Angela Ridwan-Pramana
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Angela Ridwan-Pramana has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Pedro Molinero-Mourelle
Department of Conservative Dentistry and Prosthodontics, Faculty of Dentistry Complutense University of Madrid Madrid Spain
3 shared publications - Tymour Forouzanfar
Department of Oral and Maxillofacial Surgery Leiden University Medical Center (LUMC) Leiden The Netherlands
3 shared publications - Waqas Tanveer
Department of Oral and Maxillofacial Surgery, Amsterdam University Medical Center, 1081 HV Amsterdam, The Netherlands
3 shared publications - Frank K. J. Leusink
Department of Oral and Maxillofacial Surgery, University Medical Centre Utrecht, Utrecht, The Netherlands
1 shared publication - Gustaaf J. C. van Baar
Department of Oral and Maxillofacial Surgery/Pathology, Amsterdam UMC and Academic Center for Dentistry Amsterdam (ACTA), Vrije Universiteit Amsterdam, Amsterdam, the Netherlands
1 shared publication - Henri A. H. Winters
Department of Plastic Surgery, Amsterdam University Medical Center, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands
1 shared publication
Latest Publications
- Open Access
- 13 September 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (18) , 5950
Applications of CAD/CAM Technology for Craniofacial Implants Placement and Manufacturing of Auricular Prostheses—Systematic Review
This systematic review was aimed at gathering the clinical and technical applications of CAD/CAM technology for craniofacial implant placement and processing of auricular prostheses based on clinical cases. According to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines, an electronic data search was performed. Human clinical studies utilizing digital planning, designing, and printing systems for craniofacial implant placement and processing of auricular prostheses for prosthetic rehabilitation of auricular defects were included. Following a data search, a total of 36 clinical human studies were included, which were digitally planned and executed through various virtual software to rehabilitate auricular defects. Preoperative data were collected mainly through computed tomography scans (CT scans) (55 cases); meanwhile, the most common laser scanners were the 3dMDface System (3dMD LLC, Atlanta, Georgia, USA) (6 cases) and the 3 Shape scanner (3 Shape, Copenhagen, Denmark) (6 cases). The most common digital design software are Mimics Software (Mimics Innovation Suite, Materialize, Leuven, Belgium) (18 cases), Freeform software (Freeform, NC, USA) (13 cases), and 3 Shape software (3 Shape, Copenhagen, Denmark) (12 cases). Surgical templates were designed and utilized in 35 cases to place 88 craniofacial implants in auricular defect areas. The most common craniofacial implants were Vistafix craniofacial implants (Entific Medical Systems, Goteborg, Sweden) in 22 cases. A surgical navigation system was used to place 20 craniofacial implants in the mastoid bone. Digital applications of CAD/CAM technology include, but are not limited to, study models, mirrored replicas of intact ears, molds, retentive attachments, customized implants, substructures, and silicone prostheses. The included studies demonstrated a predictable clinical outcome, reduced the patient’s visits, and completed the prosthetic rehabilitation in reasonable time and at reasonable cost. However, equipment costs and trained technical staff were highlighted as possible limitations to the use of CAD/CAM systems.
- 13 September 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (18) , 5950
Open AccessApplications of CAD/CAM Technology for Craniofacial Implants Placement and Manufacturing of Auricular Prostheses—Systematic Review
This systematic review was aimed at gathering the clinical and technical applications of CAD/CAM technology for craniofacial implant placement and processing of auricular prostheses based on clinical cases. According to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines, an electronic data search was performed. Human clinical studies utilizing digital planning, designing, and printing systems for craniofacial implant placement and processing of auricular prostheses for prosthetic rehabilitation of auricular defects were included. Following a data search, a total of 36 clinical human studies were included, which were digitally planned and executed through various virtual software to rehabilitate auricular defects. Preoperative data were collected mainly through computed tomography scans (CT scans) (55 cases); meanwhile, the most common laser scanners were the 3dMDface System (3dMD LLC, Atlanta, Georgia, USA) (6 cases) and the 3 Shape scanner (3 Shape, Copenhagen, Denmark) (6 cases). The most common digital design software are Mimics Software (Mimics Innovation Suite, Materialize, Leuven, Belgium) (18 cases), Freeform software (Freeform, NC, USA) (13 cases), and 3 Shape software (3 Shape, Copenhagen, Denmark) (12 cases). Surgical templates were designed and utilized in 35 cases to place 88 craniofacial implants in auricular defect areas. The most common craniofacial implants were Vistafix craniofacial implants (Entific Medical Systems, Goteborg, Sweden) in 22 cases. A surgical navigation system was used to place 20 craniofacial implants in the mastoid bone. Digital applications of CAD/CAM technology include, but are not limited to, study models, mirrored replicas of intact ears, molds, retentive attachments, customized implants, substructures, and silicone prostheses. The included studies demonstrated a predictable clinical outcome, reduced the patient’s visits, and completed the prosthetic rehabilitation in reasonable time and at reasonable cost. However, equipment costs and trained technical staff were highlighted as possible limitations to the use of CAD/CAM systems.
- Open Access
- 28 October 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (21) , 11349
Systematic Review of Clinical Applications of CAD/CAM Technology for Craniofacial Implants Placement and Manufacturing of Orbital Prostheses
This systematic review was aimed at gathering technical and clinical applications of CAD/CAM technology for the preoperative planning of craniofacial implants placement, designing of molds and substructures and fabrication of orbital prostheses. Following the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines, an electronic search was executed. Human studies that utilized digital planning systems for the prosthetic rehabilitation of orbital defects were included. A total of 16 studies of 30 clinical cases, which were virtually planned through various digital planning and designing software, were included. The most common preoperative data required for digital planning were CT scans in 15 cases, the 3DSS-STD-II scanning system in 5 cases, an Artec Color 3D scanner in 3 cases and a NextEngine Desktop 3D laser scanner in 2 cases. Meanwhile, the digital designing software were Ease Orbital Implant Planning EOIPlan software in eight cases, Geomagic software in eight cases, Simplant software in four cases and Artec Studio 12 Professional in three cases. Surgical templates were fabricated for 12 cases to place 41 craniofacial implants in the orbital defect area. An image-guided surgical navigation system was utilized for the placement of five orbital implants in two cases. Digital designing and printing systems were reported for the preoperative planning of craniofacial implants placement, designing of molds and substructures and fabrication of orbital prostheses. The studies concluded that the digital planning, designing and fabrication of orbital prostheses reduce the clinical and laboratory times, reduces patient visits and provide a satisfactory outcome; however, technical skills and equipment costs are posing limitations on the use of these digital systems.
- 28 October 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (21) , 11349
Open AccessSystematic Review of Clinical Applications of CAD/CAM Technology for Craniofacial Implants Placement and Manufacturing of Orbital Prostheses
This systematic review was aimed at gathering technical and clinical applications of CAD/CAM technology for the preoperative planning of craniofacial implants placement, designing of molds and substructures and fabrication of orbital prostheses. Following the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines, an electronic search was executed. Human studies that utilized digital planning systems for the prosthetic rehabilitation of orbital defects were included. A total of 16 studies of 30 clinical cases, which were virtually planned through various digital planning and designing software, were included. The most common preoperative data required for digital planning were CT scans in 15 cases, the 3DSS-STD-II scanning system in 5 cases, an Artec Color 3D scanner in 3 cases and a NextEngine Desktop 3D laser scanner in 2 cases. Meanwhile, the digital designing software were Ease Orbital Implant Planning EOIPlan software in eight cases, Geomagic software in eight cases, Simplant software in four cases and Artec Studio 12 Professional in three cases. Surgical templates were fabricated for 12 cases to place 41 craniofacial implants in the orbital defect area. An image-guided surgical navigation system was utilized for the placement of five orbital implants in two cases. Digital designing and printing systems were reported for the preoperative planning of craniofacial implants placement, designing of molds and substructures and fabrication of orbital prostheses. The studies concluded that the digital planning, designing and fabrication of orbital prostheses reduce the clinical and laboratory times, reduces patient visits and provide a satisfactory outcome; however, technical skills and equipment costs are posing limitations on the use of these digital systems.
- Open Access
- 3 April 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (7) , 3756
Systematic Review of Clinical Applications of CAD/CAM Technology for Craniofacial Implants Placement and Manufacturing of Nasal Prostheses
The aim of this systematic review was to gather the clinical and laboratory applications of CAD/CAM technology for preoperative planning, designing of an attachment system, and manufacturing of nasal prostheses. According to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, an electronic search was carried out. Only human clinical studies involving digital planning for the rehabilitation of facial defects were included. A total of 21 studies were included with 23 patients, which were virtually planned through different planning software. The most common preoperative data for digital planning were CT scans in nine cases, CBCT in six cases, and laser scans in six cases. The reported planning softwares were Mimics in six cases, Geomagic Studio software in six cases, ZBrush in four cases, and Freeform plus software in four cases. Ten surgical templates were designed and printed to place 36 implants after digital planning, while post-operative assessment was done in two cases to check the accuracy of planned implants. Digital 3D planning software was reported for presurgical planning and craniofacial implants placement, fabrication of molds, designing of implants, designing of retentive attachments, and printing of silicone prostheses. Digital technology has been claimed to reduce the clinical and laboratory time; however, the equipment cost is still one of the limitations.
- 3 April 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (7) , 3756
Open AccessSystematic Review of Clinical Applications of CAD/CAM Technology for Craniofacial Implants Placement and Manufacturing of Nasal Prostheses
The aim of this systematic review was to gather the clinical and laboratory applications of CAD/CAM technology for preoperative planning, designing of an attachment system, and manufacturing of nasal prostheses. According to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, an electronic search was carried out. Only human clinical studies involving digital planning for the rehabilitation of facial defects were included. A total of 21 studies were included with 23 patients, which were virtually planned through different planning software. The most common preoperative data for digital planning were CT scans in nine cases, CBCT in six cases, and laser scans in six cases. The reported planning softwares were Mimics in six cases, Geomagic Studio software in six cases, ZBrush in four cases, and Freeform plus software in four cases. Ten surgical templates were designed and printed to place 36 implants after digital planning, while post-operative assessment was done in two cases to check the accuracy of planned implants. Digital 3D planning software was reported for presurgical planning and craniofacial implants placement, fabrication of molds, designing of implants, designing of retentive attachments, and printing of silicone prostheses. Digital technology has been claimed to reduce the clinical and laboratory time; however, the equipment cost is still one of the limitations.
- Open Access
- 16 March 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (6) , 1226
Accuracy of Computer-Assisted Surgery in Maxillary Reconstruction: A Systematic Review
Computer-assisted surgery (CAS) in maxillary reconstruction has proven its value regarding more predictable postoperative results. However, the accuracy evaluation methods differ between studies, and no meta-analysis has been performed yet. A systematic review was performed in the PubMed, Embase, and Cochrane Library databases, using a Patient, Intervention, Comparison and Outcome (PICO) method: (P) patients in need of maxillary reconstruction using free osteocutaneous tissue transfer, (I) reconstructed according to a virtual plan in CAS software, (C) compared to the actual postoperative result, and (O) postoperatively measured by a quantitative accuracy assessment) search strategy, and was reported according to the PRISMA statement. We reviewed all of the studies that quantitatively assessed the accuracy of maxillary reconstructions using CAS. Twelve studies matched the inclusion criteria, reporting 67 maxillary reconstructions. All of the included studies compared postoperative 3D models to preoperative 3D models (revised to the virtual plan). The postoperative accuracy measurements mainly focused on the position of the fibular bony segments. Only approximate comparisons of postoperative accuracy between studies were feasible because of small differences in the postoperative measurement methods; the accuracy of the bony segment positioning ranged between 0.44 mm and 7.8 mm, and between 2.90° and 6.96°. A postoperative evaluation guideline to create uniformity in evaluation methods needs to be considered so as to allow for valid comparisons of postoperative results and to facilitate meta-analyses in the future. With the proper validation of the postoperative results, future research might explore more definitive evidence regarding the management and superiority of CAS in maxillary and midface reconstruction.
- 16 March 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (6) , 1226
Open AccessAccuracy of Computer-Assisted Surgery in Maxillary Reconstruction: A Systematic Review
Computer-assisted surgery (CAS) in maxillary reconstruction has proven its value regarding more predictable postoperative results. However, the accuracy evaluation methods differ between studies, and no meta-analysis has been performed yet. A systematic review was performed in the PubMed, Embase, and Cochrane Library databases, using a Patient, Intervention, Comparison and Outcome (PICO) method: (P) patients in need of maxillary reconstruction using free osteocutaneous tissue transfer, (I) reconstructed according to a virtual plan in CAS software, (C) compared to the actual postoperative result, and (O) postoperatively measured by a quantitative accuracy assessment) search strategy, and was reported according to the PRISMA statement. We reviewed all of the studies that quantitatively assessed the accuracy of maxillary reconstructions using CAS. Twelve studies matched the inclusion criteria, reporting 67 maxillary reconstructions. All of the included studies compared postoperative 3D models to preoperative 3D models (revised to the virtual plan). The postoperative accuracy measurements mainly focused on the position of the fibular bony segments. Only approximate comparisons of postoperative accuracy between studies were feasible because of small differences in the postoperative measurement methods; the accuracy of the bony segment positioning ranged between 0.44 mm and 7.8 mm, and between 2.90° and 6.96°. A postoperative evaluation guideline to create uniformity in evaluation methods needs to be considered so as to allow for valid comparisons of postoperative results and to facilitate meta-analyses in the future. With the proper validation of the postoperative results, future research might explore more definitive evidence regarding the management and superiority of CAS in maxillary and midface reconstruction.