Rashid Mia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Rashid Mia has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Karl J. Wallace
Department of Chemistry and Biochemistry, School of Mathematics and Natural Sciences, The University of Southern Mississippi, 118 College Drive, Hattiesburg, Mississippi 39406, USA
6 shared publications - Peter J. Cragg
School of Applied Sciences, University of Brighton, Brighton, UK
3 shared publications - Amer Dawoud
School of Computing Sciences and Computer Engineering, The University of Southern Mississippi, Hattiesburg, MS 39406, USA
2 shared publications - Jesy Alka Motchaalangaram
Department of Chemistry and Biochemistry, School of Mathematics and Natural Sciences, The University of Southern Mississippi, Hattiesburg, MS 39406, USA
2 shared publications - Wujian Miao
Department of Chemistry and Biochemistry
2 shared publications - Aaron B. Davis
Department of Chemical and Biomolecular Engineering
1 shared publication
Latest Publications
- Open Access
Toward Remote Detection of Chemical Warfare Simulants Using a Miniature Potentiostat
A miniaturized electrochemical sensor was developed for the remote detection of chemical warfare agent (CWA) simulants. To facilitate drone-based remote sensing, this present study focuses on advancing the miniaturized and compact electrochemical sensor for monitoring two CWA simulants, diisopropyl fluorophosphate (DFP) and O,S-diethylmethylphosphonothioate (O,S-DEMPT). The differential pulse voltammetry (DPV) signal was processed, and the DPV signature features were extracted on the basis of the redox properties associated with the absence and the presence of DFP and O,S-DEMPT. Upon the addition of 0.10 equivalence of DFP or O,S-DEMPT, a shift in potential (E) of ~0.13 V was recorded. The limit of detection (LOD) was calculated to be 0.25 µM (0.046 ppm) and 0.10 µM (0.017 ppm) for DFP and O,S-DEMPT, respectively. These results were validated using a portable Palmsens Emstat HR potentiostat, which corroborated the results obtained using a lab benchtop potentiostat. Additionally, Boolean logic (“AND” operation) was implemented for future drone technology deployment. This advancement enables the fabrication of a networked device capable of autonomously executing tasks without constant oversight.
Open AccessToward Remote Detection of Chemical Warfare Simulants Using a Miniature Potentiostat
A miniaturized electrochemical sensor was developed for the remote detection of chemical warfare agent (CWA) simulants. To facilitate drone-based remote sensing, this present study focuses on advancing the miniaturized and compact electrochemical sensor for monitoring two CWA simulants, diisopropyl fluorophosphate (DFP) and O,S-diethylmethylphosphonothioate (O,S-DEMPT). The differential pulse voltammetry (DPV) signal was processed, and the DPV signature features were extracted on the basis of the redox properties associated with the absence and the presence of DFP and O,S-DEMPT. Upon the addition of 0.10 equivalence of DFP or O,S-DEMPT, a shift in potential (E) of ~0.13 V was recorded. The limit of detection (LOD) was calculated to be 0.25 µM (0.046 ppm) and 0.10 µM (0.017 ppm) for DFP and O,S-DEMPT, respectively. These results were validated using a portable Palmsens Emstat HR potentiostat, which corroborated the results obtained using a lab benchtop potentiostat. Additionally, Boolean logic (“AND” operation) was implemented for future drone technology deployment. This advancement enables the fabrication of a networked device capable of autonomously executing tasks without constant oversight.
- 13 November 2023
- Published by Royal Society of Chemistry (RSC) in Organic & Biomolecular Chemistry
- Vol. 21 (47) , 9379-9391
A molecular chemodosimeter to probe “closed shell” ions in kidney cells
Two chemodosimeters have been synthesized to detect closed-shell metal ions (Zn2+ and Cd2+) in HEK 293 cells.
- 13 November 2023
- Published by Royal Society of Chemistry (RSC) in Organic & Biomolecular Chemistry
- Vol. 21 (47) , 9379-9391
A molecular chemodosimeter to probe “closed shell” ions in kidney cells
Two chemodosimeters have been synthesized to detect closed-shell metal ions (Zn2+ and Cd2+) in HEK 293 cells.
- Open Access
- 10 August 2023
- Published by MDPI AG in Preprints.org
Towards Sensitive Electrochemical Sensing of Chemical Warfare Agent mimics with Remote based Drone Technology
The present work focuses on developing miniaturized, light weight electrochemical sensors for detection of chemical warfare agents (CWAs) like sarin and tabun simulants, i.e., diisopropyl fluorophosphate (DFP), and O,S-diethyl methyl phosphonothioate (O,S-DEMPT). Differential pulse voltammetry (DPV) was employed to examine the redox properties of capturing molecular probe CE2 with the nerve agent stimulants. Coupling of a portable potentiostat with the drone technology could allow on-situ and remote detection of analytes such CWAs to be realized, which can be crucially important to the national and global securities.
- 10 August 2023
- Published by MDPI AG in Preprints.org
Open AccessTowards Sensitive Electrochemical Sensing of Chemical Warfare Agent mimics with Remote based Drone Technology
The present work focuses on developing miniaturized, light weight electrochemical sensors for detection of chemical warfare agents (CWAs) like sarin and tabun simulants, i.e., diisopropyl fluorophosphate (DFP), and O,S-diethyl methyl phosphonothioate (O,S-DEMPT). Differential pulse voltammetry (DPV) was employed to examine the redox properties of capturing molecular probe CE2 with the nerve agent stimulants. Coupling of a portable potentiostat with the drone technology could allow on-situ and remote detection of analytes such CWAs to be realized, which can be crucially important to the national and global securities.
- 24 October 2022
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 46 (44) , 21278-21286
Killing two birds with one stone: phosphorylation by a tabun mimic and subsequent capture of cyanide using a single fluorescent chemodosimeter
In the presence of the tabun mimic diethylcyanophosphonate (DECP), a fluorescent bifunctional coumarin–enamine chemodosimeter is first phosphorylated and subsequently attacked by the released cyanide ions.
- 24 October 2022
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 46 (44) , 21278-21286
Killing two birds with one stone: phosphorylation by a tabun mimic and subsequent capture of cyanide using a single fluorescent chemodosimeter
In the presence of the tabun mimic diethylcyanophosphonate (DECP), a fluorescent bifunctional coumarin–enamine chemodosimeter is first phosphorylated and subsequently attacked by the released cyanide ions.
- 1 September 2021
- Published by American Chemical Society (ACS) in Inorganic Chemistry
- Vol. 60 (18) , 14238-14252
Structural Features of a Family of Coumarin–Enamine Fluorescent Chemodosimeters for Ion Pairs
A family of coumarin–enamine chemodosimeters is evaluated for their potential use as fluorescent molecular probes for multiple analytes [cadmium(II), cobalt(II), copper(II), iron(II), nickel(II), lead(II), and zinc(II)], as their chloride and acetate salts. These fluorophores displayed excellent optical spectroscopic modulation when exposed to ion pairs with different Lewis acidic and basic properties in dimethyl sulfoxide (DMSO). The chemodosimeters were designed to undergo excited-state intramolecular proton transfer (ESIPT), which leads to significant Stokes shifts (ca. 225 nm) and lower-energy fluorescence emission (ca. 575 nm). A more basic anion, e.g., acetate, inhibited the ESIPT mechanism by deprotonation of the enol, producing a binding pocket (N^O– chelate) that can coordinate to an appropriate metal ion. Coordination of the metal ions enhances the fluorescent intensity via the chelation-enhanced fluorescence emission mechanism. Subjecting the spectroscopic data to linear discriminant analysis provided insights into the source of these systems’ markedly different behavior toward ion pairs, despite the subtle structural differences in the organic framework. These compounds are examples of versatile, low-molecular-weight, dual-channel fluorescent sensors for ion-pair recognition. This study paves the way for using these probes as practical components of a sensing array for different metal ions and their respective anions.
- 1 September 2021
- Published by American Chemical Society (ACS) in Inorganic Chemistry
- Vol. 60 (18) , 14238-14252
Structural Features of a Family of Coumarin–Enamine Fluorescent Chemodosimeters for Ion Pairs
A family of coumarin–enamine chemodosimeters is evaluated for their potential use as fluorescent molecular probes for multiple analytes [cadmium(II), cobalt(II), copper(II), iron(II), nickel(II), lead(II), and zinc(II)], as their chloride and acetate salts. These fluorophores displayed excellent optical spectroscopic modulation when exposed to ion pairs with different Lewis acidic and basic properties in dimethyl sulfoxide (DMSO). The chemodosimeters were designed to undergo excited-state intramolecular proton transfer (ESIPT), which leads to significant Stokes shifts (ca. 225 nm) and lower-energy fluorescence emission (ca. 575 nm). A more basic anion, e.g., acetate, inhibited the ESIPT mechanism by deprotonation of the enol, producing a binding pocket (N^O– chelate) that can coordinate to an appropriate metal ion. Coordination of the metal ions enhances the fluorescent intensity via the chelation-enhanced fluorescence emission mechanism. Subjecting the spectroscopic data to linear discriminant analysis provided insights into the source of these systems’ markedly different behavior toward ion pairs, despite the subtle structural differences in the organic framework. These compounds are examples of versatile, low-molecular-weight, dual-channel fluorescent sensors for ion-pair recognition. This study paves the way for using these probes as practical components of a sensing array for different metal ions and their respective anions.
- 1 July 2021
- Published by Elsevier in Journal of Luminescence
- Vol. 235
Low Molecular Weight Fluorescent probes for the detection of organophosphates
- 1 July 2021
- Published by Elsevier in Journal of Luminescence
- Vol. 235
Low Molecular Weight Fluorescent probes for the detection of organophosphates