AMAnna Maisano

Anna Maisano

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Anna Maisano has a total of 8 co-authors. Here are the top co-authors by number of shared publications:

  • Alessandro Albini

    Division of Cardiology, Department of Diagnostics, Clinical and Public Health Medicine, Policlinico University Hospital of Modena, University of Modena and Reggio Emilia, 41121 Modena, Italy

    1 shared publication
  • Andrea Barbieri

    Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, 41124 Modena, Italy

    1 shared publication
  • Francesca Bursi

    Cardiology Unit, Health and Sciences Department, University of Milan, ASST Santi Paolo e Carlo, 20162 Milan, Italy

    1 shared publication
  • Francesca Mantovani

    Cardiology Unit, Azienda USL-IRCCS di Reggio Emilia, Viale Risorgimento 80, 42123 Reggio Emilia, Italy

    1 shared publication
  • Gerardo De Mitri

    Division of Cardiology, Department of Diagnostics, Clinical and Public Health Medicine, Policlinico University Hospital of Modena, University of Modena and Reggio Emilia, 41121 Modena, Italy

    1 shared publication
  • Giovanni Camaioni

    Division of Cardiology, Department of Diagnostics, Clinical and Public Health Medicine, Policlinico University Hospital of Modena, University of Modena and Reggio Emilia, 41121 Modena, Italy

    1 shared publication

Latest Publications

  • Open Access

    Echocardiographic Left Ventricular Mass Assessment: Correlation between 2D-Derived Linear Dimensions and 3-Dimensional Automated, Machine Learning-Based Methods in Unselected Patients

    by Andrea Barbieri, Francesca Bursi, Giovanni Camaioni, Anna Maisano, Jacopo Francesco Imberti, Alessandro Albini, Gerardo De Mitri, Francesca Mantovani, Giuseppe Boriani

    A recently developed algorithm for 3D analysis based on machine learning (ML) principles detects left ventricular (LV) mass without any human interaction. We retrospectively studied the correlation between 2D-derived linear dimensions using the ASE/EACVI-recommended formula and 3D automated, ML-based methods (Philips HeartModel) regarding LV mass quantification in unselected patients undergoing echocardiography. We included 130 patients (mean age 60 ± 18 years; 45% women). There was only discrete agreement between 2D and 3D measurements of LV mass (r = 0.662, r2 = 0.348, p < 0.001). The automated algorithm yielded an overestimation of LV mass compared to the linear method (Bland–Altman positive bias of 13.1 g with 95% limits of the agreement at 4.5 to 21.6 g, p = 0.003, ICC 0.78 (95%CI 0.68−8.4). There was a significant proportional bias (Beta −0.22, t = −2.9) p = 0.005, the variance of the difference varied across the range of LV mass. When the published cut-offs for LV mass abnormality were used, the observed proportion of overall agreement was 77% (kappa = 0.32, p < 0.001). In consecutive patients undergoing echocardiography for any indications, LV mass assessment by 3D analysis using a novel ML-based algorithm showed systematic differences and wide limits of agreements compared with quantification by ASE/EACVI- recommended formula when the current cut-offs and partition values were applied.