Alireza Ghafouri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Alireza Ghafouri has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Hamed Babanezhaad Shirdar
Islamic Azad University, Sari Branch
2 shared publications - Mohsen Sedighi
Department of Electrical Engineering, Sar.C., Islamic Azad University, Sari, Iran
2 shared publications - Tohid Nouri
Department of Electrical Engineering, Sar.C., Islamic Azad University, Sari, Iran
2 shared publications - Ali Goudarzi Amlashi
Department of Electrical Engineering, Azad University, Sari Branch, Sari, Iran
1 shared publication - Ebrahim Razaghi Ghadikolaei
Department of Electrical Engineering, Sari Branch, Islamic Azad University, Sari, Iran
1 shared publication - Gevork Babamalek Gharehpetian
Amirkabir University of Technology
1 shared publication
Latest Publications
- 31 July 2026
- Published by Springer Nature in Electrical Engineering
- Vol. 108 (8) , 350
MILP-based optimization of renewable energy integration in maritime ports using demand response and energy storage
- 31 July 2026
- Published by Springer Nature in Electrical Engineering
- Vol. 108 (8) , 350
MILP-based optimization of renewable energy integration in maritime ports using demand response and energy storage
- Open Access
- 1 January 2026
- Published by Wiley in International Journal of Energy Research
- Vol. 2026 (1)
A Hierarchical Control Framework for Maintaining Voltage and Frequency Stability in Islanded Microgrids
This paper proposes a novel multi‐layer hierarchical control method for voltage and frequency regulation in multi‐microgrid islanded power system. The proposed method is a two‐layer hierarchical hybrid control framework in which adaptive Type‐2 fuzzy logic control is used in the first layer for local voltage regulation, while centralized model predictive control (MPC) is employed in the second layer for system‐level frequency stabilization. The overall hybrid framework is optimized using the proposed Fuzzy Grey Wolf Optimizer (FGWO). The FGWO is employed to optimally tune the parameters of both control layers, including the membership function (MF) parameters, scaling factors, and PID gains of the adaptive Type‐II fuzzy controller, as well as the weighting coefficients of the MPC objective function, using two voltage‐ and frequency‐oriented objective functions. Simulations are conducted in four cases and 10 selected scenarios by the copula method and probability density functions (PDFs) and the results of the proposed control method are compared with MPC, Type II Fuzzy‐based Controller (T2F), and sliding mode control (SMC). Simulation results demonstrate that the proposed framework improves frequency regulation by 5.5%–26.4% and voltage regulation by 6.3%–32.8% across all investigated operating conditions. Under severe loading conditions, the load‐shedding mechanism effectively maintains system stability when available control resources become insufficient. Although renewable generation uncertainties slightly reduce the achievable performance gains, the proposed hierarchical control strategy consistently provides robust voltage and frequency regulation under all investigated scenarios.
- 1 January 2026
- Published by Wiley in International Journal of Energy Research
- Vol. 2026 (1)
Open AccessA Hierarchical Control Framework for Maintaining Voltage and Frequency Stability in Islanded Microgrids
This paper proposes a novel multi‐layer hierarchical control method for voltage and frequency regulation in multi‐microgrid islanded power system. The proposed method is a two‐layer hierarchical hybrid control framework in which adaptive Type‐2 fuzzy logic control is used in the first layer for local voltage regulation, while centralized model predictive control (MPC) is employed in the second layer for system‐level frequency stabilization. The overall hybrid framework is optimized using the proposed Fuzzy Grey Wolf Optimizer (FGWO). The FGWO is employed to optimally tune the parameters of both control layers, including the membership function (MF) parameters, scaling factors, and PID gains of the adaptive Type‐II fuzzy controller, as well as the weighting coefficients of the MPC objective function, using two voltage‐ and frequency‐oriented objective functions. Simulations are conducted in four cases and 10 selected scenarios by the copula method and probability density functions (PDFs) and the results of the proposed control method are compared with MPC, Type II Fuzzy‐based Controller (T2F), and sliding mode control (SMC). Simulation results demonstrate that the proposed framework improves frequency regulation by 5.5%–26.4% and voltage regulation by 6.3%–32.8% across all investigated operating conditions. Under severe loading conditions, the load‐shedding mechanism effectively maintains system stability when available control resources become insufficient. Although renewable generation uncertainties slightly reduce the achievable performance gains, the proposed hierarchical control strategy consistently provides robust voltage and frequency regulation under all investigated scenarios.
- Open Access
- 1 January 2024
- Published by Wiley in International Journal of Energy Research
- Vol. 2024 (1)
Innovative Type II Fuzzy‐Based Voltage–Frequency Controller for Isolated Microgrid Considering Load Shedding and Uncertainties
Isolated power systems face significant challenges in maintaining stable voltage and frequency, particularly under conditions of high variability and uncertainty in power supply and demand. Existing control methods, such as Type I fuzzy logic and P/F and Q/V droop control, often struggle with precision and response speed, leading to issues such as frequency deviation and voltage instability. To address these challenges, this paper proposes a novel, fast voltage–frequency control (VFC) method specifically designed for isolated power systems. The proposed VFC method leverages battery charging control and consists of two main components: a load shedding unit and an interval type II fuzzy logic system. The load shedding unit plays a critical role in maintaining system stability by strategically disconnecting a portion of flexible loads involved in a demand response program (DRP) for brief periods when system parameters approach critical thresholds. This preemptive approach helps prevent destabilizing fluctuations and maintains operational integrity. In parallel, the interval type II fuzzy logic system significantly enhances the precision of voltage and frequency stabilization, especially in the face of uncertain and dynamic conditions. The control mechanism employs a roulette wheel selection process to choose scenarios based on probability density functions (PDFs), which are then optimized using the modified dynamic parameter bald eagle algorithm (MDP‐BES). This ensures robust performance across a wide range of scenarios. Comprehensive simulations were conducted across 20 scenarios in three sections to validate the effectiveness of the proposed method. Comparative analysis with Type I fuzzy logic control and traditional P/F and Q/V droop control methods demonstrated that the new VFC approach offers superior performance. Notably, it achieves higher accuracy and faster response times, with minimal voltage and frequency ripple during stable system operation. Additionally, the simulations revealed that scheduled load shedding within the system leads to a 15% reduction in frequency deviation and a 10% reduction in voltage deviation, highlighting the significant improvements over existing control strategies.
- 1 January 2024
- Published by Wiley in International Journal of Energy Research
- Vol. 2024 (1)
Open AccessInnovative Type II Fuzzy‐Based Voltage–Frequency Controller for Isolated Microgrid Considering Load Shedding and Uncertainties
Isolated power systems face significant challenges in maintaining stable voltage and frequency, particularly under conditions of high variability and uncertainty in power supply and demand. Existing control methods, such as Type I fuzzy logic and P/F and Q/V droop control, often struggle with precision and response speed, leading to issues such as frequency deviation and voltage instability. To address these challenges, this paper proposes a novel, fast voltage–frequency control (VFC) method specifically designed for isolated power systems. The proposed VFC method leverages battery charging control and consists of two main components: a load shedding unit and an interval type II fuzzy logic system. The load shedding unit plays a critical role in maintaining system stability by strategically disconnecting a portion of flexible loads involved in a demand response program (DRP) for brief periods when system parameters approach critical thresholds. This preemptive approach helps prevent destabilizing fluctuations and maintains operational integrity. In parallel, the interval type II fuzzy logic system significantly enhances the precision of voltage and frequency stabilization, especially in the face of uncertain and dynamic conditions. The control mechanism employs a roulette wheel selection process to choose scenarios based on probability density functions (PDFs), which are then optimized using the modified dynamic parameter bald eagle algorithm (MDP‐BES). This ensures robust performance across a wide range of scenarios. Comprehensive simulations were conducted across 20 scenarios in three sections to validate the effectiveness of the proposed method. Comparative analysis with Type I fuzzy logic control and traditional P/F and Q/V droop control methods demonstrated that the new VFC approach offers superior performance. Notably, it achieves higher accuracy and faster response times, with minimal voltage and frequency ripple during stable system operation. Additionally, the simulations revealed that scheduled load shedding within the system leads to a 15% reduction in frequency deviation and a 10% reduction in voltage deviation, highlighting the significant improvements over existing control strategies.
- Open Access
- 1 January 2024
- Published by Wiley in International Journal of Energy Research
- Vol. 2024 (1)
Probabilistic Energy Management of DGs and Electric Vehicle Parking Lots in a Smart Grid considering Demand Response
In this paper, a novel model of an energy management system (EMS) for a microgrid (MG) under uncertain conditions is proposed. The MG consists of renewable photovoltaic and wind sources along with electric vehicle parking lots. Hence, the model incorporates the uncertainties of renewable DGs, parking lots, and also load. In this study, the MG operation cost and voltage stability index are considered objective functions. A novel combined algorithm (hMOPSO‐HS) is proposed for microgrid energy management. The hMOPSO‐HS algorithm is a combination of the mutant multiobjective particle swarm optimization (MOPSO) algorithm and the harmony search (HS) algorithm. The simulations are performed in two parts, with and without considering the uncertainty. The comparative analysis involves evaluating the optimization outcomes achieved by the hMOPSO‐HS algorithm in contrast to various other metaheuristic algorithms for multiobjective optimization. The simulation findings validate the superior efficacy of the hMOPSO‐HS algorithm compared to other approaches. Also, the simulation results showed that in the conditions of uncertainty, the operating cost is 6.1% higher and the microgrid stability index is 6.8% lower. Also, considering the uncertainty has caused the penalty for energy not supplied (ENS) and demand response program (DRP) costs to increase by 3% and 4%, respectively.
- 1 January 2024
- Published by Wiley in International Journal of Energy Research
- Vol. 2024 (1)
Open AccessProbabilistic Energy Management of DGs and Electric Vehicle Parking Lots in a Smart Grid considering Demand Response
In this paper, a novel model of an energy management system (EMS) for a microgrid (MG) under uncertain conditions is proposed. The MG consists of renewable photovoltaic and wind sources along with electric vehicle parking lots. Hence, the model incorporates the uncertainties of renewable DGs, parking lots, and also load. In this study, the MG operation cost and voltage stability index are considered objective functions. A novel combined algorithm (hMOPSO‐HS) is proposed for microgrid energy management. The hMOPSO‐HS algorithm is a combination of the mutant multiobjective particle swarm optimization (MOPSO) algorithm and the harmony search (HS) algorithm. The simulations are performed in two parts, with and without considering the uncertainty. The comparative analysis involves evaluating the optimization outcomes achieved by the hMOPSO‐HS algorithm in contrast to various other metaheuristic algorithms for multiobjective optimization. The simulation findings validate the superior efficacy of the hMOPSO‐HS algorithm compared to other approaches. Also, the simulation results showed that in the conditions of uncertainty, the operating cost is 6.1% higher and the microgrid stability index is 6.8% lower. Also, considering the uncertainty has caused the penalty for energy not supplied (ENS) and demand response program (DRP) costs to increase by 3% and 4%, respectively.
- Open Access
- 31 December 2022
- Published by Hindawi Limited in Computational Intelligence and Neuroscience
- Vol. 2022, 1-13
Optimizing Adaptive Disturbance Rejection Control Models Using the Chimp Optimization Algorithm for Ships’ Hybrid Renewable Energy Systems
Hybrid renewable energy systems are becoming widely prevalent in warships due to their reliability and acceptability. However, the uncertainty caused by using renewable energy resources is one of the primary challenges. Therefore, this paper investigates the implementation of a dynamic voltage restorer (DVR) with a new control strategy in a hybrid solar power generation system, including photovoltaic (PV) panels, diesel generators, battery storage, and conventional and sensitive loads. Furthermore, a new metaheuristic-based active disturbance rejection control (ADRC) strategy for fast and accurate DVR control is proposed. In this regard, a novel chimp optimization algorithm (ChOA)-based (i.e., ChOA-ADRC) strategy is suggested to increase the stability and robustness of the aforementioned hybrid system. The ADRC controller’s parameters are updated in real-time using the ChOA approach as an automatic tuning mechanism. In order to evaluate the performance of the proposed control strategy, the model is evaluated under two and three-phase fault case scenarios. Also, a comparison with the conventional PI controller has been performed to further evaluate the proposed method. Simulation findings reveal the suggested control strategy’s remarkable effectiveness in correcting fault-caused voltage drop and maintaining sensitive load voltage. Additionally, the results show that ChOA-ADRC presents a better dynamic response compared to conventional control strategies and increases the reliability of the hybrid power generation system.
- 31 December 2022
- Published by Hindawi Limited in Computational Intelligence and Neuroscience
- Vol. 2022, 1-13
Open AccessOptimizing Adaptive Disturbance Rejection Control Models Using the Chimp Optimization Algorithm for Ships’ Hybrid Renewable Energy Systems
Hybrid renewable energy systems are becoming widely prevalent in warships due to their reliability and acceptability. However, the uncertainty caused by using renewable energy resources is one of the primary challenges. Therefore, this paper investigates the implementation of a dynamic voltage restorer (DVR) with a new control strategy in a hybrid solar power generation system, including photovoltaic (PV) panels, diesel generators, battery storage, and conventional and sensitive loads. Furthermore, a new metaheuristic-based active disturbance rejection control (ADRC) strategy for fast and accurate DVR control is proposed. In this regard, a novel chimp optimization algorithm (ChOA)-based (i.e., ChOA-ADRC) strategy is suggested to increase the stability and robustness of the aforementioned hybrid system. The ADRC controller’s parameters are updated in real-time using the ChOA approach as an automatic tuning mechanism. In order to evaluate the performance of the proposed control strategy, the model is evaluated under two and three-phase fault case scenarios. Also, a comparison with the conventional PI controller has been performed to further evaluate the proposed method. Simulation findings reveal the suggested control strategy’s remarkable effectiveness in correcting fault-caused voltage drop and maintaining sensitive load voltage. Additionally, the results show that ChOA-ADRC presents a better dynamic response compared to conventional control strategies and increases the reliability of the hybrid power generation system.
- 21 October 2022
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 50 (16-17) , 951-971
Optimization of Multi-microgrid System Operation Cost with Different Energy Management Tools in the Presence of Energy Storage System
— Given the increasing capacity of distributed generation and renewable resources, how to use this capacity and proper energy management will be a major challenge for low-capacity networks such as microgrids. With the help of peripherals tools, an arrangement can be made to achieve a more desirable result in the energy management system (EMS). Storage resources and at a higher level, the storage module is used as one of these tools in the subsystems of the EMS. In this article, in addition to taking advantage of the connection of several microgrids to each other and reducing interactions with the main network, by using the storage module and other related tools, the cost of providing energy to a cluster of microgrids is reduced to the lowest possible value. By implementing a mathematical model based on mixed-integer linear programming, the best program for generation resources obtains in such a way that the cost of energy supply reduces to the minimum value. The study results have been analyzed in two case studies; a modified laboratory microgrid and the IEEE 33-bus distribution network. Although different solvers in Gams will provide almost similar answers, the optimal answer was found by the Cplex solver.
- 21 October 2022
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 50 (16-17) , 951-971
Optimization of Multi-microgrid System Operation Cost with Different Energy Management Tools in the Presence of Energy Storage System
— Given the increasing capacity of distributed generation and renewable resources, how to use this capacity and proper energy management will be a major challenge for low-capacity networks such as microgrids. With the help of peripherals tools, an arrangement can be made to achieve a more desirable result in the energy management system (EMS). Storage resources and at a higher level, the storage module is used as one of these tools in the subsystems of the EMS. In this article, in addition to taking advantage of the connection of several microgrids to each other and reducing interactions with the main network, by using the storage module and other related tools, the cost of providing energy to a cluster of microgrids is reduced to the lowest possible value. By implementing a mathematical model based on mixed-integer linear programming, the best program for generation resources obtains in such a way that the cost of energy supply reduces to the minimum value. The study results have been analyzed in two case studies; a modified laboratory microgrid and the IEEE 33-bus distribution network. Although different solvers in Gams will provide almost similar answers, the optimal answer was found by the Cplex solver.
- 25 March 2022
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 17 (7) , 986-996
Increasing the Accessibility of Rural Microgrid's Load to Resources in Multi‐Microgrid System with Considering Minimum Operation Cost
In rural areas due to the low capacity of resources on the one hand and the increase in demand, on the other hand, the use of load management will be a little different. In this paper, load energy management programs considering three modes are used to minimize the cost of operating a rural multi‐microgrid system and increase the accessibility of its controllable load. Consumers in this paper are divided into two sets of controllable and uncontrollable loads, and microgrids will respond economically to the energy management system due to the capacity of renewable resources and distributed generation. Consumption coordination in the form of an optimization program with a mixed‐integer nonlinear programming mathematical model is designed to reduce the overall operating costs in the microgrid. For microgrid's lowest cost, three different scenarios including only the use of uncontrollable loads, simultaneous use of uncontrollable and controllable loads, and the use of adjustable generation sources with considering generation ceiling of distributed generation have been used. Simulations have been performed in different scenarios in a modified IEEE 33 bus system in the GAMS environment with different solvers to achieve the best response, which shows a significant reduction by LINDO and DECOPT solver. © 2022 Institute of Electrical Engineers of Japan. Published by Wiley Periodicals LLC.
- 25 March 2022
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 17 (7) , 986-996
Increasing the Accessibility of Rural Microgrid's Load to Resources in Multi‐Microgrid System with Considering Minimum Operation Cost
In rural areas due to the low capacity of resources on the one hand and the increase in demand, on the other hand, the use of load management will be a little different. In this paper, load energy management programs considering three modes are used to minimize the cost of operating a rural multi‐microgrid system and increase the accessibility of its controllable load. Consumers in this paper are divided into two sets of controllable and uncontrollable loads, and microgrids will respond economically to the energy management system due to the capacity of renewable resources and distributed generation. Consumption coordination in the form of an optimization program with a mixed‐integer nonlinear programming mathematical model is designed to reduce the overall operating costs in the microgrid. For microgrid's lowest cost, three different scenarios including only the use of uncontrollable loads, simultaneous use of uncontrollable and controllable loads, and the use of adjustable generation sources with considering generation ceiling of distributed generation have been used. Simulations have been performed in different scenarios in a modified IEEE 33 bus system in the GAMS environment with different solvers to achieve the best response, which shows a significant reduction by LINDO and DECOPT solver. © 2022 Institute of Electrical Engineers of Japan. Published by Wiley Periodicals LLC.
- Open Access
- 12 October 2021
- Published by SAGE Publications in Wind Engineering
- Vol. 46 (3) , 767-779
Microgrid modeling for contribution to the frequency control of power system
Recently, Distributed Energy Resources (DERs) are becoming more attractive to supply local loads under the concept of microgrids. These new parts of the power system have basically different dynamics compared with conventional power plants. Most of them are connected to the grid by power electronic interfaces, and their dynamic is determined by their controller. In this paper, the effect of the increased penetration of DERs on the load frequency problem of power systems is studied. The DERs of microgrids in each area are controlled to change their active power at Point of Common Coupling (PCC) after a disturbance in the power system. It is shown that with appropriate control of DERs in microgrids, the frequency deviation of the power system will decrease and the stability margin can be increased.
- 12 October 2021
- Published by SAGE Publications in Wind Engineering
- Vol. 46 (3) , 767-779
Open AccessMicrogrid modeling for contribution to the frequency control of power system
Recently, Distributed Energy Resources (DERs) are becoming more attractive to supply local loads under the concept of microgrids. These new parts of the power system have basically different dynamics compared with conventional power plants. Most of them are connected to the grid by power electronic interfaces, and their dynamic is determined by their controller. In this paper, the effect of the increased penetration of DERs on the load frequency problem of power systems is studied. The DERs of microgrids in each area are controlled to change their active power at Point of Common Coupling (PCC) after a disturbance in the power system. It is shown that with appropriate control of DERs in microgrids, the frequency deviation of the power system will decrease and the stability margin can be increased.
- 17 March 2021
- Published by SAGE Publications in Wind Engineering
- Vol. 46 (1) , 34-51
Design of hybrid multilayer systems to improve energy management system in multi-microgrid systems in the presence of wind and solar power
Connecting microgrids has some benefits such as operation cost reduction and increasing sales revenue of their owners. To exploit these benefits, an energy management system with diverse and efficient capabilities is required. In this paper, a multi-layer system has been proposed to improve the energy management system in multi-microgrid systems. The purpose of the multilayer system is to optimize the cost of energy supply for the producer with the ability to activate one or more layers to improve the energy management system. Layers are modules that may contain the data required for optimization, like generation volume, load consumption, and operational plan. The appropriate mathematical model of the proposed seven-layer structure is used to optimize the operation cost of the multi-microgrid system. To verify the performance of the energy management system, the proposed method is implemented by GAMS and MATLAB software and the results are analyzed for a sample multi-microgrid system.
- 17 March 2021
- Published by SAGE Publications in Wind Engineering
- Vol. 46 (1) , 34-51
Design of hybrid multilayer systems to improve energy management system in multi-microgrid systems in the presence of wind and solar power
Connecting microgrids has some benefits such as operation cost reduction and increasing sales revenue of their owners. To exploit these benefits, an energy management system with diverse and efficient capabilities is required. In this paper, a multi-layer system has been proposed to improve the energy management system in multi-microgrid systems. The purpose of the multilayer system is to optimize the cost of energy supply for the producer with the ability to activate one or more layers to improve the energy management system. Layers are modules that may contain the data required for optimization, like generation volume, load consumption, and operational plan. The appropriate mathematical model of the proposed seven-layer structure is used to optimize the operation cost of the multi-microgrid system. To verify the performance of the energy management system, the proposed method is implemented by GAMS and MATLAB software and the results are analyzed for a sample multi-microgrid system.
- 3 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems Journal
- Vol. 12 (3) , 2772-2781
Fuzzy-Adaptive Frequency Control of Power System Including Microgrids, Wind Farms, and Conventional Power Plants
In this paper, the effect of the increased penetration of wind farms (WFs) and microgrids (MGs) on the frequency control of power systems is studied. WFs are responsible to contribute in load frequency control of power system by changing their injected electrical power. A new control method is proposed to utilize the kinetic energy of wind turbines to support system frequency, considering minimum speed of their rotor. Also, distributed energy resources of MGs, in each area, are controlled to change their active power and adjust the injected power at point of common coupling after a disturbance in the power system. A modified hierarchical coordinated control is used for the optimal control of the entire system. In the first level of this hierarchical control system, each area is optimized and in the second level (coordinator), interactions between areas are adjusted for the global optimization. The parameters of the controller are adaptively adjusted by a fuzzy controller for the best performance in different operating conditions. It is shown that using the proposed control system, the frequency deviations of the power system will decrease.
- 3 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems Journal
- Vol. 12 (3) , 2772-2781
Fuzzy-Adaptive Frequency Control of Power System Including Microgrids, Wind Farms, and Conventional Power Plants
In this paper, the effect of the increased penetration of wind farms (WFs) and microgrids (MGs) on the frequency control of power systems is studied. WFs are responsible to contribute in load frequency control of power system by changing their injected electrical power. A new control method is proposed to utilize the kinetic energy of wind turbines to support system frequency, considering minimum speed of their rotor. Also, distributed energy resources of MGs, in each area, are controlled to change their active power and adjust the injected power at point of common coupling after a disturbance in the power system. A modified hierarchical coordinated control is used for the optimal control of the entire system. In the first level of this hierarchical control system, each area is optimized and in the second level (coordinator), interactions between areas are adjusted for the global optimization. The parameters of the controller are adaptively adjusted by a fuzzy controller for the best performance in different operating conditions. It is shown that using the proposed control system, the frequency deviations of the power system will decrease.