Anuj Bellare
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Anuj Bellare has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Alessandro Bistolfi
Department of Traumatology and Rehabilitation, C.T.O. Hospital-A.O.U. Città della Salute e della Scienza, Via Zuretti 29, 10126 Turin, Italy
2 shared publications H.D. Ngo
Department of Orthopedic Surgery, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, United States
2 shared publications- Joel S. Greenberger
University of Pittsburgh
2 shared publications - Michael W. Epperly
Department of Radiation Oncology, UPMC Hillman Cancer Center, Pittsburgh, PA 15232, USA
2 shared publications Thomas S. Thornhill
Department of Orthopedic Surgery, Brigham & Women׳s Hospital, Harvard Medical School, 75 Francis St, MRB 106, Boston, MA 02115, USA
2 shared publicationsA. George
Department of Orthopedic Surgery, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, United States
1 shared publication
Latest Publications
- 15 November 2021
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 41 (4) , S561-S577
Combined injury: irradiation with skin or bone wounds in rodent models
A radiation combined injury is defined as an injury that occurs in the setting of irradiation, such as those expected after a nuclear accident, radiation dispersal device release (a ‘dirty bomb’), or a nuclear weapon detonation. There is much research on irradiation-associated burns and their healing, but there is less known about other injuries sustained in the context of irradiation. Animal models are limited in their correlations to clinical situations but can support research on specific questions about injuries and their healing. Mouse models of irradiation with skin or bone wounds are validated as highly reproducible and quantitative. They show dose-dependent impairment of wound healing, with later recovery. Irradiation-induced delay of bone wound healing was mitigated to different extents by single doses of gramicidin S-nitroxide JP4-039, a plasmid expressing manganese superoxide dismutase, amifostine/WR2721, or the bifunctional sulfoxide MMS-350. These models should be useful for research on mechanisms of radiation dermal and osseous damage and for further development of new radioprotectors. They also provide information of potential relevance to the effects of clinical radiation therapies.
- 15 November 2021
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 41 (4) , S561-S577
Combined injury: irradiation with skin or bone wounds in rodent models
A radiation combined injury is defined as an injury that occurs in the setting of irradiation, such as those expected after a nuclear accident, radiation dispersal device release (a ‘dirty bomb’), or a nuclear weapon detonation. There is much research on irradiation-associated burns and their healing, but there is less known about other injuries sustained in the context of irradiation. Animal models are limited in their correlations to clinical situations but can support research on specific questions about injuries and their healing. Mouse models of irradiation with skin or bone wounds are validated as highly reproducible and quantitative. They show dose-dependent impairment of wound healing, with later recovery. Irradiation-induced delay of bone wound healing was mitigated to different extents by single doses of gramicidin S-nitroxide JP4-039, a plasmid expressing manganese superoxide dismutase, amifostine/WR2721, or the bifunctional sulfoxide MMS-350. These models should be useful for research on mechanisms of radiation dermal and osseous damage and for further development of new radioprotectors. They also provide information of potential relevance to the effects of clinical radiation therapies.
- 1 June 2021
- Published by Elsevier in Ceramics International
- Vol. 47 (12) , 17633-17643
Synthesis and characterization of magnetic and antibacterial nanoparticles as filler in acrylic cements for bone cancer and comorbidities therapy
- 1 June 2021
- Published by Elsevier in Ceramics International
- Vol. 47 (12) , 17633-17643
Synthesis and characterization of magnetic and antibacterial nanoparticles as filler in acrylic cements for bone cancer and comorbidities therapy
- Top Cited PapersOpen Access
Ultra-High Molecular Weight Polyethylene: Influence of the Chemical, Physical and Mechanical Properties on the Wear Behavior. A Review
Ultra-high molecular weight polyethylene (UHMWPE) is the most common bearing material in total joint arthroplasty due to its unique combination of superior mechanical properties and wear resistance over other polymers. A great deal of research in recent decades has focused on further improving its performances, in order to provide durable implants in young and active patients. From “historical”, gamma-air sterilized polyethylenes, to the so-called first and second generation of highly crosslinked materials, a variety of different formulations have progressively appeared in the market. This paper reviews the structure–properties relationship of these materials, with a particular emphasis on the in vitro and in vivo wear performances, through an analysis of the existing literature.
Top Cited PapersOpen AccessUltra-High Molecular Weight Polyethylene: Influence of the Chemical, Physical and Mechanical Properties on the Wear Behavior. A Review
Ultra-high molecular weight polyethylene (UHMWPE) is the most common bearing material in total joint arthroplasty due to its unique combination of superior mechanical properties and wear resistance over other polymers. A great deal of research in recent decades has focused on further improving its performances, in order to provide durable implants in young and active patients. From “historical”, gamma-air sterilized polyethylenes, to the so-called first and second generation of highly crosslinked materials, a variety of different formulations have progressively appeared in the market. This paper reviews the structure–properties relationship of these materials, with a particular emphasis on the in vitro and in vivo wear performances, through an analysis of the existing literature.
- 1 August 2016
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 61, 493-498
J-integral fracture toughness, Tearing modulus and tensile properties of Vitamin E stabilized radiation crosslinked UHMWPE
- 1 August 2016
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 61, 493-498
J-integral fracture toughness, Tearing modulus and tensile properties of Vitamin E stabilized radiation crosslinked UHMWPE
- 21 July 2016
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 133 (43)
Oxidation resistance and abrasive wear resistance of vitamin E stabilized radiation crosslinked ultra‐high molecular weight polyethylene
The effect of gamma radiation on the oxidation and wear resistance of ultra‐high molecular weight polyethylene (UHMWPE) has been extensively studied since these properties are critical for the longevity of UHMWPE components of total joint replacement prostheses. While gamma radiation increases wear resistance of UHMWPE, the free radical generated in the lamellar regions by radiation must be stabilized before oxidative degradation occurs as the polymer ages. Initially, post‐radiation melting conducted to quench free radicals but this treatment also decreases its mechanical properties. Recently, it has been replaced by incorporation of Vitamin E into UHMWPE to combat oxidative degradation. In this study, we assessed wear resistance of Vitamin E stabilized UHMWPE under abrasive wear conditions and oxidation resistance by shelf‐aging irradiated components for 2 years. Equilibrium swelling experiments showed that Vitamin E decreased crosslink density, which affected wear resistance, but oxidation resistance was better preserved with increasing concentration of Vitamin E. © 2016 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2016, 133, 44125.
- 21 July 2016
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 133 (43)
Oxidation resistance and abrasive wear resistance of vitamin E stabilized radiation crosslinked ultra‐high molecular weight polyethylene
The effect of gamma radiation on the oxidation and wear resistance of ultra‐high molecular weight polyethylene (UHMWPE) has been extensively studied since these properties are critical for the longevity of UHMWPE components of total joint replacement prostheses. While gamma radiation increases wear resistance of UHMWPE, the free radical generated in the lamellar regions by radiation must be stabilized before oxidative degradation occurs as the polymer ages. Initially, post‐radiation melting conducted to quench free radicals but this treatment also decreases its mechanical properties. Recently, it has been replaced by incorporation of Vitamin E into UHMWPE to combat oxidative degradation. In this study, we assessed wear resistance of Vitamin E stabilized UHMWPE under abrasive wear conditions and oxidation resistance by shelf‐aging irradiated components for 2 years. Equilibrium swelling experiments showed that Vitamin E decreased crosslink density, which affected wear resistance, but oxidation resistance was better preserved with increasing concentration of Vitamin E. © 2016 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2016, 133, 44125.
- 1 March 2015
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 473 (3) , 936-941
A Comparison of the Efficacy of Various Antioxidants on the Oxidative Stability of Irradiated Polyethylene
Ultrahigh-molecular-weight polyethylene (UHMWPE) is subjected to radiation crosslinking to form highly crosslinked polyethylene (HXLPE), which has improved wear resistance. First-generation HXLPE was subjected to thermal treatment to reduce or quench free radicals that can induce long-term oxidative degeneration. Most recently, antioxidants have been added to HXLPE to induce oxidative resistance rather than by thermal treatment. However, antioxidants can interfere with the efficiency of radiation crosslinking. We sought to identify (1) which antioxidant from among those tested (vitamin E, β-carotene, butylated hydroxytoluene, or pentaerythritol tetrakis [methylene-3-(3,5-di-tert-butyl-4-hydroxyphenyl) propionate]) causes the least reduction of crosslinking; (2) which promotes the greatest oxidative stability; and (3) which had the lowest ratio of oxidation index to crosslink density. Medical-grade polyethylene (PE) resin was blended with 0.1 weight % of the following stabilizers: alpha tocopherol (vitamin E), β-carotene, butylated hydroxytoluene (BHT), and pentaerythritol tetrakis [methylene-3-(3,5-di-tert-butyl-4-hydroxyphenyl) propionate] (a hindered phenol antioxidant [HPAO]). These blends were compression-molded into sheets and subjected to electron beam irradiation to a dose of 100 kGy. Equilibrium swelling experiments were conducted to calculate crosslink density. Each PE was subjected to accelerated aging for a period of 2 weeks and Fourier transform infrared spectroscopy was used to measure the maximum oxidation. Statistical analysis was conducted using analysis of variance with Fisher’s protected least significant difference in which a p value of < 0.05 was used to define a significant difference. The least reduction of crosslinking in antioxidant-containing HXLPE was observed with HPAO, which had a crosslink density (n = 6) of 0.167 (effect size [ES] = 0.87; 95% confidence interval [CI], 0.162–0.173) mol/dm3 compared with 0.139 (ES = 1.57; 95% CI, 0.132–0.146) mol/dm3 (p = 0.020) for BHT, 0.131 (ES = 1.77; 95% CI, 0.123–0.139) mol/dm3 (p = 0.004) for β-carotene, and 0.130 (ES = 1.79; 95% CI, 0.124–0.136) mol/dm3 (p = 0.003) for vitamin E, whereas pure HXLPE had a crosslink density of 0.203 (95% CI, 0.170–0.235) mol/dm3 (p = 0.005). BHT-PE had an oxidation index of 0.21 (ES = 13.14; 95% CI, 0.19–0.22) followed by HPAO-PE, vitamin E-PE and β-carotene-PE, which had oxidation indices of 0.28 (ES = 9.68; 95% CI, 0.28–0.29), 0.29 (ES = 9.59; 95% CI, 0.27–0.30), and 0.35 (ES = 6.68; 95% CI, 0.34–0.37), respectively (p < 0.001 for all groups). BHT-PE had the lowest ratio of oxidation index to crosslink density of the materials tested (1.49, ES = 1.94; 95% CI, 1.32–1.66) followed by HPAO-PE (1.70, ES = 1.52; 95% CI, 1.61–1.80), vitamin E-PE (2.21, ES = 0.52; 95% CI, 2.05–2.38), and β-carotene-PE (2.69, ES = -0.43; 95% CI, 2.46–2.93) compared with control PE (2.47, 95% CI, 2.07–2.88) with β-carotene (p = 0.208) and vitamin E (p = 0.129) not being different from the control. BHT-modified HXLPE was found in this study to have the lowest oxidation index as well as the lowest ratio of oxidation index to crosslink density compared with vitamin E, HPAO, and β-carotene-modified HXLPEs. More comprehensive studies are required such as wear testing using joint simulators as well as biocompatibility studies before BHT-modified HXLPE can be considered for clinical use. BHT is a synthetic antioxidant commonly used in the polymer industry to prevent long-term oxidative degradation and has been approved by the FDA for use in cosmetics and foodstuffs. It may be an attractive potential stabilizer for HXLPE in total joint replacements.
- 1 March 2015
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 473 (3) , 936-941
A Comparison of the Efficacy of Various Antioxidants on the Oxidative Stability of Irradiated Polyethylene
Ultrahigh-molecular-weight polyethylene (UHMWPE) is subjected to radiation crosslinking to form highly crosslinked polyethylene (HXLPE), which has improved wear resistance. First-generation HXLPE was subjected to thermal treatment to reduce or quench free radicals that can induce long-term oxidative degeneration. Most recently, antioxidants have been added to HXLPE to induce oxidative resistance rather than by thermal treatment. However, antioxidants can interfere with the efficiency of radiation crosslinking. We sought to identify (1) which antioxidant from among those tested (vitamin E, β-carotene, butylated hydroxytoluene, or pentaerythritol tetrakis [methylene-3-(3,5-di-tert-butyl-4-hydroxyphenyl) propionate]) causes the least reduction of crosslinking; (2) which promotes the greatest oxidative stability; and (3) which had the lowest ratio of oxidation index to crosslink density. Medical-grade polyethylene (PE) resin was blended with 0.1 weight % of the following stabilizers: alpha tocopherol (vitamin E), β-carotene, butylated hydroxytoluene (BHT), and pentaerythritol tetrakis [methylene-3-(3,5-di-tert-butyl-4-hydroxyphenyl) propionate] (a hindered phenol antioxidant [HPAO]). These blends were compression-molded into sheets and subjected to electron beam irradiation to a dose of 100 kGy. Equilibrium swelling experiments were conducted to calculate crosslink density. Each PE was subjected to accelerated aging for a period of 2 weeks and Fourier transform infrared spectroscopy was used to measure the maximum oxidation. Statistical analysis was conducted using analysis of variance with Fisher’s protected least significant difference in which a p value of < 0.05 was used to define a significant difference. The least reduction of crosslinking in antioxidant-containing HXLPE was observed with HPAO, which had a crosslink density (n = 6) of 0.167 (effect size [ES] = 0.87; 95% confidence interval [CI], 0.162–0.173) mol/dm3 compared with 0.139 (ES = 1.57; 95% CI, 0.132–0.146) mol/dm3 (p = 0.020) for BHT, 0.131 (ES = 1.77; 95% CI, 0.123–0.139) mol/dm3 (p = 0.004) for β-carotene, and 0.130 (ES = 1.79; 95% CI, 0.124–0.136) mol/dm3 (p = 0.003) for vitamin E, whereas pure HXLPE had a crosslink density of 0.203 (95% CI, 0.170–0.235) mol/dm3 (p = 0.005). BHT-PE had an oxidation index of 0.21 (ES = 13.14; 95% CI, 0.19–0.22) followed by HPAO-PE, vitamin E-PE and β-carotene-PE, which had oxidation indices of 0.28 (ES = 9.68; 95% CI, 0.28–0.29), 0.29 (ES = 9.59; 95% CI, 0.27–0.30), and 0.35 (ES = 6.68; 95% CI, 0.34–0.37), respectively (p < 0.001 for all groups). BHT-PE had the lowest ratio of oxidation index to crosslink density of the materials tested (1.49, ES = 1.94; 95% CI, 1.32–1.66) followed by HPAO-PE (1.70, ES = 1.52; 95% CI, 1.61–1.80), vitamin E-PE (2.21, ES = 0.52; 95% CI, 2.05–2.38), and β-carotene-PE (2.69, ES = -0.43; 95% CI, 2.46–2.93) compared with control PE (2.47, 95% CI, 2.07–2.88) with β-carotene (p = 0.208) and vitamin E (p = 0.129) not being different from the control. BHT-modified HXLPE was found in this study to have the lowest oxidation index as well as the lowest ratio of oxidation index to crosslink density compared with vitamin E, HPAO, and β-carotene-modified HXLPEs. More comprehensive studies are required such as wear testing using joint simulators as well as biocompatibility studies before BHT-modified HXLPE can be considered for clinical use. BHT is a synthetic antioxidant commonly used in the polymer industry to prevent long-term oxidative degradation and has been approved by the FDA for use in cosmetics and foodstuffs. It may be an attractive potential stabilizer for HXLPE in total joint replacements.
- 1 December 2014
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 40, 406-412
Influence of crystallization conditions on the tensile properties of radiation crosslinked, vitamin E stabilized UHMWPE
- 1 December 2014
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 40, 406-412
Influence of crystallization conditions on the tensile properties of radiation crosslinked, vitamin E stabilized UHMWPE
- 1 April 2014
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 32, 1-7
Characterization of network parameters for UHMWPE by plane strain compression
- 1 April 2014
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 32, 1-7
Characterization of network parameters for UHMWPE by plane strain compression