Annika Hagemann
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Annika Hagemann has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Christoph Stiller
Institute of Measurement and Control, Karlsruhe Institute of Technology
1 shared publication- Christoph Stiller
Karlsruhe Institute of Technology
1 shared publication Holger Janssen
Robert Bosch GmbH, Corporate Research, Computer Vision Research Lab
1 shared publication- Holger Janssen
Robert Bosch GmbH, Corporate Research, Computer Vision, Hildesheim, Germany
1 shared publication - Jan Fabian Schmid
Indicates equal contribution
1 shared publication Moritz Knorr
Robert Bosch GmbH, Corporate Research, Computer Vision Research Lab
1 shared publication
Latest Publications
- Open Access
XRefine: Attention-Guided Keypoint Match Refinement
Sparse keypoint matching is crucial for 3D vision tasks, yet current keypoint detectors often produce spatially inaccurate matches. Existing refinement methods mitigate this issue through alignment of matched keypoint locations, but they are typically detector-specific, requiring retraining for each keypoint detector. We introduce XRefine, a novel, detector-agnostic approach for sub-pixel keypoint refinement that operates solely on image patches centered at matched keypoints. Our cross-attention-based architecture learns to predict refined keypoint coordinates without relying on internal detector representations, enabling generalization across detectors. Furthermore, XRefine can be extended to handle multi-view feature tracks. Experiments on MegaDepth, KITTI, and ScanNet demonstrate that the approach consistently improves geometric estimation accuracy, achieving superior performance compared to existing refinement methods while maintaining runtime efficiency. Our code and trained models can be found at https://github.com/boschresearch/xrefine.
Open AccessXRefine: Attention-Guided Keypoint Match Refinement
Sparse keypoint matching is crucial for 3D vision tasks, yet current keypoint detectors often produce spatially inaccurate matches. Existing refinement methods mitigate this issue through alignment of matched keypoint locations, but they are typically detector-specific, requiring retraining for each keypoint detector. We introduce XRefine, a novel, detector-agnostic approach for sub-pixel keypoint refinement that operates solely on image patches centered at matched keypoints. Our cross-attention-based architecture learns to predict refined keypoint coordinates without relying on internal detector representations, enabling generalization across detectors. Furthermore, XRefine can be extended to handle multi-view feature tracks. Experiments on MegaDepth, KITTI, and ScanNet demonstrate that the approach consistently improves geometric estimation accuracy, achieving superior performance compared to existing refinement methods while maintaining runtime efficiency. Our code and trained models can be found at https://github.com/boschresearch/xrefine.
- 18 October 2021
- Published by Springer Nature in International Journal of Computer Vision
- Vol. 130 (1) , 17-32
Inferring Bias and Uncertainty in Camera Calibration
- 18 October 2021
- Published by Springer Nature in International Journal of Computer Vision
- Vol. 130 (1) , 17-32
Inferring Bias and Uncertainty in Camera Calibration
- 17 March 2021
- Published by Springer Nature
- Vol. 12544, 30-43
Bias Detection and Prediction of Mapping Errors in Camera Calibration
Camera calibration is a prerequisite for many computer vision applications. While a good calibration can turn a camera into a measurement device, it can also deteriorate a system’s performance if not done correctly. In the recent past, there have been great efforts to simplify the calibration process. Yet, inspection and evaluation of calibration results typically still requires expert knowledge. In this work, we introduce two novel methods to capture the fundamental error sources in camera calibration: systematic errors (biases) and remaining uncertainty (variance). Importantly, the proposed methods do not require capturing additional images and are independent of the camera model. We evaluate the methods on simulated and real data and demonstrate how a state-of-the-art system for guided calibration can be improved. In combination, the methods allow novice users to perform camera calibration and verify both the accuracy and precision.
- 17 March 2021
- Published by Springer Nature
- Vol. 12544, 30-43
Bias Detection and Prediction of Mapping Errors in Camera Calibration
Camera calibration is a prerequisite for many computer vision applications. While a good calibration can turn a camera into a measurement device, it can also deteriorate a system’s performance if not done correctly. In the recent past, there have been great efforts to simplify the calibration process. Yet, inspection and evaluation of calibration results typically still requires expert knowledge. In this work, we introduce two novel methods to capture the fundamental error sources in camera calibration: systematic errors (biases) and remaining uncertainty (variance). Importantly, the proposed methods do not require capturing additional images and are independent of the camera model. We evaluate the methods on simulated and real data and demonstrate how a state-of-the-art system for guided calibration can be improved. In combination, the methods allow novice users to perform camera calibration and verify both the accuracy and precision.