JHJulio S. Hasegawa

Julio S. Hasegawa

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Julio S. Hasegawa has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • No sex differences in performance and perceived fatigability during a self-paced endurance exercise performed under moderate hypoxia

    by Julio S. Hasegawa, Andre C. Silveira, Rafael A. Azevedo, Julio Cezar Schamne, Maria Urbana Pinto Brandão Rondon, Marcelo Papoti, Adriano Eduardo Lima-Silva, Michael S. Koehle, Romulo Bertuzzi

    In this study, we showed that females and males develop a similar hypoxia-induced impairment in endurance performance, perceived and performance fatigability during a 4-km cycling time trial. These novel findings indicate that females and males regulate their power output similarly during a 4-km cycling time trial under moderate hypoxia, likely to avoid prematurely exacerbating metabolic disturbances and thereby reaching comparable levels of performance fatigability by the end of the task.


  • Open Access

    Wearable near-infrared spectroscopy: reliability and sensitivity among different endurance cycling exercise intensities

    by J.S. Hasegawa, R.A. Azevedo, A.C. Silveira, A.E. Lima-Silva, R. Bertuzzi

    The present study investigated the reliability and sensitivity of a wearable near-infrared spectroscopy (wNIRS) device in moderate and heavy exercise intensity domains. On three separate days, eleven males performed an incremental test to exhaustion, and in the following visits, four submaximal constant-load bouts (i.e., test and retest) were performed in the moderate-intensity domain (100 and 130 W) and heavy-intensity domain (160 and 190 W). The local tissue oxygen saturation index (SmO2) and pulmonary oxygen uptake (V̇O2) were measured continuously. The absolute SmO2 and V̇O2 values and the change (Δ) from the 3rd to 6th min of exercise were calculated. There was good reliability for SmO2 measurements, as indicated by the high intraclass correlation coefficient analysis (ICC ≥0.84 for all) and low coefficient of variation between the two trials (CV ≤4.1% for all). Steady-state responses were observed for SmO2 and V̇O2 from the 3rd to the 6th min in the two moderate-intensity bouts (P>0.05), whereas SmO2 decreased and V̇O2 increased from the 3rd to the 6th min in the two heavy-intensity bouts (P2 measured with a wNIRS device is reliable and sensitive to track local metabolic changes provoked by slight increments in exercise intensity.


  • Open Access

    Footwear designed to enhance energy return improves running economy compared to a minimalist footwear: does it matter for running performance?

    by R.C. Dinato, R. Cruz, R.A. Azevedo, J.S. Hasegawa, R.G. Silva, A.P. Ribeiro, A.E. Lima-Silva, R. Bertuzzi

    The present study compared the effects of a footwear designed to enhance energy return (thermoplastic polyurethane, TPU) vs minimalist shoes on running economy (RE) and endurance performance. In this counterbalanced and crossover design study, 11 recreational male runners performed two submaximal constant-speed running tests and two 3-km time-trials with the two shoe models. Oxygen uptake was measured during submaximal constant-speed running tests in order to determine the RE at 12 km/h and oxygen cost of running (CTO2) at individual average speed sustained during the 3-km running time-trials wearing either of the two shoes. Our results revealed that RE was improved (2.4%) with TPU shoes compared with minimalist shoes (P=0.01). However, there was no significant difference for CTO2 (P=0.61) and running performance (P=0.52) comparing the TPU (710±60 s) and the minimalist (718±63 s) shoe models. These novel findings demonstrate that shoes with enhanced mechanical energy return (i.e. TPU) produced a lower energy cost of running at low (i.e., 12 km/h) but not at high speeds (i.e., average speed sustained during the 3-km running time-trial, ∼15 km/h), ultimately resulting in similar running performance compared to the minimalist shoe.