SPSimon Perraud

Simon Perraud

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Simon Perraud has a total of 46 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Test Results and Analysis of the MQYYM Magnet at 1.9 K in STAARQ, a New CEA Paris-Saclay Test Facility

    by S. Perraud, H. Allain, T. Boussuge, N. Commaux, R. Correia-Machado, P. De Antoni, H. Felice, A. Foussat, J.M. Gheller, Q. Guihard, et al.

    In the initial framework of HL-LHC project, a 90 mm Nb-Ti single aperture quadrupole short model with a gradient of 120 T/m at 1.9 K, has been designed, manufactured and firstly tested at 4.2 K as part of a collaboration between CERN and CEA. This magnet called MQYYM has been recently tested for the first time at 1.9 K and used as a reference magnet for the commissioning of the new CEA Paris-Saclay cryogenic test facility STAARQ (standing for test station for quadrupole accelerator magnets). This test station has been developed to test superconducting magnets up to 5 m-long at 1.9 K in a 1 bara helium bath with a lambda plate. Magnets can be powered up to 13 kA thanks to hybrid HTS current leads. It relies on digital and analog MSS (Magnet Safety System) for quench detection as well as on several types of instrumentation, from voltage taps and temperature sensors to strain gauges. This paper describes and analyzes the test results of MQYYM at 4.6 K and 1.9 K as part of the facility commissioning, with a special focus on mechanical measurements and protection results. In particular, it will conclude on the protection heater validation, necessary for the upcoming MQYY tests.


  • Test Results of the MQYYM: A 90 Mm NbTi Quadrupole Magnet Option for HL-LHC

    by D. Simon, S. Perraud, H. Felice, R. Godon, R. Correia Machado, J.-M. Gheller, D. Bouziat, V. Stepanov, A. Madur, M. Segreti, et al.

    For the HL-LHC project, a 90 mm NbTi cos(2θ) double aperture quadrupole magnet with an operating gradient of 120 T/m at 1.9 K has been designed as an option to replace the 70 mm aperture LHC quadrupole MQY. CEA in collaboration with CERN designed and manufactured a single aperture short model magnet with a magnetic length of 1.215 m at 1.9 K called MQYYM. The MQYYM cold test occurred at CEA at 4.2 K in a vertical cryogenic station. During the power test, the operating gradient at 1.9 K has been reached after two training quenches. All along the test, magnetic and mechanical measurements were done using respectively a rotating probe and strain gauges. This paper describes the performance of the MQYYM at 4.2 K and gives an analysis of the data acquired during the test, including training behavior, quench detection, protection and field quality measurements.


  • 3D Conceptual Design of R2D2, the Research Racetrack Dipole Demonstrator

    by E. Rochepault, V. Calvelli, M. Durante, H. Felice, P. Mallon, P. Manil, G. Minier, S. Perraud, J. C. Perez

    R2D2, the Research Racetrack Dipole Demonstrator, is a short model being developed within a collaboration between CEA Paris-Saclay and CERN. The goal of the program is to develop key technologies for future high field 16 T Nb3Sn magnets for particle colliders. In the particular case of block-coil designs, two different cable grades are wound in the same coil layer, in order to maximize the current density, therefore to minimize the size of the magnet and the use of superconductor. One of the most challenging technologies with this grading concept, is the connection between two cables grades. CEA Paris-Saclay has proposed a concept of external joints, for which the cable exits are guided outside of the coil to perform the connections between the cable grades. The R2D2 project is aimed at demonstrating this technology in a representative demonstrator magnet, while simplifying and reducing the risks when possible, as an intermediate step towards 16 T magnets. In particular, the magnet is composed of single-layer racetrack coils, mainly to reduce the use of conductor and simplify some fabrication steps. However, the complexity inherent to the external joints requires a special focus in the design of the coil ends. To do so, the design of the magnet has been performed using a combination of CAD (Computer Aided Design), magnetic and mechanical 3D FEM (Finite-Elements Models). This paper will explain the design choices leading to a safe operation of the magnet in terms of peak fields and peak stresses.


  • Assembly and Warm Magnetic Measurement of MQYYM: A 90 mm NbTi Quadrupole Magnet Option for HL-LHC

    by S. Perraud, D. Simon, H. Felice, M. Segreti, A. Madur, J.M. Rifflet, R. Correia Machado, R. Godon, D. Bouziat, S. Emami Naini, et al.

    In the framework of the HL-LHC project, a NbTi double aperture quadrupole magnet MQYY is being developed as an option to replace the LHC magnet MQY. This 90 mm double aperture cos-2θ quadrupole has an operating gradient of 120 T/m at 1.9 K. To demonstrate the validity of the design, a single aperture short model of 1.2 m called MQYYM has been developed. Designed by CEA and manufactured in collaboration with CERN, the MQYYM magnet is being prepared for cold test at CEA in a dedicated cryogenic station with LHe bath at 1 bar 4.2 K and 23 mbar 1.9 K. First, this paper will summarize the initial and as-built magnet designs based on the assembly at CERN. Second, updated mechanical measurements of collaring and axial pre-loading will be presented. Finally warm magnetic measurements performed at CERN during the assembly and at CEA during test preparation will be detailed.


  • Mechanical Analysis and Assembly of MQYYM: A 90 mm NbTi Quadrupole Magnet Option for HL-LHC

    by Damien Simon, Juan C. Perez, Arnaud Foussat, Salvador Ferradas Troitino, Sohrab Emami Naini, Michael Guinchard, Ezio Todesco, Helene Felice, Simon Perraud, Jean-Michel Rifflet, et al.

    For the HL-LHC project, a 90 mm double aperture NbTi quadrupole magnet is being developed as an option to replace the 70 mm aperture LHC quadrupole MQY. This cos2θ magnet has an operating gradient of 120 T/m at 1.9 K and a magnetic length of 3.67 m. A single aperture short model magnet with a magnetic length of 1.2 m has been designed at CEA and is being manufactured in collaboration with CERN. The magnet support structure is relying on self-supporting collars. We present here the mechanical analysis along with the assembly of the short model magnet from coil fabrication and mechanical characterization to collaring and yoking.