Yoshihiro Kimura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yoshihiro Kimura has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Atsushi Suzuki
Graduate School of Engineering, Tohoku University, Sendai 980-8579, Japan
10 shared publications - Yuki Yoshino
National Institute of Technology, Sendai College, Sendai 981-1239, Japan
4 shared publications - Kazuhiko Kasai
Specially Appointed Professor, Institute of Innovative Research, Tokyo Institute of Technology, Nagatsuta 4259-J3-9, Midori ward, Yokohama, Kanagawa 226-8502, Japan
3 shared publications - Daiki Shibata
School of Engineering, Tohoku University, Sendai 980-8577, Japan
2 shared publications - Nobuhiro Shimoi
Faculty of Systems Science and Technology, Akita Prefectural University, Yurihonjo City, Akita 015-0055, Japan
2 shared publications - Ruiyu Che
Graduate School of Engineering Tohoku University Sendai Miyagi Prefecture Japan
2 shared publications
Latest Publications
- Open Access
Impact of High-Temperature Exposure on Reinforced Concrete Structures Supported by Steel Ring-Shaped Shear Connectors
Ensuring the structural integrity of reinforced concrete (RC) components in nuclear facilities exposed to extreme conditions is essential for safe decommissioning. This study investigates the impact of high-temperature exposure on RC pedestal structures supported by steel ring-shaped shear connectors—critical elements for maintaining vertical and lateral load paths in containment systems. Scaled-down cyclic loading tests were performed on pedestal specimens with and without prior thermal exposure, simulating post-accident conditions observed at a damaged nuclear power plant. Experimental results show that thermal degradation significantly reduces lateral stiffness, with failure mechanisms concentrating at the interface between the concrete and the embedded steel skirt. Complementary finite element analyses, incorporating temperature-dependent material degradation, highlight the crucial role of load redistribution to steel components when concrete strength is compromised. Parametric studies reveal that while geometric variations in the inner skirt have limited influence, thermal history is the dominant factor affecting vertical capacity. Notably, even with substantial section loss in the concrete, the steel inner skirt maintained considerable load-bearing capacity. This study establishes a validated analytical framework for assessing structural performance under extreme conditions, offering critical insights for risk evaluation and retrofit strategies in the context of nuclear facility decommissioning.
Open AccessImpact of High-Temperature Exposure on Reinforced Concrete Structures Supported by Steel Ring-Shaped Shear Connectors
Ensuring the structural integrity of reinforced concrete (RC) components in nuclear facilities exposed to extreme conditions is essential for safe decommissioning. This study investigates the impact of high-temperature exposure on RC pedestal structures supported by steel ring-shaped shear connectors—critical elements for maintaining vertical and lateral load paths in containment systems. Scaled-down cyclic loading tests were performed on pedestal specimens with and without prior thermal exposure, simulating post-accident conditions observed at a damaged nuclear power plant. Experimental results show that thermal degradation significantly reduces lateral stiffness, with failure mechanisms concentrating at the interface between the concrete and the embedded steel skirt. Complementary finite element analyses, incorporating temperature-dependent material degradation, highlight the crucial role of load redistribution to steel components when concrete strength is compromised. Parametric studies reveal that while geometric variations in the inner skirt have limited influence, thermal history is the dominant factor affecting vertical capacity. Notably, even with substantial section loss in the concrete, the steel inner skirt maintained considerable load-bearing capacity. This study establishes a validated analytical framework for assessing structural performance under extreme conditions, offering critical insights for risk evaluation and retrofit strategies in the context of nuclear facility decommissioning.
- Open Access
- 27 February 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (5) , 2073
Development of an Environmentally Friendly Steel Structural Framework: Evaluation of Bending Stiffness and Yield Bending Moment of Cross-Laminated Timber Slab–H-Shaped Steel Composite Beams for Component Reuse
The building and construction sector accounts for nearly 40% of global greenhouse gas emissions, with steel-framed buildings being a significant contributor due to high CO2 emissions during production. To mitigate this issue, integrating Cross-Laminated Timber (CLT) into structural systems has emerged as a sustainable alternative. CLT, known for its carbon sequestration properties, offers an environmentally friendly replacement for reinforced-concrete slabs, particularly when paired with steel structures to enhance material reuse and reduce lifecycle impacts. This study focuses on hybrid systems combining H-shaped steel beams and CLT floor panels connected using high-strength friction bolts. A four-point bending test, simulating a secondary beam, was conducted, demonstrating that the composite effect significantly enhances flexural stiffness and strength. Additionally, a simplified method for evaluating the flexural stiffness and yielding strength of these composite beams, based on material and joint properties, was shown to successfully evaluate the test results.
- 27 February 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (5) , 2073
Open AccessDevelopment of an Environmentally Friendly Steel Structural Framework: Evaluation of Bending Stiffness and Yield Bending Moment of Cross-Laminated Timber Slab–H-Shaped Steel Composite Beams for Component Reuse
The building and construction sector accounts for nearly 40% of global greenhouse gas emissions, with steel-framed buildings being a significant contributor due to high CO2 emissions during production. To mitigate this issue, integrating Cross-Laminated Timber (CLT) into structural systems has emerged as a sustainable alternative. CLT, known for its carbon sequestration properties, offers an environmentally friendly replacement for reinforced-concrete slabs, particularly when paired with steel structures to enhance material reuse and reduce lifecycle impacts. This study focuses on hybrid systems combining H-shaped steel beams and CLT floor panels connected using high-strength friction bolts. A four-point bending test, simulating a secondary beam, was conducted, demonstrating that the composite effect significantly enhances flexural stiffness and strength. Additionally, a simplified method for evaluating the flexural stiffness and yielding strength of these composite beams, based on material and joint properties, was shown to successfully evaluate the test results.
- Open Access
Strength and Stiffness of Corrugated Plates Subjected to Bending
When a beam twists, localized flexural deformation in the plate occurs at the connection between the corrugated plate and the beam, resulting in a reduction in the bracing stiffness of the corrugated plate. To accurately assess the bracing stiffness of a beam with a connected corrugated plate, it is essential to independently determine the bending stiffness of the corrugated plate and the rotational stiffness of the plate–beam joint. This study conducts bending experiments on corrugated plates subjected to in-plane bending to elucidate the stress mechanisms within the plates. The influence of the width-to-thickness ratio on the bending load and bending stiffness of the corrugated plates is examined using the width-to-thickness ratio regulations of various countries. The findings revealed that when the width-to-thickness ratio of the corrugated plates used in this study was lower than the threshold specified in the Eurocode, the bending load at the onset of stiffness degradation was approximately 80% of the maximum bending load, and the initial bending stiffness corresponded closely to the theoretical value. Conversely, when the web width-to-thickness ratio of the corrugated plates exceeded the limit prescribed in the Eurocode, it was demonstrated that the maximum bending load decreased to approximately 50% of the yield load, and the initial bending stiffness was reduced to about 95% of the theoretical value.
Open AccessStrength and Stiffness of Corrugated Plates Subjected to Bending
When a beam twists, localized flexural deformation in the plate occurs at the connection between the corrugated plate and the beam, resulting in a reduction in the bracing stiffness of the corrugated plate. To accurately assess the bracing stiffness of a beam with a connected corrugated plate, it is essential to independently determine the bending stiffness of the corrugated plate and the rotational stiffness of the plate–beam joint. This study conducts bending experiments on corrugated plates subjected to in-plane bending to elucidate the stress mechanisms within the plates. The influence of the width-to-thickness ratio on the bending load and bending stiffness of the corrugated plates is examined using the width-to-thickness ratio regulations of various countries. The findings revealed that when the width-to-thickness ratio of the corrugated plates used in this study was lower than the threshold specified in the Eurocode, the bending load at the onset of stiffness degradation was approximately 80% of the maximum bending load, and the initial bending stiffness corresponded closely to the theoretical value. Conversely, when the web width-to-thickness ratio of the corrugated plates exceeded the limit prescribed in the Eurocode, it was demonstrated that the maximum bending load decreased to approximately 50% of the yield load, and the initial bending stiffness was reduced to about 95% of the theoretical value.
- Open Access
Compressive Strength of Concrete-Filled Steel Pipe Pile Head with Inner Ribs
Pile foundation failures during earthquakes can cause severe structural damage, emphasizing the importance of accurate strength evaluation. This study focuses on concrete-filled steel pipe pile heads with inner ribs, which play a crucial role in resisting compressive loads. Compression tests were conducted on specimens simulating pile heads to investigate stress transfer between the steel pipe and infill concrete. A numerical analysis model was developed using ABAQUS 6.14 and validated against experimental results, successfully reproducing load-deformation relationships and stress transfer mechanisms. Simulations extended the study by analyzing the bearing strength of the infill concrete under rib-induced pressure, with varying diameter-to-thickness ratios D/t. The results show that the compressive strength is primarily governed by the combined effects of steel pipe buckling resistance and concrete bearing resistance of a single layer of inner ribs. The proposed evaluation formula provides a lower-bound estimate of compressive strength and effectively captures key parameters influencing performance.
Open AccessCompressive Strength of Concrete-Filled Steel Pipe Pile Head with Inner Ribs
Pile foundation failures during earthquakes can cause severe structural damage, emphasizing the importance of accurate strength evaluation. This study focuses on concrete-filled steel pipe pile heads with inner ribs, which play a crucial role in resisting compressive loads. Compression tests were conducted on specimens simulating pile heads to investigate stress transfer between the steel pipe and infill concrete. A numerical analysis model was developed using ABAQUS 6.14 and validated against experimental results, successfully reproducing load-deformation relationships and stress transfer mechanisms. Simulations extended the study by analyzing the bearing strength of the infill concrete under rib-induced pressure, with varying diameter-to-thickness ratios D/t. The results show that the compressive strength is primarily governed by the combined effects of steel pipe buckling resistance and concrete bearing resistance of a single layer of inner ribs. The proposed evaluation formula provides a lower-bound estimate of compressive strength and effectively captures key parameters influencing performance.
- Open Access
- 1 January 2025
- Published by Wiley in JAPAN ARCHITECTURAL REVIEW
- Vol. 8 (1)
Structural Performance Evaluation of Composite Beams With Different Shear Transfer Mechanisms at Beam‐Slab Interface
In general, a steel beam is connected to a concrete slab using shear connectors, forming a composite beam. This composite action shifts the neutral axis under bending, resulting in a buckling behavior that differs from that of a bare steel beam. Moreover, the structural performance of composite beams is significantly influenced by the stress transfer mechanism facilitated by the shear connectors. However, the impact of shear connector and slab properties on buckling behavior has not been fully explored. To address this gap, this research first proposes a simplified method. For modeling composite beams that accurately reflects the behavior of shear connectors. Additionally, a comprehensive parametric study is conducted using an experimentally validated finite element analysis (FEA) model, exploring the influence of various shear connectors and slab properties. Based on the analytical results, a modified evaluation index and equation are ultimately proposed to enhance the assessment of composite beam performance.
- 1 January 2025
- Published by Wiley in JAPAN ARCHITECTURAL REVIEW
- Vol. 8 (1)
Open AccessStructural Performance Evaluation of Composite Beams With Different Shear Transfer Mechanisms at Beam‐Slab Interface
In general, a steel beam is connected to a concrete slab using shear connectors, forming a composite beam. This composite action shifts the neutral axis under bending, resulting in a buckling behavior that differs from that of a bare steel beam. Moreover, the structural performance of composite beams is significantly influenced by the stress transfer mechanism facilitated by the shear connectors. However, the impact of shear connector and slab properties on buckling behavior has not been fully explored. To address this gap, this research first proposes a simplified method. For modeling composite beams that accurately reflects the behavior of shear connectors. Additionally, a comprehensive parametric study is conducted using an experimentally validated finite element analysis (FEA) model, exploring the influence of various shear connectors and slab properties. Based on the analytical results, a modified evaluation index and equation are ultimately proposed to enhance the assessment of composite beam performance.
- Open Access
- 4 December 2024
- Published by MDPI AG in Applied Mechanics
- Vol. 5 (4) , 938-963
Seismic and Post-Seismic Ductility and Forces of Mid-Story Pin Moment-Resisting Frames Based on Scale of Local Deformation of I-Beam’s Segments
A mid-story pin system to avoid moment-resisting frame column failure during seismic action was proposed recently. The solution consists of a reinforced concrete (RC) pier protruding from the foundations, the steel column connected with the superstructure, and plates and the anchor bolt working as a pinned connection in between. This paper utilizes shell finite element analysis (FEA) models to examine the demanded column-to-beam strength ratio to keep the column elastic and maximize the story drift at the moment of beam buckling of the frame. The method of calculating post-seismic residual strength based on maximal buckling deformation of the beam is also proposed.
- 4 December 2024
- Published by MDPI AG in Applied Mechanics
- Vol. 5 (4) , 938-963
Open AccessSeismic and Post-Seismic Ductility and Forces of Mid-Story Pin Moment-Resisting Frames Based on Scale of Local Deformation of I-Beam’s Segments
A mid-story pin system to avoid moment-resisting frame column failure during seismic action was proposed recently. The solution consists of a reinforced concrete (RC) pier protruding from the foundations, the steel column connected with the superstructure, and plates and the anchor bolt working as a pinned connection in between. This paper utilizes shell finite element analysis (FEA) models to examine the demanded column-to-beam strength ratio to keep the column elastic and maximize the story drift at the moment of beam buckling of the frame. The method of calculating post-seismic residual strength based on maximal buckling deformation of the beam is also proposed.
- Open Access
Risk Assessment of Overturning of Freestanding Non-Structural Building Contents in Buckling-Restrained Braced Frames
The increasing demand in structural engineering now extends beyond collapse prevention to encompass business continuity planning (BCP). In response, energy dissipation devices have garnered significant attention for building response control. Among these, buckling-restrained braces (BRBs) are particularly favored due to their stable hysteretic behavior and well-established design provisions. However, BCP also necessitates the prevention of furniture overturning—an area that remains quantitatively underexplored in the context of buckling-restrained braced frames (BRBFs). Addressing this gap, this research designs BRBFs using various design criteria and performs incremental dynamic analysis (IDA) with artificially generated seismic waves. The results are compared with previously developed fragility curves for furniture overturning under different BRB design conditions. The findings demonstrate that the fragility of furniture overturning can be mitigated by a natural frequency shift, which alters the threshold of critical peak floor acceleration. These results, combined with hazard curves obtained from various locations across Japan, quantify the mean annual frequency of furniture overturning. The study reveals that increased floor acceleration in stiffer BRBFs can lead to a 3.8-fold higher risk of furniture overturning compared to frames without BRBs. This heightened risk also arises from the greater hazards at shorter natural periods due to stricter response reduction demands. The probabilistic risk analysis, which integrates fragility and hazard assessments, provides deeper insights into the evaluation of BCP.
Open AccessRisk Assessment of Overturning of Freestanding Non-Structural Building Contents in Buckling-Restrained Braced Frames
The increasing demand in structural engineering now extends beyond collapse prevention to encompass business continuity planning (BCP). In response, energy dissipation devices have garnered significant attention for building response control. Among these, buckling-restrained braces (BRBs) are particularly favored due to their stable hysteretic behavior and well-established design provisions. However, BCP also necessitates the prevention of furniture overturning—an area that remains quantitatively underexplored in the context of buckling-restrained braced frames (BRBFs). Addressing this gap, this research designs BRBFs using various design criteria and performs incremental dynamic analysis (IDA) with artificially generated seismic waves. The results are compared with previously developed fragility curves for furniture overturning under different BRB design conditions. The findings demonstrate that the fragility of furniture overturning can be mitigated by a natural frequency shift, which alters the threshold of critical peak floor acceleration. These results, combined with hazard curves obtained from various locations across Japan, quantify the mean annual frequency of furniture overturning. The study reveals that increased floor acceleration in stiffer BRBFs can lead to a 3.8-fold higher risk of furniture overturning compared to frames without BRBs. This heightened risk also arises from the greater hazards at shorter natural periods due to stricter response reduction demands. The probabilistic risk analysis, which integrates fragility and hazard assessments, provides deeper insights into the evaluation of BCP.
- Open Access
Evaluation of Rotation Capacity and Bauschinger Effect Coefficient of I-Shaped Beams Considering Loading Protocol Influences
Recent catastrophic earthquake events have reinforced the necessity of evaluating the seismic performance of buildings. Notably, the buildings can go into the plastic phase during a striking earthquake disaster. Under this condition, the current design codes assume seismic response reduction by virtue of the energy dissipation capacity of the structural members. In the strong-column–weak-beam design, which involves I-shaped beams and boxed columns, the mechanism is defined as a standard design scheme to prevent the building from collapsing. Therefore, energy dissipation relies highly on the I-shaped beam performance. However, the I-shaped beam performance can differ depending on the loading history experienced, whereas this effect is untouched in the prevailing evaluation equation. Hence, this study first performs cyclic loading tests of 11 specimens using different loading protocols. The experimental results clarify the fluctuation in the structural performance of I-shaped beams depending on the applied loading hysteresis, proving the necessity of considering the stress history for proper assessment. Furthermore, the database of experimental results is constructed based on the previous experimental studies. Ultimately, the novel evaluation equation is proposed to reflect the influences of the loading protocol. This equation is demonstrated to effectively assess the member performance retrieved from the experiment of 65 specimens, comprising 11 specimens from this investigation and 54 specimens from the database. The width–thickness ratio, shear span-to-depth ratio, and loading protocols are utilized as the evaluation parameters. Moreover, the prediction equation of the Bauschinger effect coefficient is newly established to convert the energy dissipation capacity under monotonically applied force into hysteretic energy dissipation under the cyclic forces.
Open AccessEvaluation of Rotation Capacity and Bauschinger Effect Coefficient of I-Shaped Beams Considering Loading Protocol Influences
Recent catastrophic earthquake events have reinforced the necessity of evaluating the seismic performance of buildings. Notably, the buildings can go into the plastic phase during a striking earthquake disaster. Under this condition, the current design codes assume seismic response reduction by virtue of the energy dissipation capacity of the structural members. In the strong-column–weak-beam design, which involves I-shaped beams and boxed columns, the mechanism is defined as a standard design scheme to prevent the building from collapsing. Therefore, energy dissipation relies highly on the I-shaped beam performance. However, the I-shaped beam performance can differ depending on the loading history experienced, whereas this effect is untouched in the prevailing evaluation equation. Hence, this study first performs cyclic loading tests of 11 specimens using different loading protocols. The experimental results clarify the fluctuation in the structural performance of I-shaped beams depending on the applied loading hysteresis, proving the necessity of considering the stress history for proper assessment. Furthermore, the database of experimental results is constructed based on the previous experimental studies. Ultimately, the novel evaluation equation is proposed to reflect the influences of the loading protocol. This equation is demonstrated to effectively assess the member performance retrieved from the experiment of 65 specimens, comprising 11 specimens from this investigation and 54 specimens from the database. The width–thickness ratio, shear span-to-depth ratio, and loading protocols are utilized as the evaluation parameters. Moreover, the prediction equation of the Bauschinger effect coefficient is newly established to convert the energy dissipation capacity under monotonically applied force into hysteretic energy dissipation under the cyclic forces.
- Open Access
Rotational Stiffening Performance of Roof Folded Plates in Torsion Tests and the Stiffening Effect of Roof Folded Plates on the Lateral Buckling of H Beams in Steel Structures
Non-structural members, such as roofs and ceilings, become affixed to main beams that are known as structural members. When such main beams experience bending or compressive forces that lead to lateral buckling, non-structural members may act to restrain the resulting lateral buckling deformation. Nevertheless, neither Japanese nor European guidelines advocate for the utilization of non-structural members as lateral buckling stiffeners for beams. Additionally, local buckling ensues near the bolt apertures in the beam–roof folded plate connection due to the torsional deformation induced by the lateral buckling of the H beam, thereby reducing the rotational stiffness of the roof folded plate to a percentage of its ideal stiffness. This paper conducts torsional experiments on roof folded plates, and with various connection methods between these plates and the beams, to comprehend the deformation mechanism of roof folded plates and the relationship between their rotational stiffness and the torsional moment. Then, the relationship between the demand values against restraining the lateral buckling of the main beam and the experimentally determined bearing capacity of the roof folded plate is elucidated. Results indicate the efficacy of utilizing the roof folded plate as a continuous brace. The lateral buckling design capacity of H beams that are continuously stiffened by roof folded plates is elucidated via application of a connection method that ensures joint stiffness between the roof folded plate and the beam while using Japanese and European design codes.
Open AccessRotational Stiffening Performance of Roof Folded Plates in Torsion Tests and the Stiffening Effect of Roof Folded Plates on the Lateral Buckling of H Beams in Steel Structures
Non-structural members, such as roofs and ceilings, become affixed to main beams that are known as structural members. When such main beams experience bending or compressive forces that lead to lateral buckling, non-structural members may act to restrain the resulting lateral buckling deformation. Nevertheless, neither Japanese nor European guidelines advocate for the utilization of non-structural members as lateral buckling stiffeners for beams. Additionally, local buckling ensues near the bolt apertures in the beam–roof folded plate connection due to the torsional deformation induced by the lateral buckling of the H beam, thereby reducing the rotational stiffness of the roof folded plate to a percentage of its ideal stiffness. This paper conducts torsional experiments on roof folded plates, and with various connection methods between these plates and the beams, to comprehend the deformation mechanism of roof folded plates and the relationship between their rotational stiffness and the torsional moment. Then, the relationship between the demand values against restraining the lateral buckling of the main beam and the experimentally determined bearing capacity of the roof folded plate is elucidated. Results indicate the efficacy of utilizing the roof folded plate as a continuous brace. The lateral buckling design capacity of H beams that are continuously stiffened by roof folded plates is elucidated via application of a connection method that ensures joint stiffness between the roof folded plate and the beam while using Japanese and European design codes.
- 1 January 2024
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 150 (1)
Rotation Capacity of I-Shaped Beams with Concrete Slab in Buckling-Restrained Braced Frames
- 1 January 2024
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 150 (1)
Rotation Capacity of I-Shaped Beams with Concrete Slab in Buckling-Restrained Braced Frames