Heung Su Jung
Heung Su Jung has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Bong-Hyun Jun
Department of Bioscience and Biotechnology Konkuk University Seoul Republic of Korea
4 shared publications - Jaehi Kim
Department of Bioscience and Biotechnology, Konkuk University, Seoul, Republic of Korea
3 shared publications - Dong-Eun Kim
Department of Bioscience and Biotechnology, Konkuk University, 120 Neungdong-ro, Gwangjin-gu, Seoul 05029, Republic of Korea
2 shared publications - Hobeom Song
Company of BioSquare, Hwaseong 18449, Korea
2 shared publications - Jaehyun An
Department of Bioscience and Biotechnology, Konkuk University, Seoul 05029, Republic of Korea
2 shared publications - Jung-Won Kim
Company of BioSquare, Hwaseong 18449, Korea
2 shared publications
Latest Publications
- Open Access
- 16 January 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (1) , 54
Aptamer-Conjugated Multi-Quantum Dot-Embedded Silica Nanoparticles for Lateral Flow Immunoassay
Lateral flow immunoassays (LFIAs) are widely used for their low cost, simplicity, and rapid results; however, enhancing their reliability requires the meticulous selection of ligands and nanoparticles (NPs). SiO2@QD@SiO2 (QD2) nanoparticles, which consist of quantum dots (QDs) embedded in a silica (SiO2) core and surrounded by an outer SiO2 shell, exhibit significantly higher fluorescence intensity (FI) compared to single QDs. In this study, we prepared QD2@PEG@Aptamer, an aptamer conjugated with QD2 using succinimidyl-[(N-maleimidopropionamido)-hexaethyleneglycol]ester, which is 130 times brighter than single QDs, for detecting carbohydrate antigen (CA) 19-9 through LFIA. For LFIA optimization, we determined the optimal conditions as a 1.0:2.0 × 10−2 ratio of polyethylene glycol (PEG) to aptamer by adjusting the amounts of PEG and aptamer, phosphate-buffered saline containing 0.5% Tween® 20 as a developing solution, and 0.15 μg NPs by setting the NP weight during development. Under these conditions, QD2@PEG@Aptamer selectively detected CA19-9, achieving a detection limit of 1.74 × 10−2 mg·mL−1. Moreover, FI remained stable for 10 days after detection. These results highlight the potential of QD2 and aptamer conjugation technology as a reliable and versatile sensing platform for various diagnostic applications.
- 16 January 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (1) , 54
Open AccessAptamer-Conjugated Multi-Quantum Dot-Embedded Silica Nanoparticles for Lateral Flow Immunoassay
Lateral flow immunoassays (LFIAs) are widely used for their low cost, simplicity, and rapid results; however, enhancing their reliability requires the meticulous selection of ligands and nanoparticles (NPs). SiO2@QD@SiO2 (QD2) nanoparticles, which consist of quantum dots (QDs) embedded in a silica (SiO2) core and surrounded by an outer SiO2 shell, exhibit significantly higher fluorescence intensity (FI) compared to single QDs. In this study, we prepared QD2@PEG@Aptamer, an aptamer conjugated with QD2 using succinimidyl-[(N-maleimidopropionamido)-hexaethyleneglycol]ester, which is 130 times brighter than single QDs, for detecting carbohydrate antigen (CA) 19-9 through LFIA. For LFIA optimization, we determined the optimal conditions as a 1.0:2.0 × 10−2 ratio of polyethylene glycol (PEG) to aptamer by adjusting the amounts of PEG and aptamer, phosphate-buffered saline containing 0.5% Tween® 20 as a developing solution, and 0.15 μg NPs by setting the NP weight during development. Under these conditions, QD2@PEG@Aptamer selectively detected CA19-9, achieving a detection limit of 1.74 × 10−2 mg·mL−1. Moreover, FI remained stable for 10 days after detection. These results highlight the potential of QD2 and aptamer conjugation technology as a reliable and versatile sensing platform for various diagnostic applications.
- Open Access
- 19 September 2022
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 23 (18) , 10977
Highly Bright Silica-Coated InP/ZnS Quantum Dot-Embedded Silica Nanoparticles as Biocompatible Nanoprobes
Quantum dots (QDs) have outstanding optical properties such as strong fluorescence, excellent photostability, broad absorption spectra, and narrow emission bands, which make them useful for bioimaging. However, cadmium (Cd)-based QDs, which have been widely studied, have potential toxicity problems. Cd-free QDs have also been studied, but their weak photoluminescence (PL) intensity makes their practical use in bioimaging challenging. In this study, Cd-free QD nanoprobes for bioimaging were fabricated by densely embedding multiple indium phosphide/zinc sulfide (InP/ZnS) QDs onto silica templates and coating them with a silica shell. The fabricated silica-coated InP/ZnS QD-embedded silica nanoparticles (SiO2@InP QDs@SiO2 NPs) exhibited hydrophilic properties because of the surface silica shell. The quantum yield (QY), maximum emission peak wavelength, and full-width half-maximum (FWHM) of the final fabricated SiO2@InP QDs@SiO2 NPs were 6.61%, 527.01 nm, and 44.62 nm, respectively. Moreover, the brightness of the particles could be easily controlled by adjusting the amount of InP/ZnS QDs in the SiO2@InP QDs@SiO2 NPs. When SiO2@InP QDs@SiO2 NPs were administered to tumor syngeneic mice, the fluorescence signal was prominently detected in the tumor because of the preferential distribution of the SiO2@InP QDs@SiO2 NPs, demonstrating their applicability in bioimaging with NPs. Thus, SiO2@InP QDs@SiO2 NPs have the potential to successfully replace Cd-based QDs as highly bright and biocompatible fluorescent nanoprobes.
- 19 September 2022
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 23 (18) , 10977
Open AccessHighly Bright Silica-Coated InP/ZnS Quantum Dot-Embedded Silica Nanoparticles as Biocompatible Nanoprobes
Quantum dots (QDs) have outstanding optical properties such as strong fluorescence, excellent photostability, broad absorption spectra, and narrow emission bands, which make them useful for bioimaging. However, cadmium (Cd)-based QDs, which have been widely studied, have potential toxicity problems. Cd-free QDs have also been studied, but their weak photoluminescence (PL) intensity makes their practical use in bioimaging challenging. In this study, Cd-free QD nanoprobes for bioimaging were fabricated by densely embedding multiple indium phosphide/zinc sulfide (InP/ZnS) QDs onto silica templates and coating them with a silica shell. The fabricated silica-coated InP/ZnS QD-embedded silica nanoparticles (SiO2@InP QDs@SiO2 NPs) exhibited hydrophilic properties because of the surface silica shell. The quantum yield (QY), maximum emission peak wavelength, and full-width half-maximum (FWHM) of the final fabricated SiO2@InP QDs@SiO2 NPs were 6.61%, 527.01 nm, and 44.62 nm, respectively. Moreover, the brightness of the particles could be easily controlled by adjusting the amount of InP/ZnS QDs in the SiO2@InP QDs@SiO2 NPs. When SiO2@InP QDs@SiO2 NPs were administered to tumor syngeneic mice, the fluorescence signal was prominently detected in the tumor because of the preferential distribution of the SiO2@InP QDs@SiO2 NPs, demonstrating their applicability in bioimaging with NPs. Thus, SiO2@InP QDs@SiO2 NPs have the potential to successfully replace Cd-based QDs as highly bright and biocompatible fluorescent nanoprobes.
- Open Access
- 18 March 2021
- Published by MDPI AG in Nanomaterials
- Vol. 11 (3) , 768
Multi-Quantum Dots-Embedded Silica-Encapsulated Nanoparticle-Based Lateral Flow Assay for Highly Sensitive Exosome Detection
Exosomes are attracting attention as new biomarkers for monitoring the diagnosis and prognosis of certain diseases. Colorimetric-based lateral-flow assays have been previously used to detect exosomes, but these have the disadvantage of a high limit of detection. Here, we introduce a new technique to improve exosome detection. In our approach, highly bright multi-quantum dots embedded in silica-encapsulated nanoparticles (M–QD–SNs), which have uniform size and are brighter than single quantum dots, were applied to the lateral flow immunoassay method to sensitively detect exosomes. Anti-CD63 antibodies were introduced on the surface of the M–QD–SNs, and a lateral flow immunoassay with the M–QD–SNs was conducted to detect human foreskin fibroblast (HFF) exosomes. Exosome samples included a wide range of concentrations from 100 to 1000 exosomes/µL, and the detection limit of our newly designed system was 117.94 exosome/μL, which was 11 times lower than the previously reported limits. Additionally, exosomes were selectively detected relative to the negative controls, liposomes, and newborn calf serum, confirming that this method prevented non-specific binding. Thus, our study demonstrates that highly sensitive and quantitative exosome detection can be conducted quickly and accurately by using lateral immunochromatographic analysis with M–QD–SNs.
- 18 March 2021
- Published by MDPI AG in Nanomaterials
- Vol. 11 (3) , 768
Open AccessMulti-Quantum Dots-Embedded Silica-Encapsulated Nanoparticle-Based Lateral Flow Assay for Highly Sensitive Exosome Detection
Exosomes are attracting attention as new biomarkers for monitoring the diagnosis and prognosis of certain diseases. Colorimetric-based lateral-flow assays have been previously used to detect exosomes, but these have the disadvantage of a high limit of detection. Here, we introduce a new technique to improve exosome detection. In our approach, highly bright multi-quantum dots embedded in silica-encapsulated nanoparticles (M–QD–SNs), which have uniform size and are brighter than single quantum dots, were applied to the lateral flow immunoassay method to sensitively detect exosomes. Anti-CD63 antibodies were introduced on the surface of the M–QD–SNs, and a lateral flow immunoassay with the M–QD–SNs was conducted to detect human foreskin fibroblast (HFF) exosomes. Exosome samples included a wide range of concentrations from 100 to 1000 exosomes/µL, and the detection limit of our newly designed system was 117.94 exosome/μL, which was 11 times lower than the previously reported limits. Additionally, exosomes were selectively detected relative to the negative controls, liposomes, and newborn calf serum, confirming that this method prevented non-specific binding. Thus, our study demonstrates that highly sensitive and quantitative exosome detection can be conducted quickly and accurately by using lateral immunochromatographic analysis with M–QD–SNs.
- Open Access
- 16 October 2020
- Published by Wiley in Journal of Nanomaterials
- Vol. 2020, 1-9
Surface Modification of a Stable CdSeZnS/ZnS Alloy Quantum Dot for Immunoassay
Quantum dots (QDs) are powerful materials in various bioapplications based on their excellent optical and electronic properties. For the application of various fields of QDs, surface modification of QDs is necessary. However, surface modification in QDs may result in a reduction in quantum yield (QY). This reduction of QY causes many weaknesses in the biological application of QDs. In this study, CdSeZnS/ZnS alloy QDs were used to prepare antibody-conjugated QDs for a sandwich immunoassay. The alloy QDs displayed a QY of 84.5% that was maintained at 83.0% (98.2% of QY was maintained) after surface modification with the anti-rabbit IgG as a model study. Surface-modified QDs successfully detected their corresponding target through antibody-antigen binding. The limit of detection was ng mL-1 for rabbit IgG.
- 16 October 2020
- Published by Wiley in Journal of Nanomaterials
- Vol. 2020, 1-9
Open AccessSurface Modification of a Stable CdSeZnS/ZnS Alloy Quantum Dot for Immunoassay
Quantum dots (QDs) are powerful materials in various bioapplications based on their excellent optical and electronic properties. For the application of various fields of QDs, surface modification of QDs is necessary. However, surface modification in QDs may result in a reduction in quantum yield (QY). This reduction of QY causes many weaknesses in the biological application of QDs. In this study, CdSeZnS/ZnS alloy QDs were used to prepare antibody-conjugated QDs for a sandwich immunoassay. The alloy QDs displayed a QY of 84.5% that was maintained at 83.0% (98.2% of QY was maintained) after surface modification with the anti-rabbit IgG as a model study. Surface-modified QDs successfully detected their corresponding target through antibody-antigen binding. The limit of detection was ng mL-1 for rabbit IgG.