Manuel Botejara-Antúnez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Manuel Botejara-Antúnez has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Justo García-Sanz-Calcedo
Departamento de Expresión Gráfica, Escuela de Ingenierías Industriales, Universidad de Extremadura
15 shared publications - Gonzalo Sánchez-Barroso
Departamento de Expresión Gráfica, Escuela de Ingenierías Industriales, Universidad de Extremadura
8 shared publications - Jaime González-Domínguez
Área de Proyectos de Ingeniería, Departamento de Expresión Gráfica, Universidad de Extremadura, Avenida de Elvas s/n, 06006 Badajoz, Spain
8 shared publications - Alejandro Prieto-Fernández
University of Extremadura
3 shared publications Jaime González-Domínguez
3 shared publications- Pablo Garrido-Píriz
Departamento de Expresión Gráfica, Escuela de Ingenierías Industriales, Universidad de Extremadura, Avenida de Elvas, S/N, 06006 Badajoz, Spain
3 shared publications
Latest Publications
- 6 October 2026
- Published by Springer Nature
- p. 243-246
Comparative Life Cycle Assessment of Sol–Gel Coatings for CSP Plants
- 6 October 2026
- Published by Springer Nature
- p. 243-246
Comparative Life Cycle Assessment of Sol–Gel Coatings for CSP Plants
- Open Access
- 3 September 2026
- Published by Elsevier in Journal of Water Process Engineering
- Vol. 92
Current density performance prediction for a microbial electrolysis cell using machine learning methods
- 3 September 2026
- Published by Elsevier in Journal of Water Process Engineering
- Vol. 92
Open AccessCurrent density performance prediction for a microbial electrolysis cell using machine learning methods
- Open Access
- 30 April 2026
- Published by MDPI AG in Smart Cities
- Vol. 9 (5) , 79
Energy Consumption Forecasting in Public Nursing Homes Using Multivariable Regression Models
Buildings represent 40% of the European Union’s energy consumption and 36% of its greenhouse gas emissions. Nursing homes are among the buildings that consume the most energy. The objective of this study was to make predictive models of Energy Consumption, Energy Costs, and CO2 Emissions in nursing homes using different variables. To do this, data from 20 public nursing homes located in Extremadura (Spain) during the 2019–2023 period were analyzed. All the buildings were built or renovated between 1995 and 2009; the useful area and the number of residents were in the range of 1332–10,880 m2 and 24–254 residents. A statistical analysis was performed using multivariable linear regression. During the research, equations that allow for the estimation of the annual Energy Consumption, Energy Costs and CO2 Emissions of nursing homes, according to the useful area and number of residents, were found. The Radj2 was 0.9710, 0.9744 and 0.9742, respectively. The quality of the models obtained was contrasted using the mean absolute error (MAE), the relative error (RE) and the root mean square error (RMSE), together with the assessment of multicollinearity through the Variance Inflation Factor (VIF). The findings of this study may prove beneficial for stakeholders within the elder care sector.
- 30 April 2026
- Published by MDPI AG in Smart Cities
- Vol. 9 (5) , 79
Open AccessEnergy Consumption Forecasting in Public Nursing Homes Using Multivariable Regression Models
Buildings represent 40% of the European Union’s energy consumption and 36% of its greenhouse gas emissions. Nursing homes are among the buildings that consume the most energy. The objective of this study was to make predictive models of Energy Consumption, Energy Costs, and CO2 Emissions in nursing homes using different variables. To do this, data from 20 public nursing homes located in Extremadura (Spain) during the 2019–2023 period were analyzed. All the buildings were built or renovated between 1995 and 2009; the useful area and the number of residents were in the range of 1332–10,880 m2 and 24–254 residents. A statistical analysis was performed using multivariable linear regression. During the research, equations that allow for the estimation of the annual Energy Consumption, Energy Costs and CO2 Emissions of nursing homes, according to the useful area and number of residents, were found. The Radj2 was 0.9710, 0.9744 and 0.9742, respectively. The quality of the models obtained was contrasted using the mean absolute error (MAE), the relative error (RE) and the root mean square error (RMSE), together with the assessment of multicollinearity through the Variance Inflation Factor (VIF). The findings of this study may prove beneficial for stakeholders within the elder care sector.
- Open Access
- 2 April 2026
- Published by Elsevier in SSRN Electronic Journal
Strategic and Sustainable selection/assessment of low-melting point Molten Salts for thermal energy storage in CSP systems
The selection of Thermal Energy Storage (TES) materials for Concentrated Solar Power (CSP) plants is primarily governed by environmental performance, energy efficiency, and economic viability, where low-melting point Molten Salts are positioned to be one of the preferred alternatives due to their operational stability, high heat capacity, and low vapor pressure. In this study, 12 low-melting point Molten Salts were thermophysically characterized (the traditional Solar Salt, Hitec® y Hitec XL®, and 9 new formulations), and their environmental performance per unit of heat transfer was assessed using SimaPro 10.1 software, the ReCiPe 2016 assessment method, the ”cradle-to-grave” approach and the Ecoinvent 3.11 database. The results indicate that Molten Salts containing LiNO3, specifically Salt #5, exhibit the best thermophysical properties and the lowest impact values (38.78 mPt/J), achieving the better outcomes in 7 out of 22 impact categories, as well as across the three endpoint damage areas for intermediate cost values (1.10 €/J). Furthermore, Solar Salt was found to have the highest environmental impact score (131.03 mPt/J). The knowledge gained through this research provides a comprehensive understanding of the environmental impacts associated with CSP plants, thereby enhancing decision-making processes among stakeholders and supporting the transition toward a decarbonized energy sector.
- 2 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessStrategic and Sustainable selection/assessment of low-melting point Molten Salts for thermal energy storage in CSP systems
The selection of Thermal Energy Storage (TES) materials for Concentrated Solar Power (CSP) plants is primarily governed by environmental performance, energy efficiency, and economic viability, where low-melting point Molten Salts are positioned to be one of the preferred alternatives due to their operational stability, high heat capacity, and low vapor pressure. In this study, 12 low-melting point Molten Salts were thermophysically characterized (the traditional Solar Salt, Hitec® y Hitec XL®, and 9 new formulations), and their environmental performance per unit of heat transfer was assessed using SimaPro 10.1 software, the ReCiPe 2016 assessment method, the ”cradle-to-grave” approach and the Ecoinvent 3.11 database. The results indicate that Molten Salts containing LiNO3, specifically Salt #5, exhibit the best thermophysical properties and the lowest impact values (38.78 mPt/J), achieving the better outcomes in 7 out of 22 impact categories, as well as across the three endpoint damage areas for intermediate cost values (1.10 €/J). Furthermore, Solar Salt was found to have the highest environmental impact score (131.03 mPt/J). The knowledge gained through this research provides a comprehensive understanding of the environmental impacts associated with CSP plants, thereby enhancing decision-making processes among stakeholders and supporting the transition toward a decarbonized energy sector.
- Open Access
- 11 March 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (6) , 2449
Selection of Sol-Gel Coatings by the Analytic Hierarchy Process and Life Cycle Assessment for Concentrated Solar Power Plants
Sol-gel coatings are commonly used to prevent corrosion from molten salt mixtures in CSP plants. Until now, they have been driven primarily by cost considerations, without integrating environmental criteria into the modeling and decision-making process. The novelty of this study lies in the development of an evaluation framework that incorporates environmental impact alongside technical and economic factors, providing a more sustainable approach. This work assesses porosity, thermal shock resistance, and thickness to determine the optimal sol-gel coating. For this purpose, the multi-criteria decision-making technique “Analytic Hierarchy Process” (AHP) and the Life Cycle Assessment (LCA) methodology are implemented. The results show that the scores obtained for the 3YSZ-5A (5% mol) coating are higher than those of the 3YSZ (3% mol) and 3YSZ-20A (20% mol) coatings, between 1.52 and 1.69, respectively. The 3YSZ-5A coating (5% mol) is the optimal solution among all the systems analyzed, with a score of 0.61 AHP pt. The coating of the same type and higher molar concentration (20%) achieved 0.55 AHP pt. Finally, the 3YSZ type coating received the lowest rating, with a score of 0.36 AHP pt. The insights generated in this research will support decision-making in the design and maintenance of CSP plants.
- 11 March 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (6) , 2449
Open AccessSelection of Sol-Gel Coatings by the Analytic Hierarchy Process and Life Cycle Assessment for Concentrated Solar Power Plants
Sol-gel coatings are commonly used to prevent corrosion from molten salt mixtures in CSP plants. Until now, they have been driven primarily by cost considerations, without integrating environmental criteria into the modeling and decision-making process. The novelty of this study lies in the development of an evaluation framework that incorporates environmental impact alongside technical and economic factors, providing a more sustainable approach. This work assesses porosity, thermal shock resistance, and thickness to determine the optimal sol-gel coating. For this purpose, the multi-criteria decision-making technique “Analytic Hierarchy Process” (AHP) and the Life Cycle Assessment (LCA) methodology are implemented. The results show that the scores obtained for the 3YSZ-5A (5% mol) coating are higher than those of the 3YSZ (3% mol) and 3YSZ-20A (20% mol) coatings, between 1.52 and 1.69, respectively. The 3YSZ-5A coating (5% mol) is the optimal solution among all the systems analyzed, with a score of 0.61 AHP pt. The coating of the same type and higher molar concentration (20%) achieved 0.55 AHP pt. Finally, the 3YSZ type coating received the lowest rating, with a score of 0.36 AHP pt. The insights generated in this research will support decision-making in the design and maintenance of CSP plants.
- Open Access
- 16 January 2025
- Published by Elsevier in Sustainable Energy Technologies and Assessments
- Vol. 74
Life cycle and environmental impact assessment of heat transfer fluids in parabolic trough CSP plants
- 16 January 2025
- Published by Elsevier in Sustainable Energy Technologies and Assessments
- Vol. 74
Open AccessLife cycle and environmental impact assessment of heat transfer fluids in parabolic trough CSP plants
- Open Access
- 9 January 2025
- Published by Elsevier in Journal of Water Process Engineering
- Vol. 70
Comparative life cycle analysis of Legionella treatment and prevention systems in healthcare buildings DHW facilities
- 9 January 2025
- Published by Elsevier in Journal of Water Process Engineering
- Vol. 70
Open AccessComparative life cycle analysis of Legionella treatment and prevention systems in healthcare buildings DHW facilities
- Open Access
- 1 January 2025
- Published by Wiley in Journal of Engineering
- Vol. 2025 (1)
A Quantitative Approach to Modeling the Overconsumption of Energy in Healthcare Buildings
Healthcare buildings consume 2.6 times more energy than commercial buildings, primarily due to the operation of electromedical equipment and the stringent indoor environmental requirements for medical practice. This fact underscores the need for research aimed at addressing the high intensity of energy consumption. For this purpose, methods employing building energy simulation, mathematical correlation models, and machine learning algorithms have been developed to quantify the impact of various variables on energy consumption. However, the specific influence of individual attribute variations within these variables has not yet been fully disaggregated. To bridge this gap in knowledge, 70 healthcare buildings in Spain were analyzed to model the interaction among parameters in healthcare buildings affecting the overconsumption of energy. The quantitative multifactor dimensionality reduction method was employed to analyze the phenomenon under study by developing three models: final energy consumption, energy demand, and thermal energy consumption. Having more than 5000 assigned patients increases the likelihood of exceeding final energy consumption by 17.3%, relying on fossil fuel boilers for heating raises the risk of higher‐than‐average energy demand by 30.0%, and installing heat pumps with less than 5 kW power increases the risk of elevated thermal energy consumption by 15.0%–38.1%. Results indicate that energy consumption intensity is significantly influenced by demographic variables and the heating, ventilation, and air‐conditioning systems of healthcare buildings. The research findings will guide the design of new healthcare buildings and assist facility managers in more effectively allocating operational expenses.
- 1 January 2025
- Published by Wiley in Journal of Engineering
- Vol. 2025 (1)
Open AccessA Quantitative Approach to Modeling the Overconsumption of Energy in Healthcare Buildings
Healthcare buildings consume 2.6 times more energy than commercial buildings, primarily due to the operation of electromedical equipment and the stringent indoor environmental requirements for medical practice. This fact underscores the need for research aimed at addressing the high intensity of energy consumption. For this purpose, methods employing building energy simulation, mathematical correlation models, and machine learning algorithms have been developed to quantify the impact of various variables on energy consumption. However, the specific influence of individual attribute variations within these variables has not yet been fully disaggregated. To bridge this gap in knowledge, 70 healthcare buildings in Spain were analyzed to model the interaction among parameters in healthcare buildings affecting the overconsumption of energy. The quantitative multifactor dimensionality reduction method was employed to analyze the phenomenon under study by developing three models: final energy consumption, energy demand, and thermal energy consumption. Having more than 5000 assigned patients increases the likelihood of exceeding final energy consumption by 17.3%, relying on fossil fuel boilers for heating raises the risk of higher‐than‐average energy demand by 30.0%, and installing heat pumps with less than 5 kW power increases the risk of elevated thermal energy consumption by 15.0%–38.1%. Results indicate that energy consumption intensity is significantly influenced by demographic variables and the heating, ventilation, and air‐conditioning systems of healthcare buildings. The research findings will guide the design of new healthcare buildings and assist facility managers in more effectively allocating operational expenses.
- Open Access
- 24 October 2024
- Published by Elsevier in Renewable Energy
- Vol. 237
Environmental impact assessment of a direct methanol fuel cell and strategic mitigation guidelines
- 24 October 2024
- Published by Elsevier in Renewable Energy
- Vol. 237
Open AccessEnvironmental impact assessment of a direct methanol fuel cell and strategic mitigation guidelines
- 18 July 2024
- Published by Springer Nature
- p. 149-152
Life Cycle Assessment of the Production Process of Lithium-Ion Cylindrical Cell Batteries
- 18 July 2024
- Published by Springer Nature
- p. 149-152
Life Cycle Assessment of the Production Process of Lithium-Ion Cylindrical Cell Batteries