Eduardo dos Santos Funcia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Eduardo dos Santos Funcia has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Jorge Andrey Wilhelms Gut
Department of Chemical Engineering, Universidade de São Paulo, São Paulo 05508-010, SP, Brazil
5 shared publications - Érica Sayuri Siguemoto
Department of Chemical Engineering, Escola Politécnica, University of São Paulo, 05508-080 São Paulo, Brazil
3 shared publications - Galo Antonio Carrillo Le Roux
University of São Paulo, Polytechnic School, São Paulo, São Paulo, Brazil
2 shared publications - José Luis de Paiva
University of São Paulo
2 shared publications - Marcelo Martins Seckler
University of São Paulo, Polytechnic School, São Paulo, São Paulo, Brazil
2 shared publications Marcos Neves Pires
Department of Chemical Engineering, Escola Politécnica University of São Paulo São Paulo Brazil
2 shared publications
Latest Publications
- Open Access
- 29 September 2026
- Published by Elsevier in SSRN Electronic Journal
Topology Optimization for Temperature Management in a Fluidized Bed with Solid Adsorbent Using a Surrogate Heat-Generation Model
Fluidized beds are attractive gas–solid contactors for temperature-swing adsorption carbon capture. However, the nature of $\text{CO}_2$ adsorption elevates bed temperature and degrades sorbent capacity, making thermal management a critical bottleneck. Although topology optimization (TO) can yield non-intuitive component geometries for enhanced transport phenomena, it has not yet been applied to gas–solid fluidized-bed adsorption systems. To bridge this gap, this work proposes a topology optimization framework to manage the inherent heat generation and improve the $\text{CO}_2$ capture capacity. Directly addressing the TO problem requires a transient Euler–Euler two-fluid model coupling continuity, momentum, non-isothermal energy balances for both phases, interphase drag, species transport, and adsorption kinetics. Nonlinearity and numerical instability render a direct solution to the TO problem prohibitive. This work relaxes the optimization problem by replacing the full physics with a reduced-physics TO framework using single-phase Navier–Stokes and energy equations, with an automatic-differentiation-aided adjoint method for sensitivity computation. The heat generation from the adsorption is retained in the reduced-physics model using a polynomial surrogate heat-source model trained via complete physics data. To verify performance, the optimized topology was mapped back into the Euler–Euler model and benchmarked against a conventional baseline composed of circular elements placed at the optimized centroids with matched perimeters. Transient multiphase simulations demonstrate that the optimized design achieves the highest heat dissipation and total $\text{CO}_2$ capture. Furthermore, the circular baseline retains most of these thermal gains, proving that the proposed reduced-physics framework not only yields optimal topologies but also provides spatial guidance for designing practical tubular heat sinks.- 29 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessTopology Optimization for Temperature Management in a Fluidized Bed with Solid Adsorbent Using a Surrogate Heat-Generation Model
Fluidized beds are attractive gas–solid contactors for temperature-swing adsorption carbon capture. However, the nature of $\text{CO}_2$ adsorption elevates bed temperature and degrades sorbent capacity, making thermal management a critical bottleneck. Although topology optimization (TO) can yield non-intuitive component geometries for enhanced transport phenomena, it has not yet been applied to gas–solid fluidized-bed adsorption systems. To bridge this gap, this work proposes a topology optimization framework to manage the inherent heat generation and improve the $\text{CO}_2$ capture capacity. Directly addressing the TO problem requires a transient Euler–Euler two-fluid model coupling continuity, momentum, non-isothermal energy balances for both phases, interphase drag, species transport, and adsorption kinetics. Nonlinearity and numerical instability render a direct solution to the TO problem prohibitive. This work relaxes the optimization problem by replacing the full physics with a reduced-physics TO framework using single-phase Navier–Stokes and energy equations, with an automatic-differentiation-aided adjoint method for sensitivity computation. The heat generation from the adsorption is retained in the reduced-physics model using a polynomial surrogate heat-source model trained via complete physics data. To verify performance, the optimized topology was mapped back into the Euler–Euler model and benchmarked against a conventional baseline composed of circular elements placed at the optimized centroids with matched perimeters. Transient multiphase simulations demonstrate that the optimized design achieves the highest heat dissipation and total $\text{CO}_2$ capture. Furthermore, the circular baseline retains most of these thermal gains, proving that the proposed reduced-physics framework not only yields optimal topologies but also provides spatial guidance for designing practical tubular heat sinks. - 19 June 2026
- Published by The CACHE Foundation, Inc.
- Vol. 6, 1183-1188
Energy Integration Via Heat Pump in a Simulated Fluidized TSA Column for CO2 Capture from Biomass-Derived Flue Gases
We present a steady-state, optimization-based techno-economic study of a continuous fluidized temperature-swing adsorption (TSA) system for post-combustion CO2 capture from biomass-derived flue gas, using two adsorption stages and one desorption stage with integrated heat-pump thermal management. The GAMS/CONOPT4 model couples molar and energy balances, Toth adsorption equilibrium, fluidized-bed hydrodynamics and literature cost correlations. Optimization yields CO2 purity of 96% v/v and 95.5% recovery at low, safe pressures with particle Reynolds numbers of 2-11, indicating near-minimum-fluidization operation. The nominal capture cost is 87 USD/tonCO2 with an internal rate of return of 42%; utilities comprise 49% of annualized costs and the adsorption compressor dominates equipment capital. Disabling the heat pump increases modeled capture cost to 124 USD/tonCO2, highlighting the heat pump’s decisive role in reducing energy demand and costs. Adding adsorption stages lowers modeled cost further but produces impractically shallow beds, revealing a trade-off between mass-transfer performance and feasible bed geometry. A sensitivity analysis demonstrated a linear positive correlation between electricity cost and capture cost, with capture costs potentially as low as 50 USD/tonCO2 and an internal rate of return as high as 64%. While results demonstrate the technical and economic plausibility of a heat-pump-assisted fluidized TSA under the stated assumptions, the study recommends including flue contaminants, refined heat-exchanger and pressure-drop models, and experimental validation for scale-up.
- 19 June 2026
- Published by The CACHE Foundation, Inc.
- Vol. 6, 1183-1188
Energy Integration Via Heat Pump in a Simulated Fluidized TSA Column for CO2 Capture from Biomass-Derived Flue Gases
We present a steady-state, optimization-based techno-economic study of a continuous fluidized temperature-swing adsorption (TSA) system for post-combustion CO2 capture from biomass-derived flue gas, using two adsorption stages and one desorption stage with integrated heat-pump thermal management. The GAMS/CONOPT4 model couples molar and energy balances, Toth adsorption equilibrium, fluidized-bed hydrodynamics and literature cost correlations. Optimization yields CO2 purity of 96% v/v and 95.5% recovery at low, safe pressures with particle Reynolds numbers of 2-11, indicating near-minimum-fluidization operation. The nominal capture cost is 87 USD/tonCO2 with an internal rate of return of 42%; utilities comprise 49% of annualized costs and the adsorption compressor dominates equipment capital. Disabling the heat pump increases modeled capture cost to 124 USD/tonCO2, highlighting the heat pump’s decisive role in reducing energy demand and costs. Adding adsorption stages lowers modeled cost further but produces impractically shallow beds, revealing a trade-off between mass-transfer performance and feasible bed geometry. A sensitivity analysis demonstrated a linear positive correlation between electricity cost and capture cost, with capture costs potentially as low as 50 USD/tonCO2 and an internal rate of return as high as 64%. While results demonstrate the technical and economic plausibility of a heat-pump-assisted fluidized TSA under the stated assumptions, the study recommends including flue contaminants, refined heat-exchanger and pressure-drop models, and experimental validation for scale-up.
- 1 March 2021
- Published by Elsevier in Food Chemistry
- Vol. 340, 127911
Inactivation of polyphenol oxidase by microwave and conventional heating: Investigation of thermal and non-thermal effects of focused microwaves
- 1 March 2021
- Published by Elsevier in Food Chemistry
- Vol. 340, 127911
Inactivation of polyphenol oxidase by microwave and conventional heating: Investigation of thermal and non-thermal effects of focused microwaves
- 1 October 2020
- Published by Elsevier in Current Opinion in Food Science
- Vol. 35, 36-48
Non-thermal effects of microwave and ohmic processing on microbial and enzyme inactivation: a critical review
- 1 October 2020
- Published by Elsevier in Current Opinion in Food Science
- Vol. 35, 36-48
Non-thermal effects of microwave and ohmic processing on microbial and enzyme inactivation: a critical review
- 16 June 2020
- Published by Springer Nature in Food and Bioprocess Technology
- Vol. 13 (7) , 1206-1214
Effect of Electric Field on Pectinesterase Inactivation During Orange Juice Pasteurization by Ohmic Heating
- 16 June 2020
- Published by Springer Nature in Food and Bioprocess Technology
- Vol. 13 (7) , 1206-1214
Effect of Electric Field on Pectinesterase Inactivation During Orange Juice Pasteurization by Ohmic Heating
- 21 October 2018
- Published by Wiley in Journal of Food Process Engineering
- Vol. 41 (8)
Evaluation and modeling of a microwave‐assisted unit for continuous flow pasteurization of liquid foods: Residence time distribution, time–temperature history, and integrated lethality
Focused microwave heaters have potential to replace heat exchangers in continuous flow pasteurization of liquid foods. The objective of this work was to evaluate a pilot scale unit used for microwave assisted pasteurization of low viscosity liquid foods in order to model the heat transfer and residence time distribution (RTD) to, subsequently, predict the average time–temperature history and estimate the level of heat treatment of the process and contributions from each step. RTD data using water showed that it was possible to assume plug‐flow (negligible axial dispersion). Heat transfer experiments using water provided heat transfer coefficients as functions of Reynolds number and microwave power absorption. Mathematical modeling was used to determine the temperature distribution along the product path, and results were validated. Integrated lethality calculated from the time–temperature histories (pasteurization at 70 °C) revealed the contribution of each process step. Results showed that focused microwave heating provided the necessary temperature increase in a very short time, with a lethality contribution of only 0.7% as compared to 59–68% when using only the conventional heat exchanger. The methods described can be useful for the evaluation of other continuous flow pasteurization units processing low viscosity liquid foods.Practical applications: The mathematical modeling approach and experimental methods presented herein can be used for the analysis of continuous flow pasteurization systems based on tubular heat exchangers and with low axial dispersion (plug flow), providing temperature and lethality distribution along the product path, showing the contribution from each section on inactivation. Specifically for the equipment used in the experiments, the obtained heat transfer and resident time distribution parameters will be useful to study the processing of low viscosity foods such as fruit juices and nectars on ongoing works from the group.
- 21 October 2018
- Published by Wiley in Journal of Food Process Engineering
- Vol. 41 (8)
Evaluation and modeling of a microwave‐assisted unit for continuous flow pasteurization of liquid foods: Residence time distribution, time–temperature history, and integrated lethality
Focused microwave heaters have potential to replace heat exchangers in continuous flow pasteurization of liquid foods. The objective of this work was to evaluate a pilot scale unit used for microwave assisted pasteurization of low viscosity liquid foods in order to model the heat transfer and residence time distribution (RTD) to, subsequently, predict the average time–temperature history and estimate the level of heat treatment of the process and contributions from each step. RTD data using water showed that it was possible to assume plug‐flow (negligible axial dispersion). Heat transfer experiments using water provided heat transfer coefficients as functions of Reynolds number and microwave power absorption. Mathematical modeling was used to determine the temperature distribution along the product path, and results were validated. Integrated lethality calculated from the time–temperature histories (pasteurization at 70 °C) revealed the contribution of each process step. Results showed that focused microwave heating provided the necessary temperature increase in a very short time, with a lethality contribution of only 0.7% as compared to 59–68% when using only the conventional heat exchanger. The methods described can be useful for the evaluation of other continuous flow pasteurization units processing low viscosity liquid foods.Practical applications: The mathematical modeling approach and experimental methods presented herein can be used for the analysis of continuous flow pasteurization systems based on tubular heat exchangers and with low axial dispersion (plug flow), providing temperature and lethality distribution along the product path, showing the contribution from each section on inactivation. Specifically for the equipment used in the experiments, the obtained heat transfer and resident time distribution parameters will be useful to study the processing of low viscosity foods such as fruit juices and nectars on ongoing works from the group.
- 1 September 2018
- Published by Elsevier in Food and Bioproducts Processing
- Vol. 111, 45-53
Modeling of time-temperature history and enzymatic inactivation of cloudy apple juice in continuous flow microwave assisted pasteurization
- 1 September 2018
- Published by Elsevier in Food and Bioproducts Processing
- Vol. 111, 45-53
Modeling of time-temperature history and enzymatic inactivation of cloudy apple juice in continuous flow microwave assisted pasteurization
- 1 May 2017
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 36, 173-181
Using ultrasound technology for the inactivation and thermal sensitization of peroxidase in green coconut water
- 1 May 2017
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 36, 173-181
Using ultrasound technology for the inactivation and thermal sensitization of peroxidase in green coconut water