JTJohannes Tümmler

Johannes Tümmler

*This is an algorithmically generated author record based on publicly available information.

Johannes Tümmler has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Towards Understanding Excited-State Properties of Organic Molecules Using Time-Resolved Soft X-ray Absorption Spectroscopy

    by Holger Stiel, Julia Braenzel, Adrian Jonas, Richard Gnewkow, Lisa Theresa Glöggler, Denny Sommer, Thomas Krist, Alexei Erko, Johannes Tümmler, Ioanna Mantouvalou

    The extension of the pump-probe approach known from UV/VIS spectroscopy to very short wavelengths together with advanced simulation techniques allows a detailed analysis of excited-state dynamics in organic molecules or biomolecular structures on a nanosecond to femtosecond time level. Optical pump soft X-ray probe spectroscopy is a relatively new approach to detect and characterize optically dark states in organic molecules, exciton dynamics or transient ligand-to-metal charge transfer states. In this paper, we describe two experimental setups for transient soft X-ray absorption spectroscopy based on an LPP emitting picosecond and sub-nanosecond soft X-ray pulses in the photon energy range between 50 and 1500 eV. We apply these setups for near-edge X-ray absorption fine structure (NEXAFS) investigations of thin films of a metal-free porphyrin, an aggregate forming carbocyanine and a nickel oxide molecule. NEXAFS investigations have been carried out at the carbon, nitrogen and oxygen K-edge as well as on the Ni L-edge. From time-resolved NEXAFS carbon, K-edge measurements of the metal-free porphyrin first insights into a long-lived trap state are gained. Our findings are discussed and compared with density functional theory calculations.


  • Open Access

    Regenerative thin-disk amplifier for 300 mJ pulse energy

    by Robert Jung, Johannes Tümmler, Ingo Will

    A regenerative amplifier based on thin-disk technology has been upgraded and optimized. Within a CPA laser system chirped 1 ns pulses are amplified to more than 300 mJ pulse energy. In addition to the high pulse energy the amplifier shows a very good energy stability with 0.25% (rms) fluctuation as well as an excellent beam quality of M2 = 1.04. The regenerative amplifier is equipped with an Yb:YAG thin-disk of 17 mm in diameter pumped with 1.75 kW peak power. It is operated at a repetition rate of 100 Hz. The optical-to-optical efficiency is better than 18%. The laser pulses are compressed to 1.8 ps pulse duration.


  • High-repetition-rate chirped-pulse-amplification thin-disk laser system with joule-level pulse energy

    by J. Tümmler, R. Jung, H. Stiel, P. V. Nickles, W. Sandner

    We are reporting on the development of a diode-pumped chirped-pulse-amplification (CPA) laser system based on Yb:YAG thin-disk technology with a repetition rate of 100 Hz and output pulse energy in the joule range. The focus lies with the first results of the preamplifier—a regenerative amplifier (RA) and a multipass amplifier (MP). The system consists of a front end including the CPA stretcher followed by an amplifier chain based on Yb:YAG thin-disk amplifiers and the CPA compressor. It is developed in the frame of our x-ray laser (XRL) program and fulfills all requirements for pumping a plasma-based XRL in grazing incidence pumping geometry. Of course it can also be used for other interesting applications. With the RA pulse energies of more than 165 mJ can be realized. At a repetition rate of 100 Hz a stability of 0.8% (1σ) over a period of more than 45 min has been measured. The optical-to-optical efficiency is 14%. The following MP amplifier can increase the pulse energy to more than 300 mJ. A nearly bandwidth-limited recompression to less than 2 ps could be demonstrated.


  • 10−Hzgrazing–incidence pumped Ni-like Mo x-ray laser

    by J. Tümmler, K. A. Janulewicz, G. Priebe, P. V. Nickles

    The operation of a Ni-like Mo x-ray laser at 18.9nm with a repetition rate of 10Hz has been demonstrated. The laser has been pumped applying the grazing incidence pump arrangement, where a short (picoseconds) pulse irradiates a Mo plasma column generated by a long (a few hundred picoseconds) pulse. The delayed short pulse is incident at a grazing angle on the plasma to heat it efficiently. We used a total energy of less than 450mJ (150mJ in the long and 250–300mJ in the short pulse) in a line focus of 7mm by 50μm.