Xing-Ju Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xing-Ju Yang has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Feng Lin
Tongji Univ, Dept Struct Engn, 1239 Siping Rd, Shanghai 200092, Peoples R China
6 shared publications Chao Yang
3 shared publicationsGang Wu
3 shared publicationsLiangqin Wu
3 shared publicationsXiang-Lin Gu
3 shared publicationsJunjie Yang
2 shared publications
Latest Publications
- Open Access
- 28 July 2026
- Published by Elsevier in SSRN Electronic Journal
Acoustic-emission-based damage assessment of CFRP-confined corroded reinforced concrete square columns under axial compression
This study investigates crack propagation and failure behavior of CFRP-strengthened reinforced concrete (RC) columns under axial compression, focusing on the effect of corrosion level. Acoustic emission (AE) monitoring was used to capture damage evolution, and ringing counts, signal intensity, b-value, crack intensity, severity, and historical index were analyzed to identify damage characteristics and failure mechanisms. Results show that increasing corrosion shifts the failure mode from concrete crushing and CFRP cracking to CFRP delamination, reinforcement buckling, and catastrophic brittle failure. At 20% corrosion, peak and yield loads decreased by approximately 20% and 29%, indicating reduced CFRP confinement efficiency under severe corrosion. AE results further indicate that corrosion promotes earlier damage initiation and more frequent microcracking. With increasing corrosion, AE signals shifted toward low-frequency components, reflecting macroscopic crack growth, CFRP debonding, and severe internal damage. The decreasing Ib-value reveals a transition from dispersed low-amplitude microcracking to concentrated high-amplitude damage, indicating enhanced brittleness. Sr and HI analyses confirm that CFRP confinement delays unstable failure in lightly corroded columns, but its efficiency declines as corrosion weakens CFRP–concrete bonding. These findings highlight the critical role of corrosion in degrading CFRP-strengthened RC columns and demonstrate the value of AE monitoring for damage assessment and reinforcement design.
- 28 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessAcoustic-emission-based damage assessment of CFRP-confined corroded reinforced concrete square columns under axial compression
This study investigates crack propagation and failure behavior of CFRP-strengthened reinforced concrete (RC) columns under axial compression, focusing on the effect of corrosion level. Acoustic emission (AE) monitoring was used to capture damage evolution, and ringing counts, signal intensity, b-value, crack intensity, severity, and historical index were analyzed to identify damage characteristics and failure mechanisms. Results show that increasing corrosion shifts the failure mode from concrete crushing and CFRP cracking to CFRP delamination, reinforcement buckling, and catastrophic brittle failure. At 20% corrosion, peak and yield loads decreased by approximately 20% and 29%, indicating reduced CFRP confinement efficiency under severe corrosion. AE results further indicate that corrosion promotes earlier damage initiation and more frequent microcracking. With increasing corrosion, AE signals shifted toward low-frequency components, reflecting macroscopic crack growth, CFRP debonding, and severe internal damage. The decreasing Ib-value reveals a transition from dispersed low-amplitude microcracking to concentrated high-amplitude damage, indicating enhanced brittleness. Sr and HI analyses confirm that CFRP confinement delays unstable failure in lightly corroded columns, but its efficiency declines as corrosion weakens CFRP–concrete bonding. These findings highlight the critical role of corrosion in degrading CFRP-strengthened RC columns and demonstrate the value of AE monitoring for damage assessment and reinforcement design.
- Open Access
- 26 June 2026
- Published by Elsevier in SSRN Electronic Journal
Shear-Enhanced Spall Damage in Truncated Conical Tantalum under Plate Impact
Spall in shock-loaded metals is conventionally studied under uniaxial strain, yet service components often experience non-uniaxial stress states. How coupled tension-shear stresses alter spall mechanism and macroscopic strength remains poorly understood. Here we simultaneously generate uniaxial and non-uniaxial strain regions in a single shot by plate impact on truncated conical tantalum targets with two cone angles (15° and 45°). Free-surface velocity, post-mortem electron backscatter diffraction, and finite-element simulations are combined to correlate local stress histories with damage evolution. In the conical surface region, oblique shock incidence and rarefaction-wave interactions beneath the inclined free surface drive a noteworthy stress-state evolution from shear to a coupled tension-shear state, with peak shear stresses reaching ~750 MPa. Although the peak pressure (~10.9 GPa) is below the threshold for deformation twinning in polycrystalline tantalum under conventional uniaxial-strain loading, the localized shear stress promotes abundant deformation twins whose boundaries act as preferential void nucleation sites. In sharp contrast, the central uniaxial region is twin-free and exhibits only isolated voids. The consequent accelerated void coalescence reduces spall strength monotonically with increasing shear strain, where a shear strain of 0.77% lowers the strength by 11.2%, and 1.39% by 30.2%. Numerical simulations reproduce the observed wave interactions, shear stress distribution, and damage morphology, confirming the shear-mediated twinning-damage scenario. These findings reveal the mechanism where the geometry-induced stress state governs deformation twinning, void evolution and the spall strength degradation, offering essential guidance for the design and safety evaluation of high-strength metals under complex dynamic loading.
- 26 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessShear-Enhanced Spall Damage in Truncated Conical Tantalum under Plate Impact
Spall in shock-loaded metals is conventionally studied under uniaxial strain, yet service components often experience non-uniaxial stress states. How coupled tension-shear stresses alter spall mechanism and macroscopic strength remains poorly understood. Here we simultaneously generate uniaxial and non-uniaxial strain regions in a single shot by plate impact on truncated conical tantalum targets with two cone angles (15° and 45°). Free-surface velocity, post-mortem electron backscatter diffraction, and finite-element simulations are combined to correlate local stress histories with damage evolution. In the conical surface region, oblique shock incidence and rarefaction-wave interactions beneath the inclined free surface drive a noteworthy stress-state evolution from shear to a coupled tension-shear state, with peak shear stresses reaching ~750 MPa. Although the peak pressure (~10.9 GPa) is below the threshold for deformation twinning in polycrystalline tantalum under conventional uniaxial-strain loading, the localized shear stress promotes abundant deformation twins whose boundaries act as preferential void nucleation sites. In sharp contrast, the central uniaxial region is twin-free and exhibits only isolated voids. The consequent accelerated void coalescence reduces spall strength monotonically with increasing shear strain, where a shear strain of 0.77% lowers the strength by 11.2%, and 1.39% by 30.2%. Numerical simulations reproduce the observed wave interactions, shear stress distribution, and damage morphology, confirming the shear-mediated twinning-damage scenario. These findings reveal the mechanism where the geometry-induced stress state governs deformation twinning, void evolution and the spall strength degradation, offering essential guidance for the design and safety evaluation of high-strength metals under complex dynamic loading.
- Open Access
- 10 February 2026
- Published by Elsevier in SSRN Electronic Journal
Crack monitoring and damage assessment of CFRP-confined corroded RC square columns under compressive loading using acoustic emission
This study investigates the damage evolution of CFRP-confined reinforced concrete (RC) square columns under compression, utilizing acoustic emission (AE) to monitor corrosion effects. Results indicate that increasing corrosion shifts failure modes from concrete crushing to reinforcement buckling and delamination, reducing peak and yield loads by 20% and 29% at 20% corrosion levels. AE analysis reveals that corrosion accelerates damage onset, prompting a shift toward low-frequency signals indicative of macroscopic cracking and interfacial debonding. Decreasing Ib-values highlight a transition from distributed microcracking to high-amplitude, brittle failure modes. Furthermore, severity (Sr) and historical index (HI) analyses demonstrate that while CFRP effectively delays failure in lightly corroded specimens, corrosion-induced bond deterioration significantly compromises confinement in severely corroded columns, leading to rapid instability. These findings underscore the critical impact of corrosion on confinement efficiency and validate AE monitoring for assessing damage progression.
- 10 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessCrack monitoring and damage assessment of CFRP-confined corroded RC square columns under compressive loading using acoustic emission
This study investigates the damage evolution of CFRP-confined reinforced concrete (RC) square columns under compression, utilizing acoustic emission (AE) to monitor corrosion effects. Results indicate that increasing corrosion shifts failure modes from concrete crushing to reinforcement buckling and delamination, reducing peak and yield loads by 20% and 29% at 20% corrosion levels. AE analysis reveals that corrosion accelerates damage onset, prompting a shift toward low-frequency signals indicative of macroscopic cracking and interfacial debonding. Decreasing Ib-values highlight a transition from distributed microcracking to high-amplitude, brittle failure modes. Furthermore, severity (Sr) and historical index (HI) analyses demonstrate that while CFRP effectively delays failure in lightly corroded specimens, corrosion-induced bond deterioration significantly compromises confinement in severely corroded columns, leading to rapid instability. These findings underscore the critical impact of corrosion on confinement efficiency and validate AE monitoring for assessing damage progression.
- 5 November 2025
- Published by Elsevier in Journal of Building Engineering
- Vol. 115
Study on building-building impact behavior induced by sideways collapse of a RC frame structure using shaking table test
- 5 November 2025
- Published by Elsevier in Journal of Building Engineering
- Vol. 115
Study on building-building impact behavior induced by sideways collapse of a RC frame structure using shaking table test
- 10 November 2023
- Published by Elsevier in Journal of Building Engineering
- Vol. 80
Progressive collapse resistance of RC beam-slab substructure under two-adjacent-edge-columns removal scenario
- 10 November 2023
- Published by Elsevier in Journal of Building Engineering
- Vol. 80
Progressive collapse resistance of RC beam-slab substructure under two-adjacent-edge-columns removal scenario
- 9 September 2023
- Published by Elsevier in Engineering Structures
- Vol. 295
Experimental studies on improving progressive collapse resistance of RC beam–column assemblies using kinked steel plates
- 9 September 2023
- Published by Elsevier in Engineering Structures
- Vol. 295
Experimental studies on improving progressive collapse resistance of RC beam–column assemblies using kinked steel plates