Christina M. Webber
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Christina M. Webber has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Kenton R. Kaufman
Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
5 shared publications - Alexander Y. Shin
Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, United States
4 shared publications - Anders J. Asp
Mayo Clinic
2 shared publications - Ephraim I. Ben-Abraham
Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, US
2 shared publications - Gabriel Martínez-Gálvez
Department of Physiology and Biomedical Engineering, Mayo Clinic , Rochester, Minnesota
2 shared publications - J. Luis Lujan
Department of Neurologic Surgery, Mayo Clinic, Rochester, MN 55901, USA
2 shared publications
Latest Publications
- Top Cited PapersOpen Access
- 26 January 2024
- Published by Springer Nature in npj Digital Medicine
- Vol. 7 (1) , 1-4
Transparency of artificial intelligence/machine learning-enabled medical devices
- 26 January 2024
- Published by Springer Nature in npj Digital Medicine
- Vol. 7 (1) , 1-4
Top Cited PapersOpen AccessTransparency of artificial intelligence/machine learning-enabled medical devices
- Open Access
- 9 June 2023
- Published by Springer Nature in Therapeutic Innovation & Regulatory Science
- Vol. 57 (5) , 952-956
Integrating Patient-Generated Health Data Throughout the Total Product Life Cycle of Medical Devices
Nearly ubiquitous use of personal electronics, wearable sensors, and other types of digital health technologies, along with wireless connectivity, makes the capture of health data directly from an individual easier, enabling the use of patient-generated health data (PGHD) as a potential bridge between a patient’s home and the healthcare system. This type of real-world data may be a completely new type of information, or it may be a more frequent collection of traditional information over longer time periods to form a longitudinal view of a patient’s health status that can inform decision-making in clinical, medical product regulatory, and coverage and reimbursement settings. The U.S. Food and Drug Administration’s Center for Devices and Radiological Health (CDRH) has been exploring and advancing the collection and use of PGHD since 2016, hosting a public meeting on the topic in May 2021. This manuscript presents highlights from various discussions at this meeting including those on the importance of stakeholder engagement, characteristics of high data quality, and PGHD in practice in patient-driven registries, as well as a look forward to some of the opportunities in the field.
- 9 June 2023
- Published by Springer Nature in Therapeutic Innovation & Regulatory Science
- Vol. 57 (5) , 952-956
Open AccessIntegrating Patient-Generated Health Data Throughout the Total Product Life Cycle of Medical Devices
Nearly ubiquitous use of personal electronics, wearable sensors, and other types of digital health technologies, along with wireless connectivity, makes the capture of health data directly from an individual easier, enabling the use of patient-generated health data (PGHD) as a potential bridge between a patient’s home and the healthcare system. This type of real-world data may be a completely new type of information, or it may be a more frequent collection of traditional information over longer time periods to form a longitudinal view of a patient’s health status that can inform decision-making in clinical, medical product regulatory, and coverage and reimbursement settings. The U.S. Food and Drug Administration’s Center for Devices and Radiological Health (CDRH) has been exploring and advancing the collection and use of PGHD since 2016, hosting a public meeting on the topic in May 2021. This manuscript presents highlights from various discussions at this meeting including those on the importance of stakeholder engagement, characteristics of high data quality, and PGHD in practice in patient-driven registries, as well as a look forward to some of the opportunities in the field.
- 1 February 2022
- Published by Elsevier in Journal of Electromyography and Kinesiology
- Vol. 62, 102312
Upper extremity function in the free living environment of adults with traumatic brachial plexus injuries
- 1 February 2022
- Published by Elsevier in Journal of Electromyography and Kinesiology
- Vol. 62, 102312
Upper extremity function in the free living environment of adults with traumatic brachial plexus injuries
- 12 November 2021
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 45 (6) , 526-531
Application of a myoelectric elbow flexion assist orthosis in adult traumatic brachial plexus injury: patient perspectives
Background: Individuals with brachial plexus injuries (BPIs) can be prescribed assistive devices, including myoelectric elbow orthoses (MEOs), for rehabilitation or functional use after failed treatment for elbow flexion restoration. Although recent case studies indicate potential for clinical improvements after using an MEO after BPI, the patients' perspectives on such use are still unknown. Objective: To explore patient perspectives on the use of an MEO after surgical treatment for a traumatic BPI. Study design: Qualitative using both a focus group and semistructured interviews. Methods: Patients with BPI that used an MEO were recruited. Five patients participated in an in-person focus group, whereas three patients participated in individual phone interviews. Themes that emerged from the focus group were compared against those that emerged from the personal interviews. Results: Feedback was grouped into three themes: device usage, hardware performance, and device design. Within each theme, positive elements, areas for improvement, and additional considerations emerged. Patients indicated a positive attitude toward using an MEO as a rehabilitation tool. They desired a streamlined, stronger device to support them and assist during activities of daily living. Conclusions: For patients with BPI, a well-designed MEO that meets their needs could assist with rehabilitation and increase independence in daily activities. Continued patient engagement in the evaluation and development of both medical devices and treatment plans offers the best opportunity for improved outcomes that are important to the patient.
- 12 November 2021
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 45 (6) , 526-531
Application of a myoelectric elbow flexion assist orthosis in adult traumatic brachial plexus injury: patient perspectives
Background: Individuals with brachial plexus injuries (BPIs) can be prescribed assistive devices, including myoelectric elbow orthoses (MEOs), for rehabilitation or functional use after failed treatment for elbow flexion restoration. Although recent case studies indicate potential for clinical improvements after using an MEO after BPI, the patients' perspectives on such use are still unknown. Objective: To explore patient perspectives on the use of an MEO after surgical treatment for a traumatic BPI. Study design: Qualitative using both a focus group and semistructured interviews. Methods: Patients with BPI that used an MEO were recruited. Five patients participated in an in-person focus group, whereas three patients participated in individual phone interviews. Themes that emerged from the focus group were compared against those that emerged from the personal interviews. Results: Feedback was grouped into three themes: device usage, hardware performance, and device design. Within each theme, positive elements, areas for improvement, and additional considerations emerged. Patients indicated a positive attitude toward using an MEO as a rehabilitation tool. They desired a streamlined, stronger device to support them and assist during activities of daily living. Conclusions: For patients with BPI, a well-designed MEO that meets their needs could assist with rehabilitation and increase independence in daily activities. Continued patient engagement in the evaluation and development of both medical devices and treatment plans offers the best opportunity for improved outcomes that are important to the patient.
- 16 July 2020
- Published by Elsevier in Clinical Biomechanics
- Vol. 80, 105106
Effects of elbow immobilization on upper extremity activity
- 16 July 2020
- Published by Elsevier in Clinical Biomechanics
- Vol. 80, 105106
Effects of elbow immobilization on upper extremity activity
- Open Access
- 13 April 2020
- Published by Ubiquity Press, Ltd. in Annals of Global Health
- Vol. 86 (1) , 39
Developing Strategies for Sustainable Medical Equipment Maintenance in Under-Resourced Settings
Engineering technology plays a pivotal role in the delivery of health care in under-resourced countries by providing an infrastructure to improve patient outcomes. However, sustainability of these technologies is difficult in these settings oftentimes due to limited resources or training. The framework presented in this editorial focuses on establishing medical and laboratory equipment sustainability in developing countries and is comprised of four steps: 1) establishing reliable in-country relationships with stakeholders, 2) identifying needs for sustainable solutions locally, 3) exploring potential solutions and assessing their effort-to-impact ratios, and 4) working with strategic partners to implement solutions with clear performance metrics. By focusing on the sustainability of donated equipment instead of the equipment itself, this method presented distinguishes itself from other philanthropic endeavors in the field by seeking to establish preventive maintenance habits that can impact clinical outcomes of a community long term. Application of this methodology is reported in the Original Research Article "A Low-Cost Humidity Control System to Protect Microscopes in a Tropical Climate" by Asp et. al.
- 13 April 2020
- Published by Ubiquity Press, Ltd. in Annals of Global Health
- Vol. 86 (1) , 39
Open AccessDeveloping Strategies for Sustainable Medical Equipment Maintenance in Under-Resourced Settings
Engineering technology plays a pivotal role in the delivery of health care in under-resourced countries by providing an infrastructure to improve patient outcomes. However, sustainability of these technologies is difficult in these settings oftentimes due to limited resources or training. The framework presented in this editorial focuses on establishing medical and laboratory equipment sustainability in developing countries and is comprised of four steps: 1) establishing reliable in-country relationships with stakeholders, 2) identifying needs for sustainable solutions locally, 3) exploring potential solutions and assessing their effort-to-impact ratios, and 4) working with strategic partners to implement solutions with clear performance metrics. By focusing on the sustainability of donated equipment instead of the equipment itself, this method presented distinguishes itself from other philanthropic endeavors in the field by seeking to establish preventive maintenance habits that can impact clinical outcomes of a community long term. Application of this methodology is reported in the Original Research Article "A Low-Cost Humidity Control System to Protect Microscopes in a Tropical Climate" by Asp et. al.
- Open Access
- 13 February 2020
- Published by Ubiquity Press, Ltd. in Annals of Global Health
- Vol. 86 (1) , 16
A Low-Cost Humidity Control System to Protect Microscopes in a Tropical Climate
A clean and functional microscope is necessary for accurate diagnosis of infectious diseases. In tropical climates, high humidity levels and improper storage conditions allow for the accumulation of debris and fungus on the optical components of diagnostic equipment, such as microscopes. Our objective was to develop and implement a low-cost, sustainable, easy to manage, low-maintenance, passive humidity control chamber to both reduce debris accumulation and microbial growth onto the optical components of microscopes. Constructed from easily-sourced and locally available materials, the cost of each humidity control chamber is approximately $2.35 USD. Relative humidity levels were recorded every 30 minutes over a period of 10 weeks from two chambers deployed at the Belize Vector and Ecology Center and the University of Belize. The humidity control chamber deployed at the University of Belize maintained internal relative humidity at an average of 35.3% (SD = 4.2%) over 10 weeks, while the average external relative humidity was 86.4% (SD = 12.4%). The humidity control chamber deployed at the Belize Vector and Ecology Center effectively maintained internal relative humidity to an average of 54.5% (SD = 9.4%) over 10 weeks, while the average external relative humidity was 86.9% (SD = 12.9%). Control of relative humidity is paramount for the sustainability of medical equipment in tropical climates. The humidity control chambers reduced relative humidity to levels that were not conducive for fungal growth while reducing microscope contamination from external sources. This will likely extend the service life of the microscopes while taking advantage of low-cost, locally sourced components.
- 13 February 2020
- Published by Ubiquity Press, Ltd. in Annals of Global Health
- Vol. 86 (1) , 16
Open AccessA Low-Cost Humidity Control System to Protect Microscopes in a Tropical Climate
A clean and functional microscope is necessary for accurate diagnosis of infectious diseases. In tropical climates, high humidity levels and improper storage conditions allow for the accumulation of debris and fungus on the optical components of diagnostic equipment, such as microscopes. Our objective was to develop and implement a low-cost, sustainable, easy to manage, low-maintenance, passive humidity control chamber to both reduce debris accumulation and microbial growth onto the optical components of microscopes. Constructed from easily-sourced and locally available materials, the cost of each humidity control chamber is approximately $2.35 USD. Relative humidity levels were recorded every 30 minutes over a period of 10 weeks from two chambers deployed at the Belize Vector and Ecology Center and the University of Belize. The humidity control chamber deployed at the University of Belize maintained internal relative humidity at an average of 35.3% (SD = 4.2%) over 10 weeks, while the average external relative humidity was 86.4% (SD = 12.4%). The humidity control chamber deployed at the Belize Vector and Ecology Center effectively maintained internal relative humidity to an average of 54.5% (SD = 9.4%) over 10 weeks, while the average external relative humidity was 86.9% (SD = 12.9%). Control of relative humidity is paramount for the sustainability of medical equipment in tropical climates. The humidity control chambers reduced relative humidity to levels that were not conducive for fungal growth while reducing microscope contamination from external sources. This will likely extend the service life of the microscopes while taking advantage of low-cost, locally sourced components.
- 1 December 2019
- Published by Elsevier in Clinical Biomechanics
- Vol. 70, 209-216
Kinematic profiles during activities of daily living in adults with traumatic brachial plexus injuries
- 1 December 2019
- Published by Elsevier in Clinical Biomechanics
- Vol. 70, 209-216
Kinematic profiles during activities of daily living in adults with traumatic brachial plexus injuries
- 1 July 2019
- Published by Elsevier in The Journal of Hand Surgery
- Vol. 44 (7) , 600-605
Assessment of Upper Extremity Function
- 1 July 2019
- Published by Elsevier in The Journal of Hand Surgery
- Vol. 44 (7) , 600-605
Assessment of Upper Extremity Function
- 1 October 2017
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 41 (5) , 463-468
Instantaneous stiffness and hysteresis of dynamic elastic response prosthetic feet
Dynamic elastic response prosthetic feet are designed to mimic the functional characteristics of the native foot/ankle joint. Numerous designs of dynamic elastic response feet exist which make the prescription process difficult, especially because of the lack of empirical evidence describing the objective performance characteristics of the feet. To quantify the mechanical properties of available dynamic elastic response prosthetic feet, specifically the stiffness and hysteresis. Mechanical testing of dynamic elastic response prosthetic feet. Static Proof Testing in accordance with ISO 10328 was conducted on seven dynamic elastic response prosthetic feet. Load–displacement data were used to calculate the instantaneous stiffness in both the heel and forefoot regions, as well as hysteresis associated with each foot. Heel stiffness was greater than forefoot stiffness for all feet. The heel of the glass composite prosthetic foot was stiffer than the carbon fiber feet and it exhibited less hysteresis. Two different carbon fiber feet had the stiffest forefoot regions. Mechanical testing is a reproducible method that can be used to provide objective evidence about dynamic elastic response prosthetic foot performance and aid in the prescription process. The quantitative stiffness and hysteresis data from this study can be used by prosthetists to aid the prescription process and make it more objective.
- 1 October 2017
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 41 (5) , 463-468
Instantaneous stiffness and hysteresis of dynamic elastic response prosthetic feet
Dynamic elastic response prosthetic feet are designed to mimic the functional characteristics of the native foot/ankle joint. Numerous designs of dynamic elastic response feet exist which make the prescription process difficult, especially because of the lack of empirical evidence describing the objective performance characteristics of the feet. To quantify the mechanical properties of available dynamic elastic response prosthetic feet, specifically the stiffness and hysteresis. Mechanical testing of dynamic elastic response prosthetic feet. Static Proof Testing in accordance with ISO 10328 was conducted on seven dynamic elastic response prosthetic feet. Load–displacement data were used to calculate the instantaneous stiffness in both the heel and forefoot regions, as well as hysteresis associated with each foot. Heel stiffness was greater than forefoot stiffness for all feet. The heel of the glass composite prosthetic foot was stiffer than the carbon fiber feet and it exhibited less hysteresis. Two different carbon fiber feet had the stiffest forefoot regions. Mechanical testing is a reproducible method that can be used to provide objective evidence about dynamic elastic response prosthetic foot performance and aid in the prescription process. The quantitative stiffness and hysteresis data from this study can be used by prosthetists to aid the prescription process and make it more objective.