  • Stability Analysis for VSR-Based DC Distribution Network Using Singular Perturbation Theory

    by Zhenxi Wu, Chi K. Tse, Zhangjie Liu, Chao Charles Liu, Hang Li, Hua Han, Yao Sun

    This paper addresses the stability analysis of DC distribution networks with voltage source rectifiers (VSRs) and constant power loads (CPLs). Existing stability criteria for DC networks often rely on simplified models neglecting source converter controller dynamics, limiting their applicability in practical controller design. To overcome this, a singular perturbation-based framework is proposed to derive analytical stability conditions for closed-loop DC distribution network systems. By decomposing the high-dimensional Jacobian matrix into two structured low-dimensional matrices, tractable stability criteria are established using properties of Karush-Kuhn-Tucker (KKT) matrices. Sufficient stability conditions for local stability of a VSR-based DC distribution network are derived without requiring global VSR information, while a robust stability criterion dependent solely on maximum load data is developed to handle uncertainties. These results provide explicit design guidelines to enhance robustness and reduce computational complexity in stability analysis. Simulations validate the effectiveness of the proposed approach.


  • Transient Stability Enhancement of Multi-Inverter Microgrids

    by Jingxi Yang, Chi K. Tse, Meng Huang, Dong Liu, Xikun Fu, Chao Charles Liu

    Large-scale distributed renewable energy sources (RESs) are entering the power system through grid-forming and grid-following inverters (GFMIs and GFLIs). These inverters can cluster together to create an islanded microgrid that optimizes the use of RESs. However, the microgrid may lose synchronization during a temporary short-circuit fault. It has been observed that the critical fault clearing time can increase if GFLIs inject a significant amount of reactive power or if GFMIs operate at slightly higher cutoff frequencies in their low-pass filters. This phenomenon is related to a specific hidden periodic orbit and the relative region of the stable equilibrium point's (SEP's) basin of attraction. Due to the presence of the aforementioned hidden periodic orbit, the phase-locked loop is able to operate normally during the fault, which effectively ensures the synchronization stability for the post-fault system. The sustainability of this hidden periodic orbit depends on the appropriate injection of reactive power by GFLIs. Moreover, increasing the cutoff frequencies of GFMIs leads to a homoclinic bifurcation, which enlarges the SEP's basin of attraction and guarantees successful resynchronization of the inverters after the fault is cleared. Simulations and experiments have confirmed these findings.


  • Design-Oriented Transient Stability Analysis of Grid-Connected Converters: A Comparative Study of Analysis Methods

    by Chao Charles Liu, Chi K. Tse, Meng Huang, Zhenxi Wu, Hua Han, Jingxi Yang

    Transient stability analysis of grid-connected converters can provide guidance for practical design. Previous studies have summarized monotonic relationships between stability and parameters. Given the complex nonlinear behavior of converter-based systems, these monotonic relationships are incomplete. In this article, design guidelines in the form of feasible parameter ranges are developed. Sensitivity analysis and bifurcation diagrams are utilized to derive feasible parameter ranges from typical stability analysis methods, including time-domain simulation, energy-based methods (manually derived and algorithmically searched), and bifurcation analysis. It is found that different analysis methods may provide equivalent design guidelines due to the similar sensitivity patterns identified by these methods. Furthermore, we reveal that the change in the sensitivity patterns can be induced by the bifurcation behavior of grid-connected converters. Therefore, the qualitative differences between the stability analysis methods are determined by their ability to capture the various bifurcations crucial for determining transient stability. Our results show different levels of consistency between the analysis methods. The findings are verified by laboratory experiments.


  • Nonlinear Behavior and Transient Stability of Grid-Following Converters Using Direct Power Control Under Weak Grid

    by Chao Charles Liu, Chi K. Tse, Jingxi Yang

    Ensuring reliable operation of renewable energy sources requires robust grid-connected converters. Depending on the choice of synchronization methods, grid-connected converters may exhibit distinct nonlinear behavior that plays a vital role in determining their transient stability. Recently, the grid-voltage-modulated direct power control (DPC) has been proposed as an alternative to the conventional phase-locked loop (PLL) to enhance the dynamic response of the grid-following converter (GFLC). However, existing studies have primarily treated the DPC-based GFLC as a linear system. In this paper, we investigate the nonlinear behavior of this converter under weak grids using a large-signal model based on double reference frames. Our findings reveal that the DPC-based GFLC demonstrates sustained oscillation. Interestingly, the stable periodic orbit observed does not arise from a Hopf bifurcation but rather a saddle-node bifurcation of periodic orbits. This critical bifurcation is characterized by the coexistence of a stable periodic orbit and a stable equilibrium point, resulting in a sudden contraction of the converter's stability region. Furthermore, we provide a comparison between the nonlinear behavior of PLL-based GFLCs and DPC-based GFLCs. To validate our findings, we present full-circuit simulations and laboratory experiments.


  • Stability Analysis and Design of Islanded Microgrids Integrating Pinning-Based and Consensus-Based Distributed Secondary Control

    by Jingxi Yang, Chao Charles Liu, Chi K. Tse, Meng Huang

    In this article, the impact of pinning-based and consensus-based distributed secondary control on the stability of islanded microgrids is studied. A nonlinear model of the islanded microgrid is first established, incorporating the voltage-loop dynamics and communication delay. Using this model, the influence of the secondary control on the microgrid's dynamical behavior is explored, and in particular, the improved robustness and stability contributed by the voltage-increment-based secondary control is highlighted. Besides, the effects of the topology of communication networks and the selection of driver controllers on the system stability are revealed, and such effects are quantitatively measured by the algebraic connectivity and the conditional number. Moreover, small-signal models and the corresponding loop gains are derived for expediting the selection of suitable secondary control parameters. Furthermore, a design procedure of the distributed secondary control system is demonstrated. Finally, analytical findings are verified by cycle-by-cycle full-circuit simulations and laboratory experiments.


  • Transient Synchronization Stability of Grid-Following Converters Considering Nonideal Current Loop

    by Chao Charles Liu, Jingxi Yang, Chi K. Tse, Meng Huang

    The widely deployed grid-following converters (GFLCs) may lose synchronization under grid disturbances, presenting a critical challenge to the power electronics penetrated power grid. Existing methods for analyzing transient synchronization stability often assume an ideal current loop in order to keep the system model at low order. However, such approaches based on a simplified second-order model can lead to optimistic stability prediction and inappropriate design. This paper applies a full-order model to explore the effects of the nonideal current loop. The unstable periodic orbits (UPOs) that determine the basin of attraction of the stable equilibrium point are located via a numerical continuation method. Moreover, the essential bifurcations leading to the emergence and disappearance of UPOs are identified. A design principle with consideration of the effects of the nonideal current loop is derived to enhance the transient synchronization stability of GFLCs. Experimental results are provided to verify the analytical findings.


  • Comparison of Homoclinic Bifurcations Between Grid-Following and Grid-Forming Converters

    by Jingxi Yang, Chi K. Tse, Meng Huang, Dong Liu, Chao Charles Liu, Xikun Fu

    A second-order model is developed to describe the essential behavior of the grid-following converter (GFLC) and the grid-forming converter (GFMC) for studying the synchronization characteristics of grid-connected converter systems. In this article, a general set of criteria in terms of the manifolds and saddle quantity is derived for studying the homoclinic bifurcation behavior of GFLCs and GFMCs. It is shown that three unstable periodic orbits and two homoclinic bifurcations may exist for the GFLC, while only one stable periodic orbit and one homoclinic bifurcation may exist for the GFMC. It is also found that after the onset of the first homoclinic bifurcation, the stable equilibrium point (SEP) is surrounded by the stable manifolds of the unstable equilibrium point (UEP), which forms the SEP's basin of attraction, for both GFLCs and GFMCs. In this case, the converters may lose their synchronization if the trajectory crosses over the UEP. Therefore, system parameters should be designed to avoid the onset of the aforementioned bifurcation so that the SEP's basin of attraction can be significantly enlarged to contain the UEP. As a result, the GFLC or GFMC can eventually resynchronize with the grid even when its trajectory passes the UEP. Finally, experimental results are provided to verify these theoretical findings.


  • Open Access

    Permutation test and bootstrap methods for unsupervised detection and estimation of behind‐the‐meter photovoltaic generation

    by Chao Liu, Jing Shi, Hongkun Chen, Lei Chen, Guocheng Li

    The penetration of unmonitored behind‐the‐meter photovoltaic systems has increased rapidly over the past decade. While unsupervised methods have been proposed to estimate behind‐the‐meter photovoltaic generation, their performance is significantly affected by hyperparameters. Existing methods for choosing hyperparameters require labelled data, which are unavailable to system operators. In this paper, a data‐driven method is proposed to generate labelled data to optimize the hyperparameters for unsupervised estimation of behind‐the‐meter photovoltaic generation. First, a permutation‐test based method is developed to detect photovoltaic installation in an unsupervised way. Second, consumers without PV are combined with limited monitored photovoltaic sites to simulate the original system through the bootstrap method. The simulated system provides labelled data for hyperparameter optimization. Finally, the near‐optimal hyperparameters are searched on the simulated system and applied to the original system's estimation. Through experiments on a smart meter dataset, the effectiveness of the proposed methodology is verified.