Marco Ferraris
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Marco Ferraris has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Alessandro Spagni
Laboratory of Technologies for Waste, Wastewater and Raw Materials Management, Italian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA), via M.M. Sole 4, 40129, Bologna, Italy
6 shared publications Gianpaolo Sabia
ENEA, Water Resources Management Laboratory, via M.M. Sole, 4, 40129, Bologna, Italy
3 shared publicationsStefania Casu
ENEA (Italian National Agency for New Technologies, Energy and Sustainable Economic Development), Water Resource Management Section, Bologna, Italy
2 shared publicationsCarmela Maria Cellamare
1 shared publicationCarolina Innella
Waste Management Section, ENEA (Italian National Agency for New Technology, Energy and Environment), ss Jonica 106, km 419+500 75026 Rotondella (MT), Italy
1 shared publicationDavide Mattioli
ENEA (Italian National Agency for New Technologies, Energy and Sustainable Economic Development), Water Resource Management Section , Bologna , Italy
1 shared publication
Latest Publications
- 1 June 2021
- Published by American Society of Civil Engineers (ASCE) in Journal of Water Resources Planning and Management
- Vol. 147 (6) , 04021024
Automated Household Water End-Use Disaggregation through Rule-Based Methodology
Application of smart meters to the residential sector can provide insight into where and when water is used, thereby enabling utilities to achieve an efficient management of water distribution systems. Moreover, detailed information about domestic water use can be obtained by disaggregating smart meter data collected at the household inlet point. In this paper, a rule-based, automated methodology for disaggregating household water-use data into end uses is presented. The methodology is applicable to 1-min temporal resolution data, whose granularity is slightly lower than the one generally used in other methodologies, potentially allowing it to be applied to several contexts in the field of water-use monitoring. The methodology was set up and validated with data collected for 2 months through intrusive monitoring of four households in Bologna, Italy, and represents a pioneering case in which disaggregation performance is directly assessed by the comparison against data collected at each end use. The results obtained showed that the methodology enables household water use to be efficiently disaggregated even if detailed information about end-use features is not available.
- 1 June 2021
- Published by American Society of Civil Engineers (ASCE) in Journal of Water Resources Planning and Management
- Vol. 147 (6) , 04021024
Automated Household Water End-Use Disaggregation through Rule-Based Methodology
Application of smart meters to the residential sector can provide insight into where and when water is used, thereby enabling utilities to achieve an efficient management of water distribution systems. Moreover, detailed information about domestic water use can be obtained by disaggregating smart meter data collected at the household inlet point. In this paper, a rule-based, automated methodology for disaggregating household water-use data into end uses is presented. The methodology is applicable to 1-min temporal resolution data, whose granularity is slightly lower than the one generally used in other methodologies, potentially allowing it to be applied to several contexts in the field of water-use monitoring. The methodology was set up and validated with data collected for 2 months through intrusive monitoring of four households in Bologna, Italy, and represents a pioneering case in which disaggregation performance is directly assessed by the comparison against data collected at each end use. The results obtained showed that the methodology enables household water use to be efficiently disaggregated even if detailed information about end-use features is not available.
- 17 September 2015
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 23 (2) , 1598-1609
Model-based analysis of the effect of different operating conditions on fouling mechanisms in a membrane bioreactor
This study proposes a model-based evaluation of the effect of different operating conditions with and without pre-denitrification treatment and applying three different solids retention times on the fouling mechanisms involved in membrane bioreactors (MBRs). A total of 11 fouling models obtained from literature were used to fit the transmembrane pressure variations measured in a pilot-scale MBR treating real wastewater for more than 1 year. The results showed that all the models represent reasonable descriptions of the fouling processes in the MBR tested. The model-based analysis confirmed that membrane fouling started by pore blocking (complete blocking model) and by a reduction of the pore diameter (standard blocking) while cake filtration became the dominant fouling mechanism over long-term operation. However, the different fouling mechanisms occurred almost simultaneously making it rather difficult to identify each one. The membrane “history” (i.e. age, lifespan, etc.) seems the most important factor affecting the fouling mechanism more than the applied operating conditions. Nonlinear regression of the most complex models (combined models) evaluated in this study sometimes demonstrated unreliable parameter estimates suggesting that the four basic fouling models (complete, standard, intermediate blocking and cake filtration) contain enough details to represent a reasonable description of the main fouling processes occurring in MBRs.
- 17 September 2015
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 23 (2) , 1598-1609
Model-based analysis of the effect of different operating conditions on fouling mechanisms in a membrane bioreactor
This study proposes a model-based evaluation of the effect of different operating conditions with and without pre-denitrification treatment and applying three different solids retention times on the fouling mechanisms involved in membrane bioreactors (MBRs). A total of 11 fouling models obtained from literature were used to fit the transmembrane pressure variations measured in a pilot-scale MBR treating real wastewater for more than 1 year. The results showed that all the models represent reasonable descriptions of the fouling processes in the MBR tested. The model-based analysis confirmed that membrane fouling started by pore blocking (complete blocking model) and by a reduction of the pore diameter (standard blocking) while cake filtration became the dominant fouling mechanism over long-term operation. However, the different fouling mechanisms occurred almost simultaneously making it rather difficult to identify each one. The membrane “history” (i.e. age, lifespan, etc.) seems the most important factor affecting the fouling mechanism more than the applied operating conditions. Nonlinear regression of the most complex models (combined models) evaluated in this study sometimes demonstrated unreliable parameter estimates suggesting that the four basic fouling models (complete, standard, intermediate blocking and cake filtration) contain enough details to represent a reasonable description of the main fouling processes occurring in MBRs.
- 16 January 2015
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part A
- Vol. 50 (3) , 325-331
Modelling wastewater treatment in a submerged anaerobic membrane bioreactor
Mathematical modelling has been widely applied to membrane bioreactor (MBRs) processes. However, to date, very few studies have reported on the application of the anaerobic digestion model N.1 (ADM1) to anaerobic membrane processes. The aim of this study was to evaluate the applicability of the ADM1 to a submerged anaerobic MBR (SAMBR) treating simulated industrial wastewater composed of cheese whey and sucrose. This study demonstrated that the biological processes involved in SAMBRs can be modelled by using the ADM1. Moreover, the results showed that very few modifications of the parameters describing the ADM1 were required to reasonably fit the experimental data. In particular, adaptation to the specific conditions of the coefficients describing the wastewater characterisation and the reduction of the hydrolysis rate of particulate carbohydrate (khyd,ch) from 0.25 d-1 (as suggested by the ADM1 for high-rate mesophilic reactors) to 0.13 d-1 were required to fit the experimental data.
- 16 January 2015
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part A
- Vol. 50 (3) , 325-331
Modelling wastewater treatment in a submerged anaerobic membrane bioreactor
Mathematical modelling has been widely applied to membrane bioreactor (MBRs) processes. However, to date, very few studies have reported on the application of the anaerobic digestion model N.1 (ADM1) to anaerobic membrane processes. The aim of this study was to evaluate the applicability of the ADM1 to a submerged anaerobic MBR (SAMBR) treating simulated industrial wastewater composed of cheese whey and sucrose. This study demonstrated that the biological processes involved in SAMBRs can be modelled by using the ADM1. Moreover, the results showed that very few modifications of the parameters describing the ADM1 were required to reasonably fit the experimental data. In particular, adaptation to the specific conditions of the coefficients describing the wastewater characterisation and the reduction of the hydrolysis rate of particulate carbohydrate (khyd,ch) from 0.25 d-1 (as suggested by the ADM1 for high-rate mesophilic reactors) to 0.13 d-1 were required to fit the experimental data.
- 1 February 2014
- Published by Elsevier in Separation and Purification Technology
- Vol. 122, 297-305
Online monitoring of MBR fouling by transmembrane pressure and permeability over a long-term experiment
- 1 February 2014
- Published by Elsevier in Separation and Purification Technology
- Vol. 122, 297-305
Online monitoring of MBR fouling by transmembrane pressure and permeability over a long-term experiment
- 13 January 2012
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part A
- Vol. 47 (2) , 204-209
Wastewater treatment in a submerged anaerobic membrane bioreactor
Although most membrane bioreactors are used under aerobic conditions, over the last few years there has been increased interest in their application for anaerobic processes. This paper presents the results obtained when a bench-scale submerged anaerobic membrane bioreactor was used for the treatment of wastewaters generated in the agro-food industry. The reactor was fed with synthetic wastewater consisting of cheese whey and sucrose, and volumetric organic loading rates (OLRs) ranging from 1.5 to 13 kgCOD/(m3*d) were applied. Under the operating conditions studied, the maximum applicable OLR was between 6 and 10 gCOD/(g*L), which fell within the ranges of the high-rate anaerobic wastewater treatment systems, while high concentrations of volatile fatty acids were produced at higher OLR rates. With an OLR of 1.5–10 gCOD/(g*L), the reactor showed 94% COD removal, whereas this value dropped to 33% with the highest applied OLR of 13 gCOD/(g*L). The study therefore confirms that membrane bioreactors can be used for anaerobic wastewater treatment.
- 13 January 2012
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part A
- Vol. 47 (2) , 204-209
Wastewater treatment in a submerged anaerobic membrane bioreactor
Although most membrane bioreactors are used under aerobic conditions, over the last few years there has been increased interest in their application for anaerobic processes. This paper presents the results obtained when a bench-scale submerged anaerobic membrane bioreactor was used for the treatment of wastewaters generated in the agro-food industry. The reactor was fed with synthetic wastewater consisting of cheese whey and sucrose, and volumetric organic loading rates (OLRs) ranging from 1.5 to 13 kgCOD/(m3*d) were applied. Under the operating conditions studied, the maximum applicable OLR was between 6 and 10 gCOD/(g*L), which fell within the ranges of the high-rate anaerobic wastewater treatment systems, while high concentrations of volatile fatty acids were produced at higher OLR rates. With an OLR of 1.5–10 gCOD/(g*L), the reactor showed 94% COD removal, whereas this value dropped to 33% with the highest applied OLR of 13 gCOD/(g*L). The study therefore confirms that membrane bioreactors can be used for anaerobic wastewater treatment.
- 1 February 2009
- Published by Elsevier in Desalination
- Vol. 237 (1-3) , 190-200
Start-up of a pilot-scale membrane bioreactor to treat municipal wastewater
- 1 February 2009
- Published by Elsevier in Desalination
- Vol. 237 (1-3) , 190-200
Start-up of a pilot-scale membrane bioreactor to treat municipal wastewater