Zhong Zheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhong Zheng has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Cong Wang
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
1 shared publication - Dongjunming Yang
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing 102206, China
1 shared publication - Geng Chen
North China Electric Power University
1 shared publication - Guangkai Cui
Key Laboratory of High Voltage & EMC, North China Electric Power University, Beijing 102206, People’s Republic of China
1 shared publication - Hua Jin
School of Control and Computer Engineering, North China Electric Power University, Beijing, China
1 shared publication - Shuai Wang
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
1 shared publication
Latest Publications
- 29 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (6) , 3110-3119
Method Based on Stacking-Attention to Find Decomposition Indicators of Discharge Mechanism in C4F7N-CO2-O2 Gas
The correlation between the decomposition products and discharge faults in the electrical equipment with the environmentally friendly insulating gas mixture C 4 F 7 N/CO 2 /O 2 remains inadequately revealed. and the corresponding characterization methods also need to be determined. In this paper, a feature fusion algorithm based on the stacking-attention mechanism is proposed. The ratios of decomposition products from C 4 F 7 N/CO 2 /O 2 mixtures in various proportions under different discharge conditions are utilized as the dataset. Multiple feature extraction algorithms are employed as base learners to derive feature subsets from diverse dimensions. Subsequently, these feature subsets are fused using the attention mechanism as the meta-learner, and the contribution of each feature value is determined, thereby identifying the optimal feature subset. Experimental results demonstrate that the optimal feature values extracted by this method, when applied to classification algorithms such as Support Vector Machines (SVM) and Artificial Neural Networks (ANN), effectively distinguish between defects including corona discharge, spark discharge, and suspended discharge in environmentally friendly gas-insulated equipment. Based on the decomposition characteristics, the ratios of CO/(C 3 F 6 +CF 4 ) and CF 4 /C 3 F 8 are proposed as diagnostic indicators for identifying discharge faults in engineering applications of C 4 F 7 N/CO 2 /O 2 gas-insulated equipment. The research results of this paper provide both theoretical and technical support for the operation and maintenance of gas-insulated electrical equipment.
- 29 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (6) , 3110-3119
Method Based on Stacking-Attention to Find Decomposition Indicators of Discharge Mechanism in C4F7N-CO2-O2 Gas
The correlation between the decomposition products and discharge faults in the electrical equipment with the environmentally friendly insulating gas mixture C 4 F 7 N/CO 2 /O 2 remains inadequately revealed. and the corresponding characterization methods also need to be determined. In this paper, a feature fusion algorithm based on the stacking-attention mechanism is proposed. The ratios of decomposition products from C 4 F 7 N/CO 2 /O 2 mixtures in various proportions under different discharge conditions are utilized as the dataset. Multiple feature extraction algorithms are employed as base learners to derive feature subsets from diverse dimensions. Subsequently, these feature subsets are fused using the attention mechanism as the meta-learner, and the contribution of each feature value is determined, thereby identifying the optimal feature subset. Experimental results demonstrate that the optimal feature values extracted by this method, when applied to classification algorithms such as Support Vector Machines (SVM) and Artificial Neural Networks (ANN), effectively distinguish between defects including corona discharge, spark discharge, and suspended discharge in environmentally friendly gas-insulated equipment. Based on the decomposition characteristics, the ratios of CO/(C 3 F 6 +CF 4 ) and CF 4 /C 3 F 8 are proposed as diagnostic indicators for identifying discharge faults in engineering applications of C 4 F 7 N/CO 2 /O 2 gas-insulated equipment. The research results of this paper provide both theoretical and technical support for the operation and maintenance of gas-insulated electrical equipment.
- Open Access
Research on the Influence of Battery Cell Static Parameters on the Capacity of Different Topology Battery Packs
The parameter inconsistency of the battery cells and the series-parallel connection mode are closely related to the battery pack capacity. Studying the degree of influence of battery pack capacity by battery cell parameters is of great significance to the series-parallel design of battery packs. This paper establishes battery cell models and battery pack models with different topologies. In the MATLAB/Simulink environment, simulation studies were conducted to study the influence of the battery pack capacity by the monomer parameters as the number of cells in series and parallel in the topology changes. Then, from a statistical point of view, the simulation results were analyzed in principle. Finally, a small-scale battery pack experimental platform was built in the laboratory environment to verify the correctness of the simulation conclusions and theoretical analysis.
Open AccessResearch on the Influence of Battery Cell Static Parameters on the Capacity of Different Topology Battery Packs
The parameter inconsistency of the battery cells and the series-parallel connection mode are closely related to the battery pack capacity. Studying the degree of influence of battery pack capacity by battery cell parameters is of great significance to the series-parallel design of battery packs. This paper establishes battery cell models and battery pack models with different topologies. In the MATLAB/Simulink environment, simulation studies were conducted to study the influence of the battery pack capacity by the monomer parameters as the number of cells in series and parallel in the topology changes. Then, from a statistical point of view, the simulation results were analyzed in principle. Finally, a small-scale battery pack experimental platform was built in the laboratory environment to verify the correctness of the simulation conclusions and theoretical analysis.