Harry Budiman
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Harry Budiman has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Oman Zuas
Metrology in Chemistry Research Group, Research Centre for Metrology-Indonesian Institute of Sciences (Pusat Penelitian Metrologi – LIPI), Kawasan PUSPIPTEK, Building 456, Kelurahan Setu, 15314, Tangerang Selatan, Banten, INDONESIA
12 shared publications Muhammad Rizky Mulyana
Metrology in Chemistry Research Group, Research Centre for Metrology-Indonesian Institute of Sciences (Pusat Penelitian Metrologi – LIPI), Kawasan PUSPIPTEK, Building 456, Kelurahan Setu, 15314, Tangerang Selatan, Banten, INDONESIA
5 shared publicationsAyu Hindayani
Metrology in Chemistry Research Group, Research Centre for Metrology-Indonesian Institute of Sciences (Pusat Penelitian Metrologi – LIPI), Kawasan PUSPIPTEK, Building 456, Kelurahan Setu, 15314, Tangerang Selatan, Banten, INDONESIA
2 shared publicationsBernadus Herdi Sirenden
Metrology Industry Research Group, Research Centre for Metrology-Indonesian Institute of Sciences (Pusat Penelitian Metrologi – LIPI), Kawasan PUSPIPTEK, Building 420, Kelurahan Setu, 15314, Tangerang Selatan, Banten, INDONESIA
2 shared publicationsDyah Styarini
Metrology in Chemistry Research Group, Research Centre for Metrology-Indonesian Institute of Sciences (Pusat Penelitian Metrologi – LIPI), Kawasan PUSPIPTEK, Building 456, Kelurahan Setu, 15314, Tangerang Selatan, Banten, INDONESIA
2 shared publicationsFransiska Sri Herwahyu Krismastuti
Metrology in Chemistry Research Group, Research Centre for Metrology-Indonesian Institute of Sciences (Pusat Penelitian Metrologi – LIPI), Kawasan PUSPIPTEK, Building 456, Kelurahan Setu, 15314, Tangerang Selatan, Banten, INDONESIA
2 shared publications
Latest Publications
- 6 June 2024
- Published by Springer Nature in MAPAN
- Vol. 39 (4) , 787-798
Method Validation of Gas Chromatography and Stability Study for Analysis of Standard Gas Mixtures of Carbon Dioxide in Nitrogen Matrix
- 6 June 2024
- Published by Springer Nature in MAPAN
- Vol. 39 (4) , 787-798
Method Validation of Gas Chromatography and Stability Study for Analysis of Standard Gas Mixtures of Carbon Dioxide in Nitrogen Matrix
- Open Access
- 30 December 2021
- Published by Universitas Sultan Ageng Tirtayasa (ASCEE) in EduChemia: Jurnal Kimia dan Pendidikan
- Vol. 6 (2) , 159-171
Preparation of TiO2 Nanotube Using Anodization Method: Charactherization and Its Application for CO Sensor
Preparation of TiO2 Nanotube Using Anodization Method: Charactherization and Its Application for CO Sensor
- 30 December 2021
- Published by Universitas Sultan Ageng Tirtayasa (ASCEE) in EduChemia: Jurnal Kimia dan Pendidikan
- Vol. 6 (2) , 159-171
Open AccessPreparation of TiO2 Nanotube Using Anodization Method: Charactherization and Its Application for CO Sensor
Preparation of TiO2 Nanotube Using Anodization Method: Charactherization and Its Application for CO Sensor
- Open Access
- 1 June 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 536 (1) , 012006
Development of metrology for gas analysis at the Research Centre for Metrology-Indonesian Institutes of Sciences
Nowadays, in Indonesia, accurate and traceable of gas measurement data for product quality assurance, air environmental control and mitigation are demanding. The Research Centerfor Metrologi-Indonesian Institute of Sciences (RCM-LIPI) in accordance with its duties and functions as the National Metrology Institute (NMI) continues to strive to develop its capabilities in answering such needs. In this presentation, we present the recent development of metrology activities in the field of gas analysis at the RCM-LIPI which includes infrastructure development (laboratory and instrumentation for gas analysis), development of reference gas mixtures (RGMs), and dissemination of prepared gas reference materials to end-used (stakeholders).
- 1 June 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 536 (1) , 012006
Open AccessDevelopment of metrology for gas analysis at the Research Centre for Metrology-Indonesian Institutes of Sciences
Nowadays, in Indonesia, accurate and traceable of gas measurement data for product quality assurance, air environmental control and mitigation are demanding. The Research Centerfor Metrologi-Indonesian Institute of Sciences (RCM-LIPI) in accordance with its duties and functions as the National Metrology Institute (NMI) continues to strive to develop its capabilities in answering such needs. In this presentation, we present the recent development of metrology activities in the field of gas analysis at the RCM-LIPI which includes infrastructure development (laboratory and instrumentation for gas analysis), development of reference gas mixtures (RGMs), and dissemination of prepared gas reference materials to end-used (stakeholders).
- Open Access
- 26 February 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1153 (1) , 012031
GC with FI and PDHI detection for trace impurity analysis in bulk gases: a comparative evaluation
Some experimental problems challenge the users when using a GC equipped with FID or PDHID detector in the context of trace level impurity analysis in ultra high purity bulk gases. In this study, a comparative evaluation of GC-FID and GC-PDHID is conducted based on both author's experiment and literature review in terms of two technical aspects i.e., imitation and capability. Findings shows that both GC-FID and GC-PDHID reflect capability aspect through a pretty detection sensitivity and quantification at trace level of the impurity compounds. Regarding detectability range of compounds, the GC-FID has relatively lower than the GC-FID since the FID responds to only hydrocarbon-type impurity compound, while PDHID can detect almost any compound, except neon. In case of limitation aspect for these two instruments, detectable range of target compounds and operating cost are remarkable. In addition, in context of operating cost and maintenance, however, the FID is relatively inexpensive in comparison to that of PDHID. Besides aforementioned technical aspects, other capabilities and limitations of both FID and PDHID are also evaluated and compared.
- 26 February 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1153 (1) , 012031
Open AccessGC with FI and PDHI detection for trace impurity analysis in bulk gases: a comparative evaluation
Some experimental problems challenge the users when using a GC equipped with FID or PDHID detector in the context of trace level impurity analysis in ultra high purity bulk gases. In this study, a comparative evaluation of GC-FID and GC-PDHID is conducted based on both author's experiment and literature review in terms of two technical aspects i.e., imitation and capability. Findings shows that both GC-FID and GC-PDHID reflect capability aspect through a pretty detection sensitivity and quantification at trace level of the impurity compounds. Regarding detectability range of compounds, the GC-FID has relatively lower than the GC-FID since the FID responds to only hydrocarbon-type impurity compound, while PDHID can detect almost any compound, except neon. In case of limitation aspect for these two instruments, detectable range of target compounds and operating cost are remarkable. In addition, in context of operating cost and maintenance, however, the FID is relatively inexpensive in comparison to that of PDHID. Besides aforementioned technical aspects, other capabilities and limitations of both FID and PDHID are also evaluated and compared.
- Open Access
- 26 February 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1153 (1) , 012033
Validated method for trace impurities analysis in bulk gas using Gas Chromatography with Pulse Discharge Helium Ionization Detection
Pulse discharge helium ionization detector (PDHID) is developed to respond the need of many applications in the area of chromatographic quantitative analysis. The PDHID is a general type of detector with very high detectability property covering a wide range of chemical compounds. Based on ISO/IEC 17025, a reliable and accurate of measurement result can be obtained by applying a validated method. This paper reports a validation study with regard to the application of GC-PDHID for trace impurity analysis in bulk gases. An optimized operating condition of GC was used to evaluate the method performance with parameters including precision (repeatability and reproducibility), linearity, limit of detection (LoD), and limit of quantification (LoQ). In this study, six trace compounds (CO2, H2, Ar, O2, CH4, and CO) in bulk gas were analyzed. The results show that the validated of the GC-PDHID method was repeatable and reproducible for the analysis of trace impurities in bulk gas. The %RSD of repeatability and reproducibility were found to be < 3.00% and < 10.50%, respectively. Good linearity of the validated method was obtained with the correlation coefficient (R2) higher than 0.99 for all six trace compounds. In addition, the calculated LOD and LOQ of the GC-PDHID were found to be < 0.60 and < 2.00 μmol mol−1 respectively. In conclusion, validated method of the GC-PDHID for the measurement of the six trace compounds in bulk gas is reliable and fit for its purpose, implying that the validated method can be used in daily measurement in the testing laboratory.
- 26 February 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1153 (1) , 012033
Open AccessValidated method for trace impurities analysis in bulk gas using Gas Chromatography with Pulse Discharge Helium Ionization Detection
Pulse discharge helium ionization detector (PDHID) is developed to respond the need of many applications in the area of chromatographic quantitative analysis. The PDHID is a general type of detector with very high detectability property covering a wide range of chemical compounds. Based on ISO/IEC 17025, a reliable and accurate of measurement result can be obtained by applying a validated method. This paper reports a validation study with regard to the application of GC-PDHID for trace impurity analysis in bulk gases. An optimized operating condition of GC was used to evaluate the method performance with parameters including precision (repeatability and reproducibility), linearity, limit of detection (LoD), and limit of quantification (LoQ). In this study, six trace compounds (CO2, H2, Ar, O2, CH4, and CO) in bulk gas were analyzed. The results show that the validated of the GC-PDHID method was repeatable and reproducible for the analysis of trace impurities in bulk gas. The %RSD of repeatability and reproducibility were found to be < 3.00% and < 10.50%, respectively. Good linearity of the validated method was obtained with the correlation coefficient (R2) higher than 0.99 for all six trace compounds. In addition, the calculated LOD and LOQ of the GC-PDHID were found to be < 0.60 and < 2.00 μmol mol−1 respectively. In conclusion, validated method of the GC-PDHID for the measurement of the six trace compounds in bulk gas is reliable and fit for its purpose, implying that the validated method can be used in daily measurement in the testing laboratory.
- Open Access
- 26 February 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1153 (1) , 012073
Photo-electrochemical properties of TiOs2 nanotube arrays: effect of different polishing method of Ti substrate prior to anodization in fluoride-H2O2-containing electrolyte
The comparison of two pre-treatment methods, such as mechanical polishing and chemical polishing, prior to anodization of titanium surface in the ethylene glycol based electrolyte containing H 2O2, were carried out to investigate their effects on photoelectrochemical property of produced highly ordered TiO2 nanotube arrays (HOTNAs). The Tichemical polishing was conducted in electrolyte containing H2O2 (0.6% H2O2/1.4% H2O). The prepared HOTNAs were characterized by FT-IR, UV-Vis DRS and SEM. The obtained FTIR spectrum, showed vibration band at 1100 and 425 cm-1 , give strong indication on the existent of a-Ti-O-Ti-network. While from UV-Vis DRS spectra, the band gap of the fabricated HOTNAs were found in the range of 3.10-3.22 eV, which are characteristics for anatase phase. In addition, obtained SEM image indicates the existence of quite good ordered nanotube arrays morphology. Linear sweep voltammetry (LSV) measurement showed that the steady state photocurrent density of HOTNAs fabricated by Ti-chemical polishing were greater than that of prepared by Ti-mechanical polishing. The increasing of H2O2 content in electrolyte (1.5% H 2O2/3.5% H2O) affected to the enhancement of steady state photocurrent density of HOTNAs. Thus pre-treatment of the Ti foils using chemical polish method does enhance its photoelectrochemical property.
- 26 February 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1153 (1) , 012073
Open AccessPhoto-electrochemical properties of TiOs2 nanotube arrays: effect of different polishing method of Ti substrate prior to anodization in fluoride-H2O2-containing electrolyte
The comparison of two pre-treatment methods, such as mechanical polishing and chemical polishing, prior to anodization of titanium surface in the ethylene glycol based electrolyte containing H 2O2, were carried out to investigate their effects on photoelectrochemical property of produced highly ordered TiO2 nanotube arrays (HOTNAs). The Tichemical polishing was conducted in electrolyte containing H2O2 (0.6% H2O2/1.4% H2O). The prepared HOTNAs were characterized by FT-IR, UV-Vis DRS and SEM. The obtained FTIR spectrum, showed vibration band at 1100 and 425 cm-1 , give strong indication on the existent of a-Ti-O-Ti-network. While from UV-Vis DRS spectra, the band gap of the fabricated HOTNAs were found in the range of 3.10-3.22 eV, which are characteristics for anatase phase. In addition, obtained SEM image indicates the existence of quite good ordered nanotube arrays morphology. Linear sweep voltammetry (LSV) measurement showed that the steady state photocurrent density of HOTNAs fabricated by Ti-chemical polishing were greater than that of prepared by Ti-mechanical polishing. The increasing of H2O2 content in electrolyte (1.5% H 2O2/3.5% H2O) affected to the enhancement of steady state photocurrent density of HOTNAs. Thus pre-treatment of the Ti foils using chemical polish method does enhance its photoelectrochemical property.
- Open Access
- 26 February 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1153 (1) , 012035
Trace impurities measurement in ultra-high purity gases and their uncertainties: case study on permanent gas impurities in pure nitrogen
Trace measurement for gas impurities plays an important role in the quality determination of pure-gases. High purity gases will certainly have a higher economic value than gases with lower purity, especially for the ultra-high purity gases used in the preparation of standard gas mixtures. These types of gases shall have a maximum limit for their impurities, which should be verified by a validated method. In this study, an experiment was conducted to determine the impurities in three cylinders of ultra-high purity nitrogen (UHP N2) gases using a validated gas chromatography equipped with pulse dicharge helium ionization detector (GC-PDHID) method. The impurities detected by the GC-PDHID in the aforementioned UHP N2 samples consist of argon (Ar), oxygen (O2), methane (CH4), and carbon monoxide (CO). Meanwhile, hydrogen (H2) and carbon dioxide (CO2) cannot be seen on the chromatogram, then assumed to be lower than the PDHID's detection limit. Concentrations of the impurities, along with their uncertainties, were found to be 0.987 ± 0.104; 5.818 ± 0.807; 3.163 ± 0.449; and 1.289 ± 0.158 μmol/mol for Ar, O2, CH4, and CO, respectively for the first N2 cylinder. H2and CO2 were estimated to be half of the limit of detection, and H2O component was quoted from the UHP N2 manufacturer's certificate of analysis. The other two N2 cylinders showed almost similar amounts of impurities. Based on the results, the actual purity for each of the three N2 gases can be estimated as 99.9987% mol/mol; 99.9987% mol/mol; and 99.9988% mol/mol. It is expected that the results of this study could useful as reference for both pure-gas manufacturers and consumers to properly determine the quality of their products.
- 26 February 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1153 (1) , 012035
Open AccessTrace impurities measurement in ultra-high purity gases and their uncertainties: case study on permanent gas impurities in pure nitrogen
Trace measurement for gas impurities plays an important role in the quality determination of pure-gases. High purity gases will certainly have a higher economic value than gases with lower purity, especially for the ultra-high purity gases used in the preparation of standard gas mixtures. These types of gases shall have a maximum limit for their impurities, which should be verified by a validated method. In this study, an experiment was conducted to determine the impurities in three cylinders of ultra-high purity nitrogen (UHP N2) gases using a validated gas chromatography equipped with pulse dicharge helium ionization detector (GC-PDHID) method. The impurities detected by the GC-PDHID in the aforementioned UHP N2 samples consist of argon (Ar), oxygen (O2), methane (CH4), and carbon monoxide (CO). Meanwhile, hydrogen (H2) and carbon dioxide (CO2) cannot be seen on the chromatogram, then assumed to be lower than the PDHID's detection limit. Concentrations of the impurities, along with their uncertainties, were found to be 0.987 ± 0.104; 5.818 ± 0.807; 3.163 ± 0.449; and 1.289 ± 0.158 μmol/mol for Ar, O2, CH4, and CO, respectively for the first N2 cylinder. H2and CO2 were estimated to be half of the limit of detection, and H2O component was quoted from the UHP N2 manufacturer's certificate of analysis. The other two N2 cylinders showed almost similar amounts of impurities. Based on the results, the actual purity for each of the three N2 gases can be estimated as 99.9987% mol/mol; 99.9987% mol/mol; and 99.9988% mol/mol. It is expected that the results of this study could useful as reference for both pure-gas manufacturers and consumers to properly determine the quality of their products.
- 20 December 2017
- Published by Lviv Polytechnic National University in Chemistry & Chemical Technology
- Vol. 11 (4) , 420-429
Measurement of SF6 using gc-ecd: a comparative study on the utilization of CO2-N2 mixture and CH4-ar mixture as a make-up gas
- 20 December 2017
- Published by Lviv Polytechnic National University in Chemistry & Chemical Technology
- Vol. 11 (4) , 420-429
Measurement of SF6 using gc-ecd: a comparative study on the utilization of CO2-N2 mixture and CH4-ar mixture as a make-up gas
- Open Access
- 1 September 2016
- Published by Universidad Nacional de Colombia in Revista Colombiana de Química
- Vol. 45 (3) , 22-27
Analytical method validation of GC-FID for the simultaneous measurement of hydrocarbons (C2-C4) in their gas mixture
Se validó una cromatrografía de gases precisa, equipada con un detector de ionización de llama (GC-FID) para el análisis simultáneo de hidrocarburos ligeros (C2-C4) en su mezcla gaseosa. Los parámetros de validación se evaluaron con base en la definición de la ISO/IEC 17025, que incluye selectividad del método, precisión y repetibilidad, exactitud, linealidad, límite de detección (LOD), límite de cuantificación (LOQ) y robustez. Bajo las condiciones analíticas óptimas, el análisis de la mezcla gaseosa mostró que cada analito de interés fue separado adecuadamente con alta selectividad. Se encontró también que el método era preciso y exacto; la linealidad fue alta y con buen coeficiente de correlación lineal (R2 ≥ 0.999) para todos los analitos. Se puede concluir que el método GC-FID es confiable y apropiado para la determinación de hidrocarburos ligeros C2-C4 (incluyendo etileno, propano, propileno, isobutano y n-butano) en una mezcla gaseosa. El método validado ha sido exitosamente aplicado a la valoración de hidrocarburos ligeros C2-C4 en muestras de gas natural, mostrando alta repetibilidad con desviación estándar relativa (RDS) menor al 1% y buena selectividad sin interferencias de otros posibles componentes.
- 1 September 2016
- Published by Universidad Nacional de Colombia in Revista Colombiana de Química
- Vol. 45 (3) , 22-27
Open AccessAnalytical method validation of GC-FID for the simultaneous measurement of hydrocarbons (C2-C4) in their gas mixture
Se validó una cromatrografía de gases precisa, equipada con un detector de ionización de llama (GC-FID) para el análisis simultáneo de hidrocarburos ligeros (C2-C4) en su mezcla gaseosa. Los parámetros de validación se evaluaron con base en la definición de la ISO/IEC 17025, que incluye selectividad del método, precisión y repetibilidad, exactitud, linealidad, límite de detección (LOD), límite de cuantificación (LOQ) y robustez. Bajo las condiciones analíticas óptimas, el análisis de la mezcla gaseosa mostró que cada analito de interés fue separado adecuadamente con alta selectividad. Se encontró también que el método era preciso y exacto; la linealidad fue alta y con buen coeficiente de correlación lineal (R2 ≥ 0.999) para todos los analitos. Se puede concluir que el método GC-FID es confiable y apropiado para la determinación de hidrocarburos ligeros C2-C4 (incluyendo etileno, propano, propileno, isobutano y n-butano) en una mezcla gaseosa. El método validado ha sido exitosamente aplicado a la valoración de hidrocarburos ligeros C2-C4 en muestras de gas natural, mostrando alta repetibilidad con desviación estándar relativa (RDS) menor al 1% y buena selectividad sin interferencias de otros posibles componentes.