Youkeun K. Oh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Youkeun K. Oh has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Yeseop Park
Department of Mechanical Engineering, Hongik University, Seoul, Republic of Korea
3 shared publications Choongsoo Shin
1 shared publication- Dokshin Lim
Hongik University, Seoul, Republic of Korea
1 shared publication Kyoungmin Choi
Hongik University
1 shared publicationMinyung Kim
Hongik University
1 shared publication- Seunghee Yu
Department of Mechanical Engineering, Hongik University, Seoul, Republic of Korea
1 shared publication
Latest Publications
- 24 April 2026
- Published by Springer Nature in Annals of Biomedical Engineering
- p. 1-12
Quantitative Assessment of Cannula Kinematics in Liposuction Surgical Procedures Using a Marker-Based Tracking System
Purpose The aim is to develop a reliable, objective, and quantitative system for measuring and analyzing the movement of the cannula tip, which is used in liposuction. Methods The customized tracking system was designed using an infrared marker set and stereo vision. It was utilized to accurately track and quantify cannula tip movements during liposuction surgery. The accuracy of this system was validated by comparing its measurements to a commercial motion-tracking system. In addition, a new metric, the normalized cannula movement index (nCMI), was supposed to objectively assess cannula stroke cycles, quantify spatial distribution, and evaluate handling techniques. The developed tracking system exhibited excellent accuracy, with results differing by only approximately 0.9% from the commercial system, confirming its reliability and precision. Results This system enables quantitative comparisons of region-wise stroke distribution and stroke speed across procedures. The proposed nCMI can provide an objective, region-level descriptor of cannula handling patterns that could support comparative assessment. As a result, it can provide consistent and quantitative analysis results. Through quantitative indicators such as stroke cycle and nCMI, it is possible to effectively perform objective evaluations of the liposuction procedures and outcomes. Conclusion Consequently, this study provides a novel tool for objective assessment of surgical techniques. It could contribute to improving surgeon training, predicting postoperative complications, and optimizing the liposuction procedure.
- 24 April 2026
- Published by Springer Nature in Annals of Biomedical Engineering
- p. 1-12
Quantitative Assessment of Cannula Kinematics in Liposuction Surgical Procedures Using a Marker-Based Tracking System
Purpose The aim is to develop a reliable, objective, and quantitative system for measuring and analyzing the movement of the cannula tip, which is used in liposuction. Methods The customized tracking system was designed using an infrared marker set and stereo vision. It was utilized to accurately track and quantify cannula tip movements during liposuction surgery. The accuracy of this system was validated by comparing its measurements to a commercial motion-tracking system. In addition, a new metric, the normalized cannula movement index (nCMI), was supposed to objectively assess cannula stroke cycles, quantify spatial distribution, and evaluate handling techniques. The developed tracking system exhibited excellent accuracy, with results differing by only approximately 0.9% from the commercial system, confirming its reliability and precision. Results This system enables quantitative comparisons of region-wise stroke distribution and stroke speed across procedures. The proposed nCMI can provide an objective, region-level descriptor of cannula handling patterns that could support comparative assessment. As a result, it can provide consistent and quantitative analysis results. Through quantitative indicators such as stroke cycle and nCMI, it is possible to effectively perform objective evaluations of the liposuction procedures and outcomes. Conclusion Consequently, this study provides a novel tool for objective assessment of surgical techniques. It could contribute to improving surgeon training, predicting postoperative complications, and optimizing the liposuction procedure.
- 21 March 2026
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 54 (10) , 1-10
Effect of Internal Tibial Torque on ACL Tear at the Femoral Enthesis
Purpose This study aims to investigate the relationship between increasing internal tibial torque (ITT) and the distribution of stress on the anterior cruciate ligament (ACL), with a focus on identifying the location of tear initiation and propagation. In particular, the study emphasizes the femoral enthesis as a potential site of geometric vulnerability during pivot landing. Methods A three-dimensional finite element model of the ACL was developed and combined with an extended finite element method framework to simulate tear initiation and propagation. The model was driven by torque-indexed, three-dimensional knee kinematics obtained from previous in silico knee simulations that were validated against in vitro cadaveric knee tests (15 specimens). ITT was applied in graded steps to reproduce pivot landing–relevant internal rotation loading. Stress/strain fields were evaluated, and tear initiation/propagation were tracked to quantify damage evolution. Results Maximum von Mises stress increased proportionally with ITT and localized near the femoral enthesis, with a mean increase of 26.56% for each 5Nm increase in torque. Stress concentration consistently occurred at the posterolateral bundle attachment on the femoral side, where tear initiation was predicted. With further ITT increases, the tear propagated from the femoral enthesis, indicating a torque-dependent damage progression mechanism. Conclusion Increased ITT produced reproducible stress/strain concentration at the femoral enthesis, supporting structural vulnerability during pivot landing. This approach extends stress-only analyses by predicting rupture initiation and tear progression. These findings may inform prevention and rehabilitation by highlighting the roles of ITT and femoral insertion morphology in ACL tear initiation and propagation.
- 21 March 2026
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 54 (10) , 1-10
Effect of Internal Tibial Torque on ACL Tear at the Femoral Enthesis
Purpose This study aims to investigate the relationship between increasing internal tibial torque (ITT) and the distribution of stress on the anterior cruciate ligament (ACL), with a focus on identifying the location of tear initiation and propagation. In particular, the study emphasizes the femoral enthesis as a potential site of geometric vulnerability during pivot landing. Methods A three-dimensional finite element model of the ACL was developed and combined with an extended finite element method framework to simulate tear initiation and propagation. The model was driven by torque-indexed, three-dimensional knee kinematics obtained from previous in silico knee simulations that were validated against in vitro cadaveric knee tests (15 specimens). ITT was applied in graded steps to reproduce pivot landing–relevant internal rotation loading. Stress/strain fields were evaluated, and tear initiation/propagation were tracked to quantify damage evolution. Results Maximum von Mises stress increased proportionally with ITT and localized near the femoral enthesis, with a mean increase of 26.56% for each 5Nm increase in torque. Stress concentration consistently occurred at the posterolateral bundle attachment on the femoral side, where tear initiation was predicted. With further ITT increases, the tear propagated from the femoral enthesis, indicating a torque-dependent damage progression mechanism. Conclusion Increased ITT produced reproducible stress/strain concentration at the femoral enthesis, supporting structural vulnerability during pivot landing. This approach extends stress-only analyses by predicting rupture initiation and tear progression. These findings may inform prevention and rehabilitation by highlighting the roles of ITT and femoral insertion morphology in ACL tear initiation and propagation.
- 28 February 2026
- Published by The Korean Society of Manufacturing Process Engineers in Journal of the Korean Society of Manufacturing Process Engineers
- Vol. 25 (2) , 63-69
Digital Twin-based Synthetic Data Generation and Domain Adaptation for Object Detection in Unmanned Laboratory Robot Vision Systems
- 28 February 2026
- Published by The Korean Society of Manufacturing Process Engineers in Journal of the Korean Society of Manufacturing Process Engineers
- Vol. 25 (2) , 63-69
Digital Twin-based Synthetic Data Generation and Domain Adaptation for Object Detection in Unmanned Laboratory Robot Vision Systems
- Open Access
- 11 February 2026
- Published by Elsevier in SSRN Electronic Journal
Effect of Femoral Insertion Curvature on Non-contact Anterior Cruciate Ligament Tear Patterns: A Finite Element Study
Background and ObjectiveAnterior cruciate ligament (ACL) injuries most commonly occur near the femoral insertion, involving both proximal and midsubstance regions. Although internal tibial torque has been shown to induce stress concentration at the femoral insertion and explain proximal tear initiation, this mechanism alone does not sufficiently account for the high prevalence of midsubstance ACL tears observed clinically. Therefore, the aim of this study is to determine whether the shape of the ACL's femoral insertion influences the location of an initial ACL tear under repetitive loading conditions using finite element modeling.MethodsThree-dimensional finite element (FE) models of the ACL incorporating a hyperelastic material formulation with damage mechanics were developed to simulate tear initiation and its propagation. The curvature of the femoral attachment site was extracted from histological images and implemented in the FE model. Physiologic knee loading conditions, including internal tibial torque, were applied based on in silico knee simulations, which were previously validated against in vitro knee experiments involving 15 human cadaveric knee specimens.ResultsThe initiation of ACL tear occurred when the internal tibial torque with its peak magnitude to be 25 Nm applied. Increasing the curvature radius at the femoral insertion altered the stress distribution patterns along the ligament and shifted the ACL tear location from the proximal region toward the midsubstance region. This shift was associated with the changes in the tear propagation angle of up to 42.5%.ConclusionsFemoral insertion curvature significantly influenced ACL tear location under noncontact loading. Increasing curvature radius shifted tear initiation from the proximal region toward the midsubstance and altered stress distribution patterns beyond torque driven effects. These findings suggest that structural variation at the femoral attachment contributes to clinically observed midsubstance tears and should be considered when evaluating injury risk and developing prevention strategies.
- 11 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessEffect of Femoral Insertion Curvature on Non-contact Anterior Cruciate Ligament Tear Patterns: A Finite Element Study
Background and ObjectiveAnterior cruciate ligament (ACL) injuries most commonly occur near the femoral insertion, involving both proximal and midsubstance regions. Although internal tibial torque has been shown to induce stress concentration at the femoral insertion and explain proximal tear initiation, this mechanism alone does not sufficiently account for the high prevalence of midsubstance ACL tears observed clinically. Therefore, the aim of this study is to determine whether the shape of the ACL's femoral insertion influences the location of an initial ACL tear under repetitive loading conditions using finite element modeling.MethodsThree-dimensional finite element (FE) models of the ACL incorporating a hyperelastic material formulation with damage mechanics were developed to simulate tear initiation and its propagation. The curvature of the femoral attachment site was extracted from histological images and implemented in the FE model. Physiologic knee loading conditions, including internal tibial torque, were applied based on in silico knee simulations, which were previously validated against in vitro knee experiments involving 15 human cadaveric knee specimens.ResultsThe initiation of ACL tear occurred when the internal tibial torque with its peak magnitude to be 25 Nm applied. Increasing the curvature radius at the femoral insertion altered the stress distribution patterns along the ligament and shifted the ACL tear location from the proximal region toward the midsubstance region. This shift was associated with the changes in the tear propagation angle of up to 42.5%.ConclusionsFemoral insertion curvature significantly influenced ACL tear location under noncontact loading. Increasing curvature radius shifted tear initiation from the proximal region toward the midsubstance and altered stress distribution patterns beyond torque driven effects. These findings suggest that structural variation at the femoral attachment contributes to clinically observed midsubstance tears and should be considered when evaluating injury risk and developing prevention strategies.
- 16 June 2022
- Published by Springer Nature
- p. 540-547
Vision-Based Cooking Assistance System for Visually Impaired People
- 16 June 2022
- Published by Springer Nature
- p. 540-547
Vision-Based Cooking Assistance System for Visually Impaired People
- 18 December 2019
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 33 (12) , 5739-5746
Estimation of WorldSID thorax kinematics using multiple 3-axis accelerometers
- 18 December 2019
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 33 (12) , 5739-5746
Estimation of WorldSID thorax kinematics using multiple 3-axis accelerometers
- 15 September 2016
- Published by Springer Nature in Artificial Intelligence Review
- Vol. 48 (4) , 529-555
A computational model of design critiquing
- 15 September 2016
- Published by Springer Nature in Artificial Intelligence Review
- Vol. 48 (4) , 529-555
A computational model of design critiquing