Zhiwei Cao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zhiwei Cao has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Yonggang Wen
Nanyang technological university, Singapore, Singapore
10 shared publications - Xin Zhou
Jiangxi Science and Technology Normal University
7 shared publications - Ruihang Wang
Nanyang Technological University, Singapore
5 shared publications - Rui Tan
Nanyang Technological University
4 shared publications - Hongfei Zhu
School of Electronics Engineering and Computer Science Peking University Beijing China
2 shared publications - Jimin Jia
Nanyang Technological University, Singapore
2 shared publications
Latest Publications
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Computational Intelligence Magazine
- Vol. 21  (4) , 81-91
Fusion Intelligence for Digital Twinning AI Data Centers: A Synergistic GenAI-PhyAI Approach [Research Frontier] [Research Frontier]
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Computational Intelligence Magazine
- Vol. 21  (4) , 81-91
Fusion Intelligence for Digital Twinning AI Data Centers: A Synergistic GenAI-PhyAI Approach [Research Frontier] [Research Frontier]
- 19 September 2026
- Published by Elsevier in Journal of Energy Storage
- Vol. 182
Towards interpretable and trustworthy lithium-ion battery prognostics and health management with physics-informed machine learning
- 19 September 2026
- Published by Elsevier in Journal of Energy Storage
- Vol. 182
Towards interpretable and trustworthy lithium-ion battery prognostics and health management with physics-informed machine learning
- 26 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Intelligent Systems
- Vol. 41  (3) , 91-100
Transforming Future Data Center Operations and Management via Physical AI
Data centers (DCs) are critical for artificial intelligence (AI) and the digital economy, with AIDCs introducing new operational challenges. This research proposes a novel Physical AI (PhyAI) framework to advance DC operations and management. The system features three core modules: an industry-grade in-house DC simulation engine for high-fidelity AIDC modeling, an AI engine built on NVIDIA PhysicsNeMo for training and evaluating physics-informed machine learning (PIML) models, and a digital twin platform based on NVIDIA Omniverse. This framework enables the creation of real-time digital twins to digitalize, optimize, and automate future DC operations. A case study demonstrated its effectiveness in predicting thermal and airflow profiles for a large-scale DC in real-time, achieving a median absolute temperature prediction error of 0.18 °C, outperforming traditional CFD/HT simulations. This emerging approach would open doors to several potential research directions for advancing PhyAI in future DC operations.
- 26 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Intelligent Systems
- Vol. 41  (3) , 91-100
Transforming Future Data Center Operations and Management via Physical AI
Data centers (DCs) are critical for artificial intelligence (AI) and the digital economy, with AIDCs introducing new operational challenges. This research proposes a novel Physical AI (PhyAI) framework to advance DC operations and management. The system features three core modules: an industry-grade in-house DC simulation engine for high-fidelity AIDC modeling, an AI engine built on NVIDIA PhysicsNeMo for training and evaluating physics-informed machine learning (PIML) models, and a digital twin platform based on NVIDIA Omniverse. This framework enables the creation of real-time digital twins to digitalize, optimize, and automate future DC operations. A case study demonstrated its effectiveness in predicting thermal and airflow profiles for a large-scale DC in real-time, achieving a median absolute temperature prediction error of 0.18 °C, outperforming traditional CFD/HT simulations. This emerging approach would open doors to several potential research directions for advancing PhyAI in future DC operations.
- 13 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Computing
- Vol. 10  (4) , 730-743
Adaptive Capacity Provisioning for Carbon-Aware Data Centers: A Digital Twin-Based Approach
This paper considers the carbon-aware data center (DC) capacity provisioning problem under uncertain green energy availability and computing demand. To address it, accurate carbon emissions estimation and robust capacity provisioning are necessary. Existing studies mainly consider the carbon footprint of the computing system and merely consider that of the physical facilities, which also contribute significant carbon emissions. Furthermore, their capacity provisioning is neither uncertaintyaware nor adaptive to the dynamic computing demand. To bridge these gaps, we propose an adaptive capacity provisioning framework based on the physics-informed digital twin. We design the digital twin to holistically capture a DC's operational carbon footprint, including both the computing system and the physical facilities. The digital twin is differentiable and established with a collection of physics-informed learnable models that are learned with online operational data. We further address the challenge of capacity provisioning under uncertainties by designing a shrinking horizon model predictive control. The designed capacity planner updates its estimation of future computing demand based on the observable computing system states. At each capacity provisioning round, we solve the capacity provisioning problem using a gradient-based optimization technique with the gradient provided by the digital twin. We extensively evaluate our approach using real operational data from a largescale production data center. Firstly, our digital twin accurately predicts holistic DC energy usage with a relative absolute error of less than 5%, which is accurate according to the industrial rule of thumb. Second, we show that our solution is comparable to the Oracle solution with perfect knowledge about all uncertainties, outperforming the state-of-the-art Predict-then-Plan approach significantly in terms of SLO violation reduction. Furthermore, our approach reduces carbon footprint by 27% compared with the over-provisioning scheme currently adopted by the industry
- 13 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Computing
- Vol. 10  (4) , 730-743
Adaptive Capacity Provisioning for Carbon-Aware Data Centers: A Digital Twin-Based Approach
This paper considers the carbon-aware data center (DC) capacity provisioning problem under uncertain green energy availability and computing demand. To address it, accurate carbon emissions estimation and robust capacity provisioning are necessary. Existing studies mainly consider the carbon footprint of the computing system and merely consider that of the physical facilities, which also contribute significant carbon emissions. Furthermore, their capacity provisioning is neither uncertaintyaware nor adaptive to the dynamic computing demand. To bridge these gaps, we propose an adaptive capacity provisioning framework based on the physics-informed digital twin. We design the digital twin to holistically capture a DC's operational carbon footprint, including both the computing system and the physical facilities. The digital twin is differentiable and established with a collection of physics-informed learnable models that are learned with online operational data. We further address the challenge of capacity provisioning under uncertainties by designing a shrinking horizon model predictive control. The designed capacity planner updates its estimation of future computing demand based on the observable computing system states. At each capacity provisioning round, we solve the capacity provisioning problem using a gradient-based optimization technique with the gradient provided by the digital twin. We extensively evaluate our approach using real operational data from a largescale production data center. Firstly, our digital twin accurately predicts holistic DC energy usage with a relative absolute error of less than 5%, which is accurate according to the industrial rule of thumb. Second, we show that our solution is comparable to the Oracle solution with perfect knowledge about all uncertainties, outperforming the state-of-the-art Predict-then-Plan approach significantly in terms of SLO violation reduction. Furthermore, our approach reduces carbon footprint by 27% compared with the over-provisioning scheme currently adopted by the industry
- Open Access
- 30 April 2024
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Cyber-Physical Systems
- Vol. 8  (2) , 1-26
Green Data Center Cooling Control via Physics-guided Safe Reinforcement Learning
Deep reinforcement learning (DRL) has shown good performance in tackling Markov decision process (MDP) problems. As DRL optimizes a long-term reward, it is a promising approach to improving the energy efficiency of data-center cooling. However, enforcement of thermal safety constraints during DRL’s state exploration is a main challenge. The widely adopted reward-shaping approach adds negative reward when the exploratory action results in unsafety. Thus, it needs to experience sufficient unsafe states before it learns how to prevent unsafety. In this article, we propose a safety-aware DRL framework for data-center cooling control. It applies offline imitation learning and online post-hoc rectification to holistically prevent thermal unsafety during online DRL. In particular, the post-hoc rectification searches for the minimum modification to the DRL-recommended action such that the rectified action will not result in unsafety. The rectification is designed based on a thermal state transition model that is fitted using historical safe operation traces and able to extrapolate the transitions to unsafe states explored by DRL. Extensive evaluation for chilled water and direct expansion-cooled data centers in two climate conditions show that our approach saves 18% to 26.6% of total data-center power compared with conventional control and reduces safety violations by 94.5% to 99% compared with reward shaping. We also extend the proposed framework to address data centers with non-uniform temperature distributions for detailed safety considerations. The evaluation shows that our approach saves 14% power usage compared with the PID control while addressing safety compliance during the training.
- 30 April 2024
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Cyber-Physical Systems
- Vol. 8  (2) , 1-26
Open AccessGreen Data Center Cooling Control via Physics-guided Safe Reinforcement Learning
Deep reinforcement learning (DRL) has shown good performance in tackling Markov decision process (MDP) problems. As DRL optimizes a long-term reward, it is a promising approach to improving the energy efficiency of data-center cooling. However, enforcement of thermal safety constraints during DRL’s state exploration is a main challenge. The widely adopted reward-shaping approach adds negative reward when the exploratory action results in unsafety. Thus, it needs to experience sufficient unsafe states before it learns how to prevent unsafety. In this article, we propose a safety-aware DRL framework for data-center cooling control. It applies offline imitation learning and online post-hoc rectification to holistically prevent thermal unsafety during online DRL. In particular, the post-hoc rectification searches for the minimum modification to the DRL-recommended action such that the rectified action will not result in unsafety. The rectification is designed based on a thermal state transition model that is fitted using historical safe operation traces and able to extrapolate the transitions to unsafe states explored by DRL. Extensive evaluation for chilled water and direct expansion-cooled data centers in two climate conditions show that our approach saves 18% to 26.6% of total data-center power compared with conventional control and reduces safety violations by 94.5% to 99% compared with reward shaping. We also extend the proposed framework to address data centers with non-uniform temperature distributions for detailed safety considerations. The evaluation shows that our approach saves 14% power usage compared with the PID control while addressing safety compliance during the training.
- Open Access
- 26 October 2023
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Modeling and Computer Simulation
- Vol. 33  (4) , 1-24
Toward Data Center Digital Twins via Knowledge-based Model Calibration and Reduction
Computational fluid dynamics (CFD) models have been widely used for prototyping data centers. Evolving them into high-fidelity and real-time digital twins is desirable for the online operations of data centers. However, CFD models often have unsatisfactory accuracy and high computation overhead. Manually calibrating the CFD model parameters is tedious and labor-intensive. Existing automatic calibration approaches apply heuristics to search the model configurations. However, each search step requires a long-lasting process of repeatedly solving the CFD model, rendering them impractical, especially for complex CFD models. This article presents Kalibre , a knowledge-based neural surrogate approach that calibrates a CFD model by iterating four steps of (i) training a neural surrogate model, (ii) finding the optimal parameters through neural surrogate retraining, (iii) configuring the found parameters back to the CFD model, and (iv) validating the CFD model using sensor-measured data. Thus, the parameter search is offloaded to the lightweight neural surrogate. To speed up Kalibre’s convergence, we incorporate prior knowledge in training data initialization and surrogate architecture design. With about ten hours of computation on a 64-core processor, Kalibre achieves mean absolute errors (MAEs) of 0.57°C and 0.88°C in calibrating the CFD models of two production data halls hosting thousands of servers. To accelerate CFD-based simulation, we further propose Kalibreduce that incorporates the energy balance principle to reduce the order of the calibrated CFD model. Evaluation shows the model reduction only introduces 0.1°C to 0.27°C extra errors while accelerating the CFD-based simulations by thousand times.
- 26 October 2023
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Modeling and Computer Simulation
- Vol. 33  (4) , 1-24
Open AccessToward Data Center Digital Twins via Knowledge-based Model Calibration and Reduction
Computational fluid dynamics (CFD) models have been widely used for prototyping data centers. Evolving them into high-fidelity and real-time digital twins is desirable for the online operations of data centers. However, CFD models often have unsatisfactory accuracy and high computation overhead. Manually calibrating the CFD model parameters is tedious and labor-intensive. Existing automatic calibration approaches apply heuristics to search the model configurations. However, each search step requires a long-lasting process of repeatedly solving the CFD model, rendering them impractical, especially for complex CFD models. This article presents Kalibre , a knowledge-based neural surrogate approach that calibrates a CFD model by iterating four steps of (i) training a neural surrogate model, (ii) finding the optimal parameters through neural surrogate retraining, (iii) configuring the found parameters back to the CFD model, and (iv) validating the CFD model using sensor-measured data. Thus, the parameter search is offloaded to the lightweight neural surrogate. To speed up Kalibre’s convergence, we incorporate prior knowledge in training data initialization and surrogate architecture design. With about ten hours of computation on a 64-core processor, Kalibre achieves mean absolute errors (MAEs) of 0.57°C and 0.88°C in calibrating the CFD models of two production data halls hosting thousands of servers. To accelerate CFD-based simulation, we further propose Kalibreduce that incorporates the energy balance principle to reduce the order of the calibrated CFD model. Evaluation shows the model reduction only introduces 0.1°C to 0.27°C extra errors while accelerating the CFD-based simulations by thousand times.
- Open Access
- 16 June 2023
- Published by Association for Computing Machinery (ACM)
- p. 333-346
Toward Model-Assisted Safe Reinforcement Learning for Data Center Cooling Control: A Lyapunov-based Approach
This paper considers intelligent data center cooling control via the Deep Reinforcement Learning (DRL) approach to improve data center sustainability. Existing DRL-based controllers are trained with a simplified data hall thermodynamic model which assumes uniform room temperature distribution. This assumption is not valid for a real-world data center with highly nonuniform temperature distribution. Furthermore, most of them cannot guarantee thermal safety during the DRL learning process. To bridge these gaps, we propose LyaSafe, a model-assisted safe DRL approach for data center cooling control. To address the safety evaluation issue, we develop a coupled model that combines a differentiable surrogate data hall thermodynamics model with the energy model. It can simulate both data hall temperature distribution and the facility energy consumption. To address safe learning, we introduce a novel constrained Markov Decision Process (CMDP) formulation for data center cooling control by considering the Rack Cooling Index (RCI), the best-practice metric for evaluating compliance with ASHRAE data center thermal guidelines. The objective is to minimize data center carbon footprints while regulating the RCI within a threshold. We first derive the safety set based on the concept of the virtual queue and Lyapunov stability theory. Next, we rectify unsafe actions from the DRL agent by projecting them to the safety set. We evaluate LyaSafe in a data center hosting 20 racks and 299 servers. Evaluation results show that LyaSafe can ensure strict safety during the DRL learning while achieving up to 50 metric tons of annual carbon emission savings using Singapore’s statistics. Moreover, we conduct root cause analysis for the savings, revealing the importance of joint control of the data hall and the chiller plant.
- 16 June 2023
- Published by Association for Computing Machinery (ACM)
- p. 333-346
Open AccessToward Model-Assisted Safe Reinforcement Learning for Data Center Cooling Control: A Lyapunov-based Approach
This paper considers intelligent data center cooling control via the Deep Reinforcement Learning (DRL) approach to improve data center sustainability. Existing DRL-based controllers are trained with a simplified data hall thermodynamic model which assumes uniform room temperature distribution. This assumption is not valid for a real-world data center with highly nonuniform temperature distribution. Furthermore, most of them cannot guarantee thermal safety during the DRL learning process. To bridge these gaps, we propose LyaSafe, a model-assisted safe DRL approach for data center cooling control. To address the safety evaluation issue, we develop a coupled model that combines a differentiable surrogate data hall thermodynamics model with the energy model. It can simulate both data hall temperature distribution and the facility energy consumption. To address safe learning, we introduce a novel constrained Markov Decision Process (CMDP) formulation for data center cooling control by considering the Rack Cooling Index (RCI), the best-practice metric for evaluating compliance with ASHRAE data center thermal guidelines. The objective is to minimize data center carbon footprints while regulating the RCI within a threshold. We first derive the safety set based on the concept of the virtual queue and Lyapunov stability theory. Next, we rectify unsafe actions from the DRL agent by projecting them to the safety set. We evaluate LyaSafe in a data center hosting 20 racks and 299 servers. Evaluation results show that LyaSafe can ensure strict safety during the DRL learning while achieving up to 50 metric tons of annual carbon emission savings using Singapore’s statistics. Moreover, we conduct root cause analysis for the savings, revealing the importance of joint control of the data hall and the chiller plant.
- Open Access
- 16 June 2023
- Published by Association for Computing Machinery (ACM)
- p. 114-126
Phyllis: Physics-Informed Lifelong Reinforcement Learning for Data Center Cooling Control
Deep reinforcement learning (DRL) has shown good performance in data center cooling control for improving energy efficiency. The main challenge in deploying the DRL agent to real-world data centers is how to quickly adapt the agent to the ever-changing system with thermal safety compliance. Existing approaches rely on DRL’s native fine-tuning or a learned data-driven dynamics model to assist the adaptation. However, they require long-term unsafe exploration before the agent or the model can capture a new environment. This paper proposes Phyllis, a physics-informed reinforcement learning approach to assist the DRL agent’s lifelong learning under evolving data center environment. Phyllis first identifies a transition model to capture the data hall thermodynamics in the offline stage. When the environment changes in the online stage, Phyllis assists the adaptation by i) supervising safe data collection with the identified transition model, ii) fitting power usage and residual thermal models, iii) pretraining the agent by interacting with these models, and iv) deploying the agent for further fine-tuning. Phyllis uses known physical laws to inform the transition and power models for improving the extrapolation ability to unseen states. Extensive evaluation for two simulated data centers with different system changes shows that Phyllis saves 5.7% to 13.8% energy usage compared with feedback cooling control and adapts to new environments 8x to 10x faster than fine-tuning with at most 0.74°C temperature overshoot.
- 16 June 2023
- Published by Association for Computing Machinery (ACM)
- p. 114-126
Open AccessPhyllis: Physics-Informed Lifelong Reinforcement Learning for Data Center Cooling Control
Deep reinforcement learning (DRL) has shown good performance in data center cooling control for improving energy efficiency. The main challenge in deploying the DRL agent to real-world data centers is how to quickly adapt the agent to the ever-changing system with thermal safety compliance. Existing approaches rely on DRL’s native fine-tuning or a learned data-driven dynamics model to assist the adaptation. However, they require long-term unsafe exploration before the agent or the model can capture a new environment. This paper proposes Phyllis, a physics-informed reinforcement learning approach to assist the DRL agent’s lifelong learning under evolving data center environment. Phyllis first identifies a transition model to capture the data hall thermodynamics in the offline stage. When the environment changes in the online stage, Phyllis assists the adaptation by i) supervising safe data collection with the identified transition model, ii) fitting power usage and residual thermal models, iii) pretraining the agent by interacting with these models, and iv) deploying the agent for further fine-tuning. Phyllis uses known physical laws to inform the transition and power models for improving the extrapolation ability to unseen states. Extensive evaluation for two simulated data centers with different system changes shows that Phyllis saves 5.7% to 13.8% energy usage compared with feedback cooling control and adapts to new environments 8x to 10x faster than fine-tuning with at most 0.74°C temperature overshoot.
- 31 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Computing
- Vol. 9  (3) , 236-248
Data Center Sustainability: Revisits and Outlooks
As energy-intensive entities, data centers are associated with significant environmental impacts, making their sustainability a subject of growing interest in recent years. In this article, we revisit data center sustainability and propose a forward-looking vision for improving data center sustainability. We argue that data center sustainability encompasses more than just energy efficiency and must be evaluated and optimized through a multi-faceted approach. To this end, we first present an overview of the sustainability metrics from five aspects. After that, we demonstrate the sustainability status of the latest data centers utilizing publicly available data center sustainability ratings. Furthermore, we examine the evolution of data center sustainability standards in Singapore to highlight several trending features. Based on the analysis, we identify several key elements of sustainable data centers. We then propose the Cognitive Digital Twin (CDT) architecture, which incorporates a digital twin engine for system-wide simulation and a decision engine for optimal control to improve data center sustainability. A case study is performed to optimize the chiller plant efficiency of a production data center in Singapore. The results demonstrate that the CDT can improve chiller plant energy efficiency by 5%, indicating around 140 metric tons of annual carbon emission savings.
- 31 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Computing
- Vol. 9  (3) , 236-248
Data Center Sustainability: Revisits and Outlooks
As energy-intensive entities, data centers are associated with significant environmental impacts, making their sustainability a subject of growing interest in recent years. In this article, we revisit data center sustainability and propose a forward-looking vision for improving data center sustainability. We argue that data center sustainability encompasses more than just energy efficiency and must be evaluated and optimized through a multi-faceted approach. To this end, we first present an overview of the sustainability metrics from five aspects. After that, we demonstrate the sustainability status of the latest data centers utilizing publicly available data center sustainability ratings. Furthermore, we examine the evolution of data center sustainability standards in Singapore to highlight several trending features. Based on the analysis, we identify several key elements of sustainable data centers. We then propose the Cognitive Digital Twin (CDT) architecture, which incorporates a digital twin engine for system-wide simulation and a decision engine for optimal control to improve data center sustainability. A case study is performed to optimize the chiller plant efficiency of a production data center in Singapore. The results demonstrate that the CDT can improve chiller plant energy efficiency by 5%, indicating around 140 metric tons of annual carbon emission savings.
- Top Cited Papers
- 22 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Communications Surveys & Tutorials
- Vol. 24  (2) , 895-936
Toward a Systematic Survey for Carbon Neutral Data Centers
Data centers are experiencing unprecedented growth as the fourth industrial revolution’s supporting pillars and the engine for the future digitalized world. However, data centers are carbon-intensive enterprises due to their massive energy consumption, and it is estimated that data center industry will account for 8% of global carbon emissions by 2030. Meanwhile, both technological and policy instruments for reducing or even neutralizing data center carbon emissions have not been thoroughly investigated, despite the fact that several global cloud providers including Google and Facebook, have pledged to achieve carbon neutrality in their hyperscale data centers. To bridge this gap, this survey paper proposes a roadmap towards carbon-neutral data centers that takes into account both policy instruments and technological methodologies. We begin by presenting the carbon footprint of data centers, as well as some insights into the major sources of carbon emissions. Following that, carbon neutrality plans for major global cloud providers are discussed to summarize current industrial efforts in this direction. In what follows, we introduce the carbon market as a policy instrument to explain how to offset data center carbon emissions in a cost-efficient manner. On the technological front, we propose achieving carbon-neutral data centers by increasing renewable energy penetration, improving energy efficiency, and boosting energy circulation simultaneously. A comprehensive review of existing technologies on these three topics is elaborated subsequently. Based on this, a multi-pronged approach towards carbon neutrality is envisioned and a digital twin-powered industrial artificial intelligence (AI) framework is proposed to make this solution a reality. Furthermore, three key scientific challenges for putting such a framework in place are discussed. Finally, several applications for this framework are presented to demonstrate its enormous potential.
- 22 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Communications Surveys & Tutorials
- Vol. 24  (2) , 895-936
Top Cited PapersToward a Systematic Survey for Carbon Neutral Data Centers
Data centers are experiencing unprecedented growth as the fourth industrial revolution’s supporting pillars and the engine for the future digitalized world. However, data centers are carbon-intensive enterprises due to their massive energy consumption, and it is estimated that data center industry will account for 8% of global carbon emissions by 2030. Meanwhile, both technological and policy instruments for reducing or even neutralizing data center carbon emissions have not been thoroughly investigated, despite the fact that several global cloud providers including Google and Facebook, have pledged to achieve carbon neutrality in their hyperscale data centers. To bridge this gap, this survey paper proposes a roadmap towards carbon-neutral data centers that takes into account both policy instruments and technological methodologies. We begin by presenting the carbon footprint of data centers, as well as some insights into the major sources of carbon emissions. Following that, carbon neutrality plans for major global cloud providers are discussed to summarize current industrial efforts in this direction. In what follows, we introduce the carbon market as a policy instrument to explain how to offset data center carbon emissions in a cost-efficient manner. On the technological front, we propose achieving carbon-neutral data centers by increasing renewable energy penetration, improving energy efficiency, and boosting energy circulation simultaneously. A comprehensive review of existing technologies on these three topics is elaborated subsequently. Based on this, a multi-pronged approach towards carbon neutrality is envisioned and a digital twin-powered industrial artificial intelligence (AI) framework is proposed to make this solution a reality. Furthermore, three key scientific challenges for putting such a framework in place are discussed. Finally, several applications for this framework are presented to demonstrate its enormous potential.