Sisi Yang
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sisi Yang has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
Alexandre Bône
Guerbet Research, Villepinte, France
2 shared publicationsAntoine Feydy
Department of Radiology, Hôpital Cochin, APHP, 75014 Paris, France; Université Paris Cité, 75006 Paris, France; INSERM U1153, Clinical Epidemiology and Biostatistics, PRES Sorbonne Paris-Cité, 75004 Paris, France
2 shared publicationsJoan Alexis Glaunès
MAP5 (UMR 8145), Université Paris Cité, Paris, France
2 shared publications- A. Benaissa
From the Department of Neuroradiology (W.B., A.B., J.-L.A., S.B., L.S.-V., Q.A., P.I., S.Y., E.K.), Centre-Hospitalier-Universitaire Henri Mondor, Créteil, France
1 shared publication - Adrien Bordner
Sorbonne Médecine Université, 75013 Paris, France; Department of Radiology, Hôpital Cochin, APHP, 75014 Paris, France
1 shared publication Ahmed Mekki
Department of Radiology, Hôpital Raymond-Poincaré, Assistance Publique-Hôpitaux de Paris (AP-HP), Garches, France
1 shared publication
Latest Publications
- 18 August 2026
- Published by Springer Nature in La radiologia medica
- Vol. 131 (9) , 1613-1625
Prognostic value of body composition analysis in cancer patients treated with immunotherapy: a systematic evaluation of TotalSegmentator-based biomarkers
- 18 August 2026
- Published by Springer Nature in La radiologia medica
- Vol. 131 (9) , 1613-1625
Prognostic value of body composition analysis in cancer patients treated with immunotherapy: a systematic evaluation of TotalSegmentator-based biomarkers
- 5 February 2026
- Published by Springer Nature in European Radiology
- Vol. 36 (6) , 5043-5052
Auto-LSN: fully automated liver surface nodularity quantification in CT based on deep learning for the evaluation of advanced chronic liver disease
Objectives Liver surface nodularity (LSN) is a recognized non-invasive biomarker of cirrhosis. This study introduces auto-LSN, an artificial intelligence (AI)-based algorithm for fully automated LSN quantification, assesses its association with fibrosis stage and its non-inferiority in diagnostic performance for advanced chronic liver disease (ACLD) and cirrhosis compared to the FDA-approved, semi-automated liver boundary analysis (LBA) software. Materials and methods This retrospective, bicentric study included patients with chronic liver disease risk factors who underwent CT and liver biopsy between April 2014 and March 2020. Fibrosis stages were grouped into F3–F4 (ACLD) vs F0–F2, and F4 (cirrhosis) vs F0–F3 per the METAVIR. LSN was measured with auto-LSN and LBA. Their association with fibrosis grade and diagnostic accuracy for ACLD and cirrhosis were compared using a −0.05 non-inferiority margin. Mann–Whitney–Wilcoxon tests, Spearman correlation, and area under the receiver operating characteristic curve (AUC) were used. Results In 127 patients (68 ± 12 years; 97 men), auto-LSN demonstrated a positive correlation with fibrosis stage (ρ = 0.59; 95% CI [0.48, 0.68]), similar to LBA (ρ = 0.44; 95% CI [0.32, 0.55]), both p < 0.001, with differences within the non-inferiority margin ([0.03, 0.26]). Auto-LSN achieved AUCs of 0.79 (95% CI [0.70, 0.87]) for ACLD and 0.84 (95% CI [0.76, 0.91]) for cirrhosis, comparable to LBA’s AUCs of 0.73 (95% CI [0.64, 0.82]) and 0.74 (95% CI [0.66, 0.83]), respectively. All differences were within the non-inferiority margin. Conclusion Auto-LSN correlates positively with fibrosis stage and provides non-inferior diagnostic performance compared to LBA. Its full automation and accuracy support its potential for opportunistic screening and objective patient monitoring. Key Points Question LSN is a key radiological feature for non-invasive ACLD diagnosis. However, current LSN quantification software is only semi-automated, thus time-consuming. Findings The fully automated auto-LSN algorithm for LSN quantification achieved statistically non-inferior diagnostic performance compared to existing semi-automated software for the detection of ACLD and cirrhosis. Clinical relevance Auto-LSN, as a fully automated solution, offers a reliable alternative to existing semi-automated software, enabling mass opportunistic screening of the general population—by evaluating all CT scans performed for any indication—and supporting objective follow-up of at-risk patients. Graphical Abstract
- 5 February 2026
- Published by Springer Nature in European Radiology
- Vol. 36 (6) , 5043-5052
Auto-LSN: fully automated liver surface nodularity quantification in CT based on deep learning for the evaluation of advanced chronic liver disease
Objectives Liver surface nodularity (LSN) is a recognized non-invasive biomarker of cirrhosis. This study introduces auto-LSN, an artificial intelligence (AI)-based algorithm for fully automated LSN quantification, assesses its association with fibrosis stage and its non-inferiority in diagnostic performance for advanced chronic liver disease (ACLD) and cirrhosis compared to the FDA-approved, semi-automated liver boundary analysis (LBA) software. Materials and methods This retrospective, bicentric study included patients with chronic liver disease risk factors who underwent CT and liver biopsy between April 2014 and March 2020. Fibrosis stages were grouped into F3–F4 (ACLD) vs F0–F2, and F4 (cirrhosis) vs F0–F3 per the METAVIR. LSN was measured with auto-LSN and LBA. Their association with fibrosis grade and diagnostic accuracy for ACLD and cirrhosis were compared using a −0.05 non-inferiority margin. Mann–Whitney–Wilcoxon tests, Spearman correlation, and area under the receiver operating characteristic curve (AUC) were used. Results In 127 patients (68 ± 12 years; 97 men), auto-LSN demonstrated a positive correlation with fibrosis stage (ρ = 0.59; 95% CI [0.48, 0.68]), similar to LBA (ρ = 0.44; 95% CI [0.32, 0.55]), both p < 0.001, with differences within the non-inferiority margin ([0.03, 0.26]). Auto-LSN achieved AUCs of 0.79 (95% CI [0.70, 0.87]) for ACLD and 0.84 (95% CI [0.76, 0.91]) for cirrhosis, comparable to LBA’s AUCs of 0.73 (95% CI [0.64, 0.82]) and 0.74 (95% CI [0.66, 0.83]), respectively. All differences were within the non-inferiority margin. Conclusion Auto-LSN correlates positively with fibrosis stage and provides non-inferior diagnostic performance compared to LBA. Its full automation and accuracy support its potential for opportunistic screening and objective patient monitoring. Key Points Question LSN is a key radiological feature for non-invasive ACLD diagnosis. However, current LSN quantification software is only semi-automated, thus time-consuming. Findings The fully automated auto-LSN algorithm for LSN quantification achieved statistically non-inferior diagnostic performance compared to existing semi-automated software for the detection of ACLD and cirrhosis. Clinical relevance Auto-LSN, as a fully automated solution, offers a reliable alternative to existing semi-automated software, enabling mass opportunistic screening of the general population—by evaluating all CT scans performed for any indication—and supporting objective follow-up of at-risk patients. Graphical Abstract
- 15 May 2021
- Published by Springer Nature in European Radiology
- Vol. 31 (12) , 9380-9389
Can T2-weighted Dixon fat-only images replace T1-weighted images in degenerative disc disease with Modic changes on lumbar spine MRI?
Objectives To evaluate the diagnostic performance and interobserver agreement of a magnetic resonance imaging (MRI) protocol that only includes sagittal T2-weighted Dixon fat and water images as an alternative to a standard protocol that includes both sagittal T1-weighted sequence and T2-weighted Dixon water images as reference standard in lumbar degenerative disc disease with Modic changes. Methods From February 2017 to March 2019, 114 patients who underwent lumbar spine MRI for low back pain were included in this retrospective study. All MRI showed Modic changes at least at one vertebral level. Two radiologists read the standard protocol and 1 month later the alternative protocol. All MRI were assessed for Modic changes (types, location, extension) as well as structural changes (endplate defects, facet arthropathy, spinal stenosis, foraminal stenosis, Schmorl nodes, spondylolisthesis, disc bulges, and degeneration). Interobserver agreement was assessed, as well as diagnostic performance using the standard protocol as reference standard. Results Interobserver agreement was moderate to excellent (kappa ranging from 0.51 to 0.92). Diagnostic performance of the alternative protocol was good for detection of any Modic change (sensitivity = 100.00% [95% CI, 99.03–100.00]; specificity = 98.89% [95% CI, 98.02–99.44]), as well as for detection of each Modic subtype and structural variables (sensitivity respectively 100% and ranging from 88.43 to 99.75% ; specificity ranging respectively from 97.62 to 100% and 99.58 to 99.91% ). Conclusions Combined with T2-weighted Dixon water images, T2-weighted Dixon fat images provide good diagnostic performance compared to T1-weighted images in lumbar degenerative disc disease with Modic changes, and could therefore allow for a shortened protocol. Key Points • Combined with T2-weighted Dixon water images, T2-weighted Dixon fat images (in comparison to T1-weighted sequence) can provide good diagnostic performance in lumbar degenerative disc disease with Modic changes. • Interobserver agreement of the alternative protocol including sagittal T2-weighted Dixon fat and water images was substantial to excellent for every studied variable except for facet arthropathy. • A shortened MRI protocol including T2-weighted Dixon sequence without T1-weighted sequence could be proposed in this clinical setting.
- 15 May 2021
- Published by Springer Nature in European Radiology
- Vol. 31 (12) , 9380-9389
Can T2-weighted Dixon fat-only images replace T1-weighted images in degenerative disc disease with Modic changes on lumbar spine MRI?
Objectives To evaluate the diagnostic performance and interobserver agreement of a magnetic resonance imaging (MRI) protocol that only includes sagittal T2-weighted Dixon fat and water images as an alternative to a standard protocol that includes both sagittal T1-weighted sequence and T2-weighted Dixon water images as reference standard in lumbar degenerative disc disease with Modic changes. Methods From February 2017 to March 2019, 114 patients who underwent lumbar spine MRI for low back pain were included in this retrospective study. All MRI showed Modic changes at least at one vertebral level. Two radiologists read the standard protocol and 1 month later the alternative protocol. All MRI were assessed for Modic changes (types, location, extension) as well as structural changes (endplate defects, facet arthropathy, spinal stenosis, foraminal stenosis, Schmorl nodes, spondylolisthesis, disc bulges, and degeneration). Interobserver agreement was assessed, as well as diagnostic performance using the standard protocol as reference standard. Results Interobserver agreement was moderate to excellent (kappa ranging from 0.51 to 0.92). Diagnostic performance of the alternative protocol was good for detection of any Modic change (sensitivity = 100.00% [95% CI, 99.03–100.00]; specificity = 98.89% [95% CI, 98.02–99.44]), as well as for detection of each Modic subtype and structural variables (sensitivity respectively 100% and ranging from 88.43 to 99.75% ; specificity ranging respectively from 97.62 to 100% and 99.58 to 99.91% ). Conclusions Combined with T2-weighted Dixon water images, T2-weighted Dixon fat images provide good diagnostic performance compared to T1-weighted images in lumbar degenerative disc disease with Modic changes, and could therefore allow for a shortened protocol. Key Points • Combined with T2-weighted Dixon water images, T2-weighted Dixon fat images (in comparison to T1-weighted sequence) can provide good diagnostic performance in lumbar degenerative disc disease with Modic changes. • Interobserver agreement of the alternative protocol including sagittal T2-weighted Dixon fat and water images was substantial to excellent for every studied variable except for facet arthropathy. • A shortened MRI protocol including T2-weighted Dixon sequence without T1-weighted sequence could be proposed in this clinical setting.
- 11 March 2021
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 42 (6) , 1116-1122
Delayed Contrast-Enhanced MR Angiography for the Assessment of Internal Carotid Bulb Patency in the Context of Acute Ischemic Stroke: An Accuracy, Interrater, and Intrarater Agreement Study
BACKGROUND AND PURPOSE: CTA has shown limited accuracy and reliability in distinguishing tandem occlusions and pseudo-occlusions on initial acute stroke imaging. The utility of early and delayed contrast-enhanced MRA in this setting is unknown. We aimed to assess the accuracy and reliability of early and delayed contrast-enhanced MRA for carotid bulb patency in patients with acute ischemic stroke. MATERIALS AND METHODS: We retrospectively reviewed patients who had ICA occlusion and underwent thrombectomy with preprocedural early and delayed contrast-enhanced MRA in a single comprehensive stroke center. During 2 sessions, 10 raters independently assessed 32 cases with early contrast-enhanced MRA (with an additional delayed contrast-enhanced MRA sequence during the second reading session). Their judgments were compared with DSA as a reference standard. Accuracy and interrater agreement were measured. Five raters undertook a third reading session to assess intrarater agreement. RESULTS: Accuracy for the assessment of carotid bulb patency with early contrast-enhanced MRA was limited (69%; 95% CI, 59%–79%), with moderate interrater agreement (κ = 0.42; 95% CI, 0.27–0.55). The second reading with an additional delayed contrast-enhanced MRA sequence improved both accuracy (82%; 95% CI, 73%–91%; P < .001) (raters corrected 43%–77% of incorrect diagnoses with early contrast-enhanced MRA alone; mean = 59%) and interrater agreement (κ = 0.56; 95% CI, 0.41–0.73; P = .07). Intrarater agreement was almost perfect, substantial, and moderate for 3, 1, and 1 raters. CONCLUSIONS: Early contrast-enhanced MRA has limited accuracy and repeatability for the evaluation of carotid bulb patency in acute ischemic stroke. The additional delayed contrast-enhanced MRA sequence may improve accuracy and reliability.
- 11 March 2021
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 42 (6) , 1116-1122
Delayed Contrast-Enhanced MR Angiography for the Assessment of Internal Carotid Bulb Patency in the Context of Acute Ischemic Stroke: An Accuracy, Interrater, and Intrarater Agreement Study
BACKGROUND AND PURPOSE: CTA has shown limited accuracy and reliability in distinguishing tandem occlusions and pseudo-occlusions on initial acute stroke imaging. The utility of early and delayed contrast-enhanced MRA in this setting is unknown. We aimed to assess the accuracy and reliability of early and delayed contrast-enhanced MRA for carotid bulb patency in patients with acute ischemic stroke. MATERIALS AND METHODS: We retrospectively reviewed patients who had ICA occlusion and underwent thrombectomy with preprocedural early and delayed contrast-enhanced MRA in a single comprehensive stroke center. During 2 sessions, 10 raters independently assessed 32 cases with early contrast-enhanced MRA (with an additional delayed contrast-enhanced MRA sequence during the second reading session). Their judgments were compared with DSA as a reference standard. Accuracy and interrater agreement were measured. Five raters undertook a third reading session to assess intrarater agreement. RESULTS: Accuracy for the assessment of carotid bulb patency with early contrast-enhanced MRA was limited (69%; 95% CI, 59%–79%), with moderate interrater agreement (κ = 0.42; 95% CI, 0.27–0.55). The second reading with an additional delayed contrast-enhanced MRA sequence improved both accuracy (82%; 95% CI, 73%–91%; P < .001) (raters corrected 43%–77% of incorrect diagnoses with early contrast-enhanced MRA alone; mean = 59%) and interrater agreement (κ = 0.56; 95% CI, 0.41–0.73; P = .07). Intrarater agreement was almost perfect, substantial, and moderate for 3, 1, and 1 raters. CONCLUSIONS: Early contrast-enhanced MRA has limited accuracy and repeatability for the evaluation of carotid bulb patency in acute ischemic stroke. The additional delayed contrast-enhanced MRA sequence may improve accuracy and reliability.