Mirjam Lenz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mirjam Lenz has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Nadim Joni Shah
Institute of Neuroscience and Medicine 4, INM-4, Forschungszentrum Jülich, Jülich, Germany
3 shared publications - Christoph W. Lerche
Institute of Neuroscience and Medicine, Forschungszentrum Jülich GmbH, Wilhelm-Johnen-Straße, Building 15.9, Office: 2001e, Jülich, 52428, GERMANY
2 shared publications Liliana Caldeira
Institute of Neuroscience and Medicine-4, Forschungszentrum Juelich, 52425 Juelich, Germany and Department for Diagnostic and Interventional Radiology, University Hospital Cologne, 50937 Cologne, Germany and Faculty of Mathematics and Natural Science, University of Wuppertal, 42119 Wuppertal, Germany
2 shared publicationsU. Pietrzyk
2 shared publicationsUwe Pietrzyk
Institute of Neuroscience and Medicine-4, Forschungszentrum Juelich, 52425 Juelich, Germany and Faculty of Mathematics and Natural Science, University of Wuppertal, 42119 Wuppertal, Germany
2 shared publicationsBo Ma
Forschungszentrum Julich, INM 4, Julich, Germany
1 shared publication
Latest Publications
- Open Access
Machine Learning-Based Radiomics Analysis for Identifying KRAS Mutations in Non-Small-Cell Lung Cancer from CT Images: Challenges, Insights and Implications
Kirsten Rat Sarcoma viral oncogene homolog (KRAS) is a frequently occurring mutation in non-small-cell lung cancer (NSCLC) and influences cancer treatment and disease progression. In this study, a machine learning (ML) pipeline was applied to radiomic features extracted from public and internal CT images to identify KRAS mutations in NSCLC patients. Both datasets were analyzed using parametric (t test) and non-parametric statistical tests (Mann–Whitney U test) and dimensionality reduction techniques. Afterwards, the proposed ML pipeline was applied to both datasets using a five-fold cross-validation on the training set (70/30 train/test split) before being validated on the other dataset. The results show that the radiomic features are significantly different (Mann–Whitney U test; p < 0.05) between the two datasets, despite the use of identical feature extraction methods. Model transferability is therefore difficult to achieve, which became evident during external testing (F1 score = 0.41). Oversampling, undersampling, clustering and harmonization techniques were applied to balance and harmonize the datasets, but did not improve the classification of KRAS mutation presence. In general, due to only a single moderate result (highest test F1 score = 0.67), the accuracy of KRAS prediction is not sufficient for clinical application. In future work, the complexity of KRAS mutation might be addressed by taking submutations into consideration. Larger multicentric datasets with balanced tumor stages, including multi-scanner datasets, seem to be necessary for building robust predictive models.
Open AccessMachine Learning-Based Radiomics Analysis for Identifying KRAS Mutations in Non-Small-Cell Lung Cancer from CT Images: Challenges, Insights and Implications
Kirsten Rat Sarcoma viral oncogene homolog (KRAS) is a frequently occurring mutation in non-small-cell lung cancer (NSCLC) and influences cancer treatment and disease progression. In this study, a machine learning (ML) pipeline was applied to radiomic features extracted from public and internal CT images to identify KRAS mutations in NSCLC patients. Both datasets were analyzed using parametric (t test) and non-parametric statistical tests (Mann–Whitney U test) and dimensionality reduction techniques. Afterwards, the proposed ML pipeline was applied to both datasets using a five-fold cross-validation on the training set (70/30 train/test split) before being validated on the other dataset. The results show that the radiomic features are significantly different (Mann–Whitney U test; p < 0.05) between the two datasets, despite the use of identical feature extraction methods. Model transferability is therefore difficult to achieve, which became evident during external testing (F1 score = 0.41). Oversampling, undersampling, clustering and harmonization techniques were applied to balance and harmonize the datasets, but did not improve the classification of KRAS mutation presence. In general, due to only a single moderate result (highest test F1 score = 0.67), the accuracy of KRAS prediction is not sufficient for clinical application. In future work, the complexity of KRAS mutation might be addressed by taking submutations into consideration. Larger multicentric datasets with balanced tumor stages, including multi-scanner datasets, seem to be necessary for building robust predictive models.
- 10 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 39 (1) , 140-151
Scatter Correction Based on GPU-Accelerated Full Monte Carlo Simulation for Brain PET/MRI
Accurate scatter correction is essential for qualitative and quantitative PET imaging. Up to now, scatter correction based on Monte Carlo simulation (MCS) has been recognized as the most accurate method of scatter correction for PET. However, the major disadvantage of MCS is its long computational time, which makes it unfeasible for clinical usage. Meanwhile, single scatter simulation (SSS) is the most widely used method for scatter correction. Nevertheless, SSS has the disadvantage of limited robustness for dynamic measurements and for the measurement of large objects. In this work, a newly developed implementation of MCS using graphics processing unit (GPU) acceleration is employed, allowing full MCS-based scatter correction in clinical 3D brain PET imaging. Starting from the generation of annihilation photons to their detection in the simulated PET scanner, all relevant physical interactions and transport phenomena of the photons were simulated on GPUs. This resulted in an expected distribution of scattered events, which was subsequently used to correct the measured emission data. The accuracy of the approach was validated with simulations using GATE (Geant4 Application for Tomography Emission), and its performance was compared to SSS. The comparison of the computation time between a GPU and a single-threaded CPU showed an acceleration factor of 776 for a voxelized brain phantom study. The speedup of the MCS implemented on the GPU represents a major step towards the application of the more accurate MCS-based scatter correction for PET imaging in clinical routine.
- 10 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 39 (1) , 140-151
Scatter Correction Based on GPU-Accelerated Full Monte Carlo Simulation for Brain PET/MRI
Accurate scatter correction is essential for qualitative and quantitative PET imaging. Up to now, scatter correction based on Monte Carlo simulation (MCS) has been recognized as the most accurate method of scatter correction for PET. However, the major disadvantage of MCS is its long computational time, which makes it unfeasible for clinical usage. Meanwhile, single scatter simulation (SSS) is the most widely used method for scatter correction. Nevertheless, SSS has the disadvantage of limited robustness for dynamic measurements and for the measurement of large objects. In this work, a newly developed implementation of MCS using graphics processing unit (GPU) acceleration is employed, allowing full MCS-based scatter correction in clinical 3D brain PET imaging. Starting from the generation of annihilation photons to their detection in the simulated PET scanner, all relevant physical interactions and transport phenomena of the photons were simulated on GPUs. This resulted in an expected distribution of scattered events, which was subsequently used to correct the measured emission data. The accuracy of the approach was validated with simulations using GATE (Geant4 Application for Tomography Emission), and its performance was compared to SSS. The comparison of the computation time between a GPU and a single-threaded CPU showed an acceleration factor of 776 for a voxelized brain phantom study. The speedup of the MCS implemented on the GPU represents a major step towards the application of the more accurate MCS-based scatter correction for PET imaging in clinical routine.
- Open Access
- 3 June 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (14) , 145012
Resolution modeling in projection space using a factorized multi-block detector response function for PET image reconstruction
Positron emission tomography (PET) images usually suffer from limited resolution and statistical uncertainties. However, a technique known as resolution modeling (RM) can be used to improve image quality by accurately modeling the system’s detection process within the iterative reconstruction. In this study, we present an accurate RM method in projection space based on a simulated multi-block detector response function (DRF) and evaluate it on the Siemens hybrid MR-BrainPET system. The DRF is obtained using GATE simulations that consider nearly all the possible annihilation photons from the field-of-view (FOV). Intrinsically, the multi-block DRF allows the block crosstalk to be modeled. The RM blurring kernel is further generated by factorizing the blurring matrix of one line-of-response (LOR) into two independent detector responses, which can then be addressed with the DRF. Such a kernel is shift-variant in 4D projection space without any distance or angle compression, and is integrated into the image reconstruction for the BrainPET insert with single instruction multiple data (SIMD) and multi-thread support. Evaluation of simulations and measured data demonstrate that the reconstruction with RM yields significantly improved resolutions and reduced mean squared error (MSE) values at different locations of the FOV, compared with reconstruction without RM. Furthermore, the shift-variant RM kernel models the varying blurring intensity for different LORs due to the depth-of-interaction (DOI) dependencies, thus avoiding severe edge artifacts in the images. Additionally, compared to RM in single-block mode, the multi-block mode shows significantly improved resolution and edge recovery at locations beyond 10 cm from the center of BrainPET insert in the transverse plane. However, the differences have been observed to be low for patient data between single-block and multi-block mode RM, due to the brain size and location as well as the geometry of the BrainPET insert. In conclusion, the RM method proposed in this study can yield better reconstructed images in terms of resolution and MSE value, compared to conventional reconstruction without RM.
- 3 June 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (14) , 145012
Open AccessResolution modeling in projection space using a factorized multi-block detector response function for PET image reconstruction
Positron emission tomography (PET) images usually suffer from limited resolution and statistical uncertainties. However, a technique known as resolution modeling (RM) can be used to improve image quality by accurately modeling the system’s detection process within the iterative reconstruction. In this study, we present an accurate RM method in projection space based on a simulated multi-block detector response function (DRF) and evaluate it on the Siemens hybrid MR-BrainPET system. The DRF is obtained using GATE simulations that consider nearly all the possible annihilation photons from the field-of-view (FOV). Intrinsically, the multi-block DRF allows the block crosstalk to be modeled. The RM blurring kernel is further generated by factorizing the blurring matrix of one line-of-response (LOR) into two independent detector responses, which can then be addressed with the DRF. Such a kernel is shift-variant in 4D projection space without any distance or angle compression, and is integrated into the image reconstruction for the BrainPET insert with single instruction multiple data (SIMD) and multi-thread support. Evaluation of simulations and measured data demonstrate that the reconstruction with RM yields significantly improved resolutions and reduced mean squared error (MSE) values at different locations of the FOV, compared with reconstruction without RM. Furthermore, the shift-variant RM kernel models the varying blurring intensity for different LORs due to the depth-of-interaction (DOI) dependencies, thus avoiding severe edge artifacts in the images. Additionally, compared to RM in single-block mode, the multi-block mode shows significantly improved resolution and edge recovery at locations beyond 10 cm from the center of BrainPET insert in the transverse plane. However, the differences have been observed to be low for patient data between single-block and multi-block mode RM, due to the brain size and location as well as the geometry of the BrainPET insert. In conclusion, the RM method proposed in this study can yield better reconstructed images in terms of resolution and MSE value, compared to conventional reconstruction without RM.
- 29 November 2018
- Published by Royal Society of Chemistry (RSC)
- p. 147-161
CHAPTER 6. Positron Emission Tomography Instrumentation
The basic principles of positron emission tomography (PET) systems have not changed since their conception in the mid-1970s. Almost all PET scanners consist of an annular arrangement of multiple scintillation detectors to build an entire ring surrounding the object to be imaged. The scintillation detector, which is the most essential building block of most PET scanners, consists of two key components: the scintillator and the photodetector. Dedicated data acquisition electronics convert charges from the scintillation detectors to digital signals, analyses them, sorts, and then stores them for image reconstruction. This chapter introduces the most important components and building blocks of common PET systems and discusses their performance, their limitations and their underlying physical principles. Further relevant methods for obtaining spatial and temporal information from scintillation detector signals are also briefly discussed. The chapter concludes by presenting the general concepts of typical PET system designs, the most important PET performance parameters and an overview of several representative existing systems.
- 29 November 2018
- Published by Royal Society of Chemistry (RSC)
- p. 147-161
CHAPTER 6. Positron Emission Tomography Instrumentation
The basic principles of positron emission tomography (PET) systems have not changed since their conception in the mid-1970s. Almost all PET scanners consist of an annular arrangement of multiple scintillation detectors to build an entire ring surrounding the object to be imaged. The scintillation detector, which is the most essential building block of most PET scanners, consists of two key components: the scintillator and the photodetector. Dedicated data acquisition electronics convert charges from the scintillation detectors to digital signals, analyses them, sorts, and then stores them for image reconstruction. This chapter introduces the most important components and building blocks of common PET systems and discusses their performance, their limitations and their underlying physical principles. Further relevant methods for obtaining spatial and temporal information from scintillation detector signals are also briefly discussed. The chapter concludes by presenting the general concepts of typical PET system designs, the most important PET performance parameters and an overview of several representative existing systems.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Full dynamic brain simulation using GATE in a high-performance computer
Dynamic PET brain studies are common in research and are becoming common in clinical applications. Simulation of dynamic PET is an important step to validate techniques and methods. This study compares the CPU and GPU version of a GATE simulation running on a high-performance computing system. We simulated the Siemens 3T MR-BrainPET with dynamic brain activity. The results show close agreement in the number of coincidence events, including phantom scatter, which we made available in the output of GPU simulation through code changes. The code will be made available to the GATE community and the simulation data is available to the interested researchers.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Full dynamic brain simulation using GATE in a high-performance computer
Dynamic PET brain studies are common in research and are becoming common in clinical applications. Simulation of dynamic PET is an important step to validate techniques and methods. This study compares the CPU and GPU version of a GATE simulation running on a high-performance computing system. We simulated the Siemens 3T MR-BrainPET with dynamic brain activity. The results show close agreement in the number of coincidence events, including phantom scatter, which we made available in the output of GPU simulation through code changes. The code will be made available to the GATE community and the simulation data is available to the interested researchers.