Akihiko Tsukahara
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Akihiko Tsukahara has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Keita Tanaka
Graduate School of Tokyo Denki University
2 shared publications - Akinori Ueno
Department of Electrical and Electronic Engineering, Tokyo Denki University, Tokyo, Japan
1 shared publication - Hiroki Miyanaga
Sumitomo Heavy Industries, Ltd., Yokosuka 237-0061, Japan
1 shared publication - Hiromu Sakai
Faculty of Science and Engineering, School of Creative Science and Engineering, Waseda University
1 shared publication Keita Tanaka
Graduate School of Electronic and Mechanical Engineering Tokyo Denki University Hatoyama‐machi Hiki‐gun Saitama
1 shared publication- Nina Pilyugina
Graduate School of Advanced Science and Technology, Tokyo Denki University, Hiki-gun, Saitama 350-0394, Japan
1 shared publication
Latest Publications
- Open Access
Superconducting Self-Shielded and Zero-Boil-Off Magnetoencephalogram Systems: A Dry Phantom Evaluation
Magnetoencephalography (MEG) systems are advanced neuroimaging tools used to measure the magnetic fields produced by neuronal activity in the human brain. However, they require significant amounts of liquid helium to keep the superconducting quantum interference device (SQUID) sensors in a stable superconducting state. Additionally, MEG systems must be installed in a magnetically shielded room to minimize interference from external magnetic fields. We have developed an advanced MEG system that incorporates a superconducting magnetic shield and a zero-boil-off system. This system overcomes the typical limitations of traditional MEG systems, such as the frequent need for liquid helium refills and the spatial constraints imposed by magnetically shielded rooms. To validate the system, we conducted an evaluation using signal source estimation. This involved a phantom with 50 current sources of known location and magnitude under active zero-boil-off conditions. Our evaluations focused on the precision of the magnetic field distribution and the quantification of estimation errors. We achieved a consistent magnetic field distribution that matched the source current, maintaining an estimation error margin within 3.5 mm, regardless of the frequency of the signal source current. These findings affirm the practicality and efficacy of the system.
Open AccessSuperconducting Self-Shielded and Zero-Boil-Off Magnetoencephalogram Systems: A Dry Phantom Evaluation
Magnetoencephalography (MEG) systems are advanced neuroimaging tools used to measure the magnetic fields produced by neuronal activity in the human brain. However, they require significant amounts of liquid helium to keep the superconducting quantum interference device (SQUID) sensors in a stable superconducting state. Additionally, MEG systems must be installed in a magnetically shielded room to minimize interference from external magnetic fields. We have developed an advanced MEG system that incorporates a superconducting magnetic shield and a zero-boil-off system. This system overcomes the typical limitations of traditional MEG systems, such as the frequent need for liquid helium refills and the spatial constraints imposed by magnetically shielded rooms. To validate the system, we conducted an evaluation using signal source estimation. This involved a phantom with 50 current sources of known location and magnitude under active zero-boil-off conditions. Our evaluations focused on the precision of the magnetic field distribution and the quantification of estimation errors. We achieved a consistent magnetic field distribution that matched the source current, maintaining an estimation error margin within 3.5 mm, regardless of the frequency of the signal source current. These findings affirm the practicality and efficacy of the system.
- Open Access
FPGA-Based Processor for Continual Capacitive-Coupling Impedance Spectroscopy and Circuit Parameter Estimation
In principle, the recently proposed capacitive-coupling impedance spectroscopy (CIS) has the capability to acquire frequency spectra of complex electrical impedance sequentially on a millisecond timescale. Even when the measured object with time-varying unknown resistance Rx is capacitively coupled with the measurement electrodes with time-varying unknown capacitance Cx, CIS can be measured. As a proof of concept, this study aimed to develop a prototype that implemented the novel algorithm of CIS and circuit parameter estimation to verify whether the frequency spectra and circuit parameters could be obtained in milliseconds and whether time-varying impedance could be measured. This study proposes a dedicated processor that was implemented as field-programmable gate arrays to perform CIS, estimate Rx and Cx, and their digital-to-analog conversions at a certain time, and to repeat them continually. The proposed processor executed the entire sequence in the order of milliseconds. Combined with a front-end nonsinusoidal oscillator and interfacing circuits, the processor estimated the fixed Rx and fixed Cx with reasonable accuracy. Additionally, the combined system with the processor succeeded in detecting a quick optical response in the resistance of the cadmium sulfide (CdS) photocell connected in series with a capacitor, and in reading out their resistance and capacitance independently as voltages in real-time.
Open AccessFPGA-Based Processor for Continual Capacitive-Coupling Impedance Spectroscopy and Circuit Parameter Estimation
In principle, the recently proposed capacitive-coupling impedance spectroscopy (CIS) has the capability to acquire frequency spectra of complex electrical impedance sequentially on a millisecond timescale. Even when the measured object with time-varying unknown resistance Rx is capacitively coupled with the measurement electrodes with time-varying unknown capacitance Cx, CIS can be measured. As a proof of concept, this study aimed to develop a prototype that implemented the novel algorithm of CIS and circuit parameter estimation to verify whether the frequency spectra and circuit parameters could be obtained in milliseconds and whether time-varying impedance could be measured. This study proposes a dedicated processor that was implemented as field-programmable gate arrays to perform CIS, estimate Rx and Cx, and their digital-to-analog conversions at a certain time, and to repeat them continually. The proposed processor executed the entire sequence in the order of milliseconds. Combined with a front-end nonsinusoidal oscillator and interfacing circuits, the processor estimated the fixed Rx and fixed Cx with reasonable accuracy. Additionally, the combined system with the processor succeeded in detecting a quick optical response in the resistance of the cadmium sulfide (CdS) photocell connected in series with a capacitor, and in reading out their resistance and capacitance independently as voltages in real-time.
- Open Access
Comparing Methods of Feature Extraction of Brain Activities for Octave Illusion Classification Using Machine Learning
The aim of this study was to find an efficient method to determine features that characterize octave illusion data. Specifically, this study compared the efficiency of several automatic feature selection methods for automatic feature extraction of the auditory steady-state responses (ASSR) data in brain activities to distinguish auditory octave illusion and nonillusion groups by the difference in ASSR amplitudes using machine learning. We compared univariate selection, recursive feature elimination, principal component analysis, and feature importance by testifying the results of feature selection methods by using several machine learning algorithms: linear regression, random forest, and support vector machine. The univariate selection with the SVM as the classification method showed the highest accuracy result, 75%, compared to 66.6% without using feature selection. The received results will be used for future work on the explanation of the mechanism behind the octave illusion phenomenon and creating an algorithm for automatic octave illusion classification.
Open AccessComparing Methods of Feature Extraction of Brain Activities for Octave Illusion Classification Using Machine Learning
The aim of this study was to find an efficient method to determine features that characterize octave illusion data. Specifically, this study compared the efficiency of several automatic feature selection methods for automatic feature extraction of the auditory steady-state responses (ASSR) data in brain activities to distinguish auditory octave illusion and nonillusion groups by the difference in ASSR amplitudes using machine learning. We compared univariate selection, recursive feature elimination, principal component analysis, and feature importance by testifying the results of feature selection methods by using several machine learning algorithms: linear regression, random forest, and support vector machine. The univariate selection with the SVM as the classification method showed the highest accuracy result, 75%, compared to 66.6% without using feature selection. The received results will be used for future work on the explanation of the mechanism behind the octave illusion phenomenon and creating an algorithm for automatic octave illusion classification.
- 20 November 2020
- Published by Wiley in Electronics and Communications in Japan
- Vol. 104 (1) , 53-64
A design of EEGNet‐based inference processor for pattern recognition of EEG using FPGA
In recent years, brain‐machine interface (BMI) is attracting attention. BMI is a technology that enables machine operation using biological signals such as EEG. For further advancement of BMI technology, there is a need for advanced BMI devices. Therefore, the purpose of this study is development of BMI hardware specialized for handling EEG as an interface for human adaptive mechatronics (HAM) that know human's state and operate according to the state. As one of the examinations, we are constructing a pattern recognition processor for EEG in real time on Field Programmable Gate Array (FPGA), which is an LSI that can reconfigure the processor. This paper reports on the designed EEGNet processor and the result of logic circuit simulation and implementation.
- 20 November 2020
- Published by Wiley in Electronics and Communications in Japan
- Vol. 104 (1) , 53-64
A design of EEGNet‐based inference processor for pattern recognition of EEG using FPGA
In recent years, brain‐machine interface (BMI) is attracting attention. BMI is a technology that enables machine operation using biological signals such as EEG. For further advancement of BMI technology, there is a need for advanced BMI devices. Therefore, the purpose of this study is development of BMI hardware specialized for handling EEG as an interface for human adaptive mechatronics (HAM) that know human's state and operate according to the state. As one of the examinations, we are constructing a pattern recognition processor for EEG in real time on Field Programmable Gate Array (FPGA), which is an LSI that can reconfigure the processor. This paper reports on the designed EEGNet processor and the result of logic circuit simulation and implementation.