Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Rudy Gianto has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Three-phase power flow solution of active distribution network using trust-region method

    by Rudy Gianto, M. Iqbal Arsyad, Managam Rajagukguk

    Distribution systems or networks are inherently unbalanced. As a result, single-phase power flow methods are generally no longer valid for such systems. Therefore, to obtain accurate results, unbalanced systems should be analyzed using three-phase power flow methods, which are far more complicated than the single-phase methods. Moreover, at present, the penetration of distributed generation (DG) in the distribution network has significantly increased. DG integration will increase the complication of the power flow analysis as it changes the network's basic configuration from passive to active system. This computational burden will significantly be higher if the power flow calculation has to be conducted several times (for example, in feeder reconfigurations or service restorations). This paper investigates the utilization of the trust-region method in obtaining the solution to the three-phase power flow problem of an active distribution network (i.e., distribution network embedded with DG). Trust-region computation algorithm is robust and powerful since the optimization technique is employed in finding new solutions in the iteration process. Results obtained from three representative unbalanced distribution networks (i.e., 10-node, 19-node, and 25-node networks) verify the validity of the proposed method. The effects of DG installation on distribution network steady-state performances are also investigated in the present paper.

  • Open Access

    Three-phase model of SCIG-based variable speed wind turbine for unbalanced DSLF analysis

    by Ismail Yusuf, Rudy Gianto

    Steady state performances of the electric power distribution system are normally assessed or evaluated based on load flow analysis. To properly carry out the analysis, a valid steady state load flow model of each distribution system component, including the wind power plant (WPP), needs to be developed. The present paper proposes a method for modeling and integrating squirrel cage induction generator (SCIG)-based variable speed WPP into a three-phase unbalanced distribution system load flow (DSLF) analysis. The proposed method is based on a single-phase T-circuit model of fixed speed WPP, which has successfully been applied to balanced electric power systems. In the present work, the single-phase T-circuit model is extended and modified to be used in steady state load flow analysis of three-phase unbalanced distribution systems embedded with SCIG-based variable speed WPP. Results of the case studies confirm the validity of the proposed method.


  • Open Access

    Multiple-node model of wind turbine generating system for unbalanced distribution system load flow analysis

    by Rudy Gianto, Kho Hie Khwee

    This paper discusses a method to integrate a wind turbine generating system (WTGS) into a three-phase unbalanced distribution system load flow (DSLF) analysis. The proposed method is based on the single-phase multiple-node model. In the present work, the single-phase multiple-node model is extended to a three-phase multiple-node model to facilitate the load flow analysis of a three-phase unbalanced power system network. The multiple-node model (i.e., three-node model) will only modify the load flow analysis by introducing two lines and two load buses to the distribution system network where the WTGS is installed. Thus, a standard three-phase load flow program can be employed to compute the unknown quantities in the DSLF problem formulation. The proposed method is verified by incorporating the model into the load flow analysis of three-phase distribution networks. The investigation uses two representative distribution networks (i.e., 19-bus and 25-bus networks). The results of the study confirm the validity of the proposed method.


  • Open Access

    Model Tegangan Konstan Dari Pembangkit Listrik Tenaga Angin Kecepatan Variabel Yang Berbasis SCIG Untuk Analisis Aliran Daya

    by Rudy Gianto

    Belakangan ini, aplikasi pembangkit listrik tenaga angin (PLTAn) kecepatan variabel semakin populer dan telah melampaui penggunaan PLTAn kecepatan tetap. Kepopuleran ini terutama disebabkan karena PLTAn kecepatan variabel jauh lebih efisien dalam menangkap atau mengekstraksi energi angin dibandingkan PLTAn kecepatan tetap. Salah satu jenis PLTAn kecepatan variabel yang saat ini penggunaannya semakin meningkat karena biayanya yang relatif lebih murah adalah PLTAn kecepatan variabel yang berbasis SCIG (Squirrel Cage Induction Generator). PLTAn jenis ini biasanya dilengkapi dengan konverter elektronika daya untuk memperoleh rentang operasi kecepatan variabel yang lebih lebar. Agar dapat melakukan analisis dari suatu sistem tenaga listrik (termasuk analisis aliran daya), pemodelan komponen-komponen sistem tersebut sangat diperlukan. Makalah ini membahas model keadaan mantap PLTAn kecepatan variabel yang berbasis SCIG untuk analisis aliran daya sistem distribusi tenaga listrik. Model yang diusulkan ini dapat digunakan pada PLTAn kecepatan variabel berbasis SCIG dengan mode operasi kontrol tegangan. Model tersebut dikembangkan berdasarkan rumus-rumus yang menghitung input daya mekanik turbin dan output daya listrik PLTAn. Makalah ini juga membahas studi kasus dimana pada studi tersebut dilakukan penyelidikan tentang aplikasi dari usulan model pada suatu sistem distribusi tenaga listrik.

  • Open Access

    Constant Voltage Model of SCIG-Based Variable Speed Wind Power Plant for Load Flow Analysis

    by Rudy Gianto

    In recent years, the application of variable-speed wind power plants (WPPs) has become more and more popular and surpassed fixed-speed WPPs. This popularity is mainly because variable-speed WPPs are much more efficient in capturing or extracting wind energy than fixed-speed WPPs. Due to its relatively cheaper cost, the use of SCIG (Squirrel Cage Induction Generator)-based variable-speed WPP is currently increasing. This type of WPP is usually equipped with a power electronics converter to obtain a broader range of variable-speed operations. Modeling the power system components is undoubtedly necessary for performing the system analysis (including load flow analysis). This paper discusses the steady-state model of SCIG-based variable-speed WPP for load flow analysis of electric power distribution systems. The proposed model can be used for SCIG-based variable-speed WPP with voltage control operating mode. The model was developed based on formulas that calculate the turbine mechanical power input and the WPP electrical power output. This paper also presents a case study in which the proposed model is applied to a representative electric power distribution system.

  • Open Access

    ENERGY AUDIT ON LIGHTING AND AIR CONDITIONING SYSTEMS AT AL-AZHAR ISLAMIC SCHOOL

    by Yusvian Khabaranus, Purwoharjono Purwoharjono, Rudy Gianto

    Based on Government Regulation No. 70 of 2009 concerning energy conservation, it is stated that the use of energy by energy sources and users must be carried out sparingly and efficiently. Based on these regulations, this thesis was made with the aim of analyzing opportunities for saving electrical energy in the Islamic Middle School Al-Azhar 17 Pontianak and Islamic High School Al-Azhar 10 Pontianak buildings. Data collection was carried out from December 2022 to January 2023. The results of the analysis obtained 2 recommendations for saving electricity. In the first option, for the lighting system it is done by changing TL lamps to LEDs, requiring 240 LED lamps and for the air conditioning system it is done by changing the refrigerant to Musicool MC-22. Estimated electricity savings of 17%. The payback period is 2 years, 3 months. In the second option, 446 LED lamps were also replaced with TL lamps to LEDs. For the air conditioning system, the AC is replaced with an inverter type. Estimated electricity savings of 61.13%. The payback period is 2 years, 2 months. From the results of this analysis, energy conservation efforts to get electricity savings and cost savings are very feasible in these schools.

  • Open Access

    Steady-State Load Flow Model of DFIG Wind Turbine Based on Generator Power Loss Calculation

    by Rudy Gianto, Purwoharjono, Fitri Imansyah, Rudi Kurnianto, Danial

    Penetration of wind power plants (WPPs) in the electric power system will complicate the system load flow analysis. Consequently, the traditional load flow algorithm can no longer be used to find the solution to the load flow problem of such a system. This paper proposes a doubly fed induction generator (DFIG)-based WPP model for a load flow analysis of the electric power system. The proposed model is derived based on the power formulations of the WPP—namely, DFIG power, DFIG power loss, and WPP power output formulas. The model can be applied to various DFIG power factor operating modes. In the present paper, applications of the proposed methods in two representative electric power systems (i.e., IEEE 14-bus and 30-bus systems) have been investigated. The investigation results verify the proposed method’s capability to solve the load flow problem of the system embedded with DFIG-based variable-speed WPPs.


  • Open Access

    Constant Power Factor Model of DFIG-Based Wind Turbine for Steady State Load Flow Studies

    by Rudy Gianto

    DFIG (Doubly Fed Induction Generator)-based WPP (Wind Power Plant) is the most popular type of wind-driven electric power generation configuration. The main reason for its popularity is that the DFIG system can capture wind energy more optimally than other WPP configurations. Due to the increasing penetration of WPP in power systems, the need to study its impact on power system performance is becoming increasingly important. To enable such a study to be conducted properly, the first and probably the most crucial step is to model all system components (including the WPP). This paper proposes a new steady state model of DFIG-based WPP for load flow analysis. The proposed model is derived based on DFIG power formulas (i.e., DFIG stator and rotor power formulas). The model in the present work is simple and can easily be incorporated into load flow analysis. Representation of the DFIG in both sub-synchronous and super-synchronous conditions can be carried out by using a single mathematical model. Furthermore, since DFIG can be operated at a constant power factor (i.e., unity, leading, or lagging power factor), this important feature is also considered in the proposed model development.


  • Open Access

    Two-port network model of wind turbine generator for three-phase unbalanced distribution system load flow analysis

    by Rudy Gianto, Purwoharjono Purwoharjono

    An unbalanced electric power system can occur due to unequal lines and/or loads in each phase of the system. For a system with a high level of unbalance, the assumption that the system is balanced becomes incorrect. For a case like this, the system must be analyzed using three-phase approaches because single-phase analysis techniques can no longer be used to obtain accurate results. Therefore, the development of three-phase models of all components of the electric power system, including the wind turbine generating system (WTGS), is very important so that the system can properly be analyzed and its performance can correctly be evaluated. This paper proposes a method to incorporate WTGS in a three-phase load flow analysis of an unbalanced distribution system. The proposed method is based on the previously published single-phase two-port network model. In this paper, the single-phase two-port network model is modified and extended so that it can be applied to unbalanced systems. The model is then included in the three-phase distribution system load flow (DSLF) analysis. The proposed method is validated using 12-node and 19-node distribution systems.


  • Open Access

    Trust-Region Method for Load Flow Solution of Three-Phase Unbalanced Electric Power Distribution System

    by Rudy Gianto, Purwoharjono

    At present, the electric power system is getting bigger and more complex, and its loading is also increasing. As a consequence, planning, operation, and control of the power system also become more complicated. It is known that system planning and operation are mostly based on the steady-state condition of the power system, and the system steady-state condition can only be determined from the load flow study. Thus, the development of a reliable and efficient method to solve the load flow problem is necessary so that the system steady-state condition can properly be evaluated. Since the characteristics of the electric distribution system are different from those of the transmission system, special treatments are usually required in the distribution system load flow (DSLF) analysis. In this context, several interesting techniques have been proposed in the analysis. In this paper, the application and extension of the trust-region method to solve the three-phase DSLF problem are proposed and investigated. Case studies using 19-node, 25-node, and 123-node distribution systems are also given in this paper. Results of the studies show that the output values obtained by the proposed method are in excellent agreement with those obtained by previously published methods. These results confirm the validity of the proposed method. Case study results also indicate that the proposed method has better computational performances than the forward/backward sweeping (FBS) method.