Manik Jalhotra
Research Subjects
Manik Jalhotra has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Shivam Prakash Gautam
Technology Information, Forecasting and Assessment Council (TIFAC), Vellore Institute of Technology, Vellore, Tamil Nadu, India
6 shared publications - Lalit Kumar Sahu
Department of Electrical Engineering, National Institute of Technology, Raipur, India
5 shared publications - Allamsetty Hema Chander
Department of Electrical and Electronics Engineering, National Institute of Technology Puducherry, Karaikal, India
1 shared publication - Atif Iqbal
Department of Electrical Engineering, Qatar University, Doha, Qatar
1 shared publication - Kashem Mohammad Muttaqi
University of Wollongong
1 shared publication - Krishna Kumar Gupta
Department of Electrical and Instrumentation Engineering, Thapar Institute of Engineering and Technology, Patiala, Punjab, India
1 shared publication
Latest Publications
- Open Access
- 3 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 27729-27742
Investigating the Effectiveness of H-Bridge in Mitigating Switch Faults of a Single-Phase Five-Level Inverter
The use of multilevel inverters (MLIs) is increasingly popular due to their ability to operate at high power and reduce voltage stress on semiconductor switches compared to conventional inverters. However, the greater number of conducting semiconductor switches in MLIs, coupled with their higher failure rate, can weaken the inverter system. Five-level inverters provide an optimal balance by leveraging MLI benefits without significantly increasing semiconductor devices. This paper defines parameters to evaluate both quantitative and qualitative aspects of three recently proposed fault-tolerant MLI topologies. By scrutinizing these topologies, a generalized redundant leg architecture is proposed. This architecture is adaptable to any five-level MLI topology, whether it requires fault tolerance or already possesses it. The proposed solution, validated through comparative analysis and experiments, demonstrates superior fault tolerance with only one switch conducting from the redundant leg under faulty conditions, outperforming related works.
- 3 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 27729-27742
Open AccessInvestigating the Effectiveness of H-Bridge in Mitigating Switch Faults of a Single-Phase Five-Level Inverter
The use of multilevel inverters (MLIs) is increasingly popular due to their ability to operate at high power and reduce voltage stress on semiconductor switches compared to conventional inverters. However, the greater number of conducting semiconductor switches in MLIs, coupled with their higher failure rate, can weaken the inverter system. Five-level inverters provide an optimal balance by leveraging MLI benefits without significantly increasing semiconductor devices. This paper defines parameters to evaluate both quantitative and qualitative aspects of three recently proposed fault-tolerant MLI topologies. By scrutinizing these topologies, a generalized redundant leg architecture is proposed. This architecture is adaptable to any five-level MLI topology, whether it requires fault tolerance or already possesses it. The proposed solution, validated through comparative analysis and experiments, demonstrates superior fault tolerance with only one switch conducting from the redundant leg under faulty conditions, outperforming related works.
- Open Access
- 28 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 136934-136946
A Highly Resilient Fault Tolerant Topology of Single Phase Multilevel Inverter
Low reliability of the inverter is caused by high failure rates of semiconductor components and capacitors as well as high requirements for these components in the design of multilevel inverter topologies. The primary challenges in the reported fault-tolerant topology solutions include high component count, handling single and multiple switch faults, handling open and short switch failures on all fault locations, and achieving natural voltage balancing of the capacitors. This paper proposes a highly resilient fault-tolerant topology to accomplish the above challenges without compromising efficiency during faulty conditions. The acquired experimental results verify the proposed topology’s robustness and efficacy. The proposed topology is evaluated by considering multiple instances of switch failures to encompass various fault locations and types. A comparison with the recently reported fault-tolerant MLI topologies verifies the superiority of the proposed topology.
- 28 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 136934-136946
Open AccessA Highly Resilient Fault Tolerant Topology of Single Phase Multilevel Inverter
Low reliability of the inverter is caused by high failure rates of semiconductor components and capacitors as well as high requirements for these components in the design of multilevel inverter topologies. The primary challenges in the reported fault-tolerant topology solutions include high component count, handling single and multiple switch faults, handling open and short switch failures on all fault locations, and achieving natural voltage balancing of the capacitors. This paper proposes a highly resilient fault-tolerant topology to accomplish the above challenges without compromising efficiency during faulty conditions. The acquired experimental results verify the proposed topology’s robustness and efficacy. The proposed topology is evaluated by considering multiple instances of switch failures to encompass various fault locations and types. A comparison with the recently reported fault-tolerant MLI topologies verifies the superiority of the proposed topology.
- Open Access
- 8 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 97826-97839
Techniques to Reduce Capacitor Voltage Ripples in Multilevel Inverters
Reducing ripples on the capacitor voltage has two benefits: improved output waveform quality and accurate converter size. During the generation of a given output voltage level, the factor "Inherent Redundant Paths (IRPs)" has a considerable impact on the characteristics of multilevel inverter design. The consistent distribution of power loss derives from the Active Neutral Point-Clamed Inverter’s intrinsic redundant route at zero-voltage level generation. Even though it has been claimed that adding intrinsically redundant routes might give fault-tolerance capabilities to MLI topologies, the utilization of these pathways at intermediate voltage levels has not yet been studied. Based on this, the current research provides a unique charging and discharging technique is known as the alternating charging and discharging approach, which reduces capacitor voltage ripple. In addition, the suggested technique permits the inherent voltage balancing of capacitors without the need for supplemental components. The suggested alternative charging and discharging approach is implemented under both healthy and varied switch failure circumstances. In a laboratory prototype, the efficacy of the suggested alternative charging and discharging technique has been empirically tested.
- 8 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 97826-97839
Open AccessTechniques to Reduce Capacitor Voltage Ripples in Multilevel Inverters
Reducing ripples on the capacitor voltage has two benefits: improved output waveform quality and accurate converter size. During the generation of a given output voltage level, the factor "Inherent Redundant Paths (IRPs)" has a considerable impact on the characteristics of multilevel inverter design. The consistent distribution of power loss derives from the Active Neutral Point-Clamed Inverter’s intrinsic redundant route at zero-voltage level generation. Even though it has been claimed that adding intrinsically redundant routes might give fault-tolerance capabilities to MLI topologies, the utilization of these pathways at intermediate voltage levels has not yet been studied. Based on this, the current research provides a unique charging and discharging technique is known as the alternating charging and discharging approach, which reduces capacitor voltage ripple. In addition, the suggested technique permits the inherent voltage balancing of capacitors without the need for supplemental components. The suggested alternative charging and discharging approach is implemented under both healthy and varied switch failure circumstances. In a laboratory prototype, the efficacy of the suggested alternative charging and discharging technique has been empirically tested.
- Open Access
- 13 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 60866-60888
A Survey on Fault Tolerant and Diagnostic Techniques of Multilevel Inverter
Multilevel inverters are used in a number of high-power applications, including industrial motor drives, flexible power transmission, and, renewable energy systems. Since the MLI design incorporates a large number of devices, the system’s reliability suffers. This has caught the interest of academics all over the world, who are searching for methods to increase the dependability of the MLI design and include fault-tolerant qualities into it, either through software or hardware. Redundancy is a method that has recently gained popularity in solid-state transformer applications where fault tolerance is a highly desired quality. This is because the method provides for greater fault tolerance. The goal of this research is to offer a complete knowledge of the fault tolerance capabilities of MLIs created by the research community over the last few years.
- 13 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 60866-60888
Open AccessA Survey on Fault Tolerant and Diagnostic Techniques of Multilevel Inverter
Multilevel inverters are used in a number of high-power applications, including industrial motor drives, flexible power transmission, and, renewable energy systems. Since the MLI design incorporates a large number of devices, the system’s reliability suffers. This has caught the interest of academics all over the world, who are searching for methods to increase the dependability of the MLI design and include fault-tolerant qualities into it, either through software or hardware. Redundancy is a method that has recently gained popularity in solid-state transformer applications where fault tolerance is a highly desired quality. This is because the method provides for greater fault tolerance. The goal of this research is to offer a complete knowledge of the fault tolerance capabilities of MLIs created by the research community over the last few years.
- 19 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 9 (2) , 1915-1922
Highly Resilient Fault-Tolerant Topology of Single-Phase Multilevel Inverter
High failure rate of the semiconductor devices and capacitors, matched with their high requirement in the architecture of a multilevel inverter topology, results in low reliability of the inverter. A low device count, preserving the output power upon fault occurrence, ability to tolerate both open and short switch failure on all fault locations, handling both single and multiple switch failure, and achieving natural voltage balancing of the capacitors are the main challenges for the existing solutions to the fault tolerant topologies. Thus, a highly resilient fault tolerant topology, based on conventional inverters, is proposed in this paper. The proposed solution accomplishes all the challenges above without deteriorating the efficiency of the inverter during faulty conditions. The robustness and the effectiveness of the proposed topology are verified by the obtained experimental results. Multiple cases of switch failure are considered to cover all fault locations and types. Comparative analysis with the recently proposed fault-tolerant topologies on MLIs shows the superiority of the proposed topology over the rest.
- 19 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 9 (2) , 1915-1922
Highly Resilient Fault-Tolerant Topology of Single-Phase Multilevel Inverter
High failure rate of the semiconductor devices and capacitors, matched with their high requirement in the architecture of a multilevel inverter topology, results in low reliability of the inverter. A low device count, preserving the output power upon fault occurrence, ability to tolerate both open and short switch failure on all fault locations, handling both single and multiple switch failure, and achieving natural voltage balancing of the capacitors are the main challenges for the existing solutions to the fault tolerant topologies. Thus, a highly resilient fault tolerant topology, based on conventional inverters, is proposed in this paper. The proposed solution accomplishes all the challenges above without deteriorating the efficiency of the inverter during faulty conditions. The robustness and the effectiveness of the proposed topology are verified by the obtained experimental results. Multiple cases of switch failure are considered to cover all fault locations and types. Comparative analysis with the recently proposed fault-tolerant topologies on MLIs shows the superiority of the proposed topology over the rest.
- 1 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Fault Tolerant Analysis of Single Phase Multilevel Inverter
Low reliability of semiconductor switches result in the maloperation of the multilevel inverter (MLI). In order to gain the advantages offered by the MLI without compromising on the reliability, a fault tolerant topology of MLI is required. In this paper, the switched capacitor MLI (SCMLI) structure is explored to extract its inherent capacity for single switch and multiple switch failure. In order to incorporate fault tolerant characteristics to a 9 level SCMLI structure, the outermost capacitor is substituted by the DC voltage source. This results in the ability of the SCMLI to tolerate both single and multiple switch failure across all its level generating switches. Proper implementation of the switching scheme results in inherent capacitor voltage balancing. All the employed switches in the architecture of the topology of main inverter are fault tolerant. Least modification in the switching scheme after fault occurrence and less number of active switches makes the modified SCMLI topology more reliable with reduced device count. Assessment of the viability and robustness of the topology is verified through MATLAB simulation and experimentally validated using real-time simulator, OPAL-RT.
- 1 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Fault Tolerant Analysis of Single Phase Multilevel Inverter
Low reliability of semiconductor switches result in the maloperation of the multilevel inverter (MLI). In order to gain the advantages offered by the MLI without compromising on the reliability, a fault tolerant topology of MLI is required. In this paper, the switched capacitor MLI (SCMLI) structure is explored to extract its inherent capacity for single switch and multiple switch failure. In order to incorporate fault tolerant characteristics to a 9 level SCMLI structure, the outermost capacitor is substituted by the DC voltage source. This results in the ability of the SCMLI to tolerate both single and multiple switch failure across all its level generating switches. Proper implementation of the switching scheme results in inherent capacitor voltage balancing. All the employed switches in the architecture of the topology of main inverter are fault tolerant. Least modification in the switching scheme after fault occurrence and less number of active switches makes the modified SCMLI topology more reliable with reduced device count. Assessment of the viability and robustness of the topology is verified through MATLAB simulation and experimentally validated using real-time simulator, OPAL-RT.