Nikša Dulčić
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nikša Dulčić has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Ivica Pelivan
Department of Removable Prosthodontics, School of Dental Medicine, University of Zagreb, HR-10000 Zagreb, Croatia
5 shared publications - Samir Čimić
University of Zagreb
5 shared publications Josip Pandurić
4 shared publications- Gordana Laskarin
Department of Physiology, Immunology and Pathophysiology, Faculty of Medicine, University of Rijeka, Braće Branchetta 20, 51000 Rijeka, Croatia
3 shared publications Sonja Kraljević
3 shared publications- Tatjana Kehler
Hospital for Medical Rehabilitation of Hearth and Lung Diseases and Rheumatis “Thalassotherapia-Opatija”, M. Tita 180, 51410 Opatija, Croatia
3 shared publications
Latest Publications
- Open Access
- 13 February 2026
- Published by MDPI AG in Biomedicines
- Vol. 14 (2) , 424
Diagnostic Accuracy of Interleukin-17A for Internal Derangements of Temporomandibular Joints in Patients with Spondyloarthritis
Objective: The oral cavity is the beginning of the digestive tract and the composition of saliva could indicate immune events in the gut and joints. The objective of this research was to evaluate the diagnostic accuracy of salivary interleukin (IL)-17A for temporomandibular joint (TMJ) internal derangements (IDs) in patients with spondyloarthritis (SpA). Methods: SpA disease activity was assessed using the Bath Ankylosing Disease Activity Index (BASDAI), Ankylosing Spondylitis Disease Activity Score (ASDAS) and Disease Activity Index for Psoriatic Arthritis (DAPSA). Salivary cytokines were analyzed using enzyme-linked immunosorbent assay. TMJ conditions were evaluated using The Diagnostic Criteria for Temporomandibular Disorder (DC/TMD) protocol. A symptomatic TMJ-ID group with intracapsular arthralgia (n = 64) and asymptomatic TMJ-ID group without intracapsular arthralgia (n = 50), regardless of joint sounds, were compared with controls (healthy TMJs, n = 86). Results: Women were more prevalent and salivary IL-17A concentration was higher in both ID groups than in controls. Salivary IL-17A levels positively correlated with erythrocyte sedimentation rate, anti-streptolysin-O titer, salivary IL-12/23 p40 and matrix metalloproteinase-3 levels, sore and swollen joint counts, BASDAI, chronic TMJ pain and anxiety. IL-17A demonstrated diagnostic accuracy for currently symptomatic (cutoff, 11 pg/mL) and asymptomatic (cutoff, 11.6 pg/mL) TMJ-ID vs. controls. Patients with IL-17A levels above these cutoffs more frequently exhibited disc displacement with reduction and degenerative TMJ disease, higher self-reported spinal pain and higher SpA activity, as assessed by ASDAS, than patients with IL-17A levels ≤ cutoffs. TMJ-related headache and somatization contributed to greater TMJ pain in those with IL-17A > cutoffs, when compared with dichotomous controls. Conclusions: Salivary IL-17A concentration provides an accurate laboratory marker of SpA activity and enables the diagnosis of both currently symptomatic and asymptomatic TMJ-IDs in patients with SpA.
- 13 February 2026
- Published by MDPI AG in Biomedicines
- Vol. 14 (2) , 424
Open AccessDiagnostic Accuracy of Interleukin-17A for Internal Derangements of Temporomandibular Joints in Patients with Spondyloarthritis
Objective: The oral cavity is the beginning of the digestive tract and the composition of saliva could indicate immune events in the gut and joints. The objective of this research was to evaluate the diagnostic accuracy of salivary interleukin (IL)-17A for temporomandibular joint (TMJ) internal derangements (IDs) in patients with spondyloarthritis (SpA). Methods: SpA disease activity was assessed using the Bath Ankylosing Disease Activity Index (BASDAI), Ankylosing Spondylitis Disease Activity Score (ASDAS) and Disease Activity Index for Psoriatic Arthritis (DAPSA). Salivary cytokines were analyzed using enzyme-linked immunosorbent assay. TMJ conditions were evaluated using The Diagnostic Criteria for Temporomandibular Disorder (DC/TMD) protocol. A symptomatic TMJ-ID group with intracapsular arthralgia (n = 64) and asymptomatic TMJ-ID group without intracapsular arthralgia (n = 50), regardless of joint sounds, were compared with controls (healthy TMJs, n = 86). Results: Women were more prevalent and salivary IL-17A concentration was higher in both ID groups than in controls. Salivary IL-17A levels positively correlated with erythrocyte sedimentation rate, anti-streptolysin-O titer, salivary IL-12/23 p40 and matrix metalloproteinase-3 levels, sore and swollen joint counts, BASDAI, chronic TMJ pain and anxiety. IL-17A demonstrated diagnostic accuracy for currently symptomatic (cutoff, 11 pg/mL) and asymptomatic (cutoff, 11.6 pg/mL) TMJ-ID vs. controls. Patients with IL-17A levels above these cutoffs more frequently exhibited disc displacement with reduction and degenerative TMJ disease, higher self-reported spinal pain and higher SpA activity, as assessed by ASDAS, than patients with IL-17A levels ≤ cutoffs. TMJ-related headache and somatization contributed to greater TMJ pain in those with IL-17A > cutoffs, when compared with dichotomous controls. Conclusions: Salivary IL-17A concentration provides an accurate laboratory marker of SpA activity and enables the diagnosis of both currently symptomatic and asymptomatic TMJ-IDs in patients with SpA.
- Open Access
- 12 January 2026
- Published by MDPI AG in Dentistry Journal
- Vol. 14 (1) , 47
Occlusal Dysesthesia (Phantom Bite Syndrome): A Scoping Review
Background: Occlusal dysesthesia (OD), also known as phantom bite syndrome, is characterized by the subjective sensation of an uncomfortable or “wrong” bite despite the absence of objective occlusal pathology. This scoping review aimed to synthesize the current evidence on the epidemiology, etiology, clinical presentation, diagnosis, and management of OD. Methods: The PubMed, Google Scholar, Scopus, Web of Science, ScienceDirect, and Cochrane Library databases were systematically searched using the terms “phantom bite,” “occlusal dysesthesia,” “occlusal hyperawareness,” “occlusal hypervigilance,” “uncomfortable occlusion,” and “oral cenestopathy.” Studies were screened according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses criteria (2020), and evidence quality was assessed using the Oxford Center for Evidence-Based Medicine levels of evidence. Results: A total of 20 studies were included. OD predominantly affected middle-aged women, with symptom durations often exceeding several years, and was believed to be caused by disorderly central sensory processing or maladaptive signal processing rather than by a primary occlusal abnormality, with high rates of psychiatric comorbidities reported. Current evidence supports conservative multidisciplinary management, including patient education, cognitive behavioral therapy, and supportive pharmacotherapy, and irreversible dental interventions are contraindicated. Conclusions: OD is a complex biopsychosocial condition requiring multidisciplinary care. The current low-quality evidence is primarily obtained from case reports and case series. Therefore, high-quality controlled trials are urgently required to establish evidence-based diagnostic criteria and treatment protocols.
- 12 January 2026
- Published by MDPI AG in Dentistry Journal
- Vol. 14 (1) , 47
Open AccessOcclusal Dysesthesia (Phantom Bite Syndrome): A Scoping Review
Background: Occlusal dysesthesia (OD), also known as phantom bite syndrome, is characterized by the subjective sensation of an uncomfortable or “wrong” bite despite the absence of objective occlusal pathology. This scoping review aimed to synthesize the current evidence on the epidemiology, etiology, clinical presentation, diagnosis, and management of OD. Methods: The PubMed, Google Scholar, Scopus, Web of Science, ScienceDirect, and Cochrane Library databases were systematically searched using the terms “phantom bite,” “occlusal dysesthesia,” “occlusal hyperawareness,” “occlusal hypervigilance,” “uncomfortable occlusion,” and “oral cenestopathy.” Studies were screened according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses criteria (2020), and evidence quality was assessed using the Oxford Center for Evidence-Based Medicine levels of evidence. Results: A total of 20 studies were included. OD predominantly affected middle-aged women, with symptom durations often exceeding several years, and was believed to be caused by disorderly central sensory processing or maladaptive signal processing rather than by a primary occlusal abnormality, with high rates of psychiatric comorbidities reported. Current evidence supports conservative multidisciplinary management, including patient education, cognitive behavioral therapy, and supportive pharmacotherapy, and irreversible dental interventions are contraindicated. Conclusions: OD is a complex biopsychosocial condition requiring multidisciplinary care. The current low-quality evidence is primarily obtained from case reports and case series. Therefore, high-quality controlled trials are urgently required to establish evidence-based diagnostic criteria and treatment protocols.
- Open Access
- 26 November 2025
- Published by MDPI AG in Preprints.org
Occlusal Dysesthesia (Phantom Bite Syndrome): A Scoping Review
Background: Occlusal dysesthesia (OD), also known as phantom bite syndrome, is characterized by the subjective sensation of an uncomfortable or “wrong” bite despite the absence of objective occlusal pathology. This scoping review aimed to synthesize the current evidence on the epidemiology, etiology, clinical presentation, diagnosis, and management of OD. Methods: The PubMed, Google Scholar, Scopus, Web of Science, ScienceDirect, and Cochrane Library databases were systematically searched using the terms “phantom bite,” “occlusal dysesthesia,” “occlusal hyperawareness,” “occlusal hypervigilance,” “uncomfortable occlusion,” and “oral cenestopathy.” Studies were screened according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses criteria (2020), and evidence quality was assessed using the Oxford Center for Evidence-Based Medicine levels of evidence. Results: A total of 20 studies were included (one systematic review, two clinical guidelines, two case-control studies, one retrospective cohort study, two retrospective case series, six case reports, four narrative reviews, one survey, and one theoretical article). OD predominantly affected middle-aged women, with symptom durations often exceeding several years. OD is increasingly believed to be caused by disorderly central sensory processing or maladaptive signal processing rather than by a primary occlusal abnormality, and high rates of psychiatric comorbidities have been reported. Current evidence supports conservative multidisciplinary management approaches, including patient education, cognitive behavioral therapy, and supportive pharmacotherapy and strongly advises against irreversible dental interventions. Conclusions: OD is a complex biopsychosocial condition requiring multidisciplinary care. The current low-quality evidence is primarily obtained from case reports and case series. Therefore, high-quality controlled trials are urgently required to establish evidence-based diagnostic criteria and treatment protocols.
- 26 November 2025
- Published by MDPI AG in Preprints.org
Open AccessOcclusal Dysesthesia (Phantom Bite Syndrome): A Scoping Review
Background: Occlusal dysesthesia (OD), also known as phantom bite syndrome, is characterized by the subjective sensation of an uncomfortable or “wrong” bite despite the absence of objective occlusal pathology. This scoping review aimed to synthesize the current evidence on the epidemiology, etiology, clinical presentation, diagnosis, and management of OD. Methods: The PubMed, Google Scholar, Scopus, Web of Science, ScienceDirect, and Cochrane Library databases were systematically searched using the terms “phantom bite,” “occlusal dysesthesia,” “occlusal hyperawareness,” “occlusal hypervigilance,” “uncomfortable occlusion,” and “oral cenestopathy.” Studies were screened according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses criteria (2020), and evidence quality was assessed using the Oxford Center for Evidence-Based Medicine levels of evidence. Results: A total of 20 studies were included (one systematic review, two clinical guidelines, two case-control studies, one retrospective cohort study, two retrospective case series, six case reports, four narrative reviews, one survey, and one theoretical article). OD predominantly affected middle-aged women, with symptom durations often exceeding several years. OD is increasingly believed to be caused by disorderly central sensory processing or maladaptive signal processing rather than by a primary occlusal abnormality, and high rates of psychiatric comorbidities have been reported. Current evidence supports conservative multidisciplinary management approaches, including patient education, cognitive behavioral therapy, and supportive pharmacotherapy and strongly advises against irreversible dental interventions. Conclusions: OD is a complex biopsychosocial condition requiring multidisciplinary care. The current low-quality evidence is primarily obtained from case reports and case series. Therefore, high-quality controlled trials are urgently required to establish evidence-based diagnostic criteria and treatment protocols.
- Open Access
- 21 September 2025
- Published by MDPI AG in Dentistry Journal
- Vol. 13 (9) , 434
Temporomandibular Disorders in Professional Scuba Divers—A Cross-Sectional Study
Objectives: Most of the published literature on this topic argues about painful teeth, masticatory muscles, and/or temporomandibular joints in scuba divers. This study aimed to determine the possible differences in the prevalence of TMD between the diver population and the general population. Methods: This was a cross-sectional epidemiological study. The standardized RDC/TMD protocol was used for both the study and the control group. A total of 84 individuals were randomly selected to participate in the study: 55 divers (study group) and 29 individuals from the general population (control group). Results: There was a significant difference in the group 2 and group 3 RDC/TMD Axis I diagnoses between the study and the control group. Logistic regression analysis showed that the diver population was 15.8 times more likely to develop a group 2 left joint and 12 times more likely to develop a group 3 right joint diagnoses than the general population. The RDC/TMD Axis II diagnoses were also significantly higher in the study group than in the control group, whereby the divers were considerably older and predominantly male. Conclusions: A higher prevalence of group 2 (disk displacements) and group 3 (other common joint disorders) diagnoses was found in the divers. However, these results should be taken considering the limitation that there was a lack of age and gender matching between the groups, which can cause confounding.
- 21 September 2025
- Published by MDPI AG in Dentistry Journal
- Vol. 13 (9) , 434
Open AccessTemporomandibular Disorders in Professional Scuba Divers—A Cross-Sectional Study
Objectives: Most of the published literature on this topic argues about painful teeth, masticatory muscles, and/or temporomandibular joints in scuba divers. This study aimed to determine the possible differences in the prevalence of TMD between the diver population and the general population. Methods: This was a cross-sectional epidemiological study. The standardized RDC/TMD protocol was used for both the study and the control group. A total of 84 individuals were randomly selected to participate in the study: 55 divers (study group) and 29 individuals from the general population (control group). Results: There was a significant difference in the group 2 and group 3 RDC/TMD Axis I diagnoses between the study and the control group. Logistic regression analysis showed that the diver population was 15.8 times more likely to develop a group 2 left joint and 12 times more likely to develop a group 3 right joint diagnoses than the general population. The RDC/TMD Axis II diagnoses were also significantly higher in the study group than in the control group, whereby the divers were considerably older and predominantly male. Conclusions: A higher prevalence of group 2 (disk displacements) and group 3 (other common joint disorders) diagnoses was found in the divers. However, these results should be taken considering the limitation that there was a lack of age and gender matching between the groups, which can cause confounding.
- Open Access
- 15 March 2025
- Published by University of Zagreb School of Dental Medicine in Acta Stomatologica Croatica
- Vol. 59 (1) , 2-14
Temporomandibular Internal Derangements Denote Activity of Axial Spondyloarthritis
The group of spondyloarthritis (SpA) disorders shares common clinical manifestations, including internal derangement (ID) of temporomandibular joint (TMJ). This study aimed to investigate SpA activity in patients with ID of TMJ. We assessed 200 patients with neck pain using the Assessment of Spondyloarthritis International Society (ASAS) criteria. TMJ was examined using Diagnostic Criteria for Temporomandibular Disorders (DC/TMD protocol). Patients with SpA were divided into three groups: symptomatic ID of TMJ, asymptomatic ID of TMJ, or healthy TMJ (controls). Activity of SpA was evaluated using the Ankylosing Spondylitis Disease Activity Score (ASDAS), Bath Ankylosing Spondylitis Disease Activity Index (BASDAI), Disease Activity Index in Psoriatic Arthritis (DAPSA), patients' self-estimated SpA activity, difficulties in performing daily activities, pain intensity (visual analogue scale) and laboratory parameters. Patients with symptomatic and asymptomatic ID showed statistically significantly increased ASDAS, anti-streptolysin titer, patients' self-estimated axial pain and activity of SpA, and decreased hematocrit than the control. Patients with symptomatic ID also had statistically significant earlier onset of SpA, along with increased BASDAI and DAPSA, total body pain, difficulties in performing daily activities, platelet count, and serum alpha-amylase but lower hemoglobin concentration than controls. Patients with asymptomatic ID had higher frequencies of exacerbated axial SpA and sacroiliac joint ankylosis compared to the control. All patients with SpA and ID showed increased axial disease activity.
- 15 March 2025
- Published by University of Zagreb School of Dental Medicine in Acta Stomatologica Croatica
- Vol. 59 (1) , 2-14
Open AccessTemporomandibular Internal Derangements Denote Activity of Axial Spondyloarthritis
The group of spondyloarthritis (SpA) disorders shares common clinical manifestations, including internal derangement (ID) of temporomandibular joint (TMJ). This study aimed to investigate SpA activity in patients with ID of TMJ. We assessed 200 patients with neck pain using the Assessment of Spondyloarthritis International Society (ASAS) criteria. TMJ was examined using Diagnostic Criteria for Temporomandibular Disorders (DC/TMD protocol). Patients with SpA were divided into three groups: symptomatic ID of TMJ, asymptomatic ID of TMJ, or healthy TMJ (controls). Activity of SpA was evaluated using the Ankylosing Spondylitis Disease Activity Score (ASDAS), Bath Ankylosing Spondylitis Disease Activity Index (BASDAI), Disease Activity Index in Psoriatic Arthritis (DAPSA), patients' self-estimated SpA activity, difficulties in performing daily activities, pain intensity (visual analogue scale) and laboratory parameters. Patients with symptomatic and asymptomatic ID showed statistically significantly increased ASDAS, anti-streptolysin titer, patients' self-estimated axial pain and activity of SpA, and decreased hematocrit than the control. Patients with symptomatic ID also had statistically significant earlier onset of SpA, along with increased BASDAI and DAPSA, total body pain, difficulties in performing daily activities, platelet count, and serum alpha-amylase but lower hemoglobin concentration than controls. Patients with asymptomatic ID had higher frequencies of exacerbated axial SpA and sacroiliac joint ankylosis compared to the control. All patients with SpA and ID showed increased axial disease activity.
- Open Access
- 26 April 2023
- Published by MDPI AG in Prosthesis
- Vol. 5 (2) , 437-452
Radiological and Periodontal Evaluation of Stock and Custom CAD/CAM Implant Abutments—A One-Year Follow-Up Study
Implant abutment selection is an important step in implant treatment to restore one or more lost teeth. The aim of this study was to compare stock and individual CAD/CAM full-form abutments after one year in function. A total of 64 subjects with one missing tooth were divided into two groups according to the type of abutment: 34 patients were given a stock abutment, and 30 an individual CAD/CAM abutment. Patients were scheduled for check-ups seven days after functional loading and after four, eight, and twelve months. Peri-implant soft tissue status was checked at every check-up by monitoring parameters traditionally used in similar studies: plaque index; bleeding on probing; and probing depth. To assess the stability of the bone tissue, radiological methods of measuring the amount of bone level compared to the implant shoulder were used. When needed, data were analysed by χ2 test or by Fisher’s exact test. The normality of the distribution of quantitative measurements (properties) was tested by the Shapiro–Wilk test. Differences in the distribution of quantitative variables frequencies were analysed by Student’s t-test. Student’s t-test was used for repeated measurements, Mann–Whitney’s U test and ANOVA test for repeated measurements, and Friedmann’s two-way analysis of variance for repeated measurements. The predictive values of the chosen variables on the ABI index were assessed by the logistic regression model (Enter method). The results of this study showed that the impact of the abutment type (individual CAD/CAM or stock) on the average bleeding on probing was significant, especially after eight or twelve months. However, the abutment type did not show a significant correlation with the total crestal bone loss. The level of oral hygiene showed a significant correlation with the average bleeding on probing. The influence of smoking cigarettes on the total crestal bone loss evaluation was also significant. Overall, from a clinical perspective, custom CAD/CAM abutment performed slightly better than stock abutments during the one-year follow-up.
- 26 April 2023
- Published by MDPI AG in Prosthesis
- Vol. 5 (2) , 437-452
Open AccessRadiological and Periodontal Evaluation of Stock and Custom CAD/CAM Implant Abutments—A One-Year Follow-Up Study
Implant abutment selection is an important step in implant treatment to restore one or more lost teeth. The aim of this study was to compare stock and individual CAD/CAM full-form abutments after one year in function. A total of 64 subjects with one missing tooth were divided into two groups according to the type of abutment: 34 patients were given a stock abutment, and 30 an individual CAD/CAM abutment. Patients were scheduled for check-ups seven days after functional loading and after four, eight, and twelve months. Peri-implant soft tissue status was checked at every check-up by monitoring parameters traditionally used in similar studies: plaque index; bleeding on probing; and probing depth. To assess the stability of the bone tissue, radiological methods of measuring the amount of bone level compared to the implant shoulder were used. When needed, data were analysed by χ2 test or by Fisher’s exact test. The normality of the distribution of quantitative measurements (properties) was tested by the Shapiro–Wilk test. Differences in the distribution of quantitative variables frequencies were analysed by Student’s t-test. Student’s t-test was used for repeated measurements, Mann–Whitney’s U test and ANOVA test for repeated measurements, and Friedmann’s two-way analysis of variance for repeated measurements. The predictive values of the chosen variables on the ABI index were assessed by the logistic regression model (Enter method). The results of this study showed that the impact of the abutment type (individual CAD/CAM or stock) on the average bleeding on probing was significant, especially after eight or twelve months. However, the abutment type did not show a significant correlation with the total crestal bone loss. The level of oral hygiene showed a significant correlation with the average bleeding on probing. The influence of smoking cigarettes on the total crestal bone loss evaluation was also significant. Overall, from a clinical perspective, custom CAD/CAM abutment performed slightly better than stock abutments during the one-year follow-up.
- Top Cited Papers
- 9 April 2020
- Published by Wiley in Journal of Prosthodontics
- Vol. 29 (6) , 524-528
Comparison of Mechanical Properties of 3D‐Printed, CAD/CAM, and Conventional Denture Base Materials
Purpose: To evaluate and compare the mechanical properties (flexural strength and surface hardness) of different materials and technologies for denture base fabrication. The study emphasized the digital technologies of computer‐aided design/computer‐aided manufacturing (CAD/CAM) and three‐dimensional (3D) printing.Materials and Methods: A total of 160 rectangular specimens were fabricated from three conventional heat‐polymerized (ProBase Hot, Paladon 65, and Interacryl Hot), three CAD/CAM produced (IvoBase CAD, Interdent CC disc PMMA, and Polident CAD/CAM disc), one 3D‐printed (NextDent Base), and one polyamide material (Vertex ThermoSens) for denture base fabrication. The flexural strength test was the three‐point flexure test, while hardness testing was conducted using the Brinell method. The data were analyzed using descriptive and analytical statistics (α = 0.05).Results: During flexural testing, the IvoBase CAD and Vertex ThermoSens specimens did not fracture during loading. The flexural strength values of the other groups ranged from 71.7 ± 7.4 MPa to 111.9 ± 4.3 MPa. The surface hardness values ranged from 67.13 ± 10.64 MPa to 145.66 ± 2.22 MPa. There were significant differences between the tested materials for both flexural strength and surface hardness. There were also differences between some materials with the same polymerization type. CAD/CAM and polyamide materials had the highest flexural strength values. Two groups of CAD/CAM materials had the highest surface hardness values, while a third, along with the polyamide material, had the lowest. The 3D‐printed materials had the lowest flexural strength values.Conclusions: Generally, CAD/CAM materials show better mechanical properties than heat‐polymerized and 3D‐printed acrylics do. Nevertheless, a material's polymerization type is no guarantee of its optimal mechanical properties.
- 9 April 2020
- Published by Wiley in Journal of Prosthodontics
- Vol. 29 (6) , 524-528
Top Cited PapersComparison of Mechanical Properties of 3D‐Printed, CAD/CAM, and Conventional Denture Base Materials
Purpose: To evaluate and compare the mechanical properties (flexural strength and surface hardness) of different materials and technologies for denture base fabrication. The study emphasized the digital technologies of computer‐aided design/computer‐aided manufacturing (CAD/CAM) and three‐dimensional (3D) printing.Materials and Methods: A total of 160 rectangular specimens were fabricated from three conventional heat‐polymerized (ProBase Hot, Paladon 65, and Interacryl Hot), three CAD/CAM produced (IvoBase CAD, Interdent CC disc PMMA, and Polident CAD/CAM disc), one 3D‐printed (NextDent Base), and one polyamide material (Vertex ThermoSens) for denture base fabrication. The flexural strength test was the three‐point flexure test, while hardness testing was conducted using the Brinell method. The data were analyzed using descriptive and analytical statistics (α = 0.05).Results: During flexural testing, the IvoBase CAD and Vertex ThermoSens specimens did not fracture during loading. The flexural strength values of the other groups ranged from 71.7 ± 7.4 MPa to 111.9 ± 4.3 MPa. The surface hardness values ranged from 67.13 ± 10.64 MPa to 145.66 ± 2.22 MPa. There were significant differences between the tested materials for both flexural strength and surface hardness. There were also differences between some materials with the same polymerization type. CAD/CAM and polyamide materials had the highest flexural strength values. Two groups of CAD/CAM materials had the highest surface hardness values, while a third, along with the polyamide material, had the lowest. The 3D‐printed materials had the lowest flexural strength values.Conclusions: Generally, CAD/CAM materials show better mechanical properties than heat‐polymerized and 3D‐printed acrylics do. Nevertheless, a material's polymerization type is no guarantee of its optimal mechanical properties.
- Open Access
- 15 September 2019
- Published by University of Zagreb School of Dental Medicine in Acta Stomatologica Croatica
- Vol. 53 (3) , 213-223
Comparison of Parameters for Programming Adjustable Dental Articulators by Using Wax Eccentric Records and Arcus Digma Device
Objectives: Programming of joint mechanism/parameters (sagittal condylar inclination and Bennett angle) of adjustable dental articulators is a prerequisite for performing positions and movements of the mandible. The aim of the study was to test significant differences between the two methods (wax eccentric records and Arcus Digma device) of measuring these joint parameters by using three different dental articulators (SAM 3, Protar 7; and Artex CR). Materials and Methods: Thirty asymptomatic younger (age 25.7 +/- 2.9 years) subjects (dental medicine students) divided by gender, with normal occlusion (Angle class I) participated in the study. After taking anatomical impressions of both dental arches, master casts were made of hard dental plaster for each subject. The values of the left and right sagittal condylar inclination and Bennett angle by the two methods of wax eccentric protrusive and lateral records and Arcus Digma device were measured for the purpose of programming the mentioned joint parameters in three different articulator systems. Results: The average values of the measured parameters of sagittal condylar inclination and Bennett angle of wax eccentric records were higher (ranging from 5 degrees to 10 degrees) in relation to the values measured by Arcus Digma device. Statistically significant differences found between the measured joint parameters (p <0.025) were influenced by the articulator system design and measurement methods (t-test for dependent samples and MANOVA). Conclusion: The use of Arcus Digma device should be considered reliable and valid for individualized programming of dental articulators, rather than the use of wax eccentric records.
- 15 September 2019
- Published by University of Zagreb School of Dental Medicine in Acta Stomatologica Croatica
- Vol. 53 (3) , 213-223
Open AccessComparison of Parameters for Programming Adjustable Dental Articulators by Using Wax Eccentric Records and Arcus Digma Device
Objectives: Programming of joint mechanism/parameters (sagittal condylar inclination and Bennett angle) of adjustable dental articulators is a prerequisite for performing positions and movements of the mandible. The aim of the study was to test significant differences between the two methods (wax eccentric records and Arcus Digma device) of measuring these joint parameters by using three different dental articulators (SAM 3, Protar 7; and Artex CR). Materials and Methods: Thirty asymptomatic younger (age 25.7 +/- 2.9 years) subjects (dental medicine students) divided by gender, with normal occlusion (Angle class I) participated in the study. After taking anatomical impressions of both dental arches, master casts were made of hard dental plaster for each subject. The values of the left and right sagittal condylar inclination and Bennett angle by the two methods of wax eccentric protrusive and lateral records and Arcus Digma device were measured for the purpose of programming the mentioned joint parameters in three different articulator systems. Results: The average values of the measured parameters of sagittal condylar inclination and Bennett angle of wax eccentric records were higher (ranging from 5 degrees to 10 degrees) in relation to the values measured by Arcus Digma device. Statistically significant differences found between the measured joint parameters (p <0.025) were influenced by the articulator system design and measurement methods (t-test for dependent samples and MANOVA). Conclusion: The use of Arcus Digma device should be considered reliable and valid for individualized programming of dental articulators, rather than the use of wax eccentric records.
- 1 June 2019
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 121 (6) , 955-959
A study of the flexural strength and surface hardness of different materials and technologies for occlusal device fabrication
- 1 June 2019
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 121 (6) , 955-959
A study of the flexural strength and surface hardness of different materials and technologies for occlusal device fabrication