Xiaoping Xie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xiaoping Xie has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Xiaohua Hou
Division of Gastroenterology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology
2 shared publications Gangping Li
Huazhong Univ Sci & Technol, Tongji Med Coll, Union Hosp, Div Gastroenterol, Wuhan 430022, Peoples R China
1 shared publicationJ Song
Division of Gastroenterology, Union Hospital of Tongji Medical College, Huazhong University of Science and Technology, 1277 Jiefang Road, Wuhan 430022, China
1 shared publicationL Zhang
Division of Gastroenterology, Union Hospital of Tongji Medical College, Huazhong University of Science and Technology, 1277 Jiefang Road, Wuhan 430022, China
1 shared publicationT Bai
Division of Gastroenterology, Union Hospital of Tongji Medical College, Huazhong University of Science and Technology, 1277 Jiefang Road, Wuhan 430022, China
1 shared publicationTao Bai
Huazhong Univ Sci & Technol, Tongji Med Coll, Union Hosp, Div Gastroenterol, Wuhan 430022, Peoples R China
1 shared publication
Latest Publications
- Open Access
- 1 March 2021
- Published by AME Publishing Company in Annals of Translational Medicine
- Vol. 9 (5) , 411
Feasibility of a second-generation colon capsule in visualization of the upper gastrointestinal tract
Background: Capsule endoscopy for visualization of the entire gastrointestinal tract is a challenge. A second-generation colon capsule endoscopy system (CCE-2) performed well in the colon and small intestine, but its utility in the upper gastrointestinal duct is not clear. We evaluated the use of the CCE-2 in the visualization of the upper gastrointestinal tract. Methods: We performed a retrospective study and further evaluated CCE-2 images using the typical landmarks of esophagus and stomach. The two imagers located at each end of the CCE-2 system were defined as imager1 (green) and imager2 (yellow). Two endoscopists read the images, and they were blinded to the other reader’s results. All of the images from the two imagers were separately reviewed. Results: Images from 127 subjects were analyzed. This study demonstrated the comprehensive visualization of 71.7% of esophageal landmarks and 89.8% of gastric landmarks using the CCE-2. The two CCE-2 imagers were not identical, and the lighter imager (imager2, yellow) was superior to the heavier imager (imager1, green) (78% vs. 33.1%) in the stomach. Compared with the use of one imager, the use of two imagers was superior (two-imager vs. imager1, 89.8% vs. 33.1%; two-imager vs. imager2, 89.8% vs. 78%) in the stomach. Two-imager combination analysis detected a total of 160 positive findings. In contrast, single-imager analysis with imager1 and imager2 detected 133 and 137 findings, respectively. Two-imager combination analysis provided 20.3% and 16.8% more findings than imager1 and imager2, respectively. The two imagers complemented each other to detect more lesions. Conclusions: The CCE-2 system is feasible for use in the upper gastrointestinal tract and may be considered an optional tool for upper gastrointestinal imaging. This system may represent a good choice for complete gastrointestinal duct screening. Compared with the use of one imager, the two-imager combination provided improved upper gastrointestinal tract mucosal visualization.
- 1 March 2021
- Published by AME Publishing Company in Annals of Translational Medicine
- Vol. 9 (5) , 411
Open AccessFeasibility of a second-generation colon capsule in visualization of the upper gastrointestinal tract
Background: Capsule endoscopy for visualization of the entire gastrointestinal tract is a challenge. A second-generation colon capsule endoscopy system (CCE-2) performed well in the colon and small intestine, but its utility in the upper gastrointestinal duct is not clear. We evaluated the use of the CCE-2 in the visualization of the upper gastrointestinal tract. Methods: We performed a retrospective study and further evaluated CCE-2 images using the typical landmarks of esophagus and stomach. The two imagers located at each end of the CCE-2 system were defined as imager1 (green) and imager2 (yellow). Two endoscopists read the images, and they were blinded to the other reader’s results. All of the images from the two imagers were separately reviewed. Results: Images from 127 subjects were analyzed. This study demonstrated the comprehensive visualization of 71.7% of esophageal landmarks and 89.8% of gastric landmarks using the CCE-2. The two CCE-2 imagers were not identical, and the lighter imager (imager2, yellow) was superior to the heavier imager (imager1, green) (78% vs. 33.1%) in the stomach. Compared with the use of one imager, the use of two imagers was superior (two-imager vs. imager1, 89.8% vs. 33.1%; two-imager vs. imager2, 89.8% vs. 78%) in the stomach. Two-imager combination analysis detected a total of 160 positive findings. In contrast, single-imager analysis with imager1 and imager2 detected 133 and 137 findings, respectively. Two-imager combination analysis provided 20.3% and 16.8% more findings than imager1 and imager2, respectively. The two imagers complemented each other to detect more lesions. Conclusions: The CCE-2 system is feasible for use in the upper gastrointestinal tract and may be considered an optional tool for upper gastrointestinal imaging. This system may represent a good choice for complete gastrointestinal duct screening. Compared with the use of one imager, the two-imager combination provided improved upper gastrointestinal tract mucosal visualization.
- 1 February 2020
- Published by Oxford University Press (OUP) in Diseases of the Esophagus
- Vol. 33 (4)
Better view by detachable string magnetically controlled capsule endoscopy for esophageal observation: a retrospective comparative study
Magnetically controlled capsule endoscopy (MCE) system has been used to screen gastric lesions. However, the visualization performance of MCE in the esophagus has not been investigated systematically. String method improved the ability of capsule endoscopy (CE) for esophageal observing; however, the string attachment is complicated and cannot be detached with the CE inside the esophagus. We used a modified string, called detachable string attached to MCE. The aim of the study was to compare the observation performance of MCE with and without the detachable string. A total of 238 participants with upper gastrointestinal symptoms and a healthy check who refused esophagogastroduodenoscopy examination were retrospectively divided into the detachable string MCE group and the MCE alone group from June 2016 to May 2018. A suction cap with a thin, hollow string was attached to the MCE system in the detachable string group. Circumferential visualization of the esophagus including the upper, middle, and lower esophagus and Z-line, and esophageal focal lesion, as well as the recording time, safety and tolerability of the procedure, were assessed. The circumferential visualization of the upper, middle, and lower esophagus and Z-line was more efficient in the detachable string MCE group than in the MCE alone group (P < 0.001). In all, 31 esophageal lesions were detected in the detachable string MCE group, which was more than that in the MCE alone group (10, P < 0.001). The mean recording time was 305 seconds in the string MCE group, which was longer than that in the MCE alone group (48.5 seconds, P < 0.001). In seven participants (6.1%) in the detachable string MCE group, the capsule could not be separated from the string. Detachable string MCE showed better performance in terms of observation of the esophagus. Detachable string MCE can be used to screen for esophageal diseases as an alternative method in the future.
- 1 February 2020
- Published by Oxford University Press (OUP) in Diseases of the Esophagus
- Vol. 33 (4)
Better view by detachable string magnetically controlled capsule endoscopy for esophageal observation: a retrospective comparative study
Magnetically controlled capsule endoscopy (MCE) system has been used to screen gastric lesions. However, the visualization performance of MCE in the esophagus has not been investigated systematically. String method improved the ability of capsule endoscopy (CE) for esophageal observing; however, the string attachment is complicated and cannot be detached with the CE inside the esophagus. We used a modified string, called detachable string attached to MCE. The aim of the study was to compare the observation performance of MCE with and without the detachable string. A total of 238 participants with upper gastrointestinal symptoms and a healthy check who refused esophagogastroduodenoscopy examination were retrospectively divided into the detachable string MCE group and the MCE alone group from June 2016 to May 2018. A suction cap with a thin, hollow string was attached to the MCE system in the detachable string group. Circumferential visualization of the esophagus including the upper, middle, and lower esophagus and Z-line, and esophageal focal lesion, as well as the recording time, safety and tolerability of the procedure, were assessed. The circumferential visualization of the upper, middle, and lower esophagus and Z-line was more efficient in the detachable string MCE group than in the MCE alone group (P < 0.001). In all, 31 esophageal lesions were detected in the detachable string MCE group, which was more than that in the MCE alone group (10, P < 0.001). The mean recording time was 305 seconds in the string MCE group, which was longer than that in the MCE alone group (48.5 seconds, P < 0.001). In seven participants (6.1%) in the detachable string MCE group, the capsule could not be separated from the string. Detachable string MCE showed better performance in terms of observation of the esophagus. Detachable string MCE can be used to screen for esophageal diseases as an alternative method in the future.