Julio S. Hasegawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Julio S. Hasegawa has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Adriano Eduardo Lima-Silva
Technological Federal University of Parana
3 shared publications - Rafael de Almeida Azevedo
Universidade de São Paulo
3 shared publications - Romulo Bertuzzi
University of São Paulo
3 shared publications - Andre C. Silveira
Endurance Performance Research Group (GEDAE‐USP), School of Physical Education and Sport University of São Paulo São Paulo São Paulo Brazil
2 shared publications - Ana Paula Ribeiro
Biomechanics and Musculoskeletal Rehabilitation Laboratory, Health Science Post-Graduate Department, School of Medicine, University Santo Amaro, São Paulo 04829-300, Brazil
1 shared publication - Julio Cezar Schamne
Federal university of technology parana
1 shared publication
Latest Publications
- 1 March 2025
- Published by American Physiological Society in American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
- Vol. 328 (3) , R352-R363
No sex differences in performance and perceived fatigability during a self-paced endurance exercise performed under moderate hypoxia
In this study, we showed that females and males develop a similar hypoxia-induced impairment in endurance performance, perceived and performance fatigability during a 4-km cycling time trial. These novel findings indicate that females and males regulate their power output similarly during a 4-km cycling time trial under moderate hypoxia, likely to avoid prematurely exacerbating metabolic disturbances and thereby reaching comparable levels of performance fatigability by the end of the task.
- 1 March 2025
- Published by American Physiological Society in American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
- Vol. 328 (3) , R352-R363
No sex differences in performance and perceived fatigability during a self-paced endurance exercise performed under moderate hypoxia
In this study, we showed that females and males develop a similar hypoxia-induced impairment in endurance performance, perceived and performance fatigability during a 4-km cycling time trial. These novel findings indicate that females and males regulate their power output similarly during a 4-km cycling time trial under moderate hypoxia, likely to avoid prematurely exacerbating metabolic disturbances and thereby reaching comparable levels of performance fatigability by the end of the task.
- Open Access
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Brazilian Journal of Medical and Biological Research
- Vol. 57, e13102
Wearable near-infrared spectroscopy: reliability and sensitivity among different endurance cycling exercise intensities
The present study investigated the reliability and sensitivity of a wearable near-infrared spectroscopy (wNIRS) device in moderate and heavy exercise intensity domains. On three separate days, eleven males performed an incremental test to exhaustion, and in the following visits, four submaximal constant-load bouts (i.e., test and retest) were performed in the moderate-intensity domain (100 and 130 W) and heavy-intensity domain (160 and 190 W). The local tissue oxygen saturation index (SmO2) and pulmonary oxygen uptake (V̇O2) were measured continuously. The absolute SmO2 and V̇O2 values and the change (Δ) from the 3rd to 6th min of exercise were calculated. There was good reliability for SmO2 measurements, as indicated by the high intraclass correlation coefficient analysis (ICC ≥0.84 for all) and low coefficient of variation between the two trials (CV ≤4.1% for all). Steady-state responses were observed for SmO2 and V̇O2 from the 3rd to the 6th min in the two moderate-intensity bouts (P>0.05), whereas SmO2 decreased and V̇O2 increased from the 3rd to the 6th min in the two heavy-intensity bouts (P2 measured with a wNIRS device is reliable and sensitive to track local metabolic changes provoked by slight increments in exercise intensity.
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Brazilian Journal of Medical and Biological Research
- Vol. 57, e13102
Open AccessWearable near-infrared spectroscopy: reliability and sensitivity among different endurance cycling exercise intensities
The present study investigated the reliability and sensitivity of a wearable near-infrared spectroscopy (wNIRS) device in moderate and heavy exercise intensity domains. On three separate days, eleven males performed an incremental test to exhaustion, and in the following visits, four submaximal constant-load bouts (i.e., test and retest) were performed in the moderate-intensity domain (100 and 130 W) and heavy-intensity domain (160 and 190 W). The local tissue oxygen saturation index (SmO2) and pulmonary oxygen uptake (V̇O2) were measured continuously. The absolute SmO2 and V̇O2 values and the change (Δ) from the 3rd to 6th min of exercise were calculated. There was good reliability for SmO2 measurements, as indicated by the high intraclass correlation coefficient analysis (ICC ≥0.84 for all) and low coefficient of variation between the two trials (CV ≤4.1% for all). Steady-state responses were observed for SmO2 and V̇O2 from the 3rd to the 6th min in the two moderate-intensity bouts (P>0.05), whereas SmO2 decreased and V̇O2 increased from the 3rd to the 6th min in the two heavy-intensity bouts (P2 measured with a wNIRS device is reliable and sensitive to track local metabolic changes provoked by slight increments in exercise intensity.
- Open Access
- 1 January 2021
- Published by FapUNIFESP (SciELO) in Brazilian Journal of Medical and Biological Research
- Vol. 54 (5) , e10693
Footwear designed to enhance energy return improves running economy compared to a minimalist footwear: does it matter for running performance?
The present study compared the effects of a footwear designed to enhance energy return (thermoplastic polyurethane, TPU) vs minimalist shoes on running economy (RE) and endurance performance. In this counterbalanced and crossover design study, 11 recreational male runners performed two submaximal constant-speed running tests and two 3-km time-trials with the two shoe models. Oxygen uptake was measured during submaximal constant-speed running tests in order to determine the RE at 12 km/h and oxygen cost of running (CTO2) at individual average speed sustained during the 3-km running time-trials wearing either of the two shoes. Our results revealed that RE was improved (2.4%) with TPU shoes compared with minimalist shoes (P=0.01). However, there was no significant difference for CTO2 (P=0.61) and running performance (P=0.52) comparing the TPU (710±60 s) and the minimalist (718±63 s) shoe models. These novel findings demonstrate that shoes with enhanced mechanical energy return (i.e. TPU) produced a lower energy cost of running at low (i.e., 12 km/h) but not at high speeds (i.e., average speed sustained during the 3-km running time-trial, ∼15 km/h), ultimately resulting in similar running performance compared to the minimalist shoe.
- 1 January 2021
- Published by FapUNIFESP (SciELO) in Brazilian Journal of Medical and Biological Research
- Vol. 54 (5) , e10693
Open AccessFootwear designed to enhance energy return improves running economy compared to a minimalist footwear: does it matter for running performance?
The present study compared the effects of a footwear designed to enhance energy return (thermoplastic polyurethane, TPU) vs minimalist shoes on running economy (RE) and endurance performance. In this counterbalanced and crossover design study, 11 recreational male runners performed two submaximal constant-speed running tests and two 3-km time-trials with the two shoe models. Oxygen uptake was measured during submaximal constant-speed running tests in order to determine the RE at 12 km/h and oxygen cost of running (CTO2) at individual average speed sustained during the 3-km running time-trials wearing either of the two shoes. Our results revealed that RE was improved (2.4%) with TPU shoes compared with minimalist shoes (P=0.01). However, there was no significant difference for CTO2 (P=0.61) and running performance (P=0.52) comparing the TPU (710±60 s) and the minimalist (718±63 s) shoe models. These novel findings demonstrate that shoes with enhanced mechanical energy return (i.e. TPU) produced a lower energy cost of running at low (i.e., 12 km/h) but not at high speeds (i.e., average speed sustained during the 3-km running time-trial, ∼15 km/h), ultimately resulting in similar running performance compared to the minimalist shoe.