Flávio Cesar Bedatty Fernandes
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Flávio Cesar Bedatty Fernandes has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Paulo Roberto Bueno
São Paulo State University (UNESP)
10 shared publications Jason J. Davis
Department of Chemistry, University of Oxford, Oxford OX1 3QZ, UK
4 shared publications- Helena Redigolo Pezza
Instituto de Química, Universidade Estadual Paulista "Julio de Mesquita Filho", UNESP, R. Prof. Francisco Degni 55, P.O. Box 355, 14800-900 Araraquara, SP, Brazil
3 shared publications - Leonardo Pezza
Instituto de Química, Universidade Estadual Paulista "Julio de Mesquita Filho", UNESP, R. Prof. Francisco Degni 55, P.O. Box 355, 14800-900 Araraquara, SP, Brazil
3 shared publications Amol V. Patil
Department of Chemistry, University of Oxford , South Parks Road, Oxford, OX1 3QZ, United Kingdom
2 shared publications- Aline Santana Silva
Instituto de Química, Universidade Estadual Paulista (UNESP), P.O. Box 355, Araraquara, CEP 14801-970 SP, Brazil
1 shared publication
Latest Publications
- 1 July 2019
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 291, 493-501
A nanoscale redox-active composite as a low-fouling interface for capacitive assaying
- 1 July 2019
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 291, 493-501
A nanoscale redox-active composite as a low-fouling interface for capacitive assaying
- 16 May 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (12) , 7651-7658
Reagentless Detection of Low-Molecular-Weight Triamterene Using Self-Doped TiO2 Nanotubes
TiO2 nanotube electrodes were self-doped by electrochemical cathodic polarization, potentially converting Ti4+ into Ti3+, and thereby increasing both the normalized conductance and capacitance of the electrodes. One-hundred (from 19.2 ± 0.1 μF cm−2 to 1.9 ± 0.1 mF cm−2 for SD-TNT) and two-fold (from ∼6.2 to ∼14.4 mS cm–2) concomitant increases in capacitance and conductance, respectively, were achieved in self-doped TiO2 nanotubes; this was compared with the results for their undoped counterparts. The increases in the capacitance and conductance indicate that the Ti3+ states enhance the density of the electronic states; this is attributed to an existing relationship between the conductance and capacitance for nanoscale structures built on macroscopic electrodes. The ratio between the conductance and capacitance was used to detect and quantify, in a reagentless manner, the triamterene (TRT) diuretic by designing an appropriate doping level of TiO2 nanotubes. The sensitivity was improved when using immittance spectroscopy (Patil et al. Anal. Chem.2015, 87, 944–950; Bedatty Fernandes et al. Anal. Chem.2015, 87, 12137–12144) (2.4 × 106 % decade–1) compared to cyclic voltammetry (5.8 × 105 % decade–1). Furthermore, a higher linear range from 0.5 to 100 μmol L–1 (5.0 to 100 μmol L–1 for cyclic voltammetry measurements) and a lower limit-of-detection of approximately 0.2 μmol L–1 were achieved by using immittance function methodology (better than the 4.1 μmol L–1 obtained by using cyclic voltammetry).
- 16 May 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (12) , 7651-7658
Reagentless Detection of Low-Molecular-Weight Triamterene Using Self-Doped TiO2 Nanotubes
TiO2 nanotube electrodes were self-doped by electrochemical cathodic polarization, potentially converting Ti4+ into Ti3+, and thereby increasing both the normalized conductance and capacitance of the electrodes. One-hundred (from 19.2 ± 0.1 μF cm−2 to 1.9 ± 0.1 mF cm−2 for SD-TNT) and two-fold (from ∼6.2 to ∼14.4 mS cm–2) concomitant increases in capacitance and conductance, respectively, were achieved in self-doped TiO2 nanotubes; this was compared with the results for their undoped counterparts. The increases in the capacitance and conductance indicate that the Ti3+ states enhance the density of the electronic states; this is attributed to an existing relationship between the conductance and capacitance for nanoscale structures built on macroscopic electrodes. The ratio between the conductance and capacitance was used to detect and quantify, in a reagentless manner, the triamterene (TRT) diuretic by designing an appropriate doping level of TiO2 nanotubes. The sensitivity was improved when using immittance spectroscopy (Patil et al. Anal. Chem.2015, 87, 944–950; Bedatty Fernandes et al. Anal. Chem.2015, 87, 12137–12144) (2.4 × 106 % decade–1) compared to cyclic voltammetry (5.8 × 105 % decade–1). Furthermore, a higher linear range from 0.5 to 100 μmol L–1 (5.0 to 100 μmol L–1 for cyclic voltammetry measurements) and a lower limit-of-detection of approximately 0.2 μmol L–1 were achieved by using immittance function methodology (better than the 4.1 μmol L–1 obtained by using cyclic voltammetry).
- 1 December 2017
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 253, 1106-1112
Optimized electrochemical biosensor for human prostatic acid phosphatase
- 1 December 2017
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 253, 1106-1112
Optimized electrochemical biosensor for human prostatic acid phosphatase
- 18 September 2017
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 9 (40) , 15362-15370
Quantum capacitance as a reagentless molecular sensing element
The application of nanoscale capacitance as a transduction of molecular recognition relevant to molecular diagnostics is demonstrated, wherein the energy-related signal relates directly to the electron occupation of quantized states.
- 18 September 2017
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 9 (40) , 15362-15370
Quantum capacitance as a reagentless molecular sensing element
The application of nanoscale capacitance as a transduction of molecular recognition relevant to molecular diagnostics is demonstrated, wherein the energy-related signal relates directly to the electron occupation of quantized states.
- 6 February 2017
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 19 (9) , 6792-6806
Mesoscopic behaviour of multi-layered graphene: the meaning of supercapacitance revisited
The electronic density of states and its contribution to the capacitance of graphene compounds (oxidized and reduced) were investigated using an electrochemical impedance-derived capacitance spectroscopic approach. It is clearly demonstrated that graphene oxide, which is known to exhibit semiconductor electronic characteristics, has little influence on the magnitude of the measured capacitance. Moreover, when graphene oxide is electrochemically reduced to graphene, the capacitance increases dramatically by about three orders of magnitude (from microfaradays to millifaradays). This increased capacitive effect has been interpreted as being directly associated with the electrochemical non-faradaic (super- or ultracapacitive) characteristics of the interface (i.e. associated with its electroactive area, for instance). The results obtained and interpretation made in this work demonstrate that the magnitude of the measured capacitance is a consequence of an electrochemical capacitive phenomenon (mesoscopic in essence; thus, the associated capacitance is equivalently termed mesoscopic capacitance) that energetically contains, in series, both electrostatic (geometrical) and quantum effects, thus being essentially different from those exclusively related to the amount of existing interfacial sites for ions (i.e. beyond those associated with pure double-layer capacitive effects). Conceptually, it is proposed that the mesoscopic capacitance of reduced graphene can be explained mainly through quantum chemical effects, ultimately following first-principles quantum mechanics supported on density functional theory, wherein the density of states is central.
- 6 February 2017
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 19 (9) , 6792-6806
Mesoscopic behaviour of multi-layered graphene: the meaning of supercapacitance revisited
The electronic density of states and its contribution to the capacitance of graphene compounds (oxidized and reduced) were investigated using an electrochemical impedance-derived capacitance spectroscopic approach. It is clearly demonstrated that graphene oxide, which is known to exhibit semiconductor electronic characteristics, has little influence on the magnitude of the measured capacitance. Moreover, when graphene oxide is electrochemically reduced to graphene, the capacitance increases dramatically by about three orders of magnitude (from microfaradays to millifaradays). This increased capacitive effect has been interpreted as being directly associated with the electrochemical non-faradaic (super- or ultracapacitive) characteristics of the interface (i.e. associated with its electroactive area, for instance). The results obtained and interpretation made in this work demonstrate that the magnitude of the measured capacitance is a consequence of an electrochemical capacitive phenomenon (mesoscopic in essence; thus, the associated capacitance is equivalently termed mesoscopic capacitance) that energetically contains, in series, both electrostatic (geometrical) and quantum effects, thus being essentially different from those exclusively related to the amount of existing interfacial sites for ions (i.e. beyond those associated with pure double-layer capacitive effects). Conceptually, it is proposed that the mesoscopic capacitance of reduced graphene can be explained mainly through quantum chemical effects, ultimately following first-principles quantum mechanics supported on density functional theory, wherein the density of states is central.
- 3 December 2015
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 87 (24) , 12137-12144
Optimized Diagnostic Assays Based on Redox Tagged Bioreceptive Interfaces
Among the numerous label free electronic biomarker assay methodologies now available, impedance based electrochemical capacitance spectroscopy (ECS), based upon mapping the perturbations in interfacial charging of redox elements incorporated into a biologically receptive interface, has recently been shown to be a convenient and highly sensitive mode of transduction and one which, additionally, requires no predoping of analytical solution. We present, herein, a data acquisition and analysis methodology based on frequency resolved immittance function analysis. Ultimately, this enables both a maximization of assay sensitivity and a reduction in assay acquisition time by an order of magnitude.
- 3 December 2015
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 87 (24) , 12137-12144
Optimized Diagnostic Assays Based on Redox Tagged Bioreceptive Interfaces
Among the numerous label free electronic biomarker assay methodologies now available, impedance based electrochemical capacitance spectroscopy (ECS), based upon mapping the perturbations in interfacial charging of redox elements incorporated into a biologically receptive interface, has recently been shown to be a convenient and highly sensitive mode of transduction and one which, additionally, requires no predoping of analytical solution. We present, herein, a data acquisition and analysis methodology based on frequency resolved immittance function analysis. Ultimately, this enables both a maximization of assay sensitivity and a reduction in assay acquisition time by an order of magnitude.
- 1 January 2015
- Published by Elsevier in Food Chemistry
- Vol. 166, 309-315
Screening and determination of sulphonamide residues in bovine milk samples using a flow injection system
- 1 January 2015
- Published by Elsevier in Food Chemistry
- Vol. 166, 309-315
Screening and determination of sulphonamide residues in bovine milk samples using a flow injection system
- 9 December 2014
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 87 (2) , 944-950
Immittance Electroanalysis in Diagnostics
Impedance derived electroanalytical assays are inherently spectroscopic (frequency resolved) and potentially exceedingly sensitive indicators of interfacial change (such as target binding at an appropriate receptor). We introduce here the use of a portfolio of mathematically derived immittance functions and related components, capable, from the same raw data sets, of enabling increased assay sensitivity and markedly shorter assay times in comparison to traditional impedance analyses. The methodology, applied herein to faradaic (redox probe amplified) and non-faradaic assays, requires no equivalent circuit analysis or prior assumption of response. Its focus is to optimize analytical potency and to enable the user to select and apply the most frequency-optimized reporter of interfacial change and to, thereafter, run rapid (optimized) analyses at single frequencies.
- 9 December 2014
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 87 (2) , 944-950
Immittance Electroanalysis in Diagnostics
Impedance derived electroanalytical assays are inherently spectroscopic (frequency resolved) and potentially exceedingly sensitive indicators of interfacial change (such as target binding at an appropriate receptor). We introduce here the use of a portfolio of mathematically derived immittance functions and related components, capable, from the same raw data sets, of enabling increased assay sensitivity and markedly shorter assay times in comparison to traditional impedance analyses. The methodology, applied herein to faradaic (redox probe amplified) and non-faradaic assays, requires no equivalent circuit analysis or prior assumption of response. Its focus is to optimize analytical potency and to enable the user to select and apply the most frequency-optimized reporter of interfacial change and to, thereafter, run rapid (optimized) analyses at single frequencies.
- 3 February 2014
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 86 (5) , 2559-2564
Label-free Capacitive Diagnostics: Exploiting Local Redox Probe State Occupancy
An electrode surface confined redox group contributes to a substantial potential-dependent interfacial charging that can be sensitively probed and frequency-resolved by impedance-derived capacitance spectroscopy. In utilizing the sensitivity of this charging fingerprint to redox group environment, one can seek to generate derived sensory configurations. Exemplified here through the generation of mixed molecular films comprising ferrocene and antibody receptors to two clinically important targets, the label-free methodology is able to report on human prostatic acid phosphatase (PAP), a tumor marker, with a limit of detection of 11 pM and C-reactive protein with a limit of detection of 28 pM. Both assays exhibit linear ranges encompassing those of clinical value.
- 3 February 2014
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 86 (5) , 2559-2564
Label-free Capacitive Diagnostics: Exploiting Local Redox Probe State Occupancy
An electrode surface confined redox group contributes to a substantial potential-dependent interfacial charging that can be sensitively probed and frequency-resolved by impedance-derived capacitance spectroscopy. In utilizing the sensitivity of this charging fingerprint to redox group environment, one can seek to generate derived sensory configurations. Exemplified here through the generation of mixed molecular films comprising ferrocene and antibody receptors to two clinically important targets, the label-free methodology is able to report on human prostatic acid phosphatase (PAP), a tumor marker, with a limit of detection of 11 pM and C-reactive protein with a limit of detection of 28 pM. Both assays exhibit linear ranges encompassing those of clinical value.