Michael K. Jensen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Michael K. Jensen has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Yoav Peles
3 shared publicationsGregory J. Michna
Department of Mechanical Engineering, South Dakota State University, Brookings, SD 57007
2 shared publicationsSaptarshi Basu
Department of Mechanical, Aerospace and Nuclear Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180
2 shared publicationsSidy Ndao
Department of Mechanical, Aerospace and Nuclear Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180
2 shared publicationsA. P. Roday
Department of Mechanical, Aerospace and Nuclear Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180-3590
1 shared publication- Ali Koşar
Faculty of Engineering and Natural Sciences, Sabanci University, 34956 Tuzla, Istanbul, Turkey
1 shared publication
Latest Publications
- 3 February 2011
- Published by Wiley in Journal of Heat Transfer
- Vol. 133 (5) , 051503
Flow Boiling of R134a in Circular Microtubes—Part II: Study of Critical Heat Flux Condition
A detailed experimental study was carried out on the critical heat flux (CHF) condition for flow boiling of R134a in single circular microtubes. The test sections had inner diameters (ID) of 0.50 mm, 0.96 mm, and 1.60 mm. Experiments were conducted over a large range of mass flux, inlet subcooling, saturation pressure, and vapor quality. CHF occurred under saturated conditions at high qualities and increased with increasing mass fluxes, tube diameters, and inlet subcoolings. CHF generally, but not always, decreases with increasing saturation pressures and vapor qualities. The experimental data were mapped to the flow pattern maps developed by Hasan [2005, “Two-Phase Flow Regime Transitions in Microchannels: A Comparative Experimental Study,” Nanoscale Microscale Thermophys. Eng., 9, pp. 165–182] and Revellin and Thome [2007, “A New Type of Diabatic Flow Pattern Map for Boiling Heat Transfer in Microchannels,” J. Micromech. Microeng., 17, pp. 788–796]. Based on these maps, CHF mainly occurred in the annular flow regime in the larger tubes. The flow pattern for the 0.50 mm ID tube was not conclusively identified. Four correlations—the Bowring correlation, the Katto-Ohno correlation, the Thome correlation, and the Zhang correlation—were used to predict the experimental data. The correlations predicted the correct experimental trend, but the mean absolute error (MAE) was high (>15%) A new correlation was developed to fit the experimental data with a MAE of 10%.
- 3 February 2011
- Published by Wiley in Journal of Heat Transfer
- Vol. 133 (5) , 051503
Flow Boiling of R134a in Circular Microtubes—Part II: Study of Critical Heat Flux Condition
A detailed experimental study was carried out on the critical heat flux (CHF) condition for flow boiling of R134a in single circular microtubes. The test sections had inner diameters (ID) of 0.50 mm, 0.96 mm, and 1.60 mm. Experiments were conducted over a large range of mass flux, inlet subcooling, saturation pressure, and vapor quality. CHF occurred under saturated conditions at high qualities and increased with increasing mass fluxes, tube diameters, and inlet subcoolings. CHF generally, but not always, decreases with increasing saturation pressures and vapor qualities. The experimental data were mapped to the flow pattern maps developed by Hasan [2005, “Two-Phase Flow Regime Transitions in Microchannels: A Comparative Experimental Study,” Nanoscale Microscale Thermophys. Eng., 9, pp. 165–182] and Revellin and Thome [2007, “A New Type of Diabatic Flow Pattern Map for Boiling Heat Transfer in Microchannels,” J. Micromech. Microeng., 17, pp. 788–796]. Based on these maps, CHF mainly occurred in the annular flow regime in the larger tubes. The flow pattern for the 0.50 mm ID tube was not conclusively identified. Four correlations—the Bowring correlation, the Katto-Ohno correlation, the Thome correlation, and the Zhang correlation—were used to predict the experimental data. The correlations predicted the correct experimental trend, but the mean absolute error (MAE) was high (>15%) A new correlation was developed to fit the experimental data with a MAE of 10%.
- 3 February 2011
- Published by Wiley in Journal of Heat Transfer
- Vol. 133 (5) , 051502
Flow Boiling of R134a in Circular Microtubes—Part I: Study of Heat Transfer Characteristics
An experimental study of two-phase heat transfer coefficients was carried out using R134a in uniformly heated horizontal circular microtubes with diameters from 0.50 mm to 1.60 mm over a range of mass fluxes, heat fluxes, saturation pressures, and vapor qualities. Heat transfer coefficients increased with increasing heat flux and saturation pressure but were independent of mass flux. The effects of vapor quality on heat transfer coefficients were less pronounced and varied depending on the quality. The data were compared with seven flow boiling correlations. None of the correlations predicted the experimental data very well, although they generally predicted the correct trends within limits of experimental error. A correlation was developed, which predicted the heat transfer coefficients with a mean average error of 29%. 80% of the data points were within the ±30% error limit.
- 3 February 2011
- Published by Wiley in Journal of Heat Transfer
- Vol. 133 (5) , 051502
Flow Boiling of R134a in Circular Microtubes—Part I: Study of Heat Transfer Characteristics
An experimental study of two-phase heat transfer coefficients was carried out using R134a in uniformly heated horizontal circular microtubes with diameters from 0.50 mm to 1.60 mm over a range of mass fluxes, heat fluxes, saturation pressures, and vapor qualities. Heat transfer coefficients increased with increasing heat flux and saturation pressure but were independent of mass flux. The effects of vapor quality on heat transfer coefficients were less pronounced and varied depending on the quality. The data were compared with seven flow boiling correlations. None of the correlations predicted the experimental data very well, although they generally predicted the correct trends within limits of experimental error. A correlation was developed, which predicted the heat transfer coefficients with a mean average error of 29%. 80% of the data points were within the ±30% error limit.
- 13 September 2009
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 23 (9) , 2529-2547
A review of the critical heat flux condition in mini-and microchannels
- 13 September 2009
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 23 (9) , 2529-2547
A review of the critical heat flux condition in mini-and microchannels
- 1 January 2008
- Published by Wiley in Journal of Heat Transfer
- Vol. 130 (1) , 012901
The Critical Heat Flux Condition With Water in a Uniformly Heated Microtube
The critical heat flux (CHF) condition needs to be well understood for designing miniature devices involving two-phase flow. Experiments were performed to determine the CHF condition for a single stainless steel tube having an inside diameter of 0.427mm subjected to uniform heat flux boundary conditions. The effects of mass flux, pressure, and exit quality on the CHF were investigated. The experimental results show that the CHF increases with an increase in mass flux and exit pressure. For all exit pressures, the CHF decreased with an increase in quality in the subcooled region, but with a further increase in quality (near zero quality and above), the CHF was found to have an increasing trend with quality (up to about 25% quality). CHF values in this region were much higher than those in the subcooled region. This suggests that even at very low qualities, the void fraction becomes appreciable, which results in an increase in the average velocity, thereby increasing the CHF limit.
- 1 January 2008
- Published by Wiley in Journal of Heat Transfer
- Vol. 130 (1) , 012901
The Critical Heat Flux Condition With Water in a Uniformly Heated Microtube
The critical heat flux (CHF) condition needs to be well understood for designing miniature devices involving two-phase flow. Experiments were performed to determine the CHF condition for a single stainless steel tube having an inside diameter of 0.427mm subjected to uniform heat flux boundary conditions. The effects of mass flux, pressure, and exit quality on the CHF were investigated. The experimental results show that the CHF increases with an increase in mass flux and exit pressure. For all exit pressures, the CHF decreased with an increase in quality in the subcooled region, but with a further increase in quality (near zero quality and above), the CHF was found to have an increasing trend with quality (up to about 25% quality). CHF values in this region were much higher than those in the subcooled region. This suggests that even at very low qualities, the void fraction becomes appreciable, which results in an increase in the average velocity, thereby increasing the CHF limit.
- 25 February 2006
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 2 (5) , 387-397
Methods and preliminary results on enhanced boiling heat transfer in second generation microchannels
- 25 February 2006
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 2 (5) , 387-397
Methods and preliminary results on enhanced boiling heat transfer in second generation microchannels
- 20 May 2001
- Published by Wiley in Journal of Heat Transfer
- Vol. 123 (6) , 1035-1044
Geometry Effects on Turbulent Flow and Heat Transfer in Internally Finned Tubes
A parametric study has been performed on turbulent flow and heat transfer in internally finned tubes. For a rectangular fin profile, the effects of fin number N, fin width s, fin height H, and helix angle γ were numerically investigated for the conditions of N=10∼40,H=0.03∼0.1,s=0.05∼0.22,γ=10 deg∼40 deg, and Re=40,000. In addition, the performance of three fin profiles—rectangle, triangle, and round crest—with the same fin heights, width, and helix angles were compared for Reynolds numbers between 10,000 and 70,000. Rectangular and triangular fins behave similarly; for some geometric conditions the round crest fin has lower friction factors and Nusselt numbers (17 and 10 percent, respectively) than the rectangular fin. However, when the number of fins is large, the round crest fin can have larger friction factors (about 16 percent). Damping of turbulence energy in the interfin region is credited for the reversal of the typical trends.
- 20 May 2001
- Published by Wiley in Journal of Heat Transfer
- Vol. 123 (6) , 1035-1044
Geometry Effects on Turbulent Flow and Heat Transfer in Internally Finned Tubes
A parametric study has been performed on turbulent flow and heat transfer in internally finned tubes. For a rectangular fin profile, the effects of fin number N, fin width s, fin height H, and helix angle γ were numerically investigated for the conditions of N=10∼40,H=0.03∼0.1,s=0.05∼0.22,γ=10 deg∼40 deg, and Re=40,000. In addition, the performance of three fin profiles—rectangle, triangle, and round crest—with the same fin heights, width, and helix angles were compared for Reynolds numbers between 10,000 and 70,000. Rectangular and triangular fins behave similarly; for some geometric conditions the round crest fin has lower friction factors and Nusselt numbers (17 and 10 percent, respectively) than the rectangular fin. However, when the number of fins is large, the round crest fin can have larger friction factors (about 16 percent). Damping of turbulence energy in the interfin region is credited for the reversal of the typical trends.