning point and resonantly excites an electron plasma wave (EPW) at the critical density. This phenomenon is important, for instance, in the direct drive approach to inertial fusion energy and is a particular example of a wider phenomenon in plasma physics known as mode conversion, which is crucial for heating magnetic fusion devices, such as tokamaks, via RF heating. Direct measurement of these RA-generated EPW accelerated hot electrons, with energy in the range of a few tens to a few hundreds of keV, is a challenging task due to the relatively low deflecting magnetic fields needed. The solution described here is a magnetic electron spectrometer (MES) with a continually changing magnetic field, lower at the entrance of the MES and gradually increasing toward the end, that enables the measurement of a wide spectral range of electrons with energies between 50 and 460 keV. Electron spectra taken in a LaserNetUS RA experiment were acquired from plasmas generated by irradiating polymer targets with the combination of an ∼300 ps pulse followed by a series of ten high intensity 50–200 fs duration laser pulses from the ALEPH laser at Colorado State University. The high intensity beam is designed as spike trains of uneven duration and delay pulses in order to modify the RA phenomenon.
- 1 May 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (5)
Open AccessVariable magnetic field electron spectrometer to measure hot electrons in the range of 50–460 keV
Resonance absorption (RA) occurs when a p-polarized electromagnetic wave, obliquely incident on an inhomogeneous plasma, tunnels past its turning point and resonantly excites an electron plasma wave (EPW) at the critical density. This phenomenon is important, for instance, in the direct drive approach to inertial fusion energy and is a particular example of a wider phenomenon in plasma physics known as mode conversion, which is crucial for heating magnetic fusion devices, such as tokamaks, via RF heating. Direct measurement of these RA-generated EPW accelerated hot electrons, with energy in the range of a few tens to a few hundreds of keV, is a challenging task due to the relatively low deflecting magnetic fields needed. The solution described here is a magnetic electron spectrometer (MES) with a continually changing magnetic field, lower at the entrance of the MES and gradually increasing toward the end, that enables the measurement of a wide spectral range of electrons with energies between 50 and 460 keV. Electron spectra taken in a LaserNetUS RA experiment were acquired from plasmas generated by irradiating polymer targets with the combination of an ∼300 ps pulse followed by a series of ten high intensity 50–200 fs duration laser pulses from the ALEPH laser at Colorado State University. The high intensity beam is designed as spike trains of uneven duration and delay pulses in order to modify the RA phenomenon.
- 1 March 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (3) , 033527
Time-dependent soft and hard x-ray measurements using streak and x-ray diode array diagnostic systems
High-temperature, high-density experiments require a simultaneous understanding of temporal and spectral regions. The spectral x-ray streak camera (SXSC) is a new high-temporal-resolution spectral x-ray diagnostic system that allows researchers to differentiate between soft and hard x-ray regions. The diagnostic offers three spectral channels with a wide spectral range, one direct channel that includes a filter and two indirect channels that include both mirrors and filters. The opto-mechanical design positions the filtered radiation at three different locations along the streak photo-cathode (PC) slit to provide time-dependent spectral channels with pico-second temporal resolution. A moderate spatial resolution (150–700 μm) is achieved using slits perpendicular to the PC slit, while the slit width is optimized according to the central channel wavelength (for each channel). The diagnostic system covers a spectral range of 30–500 eV for the mirror channels and >1300 eV for the direct channel. The temporal and spatial axes of the streak camera are calibrated with respect to a sequence of x-ray pulses. The SXSC diagnostic system is tested and analyzed using Marshak-wave emission from an SiO2 foam that was heated by a laser-beam irradiated halfraum. The SXSC results are compared to measurements from an x-ray diode array with similar spectral channels.
- 1 March 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (3) , 033527
Time-dependent soft and hard x-ray measurements using streak and x-ray diode array diagnostic systems
High-temperature, high-density experiments require a simultaneous understanding of temporal and spectral regions. The spectral x-ray streak camera (SXSC) is a new high-temporal-resolution spectral x-ray diagnostic system that allows researchers to differentiate between soft and hard x-ray regions. The diagnostic offers three spectral channels with a wide spectral range, one direct channel that includes a filter and two indirect channels that include both mirrors and filters. The opto-mechanical design positions the filtered radiation at three different locations along the streak photo-cathode (PC) slit to provide time-dependent spectral channels with pico-second temporal resolution. A moderate spatial resolution (150–700 μm) is achieved using slits perpendicular to the PC slit, while the slit width is optimized according to the central channel wavelength (for each channel). The diagnostic system covers a spectral range of 30–500 eV for the mirror channels and >1300 eV for the direct channel. The temporal and spatial axes of the streak camera are calibrated with respect to a sequence of x-ray pulses. The SXSC diagnostic system is tested and analyzed using Marshak-wave emission from an SiO2 foam that was heated by a laser-beam irradiated halfraum. The SXSC results are compared to measurements from an x-ray diode array with similar spectral channels.
- 18 December 2006
- Published by AIP Publishing in Applied Physics Letters
- Vol. 89 (25) , 252114
Enhanced electron field emission from preferentially oriented graphitic films
The electron field emission properties of nanographite films, whose basal planes display a degree of preferred orientation perpendicular to the surface, are reported. It was found that nanometric thick films which display a high degree of preferred orientation perpendicular to the substrate emit electrons at a high turn on field (TOF), while thicker films which display a much lower degree of preferred orientation emit electrons at a significantly lower TOF. It is suggested that the observed effect is mainly associated with the degree of basal planes orientation of the nanostructures and not just to their length.
- 18 December 2006
- Published by AIP Publishing in Applied Physics Letters
- Vol. 89 (25) , 252114
Enhanced electron field emission from preferentially oriented graphitic films
The electron field emission properties of nanographite films, whose basal planes display a degree of preferred orientation perpendicular to the surface, are reported. It was found that nanometric thick films which display a high degree of preferred orientation perpendicular to the substrate emit electrons at a high turn on field (TOF), while thicker films which display a much lower degree of preferred orientation emit electrons at a significantly lower TOF. It is suggested that the observed effect is mainly associated with the degree of basal planes orientation of the nanostructures and not just to their length.
- 1 April 2006
- Published by Elsevier in Diamond and Related Materials
- Vol. 15 (4-8) , 846-849
Field emission measurements from carbon films of a predominant nano-crystalline diamond character grown by energetic species
- 1 April 2006
- Published by Elsevier in Diamond and Related Materials
- Vol. 15 (4-8) , 846-849
Field emission measurements from carbon films of a predominant nano-crystalline diamond character grown by energetic species