XRXavier Rottenberg

Xavier Rottenberg

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Xavier Rottenberg has a total of 104 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparison of Bulk Piezoelectric and Opto-Mechanical Micromachined Detectors for Optoacoustic and Ultrasound Sensing

    by A. Prebeck, G. Keulemans, U. Stahl, H. Jans, X. Rottenberg, V. Ntziachristos

    Optical detection of sound, using optomechanical micromachined ultrasound sensors (OMUS), is a promising detection technology for optoacoustic (OptA) imaging because it achieves a small active detection area, in the few tens of micrometers size, without loss of sensitivity as a function of area size. It also has potential to be produced as array configurations at low cost. However, while OMUS sensitivity has been reported in terms of noise equivalent pressure density (NEPD), there has been no comparison to conventional piezoelectric transducers under identical conditions. We differentially compared a highly sensitive ring-resonator-based OMUS and a single element focused piezoelectric ultrasound transducer (FPUT), under the same experimental conditions. The comparison considered the detectors’ signal-to-noise ratio (SNR), impulse response, axial point-spread-function and their spatial sensitivity. Our results show that OMUS attained lower SNR to FPUT, when operating at the same working distance, but similar performance when placed close to the sample interrogated, for example, as it relates to OptA microscopy. Advantageously, OMUS uniquely offers the spatial behavior of a point-like acoustic detector which reduces the sensitivity to ultrasound interference effects occurring on the large detection area of FPUTs. We discuss the implications of the two detection approaches in the design of OptA systems.


  • Open Access

    Analysis of Collapse–Snapback Phenomena in Capacitive Micromachined Ultrasound Transducers

    by Chloé Halbach, Veronique Rochus, Jan Genoe, Xavier Rottenberg, David Cheyns, Paul Heremans

    The pull-in and pull-out voltages are important characteristics of Capacitive Micromachined Ultrasound Transducers (CMUTs), marking the transition between conventional and collapse operation regimes. These voltages are commonly determined using capacitance–voltage (C-V) sweeps. By modeling the operating conditions of an LCR meter in COMSOL Multiphysics®, we demonstrate that the measured capacitance comprises both static and dynamic capacitances, with the dynamic capacitance causing the appearance of a peak in the effective C-V curve. Furthermore, Laser Doppler Vibrometer (LDV) measurements and electromechanical simulations indicate the occurrence of collapse–snapback phenomena during the C-V sweeps. This study, through advanced simulations and experimental analyses, demonstrates that the transient membrane behavior significantly affects the apparent capacitance–voltage characteristics of electrostatically actuated Micro-Electromechanical Systems (MEMS).


  • Open Access

    Sensor-Enabled Safety Systems for Human–Robot Collaboration: A Review

    by Constantin Scholz, Hoang-Long Cao, Emil Imrith, Nima Roshandel, Hamed Firouzipouyaei, Aleksander Burkiewicz, Milan Amighi, Sebastien Menet, Dylan Warawout Sisavath, Antonio Paolillo, et al.

    Sensors are integrated into collaborative robot systems to ensure the safety of human workers by allowing them to perceive their environments, detect human presence, and adjust their actions accordingly. This PRISMA scoping review focuses on current sensor-enabled safety systems for human-robot collaboration in the manufacturing industry based on both scientific papers and patents. From the initial search of 6669 references, 281 underwent full-text review and segmentation based on sensor technology, installation location, and safety operating mode according to the ISO/TS 15066 standard. In the last decade, there has been a clear trend of increasing sensor-enabled safety systems. The dominant sensors used are infrared-structured light, capacitive, LiDAR, resistive, stereo/depth camera, RaDAR, and laser scanners. The primary safety operating mode identified was Speed and Separation Monitoring (SSM). Some systems integrate multiple sensor types, with the most common combinations being LiDAR with stereo cameras or LiDAR with capacitive sensors, and laser scanners with RaDAR. We suggest multi-sensor integration and standardized benchmarks for future development. This review is among the few that employ the PRISMA protocol to study sensor technologies and contribute to a more systematic understanding of the current state of the art in this area.


  • Sensitive Optomechanical Ultrasound Sensor in an LED-Based, Low Fluence Photoacoustic Imaging System

    by Cedric Pieters, Tom Verschooten, Grim Keulemans, Liesbet Lagae, Jon Øyvind Kjellman, Xavier Rottenberg, Hilde Jans

    Affordable and compact light sources, along with highly sensitive, broadband, low-noise sensors, are essential for enabling point-of-care photoacoustic imaging applications in resource-limited settings. Traditional systems use piezoelectric transducers, which often suffer from limited bandwidth and sensitivity, combined with solid-state lasers that are expensive and bulky. We present a potentially low-cost LED-based photoacoustic imaging system featuring a highly sensitive optomechanical ultrasound sensor operating near thermomechanical noise limits. Utilizing a 620 nm LED, our setup delivers microjoules of pulse energy with 100 ns pulse widths. We demonstrate its capability to resolve fine details through 2D scan tomography, with minimal averaging for an effective sample rate of 100 Hz. Future improvements, including the development of larger LED arrays, multiplexed sensors and on-chip integrated lasers, promise to enhance performance and further expand the technology's applicability


  • Open Access

    Unsupervised Domain Adaptation for Inter-Session Re-Calibration of Ultrasound-Based HMIs

    by Antonios Lykourinas, Xavier Rottenberg, Francky Catthoor, Athanassios Skodras

    Human–Machine Interfaces (HMIs) have gained popularity as they allow for an effortless and natural interaction between the user and the machine by processing information gathered from a single or multiple sensing modalities and transcribing user intentions to the desired actions. Their operability depends on frequent periodic re-calibration using newly acquired data due to their adaptation needs in dynamic environments, where test–time data continuously change in unforeseen ways, a cause that significantly contributes to their abandonment and remains unexplored by the Ultrasound-based (US-based) HMI community. In this work, we conduct a thorough investigation of Unsupervised Domain Adaptation (UDA) algorithms for the re-calibration of US-based HMIs during within-day sessions, which utilize unlabeled data for re-calibration. Our experimentation led us to the proposal of a CNN-based architecture for simultaneous wrist rotation angle and finger gesture prediction that achieves comparable performance with the state-of-the-art while featuring 87.92% less trainable parameters. According to our findings, DANN (a Domain-Adversarial training algorithm), with proper initialization, offers an average 24.99% classification accuracy performance enhancement when compared to no re-calibration setting. However, our results suggest that in cases where the experimental setup and the UDA configuration may differ, observed enhancements would be rather small or even unnoticeable.


  • Lumped Element Model for an Optomechanical Ultrasound Sensor

    by C. Pieters, R. Haouri, F.R. Lamberti, G. Keulemans, J. Kjellman, X. Rottenberg

    A lumped element model for an optomechanical ultrasound sensor is compared to thermomechanical noise measurements and a finite-element model. The lumped element model is accurate, easy-to-use, and fast with future potential for simulating large sensor arrays for on-chip multiplexing and photoacoustic imaging.

  • Photoacoustic imaging using an optomechanical ultrasound sensor for future applications in breast cancer imaging

    by Hilde Jans, Cedric Pieters, Deep Bera, Grim Keulemans, Roelof Jansen, Veronique Rochus, Jon Kjellman, Hasan Md. Mahmud-Ul-Hasan, Xavier Rottenberg

    Breast cancer is the most common cancer, and early detection is important to improve survival rates. For diagnosis, new imaging modality are required. Photoacoustic imaging (PAI) is arguably the most exciting 3D molecular imaging technique, since it provides functional information on the hemoglobin distribution in breast that can be used to identify malignant lesions. PAI is an absorption technique where optical pulses are used to generate sound waves. It combines both the advantages of the high contrast of optical imaging and the deep penetration of acoustic imaging. We have developed an extreme sensitivity optomechanical ultrasound sensor. This sensor enables broadband, high-resolution PAI and present great future promise in advancing breast cancer screening.

  • Rigorous analysis of the axial acoustic radiation force on a spherical object for single-beam acoustic tweezing applications

    by Bart P. Weekers, Xavier Rottenberg, Liesbet Lagae, Veronique Rochus

    Acoustic tweezers are increasingly utilized for the contactless manipulation of small particles. This paper provides a theoretical model demonstrating the acoustic manipulation capabilities of single-beam acoustic transducers. Analytical formulas are derived for the acoustic radiation force on an isotropic spherical object of arbitrary size, centered on a circular piston, simply supported and clamped radiator in an inviscid fluid. Using these results, the existence of a negative axial force pulling the object closer to the radiator is revealed and explored. These findings offer further insight into the feasibility of trapping objects in the near-field of a single-beam acoustic transducer. The calculations illustrate the trapping capabilities of the different emitters as a function of radiator size, particle size, and distance from the source and highlight the impact of radiator boundary conditions. Manipulation of a cell-like fluid sphere in water and an expanded polystyrene sphere in air are studied in more detail with results that are validated through finite element analysis. The developed theoretical model allows fast evaluation of acoustic radiation forces which could aid in the development of relatively simple and inexpensive contactless manipulation solutions.


  • Densely Integrated Phase Interrogators for Low-Complexity On-Chip Calibration of Optical Phased Arrays

    by Jon Oyvind Kjellman, Mathias Prost, Aleksandrs Marinins, Hemant Kumar Tyagi, Tangla David Kongnyuy, Sarvagya Dwivedi, Marcus S. Dahlem, Philippe Soussan, Xavier Rottenberg, Roelof Jansen

    Optical phase errors are inherent to practical waveguides and will degrade the beam quality of optical phased arrays. This paper demonstrates a scalable approach to on-chip phase calibration of optical phased arrays using a compact phase interrogator structure. This phase interrogator is designed for optical phased arrays with a 2.5μm pitch and demonstrated in a 64-channel optical phased array realized in a Si/SiN photonic stack. The optical phased array exhibits 38° of unambiguous beam steering range and a side lobe level of at most -9.8 dB after calibration. The calibration algorithm is model-based and does not rely on any iterative optimization algorithm. This enables calibration with linear scaling of both the computational complexity and the area of the calibration structures. By including wavelength dependent effects, the model allows for 2D beam steering without any need for re-calibration.


  • Top Cited Papers

    Sensitive, small, broadband and scalable optomechanical ultrasound sensor in silicon photonics

    by Wouter J. Westerveld, Mahmud- Ul- Hasan, Rami Shnaiderman, Vasilis Ntziachristos, Xavier Rottenberg, Simone Severi, Veronique Rochus