Sophia L. Bidinger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sophia L. Bidinger has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- George G. Malliaras
Department of Engineering, University of Cambridge, Cambridge, UK
4 shared publications - Scott Tom Keene
Rice University
3 shared publications - Adam Marks
Department of Materials Science and Engineering Stanford University Stanford California USA
2 shared publications Alberto Salleo
Department of Materials Science and Engineering Stanford University 94305 Stanford CA United States
2 shared publications- Flurin Eisner
Imperial College London
2 shared publications Guanchen Wu
Department of Physics and Centre for Processable Electronics Imperial College London SW7 2AZ London United Kingdom
2 shared publications
Latest Publications
- Open Access
- 23 December 2024
- Published by Wiley in Angewandte Chemie
- Vol. 137 (6)
The Influence of Alkyl Spacers and Molecular Weight on the Charge Transport and Storage Properties of Oxy‐Bithiophene‐Based Conjugated Polymers
Conjugated polymers (CPs) with polar side chains can conduct electronic and ionic charges simultaneously, making them promising for bioelectronics, electrocatalysis and energy storage. Recent work showed that adding alkyl spacers between CP backbones and polar side chains improved electronic charge carrier mobility, reduced swelling and enhanced stability, without compromising ion transport. However, how alkyl spacers impact polymer backbone conformation and, subsequently, electronic properties remain unclear. In this work, we design two oxy‐bithiophene‐based CP series, each featuring progressively extended alkyl spacer lengths and two distinct molecular weight (MW) distributions. Using operando characterisations, we evaluate the (spectro)electrochemical and swelling properties of the polymer thin films, and their performance in organic field‐effect transistors and organic electrochemical transistors. Surprisingly, alkyl spacers negatively impact the hole mobility of our polymers, with higher MW amplifying this effect. Using molecular dynamics simulations, we show that it is thermodynamically favourable for adjacent non‐polar alkyl spacers to aggregate in polar electrolytes, leading to backbone twisting. Further spectroscopic measurements corroborate this prediction. Our findings demonstrate the active interactions between side chain structure, MW and electrolyte/solvent polarity in influencing polymer performance, underscoring the importance of considering solvation environment effects on polymer conformation when designing new mixed conducting CPs for electrochemical applications.
- 23 December 2024
- Published by Wiley in Angewandte Chemie
- Vol. 137 (6)
Open AccessThe Influence of Alkyl Spacers and Molecular Weight on the Charge Transport and Storage Properties of Oxy‐Bithiophene‐Based Conjugated Polymers
Conjugated polymers (CPs) with polar side chains can conduct electronic and ionic charges simultaneously, making them promising for bioelectronics, electrocatalysis and energy storage. Recent work showed that adding alkyl spacers between CP backbones and polar side chains improved electronic charge carrier mobility, reduced swelling and enhanced stability, without compromising ion transport. However, how alkyl spacers impact polymer backbone conformation and, subsequently, electronic properties remain unclear. In this work, we design two oxy‐bithiophene‐based CP series, each featuring progressively extended alkyl spacer lengths and two distinct molecular weight (MW) distributions. Using operando characterisations, we evaluate the (spectro)electrochemical and swelling properties of the polymer thin films, and their performance in organic field‐effect transistors and organic electrochemical transistors. Surprisingly, alkyl spacers negatively impact the hole mobility of our polymers, with higher MW amplifying this effect. Using molecular dynamics simulations, we show that it is thermodynamically favourable for adjacent non‐polar alkyl spacers to aggregate in polar electrolytes, leading to backbone twisting. Further spectroscopic measurements corroborate this prediction. Our findings demonstrate the active interactions between side chain structure, MW and electrolyte/solvent polarity in influencing polymer performance, underscoring the importance of considering solvation environment effects on polymer conformation when designing new mixed conducting CPs for electrochemical applications.
- Open Access
- 23 December 2024
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 64 (6) , e202417897
The Influence of Alkyl Spacers and Molecular Weight on the Charge Transport and Storage Properties of Oxy‐Bithiophene‐Based Conjugated Polymers
Conjugated polymers (CPs) with polar side chains can conduct electronic and ionic charges simultaneously, making them promising for bioelectronics, electrocatalysis and energy storage. Recent work showed that adding alkyl spacers between CP backbones and polar side chains improved electronic charge carrier mobility, reduced swelling and enhanced stability, without compromising ion transport. However, how alkyl spacers impact polymer backbone conformation and, subsequently, electronic properties remain unclear. In this work, we design two oxy‐bithiophene‐based CP series, each featuring progressively extended alkyl spacer lengths and two distinct molecular weight (MW) distributions. Using operando characterisations, we evaluate the (spectro)electrochemical and swelling properties of the polymer thin films, and their performance in organic field‐effect transistors and organic electrochemical transistors. Surprisingly, alkyl spacers negatively impact the hole mobility of our polymers, with higher MW amplifying this effect. Using molecular dynamics simulations, we show that it is thermodynamically favourable for adjacent non‐polar alkyl spacers to aggregate in polar electrolytes, leading to backbone twisting. Further spectroscopic measurements corroborate this prediction. Our findings demonstrate the active interactions between side chain structure, MW and electrolyte/solvent polarity in influencing polymer performance, underscoring the importance of considering solvation environment effects on polymer conformation when designing new mixed conducting CPs for electrochemical applications.
- 23 December 2024
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 64 (6) , e202417897
Open AccessThe Influence of Alkyl Spacers and Molecular Weight on the Charge Transport and Storage Properties of Oxy‐Bithiophene‐Based Conjugated Polymers
Conjugated polymers (CPs) with polar side chains can conduct electronic and ionic charges simultaneously, making them promising for bioelectronics, electrocatalysis and energy storage. Recent work showed that adding alkyl spacers between CP backbones and polar side chains improved electronic charge carrier mobility, reduced swelling and enhanced stability, without compromising ion transport. However, how alkyl spacers impact polymer backbone conformation and, subsequently, electronic properties remain unclear. In this work, we design two oxy‐bithiophene‐based CP series, each featuring progressively extended alkyl spacer lengths and two distinct molecular weight (MW) distributions. Using operando characterisations, we evaluate the (spectro)electrochemical and swelling properties of the polymer thin films, and their performance in organic field‐effect transistors and organic electrochemical transistors. Surprisingly, alkyl spacers negatively impact the hole mobility of our polymers, with higher MW amplifying this effect. Using molecular dynamics simulations, we show that it is thermodynamically favourable for adjacent non‐polar alkyl spacers to aggregate in polar electrolytes, leading to backbone twisting. Further spectroscopic measurements corroborate this prediction. Our findings demonstrate the active interactions between side chain structure, MW and electrolyte/solvent polarity in influencing polymer performance, underscoring the importance of considering solvation environment effects on polymer conformation when designing new mixed conducting CPs for electrochemical applications.
- Open Access
- 16 November 2022
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 8 (46) , eadd4111
Pulsed transistor operation enables miniaturization of electrochemical aptamer-based sensors
By simultaneously transducing and amplifying, transistors offer advantages over simpler, electrode-based transducers in electrochemical biosensors. However, transistor-based biosensors typically use static (i.e., DC) operation modes that are poorly suited for sensor architectures relying on the modulation of charge transfer kinetics to signal analyte binding. Thus motivated, here, we translate the AC “pulsed potential” approach typically used with electrochemical aptamer-based (EAB) sensors to an organic electrochemical transistor (OECT). Specifically, by applying a linearly sweeping square-wave potential to an aptamer-functionalized gate electrode, we produce current modulation across the transistor channel two orders of magnitude larger than seen for the equivalent, electrode-based biosensor. Unlike traditional EAB sensors, our aptamer-based OECT (AB-OECT) sensors critically maintain output current even with miniaturization. The pulsed transistor operation demonstrated here could be applied generally to sensors relying on kinetics-based signaling, expanding opportunities for noninvasive and high spatial resolution biosensing.
- 16 November 2022
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 8 (46) , eadd4111
Open AccessPulsed transistor operation enables miniaturization of electrochemical aptamer-based sensors
By simultaneously transducing and amplifying, transistors offer advantages over simpler, electrode-based transducers in electrochemical biosensors. However, transistor-based biosensors typically use static (i.e., DC) operation modes that are poorly suited for sensor architectures relying on the modulation of charge transfer kinetics to signal analyte binding. Thus motivated, here, we translate the AC “pulsed potential” approach typically used with electrochemical aptamer-based (EAB) sensors to an organic electrochemical transistor (OECT). Specifically, by applying a linearly sweeping square-wave potential to an aptamer-functionalized gate electrode, we produce current modulation across the transistor channel two orders of magnitude larger than seen for the equivalent, electrode-based biosensor. Unlike traditional EAB sensors, our aptamer-based OECT (AB-OECT) sensors critically maintain output current even with miniaturization. The pulsed transistor operation demonstrated here could be applied generally to sensors relying on kinetics-based signaling, expanding opportunities for noninvasive and high spatial resolution biosensing.
- Open Access
- 14 February 2022
- Published by AIP Publishing in Applied Physics Letters
- Vol. 120 (7) , 073302
Highly stable PEDOT:PSS electrochemical transistors
Organic electrochemical transistors (OECTs) are a burgeoning biosensing transducer platform due to their intrinsic amplification, high transconductance, and biocompatibility. To be successful in real world biosensing applications, however, stable performance should be demonstrated to avoid false analyte readings that could lead to dangerous misdiagnosis. This work demonstrates the stability of carefully prepared OECTs using commercially available PEDOT:PSS as the channel layer. These devices exhibit more than 99% retention of the baseline current over 50 transfer curve cycles and, importantly, after several changes in electrolyte solution. Furthermore, impressive stability is demonstrated during continuous measurements of the drain current. These results show that PEDOT:PSS OECTs are ready for biosensing applications requiring accurate continuous monitoring.
- 14 February 2022
- Published by AIP Publishing in Applied Physics Letters
- Vol. 120 (7) , 073302
Open AccessHighly stable PEDOT:PSS electrochemical transistors
Organic electrochemical transistors (OECTs) are a burgeoning biosensing transducer platform due to their intrinsic amplification, high transconductance, and biocompatibility. To be successful in real world biosensing applications, however, stable performance should be demonstrated to avoid false analyte readings that could lead to dangerous misdiagnosis. This work demonstrates the stability of carefully prepared OECTs using commercially available PEDOT:PSS as the channel layer. These devices exhibit more than 99% retention of the baseline current over 50 transfer curve cycles and, importantly, after several changes in electrolyte solution. Furthermore, impressive stability is demonstrated during continuous measurements of the drain current. These results show that PEDOT:PSS OECTs are ready for biosensing applications requiring accurate continuous monitoring.
- Open Access
- 17 March 2021
- Published by Springer Nature in npj Flexible Electronics
- Vol. 5 (1) , 1-8
Sensorized tissue analogues enabled by a 3D-printed conductive organogel
State-of-the-art tissue analogues used in high-fidelity, hands-on medical simulation modules can deliver lifelike appearance and feel but lack the capability to provide quantified, real-time assessment of practitioner performance. The monolithic fabrication of hybrid printed/textile piezoresistive strain sensors in a realistic Y/V plasty suture training pad is demonstrated. A class of 3D-printable organogels comprised of inexpensive and nonhazardous feedstocks is used as the sensing medium, and conductive composite threads are used as the electrodes. These organogels are comprised of a glycol-based deep-eutectic solvent (DES) serving as the ionic conductor and 3-trimethoxysilylmethacrylate-capped fumed silica particles serving as the gelating agent. Rheology measurements reveal the influence of fumed silica particle capping group on the mixture rheology. Freestanding strain sensors demonstrate a maximum strain amplitude of 300%, negligible signal drift, a monotonic sensor response, a low degree of hysteresis, and excellent cyclic stability. The increased contact resistance of the conductive thread electrodes used in place of wire electrodes do not make a significant impact on sensor performance. This work showcases the potential of these organogels utilized in sensorized tissue analogues and freestanding strain sensors for widespread applications in medical simulation and education.
- 17 March 2021
- Published by Springer Nature in npj Flexible Electronics
- Vol. 5 (1) , 1-8
Open AccessSensorized tissue analogues enabled by a 3D-printed conductive organogel
State-of-the-art tissue analogues used in high-fidelity, hands-on medical simulation modules can deliver lifelike appearance and feel but lack the capability to provide quantified, real-time assessment of practitioner performance. The monolithic fabrication of hybrid printed/textile piezoresistive strain sensors in a realistic Y/V plasty suture training pad is demonstrated. A class of 3D-printable organogels comprised of inexpensive and nonhazardous feedstocks is used as the sensing medium, and conductive composite threads are used as the electrodes. These organogels are comprised of a glycol-based deep-eutectic solvent (DES) serving as the ionic conductor and 3-trimethoxysilylmethacrylate-capped fumed silica particles serving as the gelating agent. Rheology measurements reveal the influence of fumed silica particle capping group on the mixture rheology. Freestanding strain sensors demonstrate a maximum strain amplitude of 300%, negligible signal drift, a monotonic sensor response, a low degree of hysteresis, and excellent cyclic stability. The increased contact resistance of the conductive thread electrodes used in place of wire electrodes do not make a significant impact on sensor performance. This work showcases the potential of these organogels utilized in sensorized tissue analogues and freestanding strain sensors for widespread applications in medical simulation and education.