Masato Odagaki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Masato Odagaki has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Bumsuk Lee
Gunma University
4 shared publications - Keisuke Sasaki
Graduate School of Maebashi Institute of Technology
3 shared publications Naoto Noguchi
Gunma University Graduate School of Health Sciences, Maebashi, Japan
3 shared publicationsRyoto Akiyama
Gunma University Graduate School of Health Sciences, Maebashi, Japan
3 shared publications- Yuki Fujishige
Maebashi Institute of Technology
3 shared publications - Yutaka Kikuchi
Institute of Brain and Blood Vessels, Mihara Memorial Hospital, Isesaki 372-0006, Gunma, Japan
3 shared publications
Latest Publications
- 4 September 2026
- Published by Springer Nature in Spinal Cord
- p. 1-6
Kinematic characteristics of multi-directional reaching movement in degenerative cervical myelopathy
Study Design Prospective cross-sectional study. Objectives To objectively evaluate kinematic characteristics of multi-directional reaching movement in individuals with degenerative cervical myelopathy (DCM). Setting East Maebashi Orthopedic Hospital, Japan. Methods Twenty-five individuals with DCM participated in this study. Participants performed single- and multi-directional reaching tasks before and after cervical decompression surgery. Kinematic parameters, including Acceleration (ACC), Movement time, and Movement distance, were recorded in three-dimensional (3D) space during the two reaching tasks. Correlations between the improvement rates of kinematic parameters and other clinical tests were evaluated. Furthermore, a multiple stepwise regression analysis was performed to investigate the contribution of multi-directional reaching to the postoperative improvement of upper limb performance. Results Kinematic parameters during multi-directional reaching showed significant improvement after surgery. Multiple regression analysis revealed that improvement of upper limb performance was predicted by the improvement of ACC during multi-directional reaching (β = 0.50, p < 0.05) and the 10-second grip-and-release test (β = 0.49, p < 0.05), explaining 45% of variance. Conclusions Evaluation of multi-directional reaching movement, which more accurately reflects multi-joint coordination of the proximal arm, could serve as a valuable indicator for assessing postoperative recovery in reaching function in DCM. Moreover, these findings suggest that reaching function affects overall upper limb performance and the importance of separately assessing proximal and distal arm functions in individuals with DCM.
- 4 September 2026
- Published by Springer Nature in Spinal Cord
- p. 1-6
Kinematic characteristics of multi-directional reaching movement in degenerative cervical myelopathy
Study Design Prospective cross-sectional study. Objectives To objectively evaluate kinematic characteristics of multi-directional reaching movement in individuals with degenerative cervical myelopathy (DCM). Setting East Maebashi Orthopedic Hospital, Japan. Methods Twenty-five individuals with DCM participated in this study. Participants performed single- and multi-directional reaching tasks before and after cervical decompression surgery. Kinematic parameters, including Acceleration (ACC), Movement time, and Movement distance, were recorded in three-dimensional (3D) space during the two reaching tasks. Correlations between the improvement rates of kinematic parameters and other clinical tests were evaluated. Furthermore, a multiple stepwise regression analysis was performed to investigate the contribution of multi-directional reaching to the postoperative improvement of upper limb performance. Results Kinematic parameters during multi-directional reaching showed significant improvement after surgery. Multiple regression analysis revealed that improvement of upper limb performance was predicted by the improvement of ACC during multi-directional reaching (β = 0.50, p < 0.05) and the 10-second grip-and-release test (β = 0.49, p < 0.05), explaining 45% of variance. Conclusions Evaluation of multi-directional reaching movement, which more accurately reflects multi-joint coordination of the proximal arm, could serve as a valuable indicator for assessing postoperative recovery in reaching function in DCM. Moreover, these findings suggest that reaching function affects overall upper limb performance and the importance of separately assessing proximal and distal arm functions in individuals with DCM.
- Open Access
- 21 January 2026
- Published by Springer Nature in Research Square
Kinematic characteristics of multi-directional reaching movement in degenerative cervical myelopathy
Study Design: Prospective cross-sectional study Objectives: To objectively evaluate kinematic characteristics of multi-directional reaching movement in individuals with degenerative cervical myelopathy (DCM). Setting: East Maebashi Orthopedic Hospital, Japan. Methods: Twenty-five individuals with DCM participated in this study. Participants performed single- and multi-directional reaching tasks before and after cervical decompression surgery. Kinematic parameters, including Acceleration (ACC), Movement time, and Movement distance, were recorded in three-dimensional (3D) space during the two reaching tasks. Correlations between the improvement rates of kinematic parameters and other clinical tests were evaluated. Furthermore, a multiple stepwise regression analysis was performed to investigate the contribution of multi-directional reaching to the postoperative improvement of upper limb performance. Results: The 3D trajectories during multi-directional reaching became smoother with reduced variability after surgery, and significant postoperative improvements were observed in kinematic parameters. Multiple regression analysis revealed that improvement of upper limb performance was predicted by the improvement of ACC during multi-directional reaching (β = 0.50, p < 0.05) and the 10-second grip-and-release test (β = 0.49, p < 0.05), explaining 45% of variance. Conclusions: Evaluation of multi-directional reaching movement, which more accurately reflects multi-joint coordination of the proximal arm, could serve as a valuable indicator for assessing postoperative recovery in reaching function in DCM. Moreover, these findings suggest that reaching function affects overall upper limb performance and the importance of separately assessing proximal and distal arm functions in individuals with DCM.
- 21 January 2026
- Published by Springer Nature in Research Square
Open AccessKinematic characteristics of multi-directional reaching movement in degenerative cervical myelopathy
Study Design: Prospective cross-sectional study Objectives: To objectively evaluate kinematic characteristics of multi-directional reaching movement in individuals with degenerative cervical myelopathy (DCM). Setting: East Maebashi Orthopedic Hospital, Japan. Methods: Twenty-five individuals with DCM participated in this study. Participants performed single- and multi-directional reaching tasks before and after cervical decompression surgery. Kinematic parameters, including Acceleration (ACC), Movement time, and Movement distance, were recorded in three-dimensional (3D) space during the two reaching tasks. Correlations between the improvement rates of kinematic parameters and other clinical tests were evaluated. Furthermore, a multiple stepwise regression analysis was performed to investigate the contribution of multi-directional reaching to the postoperative improvement of upper limb performance. Results: The 3D trajectories during multi-directional reaching became smoother with reduced variability after surgery, and significant postoperative improvements were observed in kinematic parameters. Multiple regression analysis revealed that improvement of upper limb performance was predicted by the improvement of ACC during multi-directional reaching (β = 0.50, p < 0.05) and the 10-second grip-and-release test (β = 0.49, p < 0.05), explaining 45% of variance. Conclusions: Evaluation of multi-directional reaching movement, which more accurately reflects multi-joint coordination of the proximal arm, could serve as a valuable indicator for assessing postoperative recovery in reaching function in DCM. Moreover, these findings suggest that reaching function affects overall upper limb performance and the importance of separately assessing proximal and distal arm functions in individuals with DCM.
- Open Access
Development of a Robot-Assisted TMS Localization System Using Dual Capacitive Sensors for Coil Tilt Detection
Transcranial Magnetic Stimulation (TMS) is a non-invasive technique for neurological research and therapy, but its effectiveness depends on accurate and stable coil placement. Manual localization based on anatomical landmarks is time-consuming and operator-dependent, while state-of-the-art robotic and neuronavigation systems achieve high accuracy using optical tracking with head-mounted markers and infrared cameras, at the cost of increased system complexity and setup burden. This study presents a cost-effective, markerless robotic-assisted TMS system that combines a 3D depth camera and textile capacitive sensors to assist coil localization and contact control. Facial landmarks detected by the depth camera are used to estimate the motor cortex (C3) location without external tracking markers, while a dual textile-sensor suspension provides compliant “soft-landing” behavior, contact confirmation, and coil-tilt estimation. Experimental evaluation with five participants showed reliable C3 targeting with valid motor evoked potentials (MEPs) obtained in most trials after initial calibration, and tilt-verification experiments revealed that peak MEP amplitudes occurred near balanced sensor readings in 12 of 15 trials (80%). The system employs a collaborative robot designed in accordance with international human–robot interaction safety standards, including force-limited actuation and monitored stopping. These results suggest that the proposed approach can improve the accessibility, safety, and consistency of TMS procedures while avoiding the complexity of conventional optical tracking systems.
Open AccessDevelopment of a Robot-Assisted TMS Localization System Using Dual Capacitive Sensors for Coil Tilt Detection
Transcranial Magnetic Stimulation (TMS) is a non-invasive technique for neurological research and therapy, but its effectiveness depends on accurate and stable coil placement. Manual localization based on anatomical landmarks is time-consuming and operator-dependent, while state-of-the-art robotic and neuronavigation systems achieve high accuracy using optical tracking with head-mounted markers and infrared cameras, at the cost of increased system complexity and setup burden. This study presents a cost-effective, markerless robotic-assisted TMS system that combines a 3D depth camera and textile capacitive sensors to assist coil localization and contact control. Facial landmarks detected by the depth camera are used to estimate the motor cortex (C3) location without external tracking markers, while a dual textile-sensor suspension provides compliant “soft-landing” behavior, contact confirmation, and coil-tilt estimation. Experimental evaluation with five participants showed reliable C3 targeting with valid motor evoked potentials (MEPs) obtained in most trials after initial calibration, and tilt-verification experiments revealed that peak MEP amplitudes occurred near balanced sensor readings in 12 of 15 trials (80%). The system employs a collaborative robot designed in accordance with international human–robot interaction safety standards, including force-limited actuation and monitored stopping. These results suggest that the proposed approach can improve the accessibility, safety, and consistency of TMS procedures while avoiding the complexity of conventional optical tracking systems.
- Open Access
- 10 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Translational Engineering in Health and Medicine
- Vol. 11, 460-468
Development of an Evaluation System for Transfer Care Skills Using Embroidered Body Pressure and Proximity Sensor
Objective: It is important to improve caregiving skills to help reduce the strain on inexperienced caregivers. Previous studies on quantifying caregiving skills have predominantly relied on expensive equipment, such as motion-capture systems with multiple infrared cameras or acceleration sensors. To overcome the cost and space limitations of existing systems, we developed a simple evaluation system for transfer care skills that uses capacitive sensors composed of conductive embroidery fibers. The proposed system can be developed with a few thousand US dollars. Method: The developed evaluation system was used to compare the seating position and velocity of a care recipient during transfers from a nursing-care bed to a wheelchair between groups of inexperienced and expert caregivers. To validate the proposed system, we compare the motion data measured by our system and the data obtained from a conventional three-dimensional motion-capture system and force plate. Results: We analyze the relationship between changes in the center of pressure (CoP) recorded by the force plate and the center of gravity (CoG) obtained by the developed system. Evidently, the changes in CoP have a relation with the CoG. We show that the actual seating speed (vz) measured by the motion-capture system is related to the speed coefficient calculated from our sensor output. A significant difference exists in Vz between the inexperienced group and the physical therapists/occupational therapists’ group. Conclusions: The proposed system can effectively estimate a caregiver’s skill level in transferring patients from a bed to a wheelchair in terms of the seating position and velocity.
- 10 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Translational Engineering in Health and Medicine
- Vol. 11, 460-468
Open AccessDevelopment of an Evaluation System for Transfer Care Skills Using Embroidered Body Pressure and Proximity Sensor
Objective: It is important to improve caregiving skills to help reduce the strain on inexperienced caregivers. Previous studies on quantifying caregiving skills have predominantly relied on expensive equipment, such as motion-capture systems with multiple infrared cameras or acceleration sensors. To overcome the cost and space limitations of existing systems, we developed a simple evaluation system for transfer care skills that uses capacitive sensors composed of conductive embroidery fibers. The proposed system can be developed with a few thousand US dollars. Method: The developed evaluation system was used to compare the seating position and velocity of a care recipient during transfers from a nursing-care bed to a wheelchair between groups of inexperienced and expert caregivers. To validate the proposed system, we compare the motion data measured by our system and the data obtained from a conventional three-dimensional motion-capture system and force plate. Results: We analyze the relationship between changes in the center of pressure (CoP) recorded by the force plate and the center of gravity (CoG) obtained by the developed system. Evidently, the changes in CoP have a relation with the CoG. We show that the actual seating speed (vz) measured by the motion-capture system is related to the speed coefficient calculated from our sensor output. A significant difference exists in Vz between the inexperienced group and the physical therapists/occupational therapists’ group. Conclusions: The proposed system can effectively estimate a caregiver’s skill level in transferring patients from a bed to a wheelchair in terms of the seating position and velocity.
- 1 May 2022
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Electronics, Information and Systems
- Vol. 142 (5) , 563-568
Comparison of Reaching Motion between Elderly and Young adults Using an Electronic Evaluation System of Upper Extremity Function
The purpose of this study was to assess the influence of ageing on reaching motion using a simple and quantitative method. An Electronic Evaluation System of Upper Extremity Function incorporating a motion sensor was used to monitor kinematic changes during a whack-a-mole type task. Sixteen healthy elderly adults (3 males and 13 females, mean age 78.8±6.0 years) and nineteen young adults (3 males and 16 females, mean age 22.1±2.8 years) participated in this study. The participants were asked to continue tapping 16 targets randomly presented on the screen. Based on the kinematic data, the tremor value, spatial travel distance, tapping time, and maximal spatial acceleration were calculated. Differences between elderly and young adults were tested using unpaired-t test. Significant differences were observed in all kinematic parameters, suggesting decreased reaching motion in elderly adults. Moreover, overall positive correlations between parameters were found. Our results suggest that kinematic parameters calculated from the motion sensor technology could be useful to evaluate reaching motion quantitatively and simply.
- 1 May 2022
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Electronics, Information and Systems
- Vol. 142 (5) , 563-568
Comparison of Reaching Motion between Elderly and Young adults Using an Electronic Evaluation System of Upper Extremity Function
The purpose of this study was to assess the influence of ageing on reaching motion using a simple and quantitative method. An Electronic Evaluation System of Upper Extremity Function incorporating a motion sensor was used to monitor kinematic changes during a whack-a-mole type task. Sixteen healthy elderly adults (3 males and 13 females, mean age 78.8±6.0 years) and nineteen young adults (3 males and 16 females, mean age 22.1±2.8 years) participated in this study. The participants were asked to continue tapping 16 targets randomly presented on the screen. Based on the kinematic data, the tremor value, spatial travel distance, tapping time, and maximal spatial acceleration were calculated. Differences between elderly and young adults were tested using unpaired-t test. Significant differences were observed in all kinematic parameters, suggesting decreased reaching motion in elderly adults. Moreover, overall positive correlations between parameters were found. Our results suggest that kinematic parameters calculated from the motion sensor technology could be useful to evaluate reaching motion quantitatively and simply.
- Open Access
- 25 June 2021
- Published by International Association of Online Engineering (IAOE) in International Journal of Online and Biomedical Engineering (iJOE)
- Vol. 17 (06) , 87-97
EEG Coherence Analysis for Suppression of MEP Amplitude Variability in TMS
Transcranial magnetic stimulation (TMS) is a non-invasive stimulation method for cortical neurons. When TMS is delivered to the primary motor cortex (M1), motor evoked potentials can be measured in electromyograms for the peripheral muscle. However, the motor-evoked potential (MEP) amplitudes measured by stimulations for M1 fluctuated from trial to trial. MEP fluctuations are caused by changes in cortical excitability. We hypothesized that MEP variability could be suppressed with application of TMS when cortical excitability was stable. Thus, we developed a TMS system to suppress MEP amplitude variabilities. We used electroencephalographic (EEG) online measurements with coherence analysis to obtain the similarity of cortical excitabilities. The system enables us to trigger TMS if the EEGs measured from the two channels have a high similarity in the frequency domain. In this study, we found that the suppression of MEP fluctuation was dependent on the state of cortical excitability obtained by EEG coherence analysis.
- 25 June 2021
- Published by International Association of Online Engineering (IAOE) in International Journal of Online and Biomedical Engineering (iJOE)
- Vol. 17 (06) , 87-97
Open AccessEEG Coherence Analysis for Suppression of MEP Amplitude Variability in TMS
Transcranial magnetic stimulation (TMS) is a non-invasive stimulation method for cortical neurons. When TMS is delivered to the primary motor cortex (M1), motor evoked potentials can be measured in electromyograms for the peripheral muscle. However, the motor-evoked potential (MEP) amplitudes measured by stimulations for M1 fluctuated from trial to trial. MEP fluctuations are caused by changes in cortical excitability. We hypothesized that MEP variability could be suppressed with application of TMS when cortical excitability was stable. Thus, we developed a TMS system to suppress MEP amplitude variabilities. We used electroencephalographic (EEG) online measurements with coherence analysis to obtain the similarity of cortical excitabilities. The system enables us to trigger TMS if the EEGs measured from the two channels have a high similarity in the frequency domain. In this study, we found that the suppression of MEP fluctuation was dependent on the state of cortical excitability obtained by EEG coherence analysis.
- Open Access
- 7 June 2021
- Published by JMIR Publications Inc. in JMIR Biomedical Engineering
- Vol. 6 (2) , e28902
A Transcranial Magnetic Stimulation Trigger System for Suppressing Motor-Evoked Potential Fluctuation Using Electroencephalogram Coherence Analysis: Algorithm Development and Validation Study
Background: Transcranial magnetic stimulation (TMS), when applied over the primary motor cortex, elicits a motor-evoked potential (MEP) in electromyograms measured from peripheral muscles. MEP amplitude has often been observed to fluctuate trial to trial, even with a constant stimulus. Many factors cause MEP fluctuations in TMS. One of the primary factors is the weak stationarity and instability of cortical activity in the brain, from which we assumed MEP fluctuations originate. We hypothesized that MEP fluctuations are suppressed when TMS is delivered to the primary motor cortex at a time when several electroencephalogram (EEG) channels measured on the scalp are highly similar in the frequency domain. Objective: We developed a TMS triggering system to suppress MEP fluctuations using EEG coherence analysis, which was performed to detect the EEG signal similarity between the 2 channels in the frequency domain. Methods: Seven healthy adults participated in the experiment to confirm whether the TMS trigger system works adequately, and the mean amplitude and coefficient of the MEP variation were recorded and compared with the values obtained during the control task. We also determined the experimental time under each condition and verified whether it was within the predicted time. Results: The coefficient of variation of MEP amplitude decreased in 5 of the 7 participants, and significant differences (P=.02) were confirmed in 2 of the participants according to an F test. The coefficient of variation of the experimental time required for each stimulus after threshold modification was less than that without threshold modification, and a significant difference (P<.001) was confirmed by performing an F test. Conclusions: We found that MEP could be suppressed using the system developed in this study and that the TMS trigger system could also stabilize the experimental time by changing the triggering threshold automatically.
- 7 June 2021
- Published by JMIR Publications Inc. in JMIR Biomedical Engineering
- Vol. 6 (2) , e28902
Open AccessA Transcranial Magnetic Stimulation Trigger System for Suppressing Motor-Evoked Potential Fluctuation Using Electroencephalogram Coherence Analysis: Algorithm Development and Validation Study
Background: Transcranial magnetic stimulation (TMS), when applied over the primary motor cortex, elicits a motor-evoked potential (MEP) in electromyograms measured from peripheral muscles. MEP amplitude has often been observed to fluctuate trial to trial, even with a constant stimulus. Many factors cause MEP fluctuations in TMS. One of the primary factors is the weak stationarity and instability of cortical activity in the brain, from which we assumed MEP fluctuations originate. We hypothesized that MEP fluctuations are suppressed when TMS is delivered to the primary motor cortex at a time when several electroencephalogram (EEG) channels measured on the scalp are highly similar in the frequency domain. Objective: We developed a TMS triggering system to suppress MEP fluctuations using EEG coherence analysis, which was performed to detect the EEG signal similarity between the 2 channels in the frequency domain. Methods: Seven healthy adults participated in the experiment to confirm whether the TMS trigger system works adequately, and the mean amplitude and coefficient of the MEP variation were recorded and compared with the values obtained during the control task. We also determined the experimental time under each condition and verified whether it was within the predicted time. Results: The coefficient of variation of MEP amplitude decreased in 5 of the 7 participants, and significant differences (P=.02) were confirmed in 2 of the participants according to an F test. The coefficient of variation of the experimental time required for each stimulus after threshold modification was less than that without threshold modification, and a significant difference (P<.001) was confirmed by performing an F test. Conclusions: We found that MEP could be suppressed using the system developed in this study and that the TMS trigger system could also stabilize the experimental time by changing the triggering threshold automatically.
- Open Access
- 18 March 2021
- Published by JMIR Publications Inc. in JMIR Preprints
A Transcranial Magnetic Stimulation Trigger System for Suppressing Motor-Evoked Potential Fluctuation Using Electroencephalogram Coherence Analysis: Algorithm Development and Validation Study (Preprint)
BACKGROUND Transcranial magnetic stimulation (TMS), when applied over the primary motor cortex, elicits a motor-evoked potential (MEP) in electromyograms measured from peripheral muscles. MEP amplitude has often been observed to fluctuate trial to trial, even with a constant stimulus. Many factors cause MEP fluctuations in TMS. One of the primary factors is the weak stationarity and instability of cortical activity in the brain, from which we assumed MEP fluctuations originate. We hypothesized that MEP fluctuations are suppressed when TMS is delivered to the primary motor cortex at a time when several electroencephalogram (EEG) channels measured on the scalp are highly similar in the frequency domain. OBJECTIVE We developed a TMS triggering system to suppress MEP fluctuations using EEG coherence analysis, which was performed to detect the EEG signal similarity between the 2 channels in the frequency domain. METHODS Seven healthy adults participated in the experiment to confirm whether the TMS trigger system works adequately, and the mean amplitude and coefficient of the MEP variation were recorded and compared with the values obtained during the control task. We also determined the experimental time under each condition and verified whether it was within the predicted time. RESULTS The coefficient of variation of MEP amplitude decreased in 5 of the 7 participants, and significant differences (P=.02) were confirmed in 2 of the participants according to an F test. The coefficient of variation of the experimental time required for each stimulus after threshold modification was less than that without threshold modification, and a significant difference (P<.001) was confirmed by performing an F test. CONCLUSIONS We found that MEP could be suppressed using the system developed in this study and that the TMS trigger system could also stabilize the experimental time by changing the triggering threshold automatically.
- 18 March 2021
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessA Transcranial Magnetic Stimulation Trigger System for Suppressing Motor-Evoked Potential Fluctuation Using Electroencephalogram Coherence Analysis: Algorithm Development and Validation Study (Preprint)
BACKGROUND Transcranial magnetic stimulation (TMS), when applied over the primary motor cortex, elicits a motor-evoked potential (MEP) in electromyograms measured from peripheral muscles. MEP amplitude has often been observed to fluctuate trial to trial, even with a constant stimulus. Many factors cause MEP fluctuations in TMS. One of the primary factors is the weak stationarity and instability of cortical activity in the brain, from which we assumed MEP fluctuations originate. We hypothesized that MEP fluctuations are suppressed when TMS is delivered to the primary motor cortex at a time when several electroencephalogram (EEG) channels measured on the scalp are highly similar in the frequency domain. OBJECTIVE We developed a TMS triggering system to suppress MEP fluctuations using EEG coherence analysis, which was performed to detect the EEG signal similarity between the 2 channels in the frequency domain. METHODS Seven healthy adults participated in the experiment to confirm whether the TMS trigger system works adequately, and the mean amplitude and coefficient of the MEP variation were recorded and compared with the values obtained during the control task. We also determined the experimental time under each condition and verified whether it was within the predicted time. RESULTS The coefficient of variation of MEP amplitude decreased in 5 of the 7 participants, and significant differences (P=.02) were confirmed in 2 of the participants according to an F test. The coefficient of variation of the experimental time required for each stimulus after threshold modification was less than that without threshold modification, and a significant difference (P<.001) was confirmed by performing an F test. CONCLUSIONS We found that MEP could be suppressed using the system developed in this study and that the TMS trigger system could also stabilize the experimental time by changing the triggering threshold automatically.
- 12 May 2020
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 15 (7) , 1065-1069
Development of a sensor with a conductive textile for detecting decubitus ulcers
The present paper describes the design and evaluation results of a sensor for measuring body pressure and sweat volume using conductive fibers. Pressure ulcers that develop from staying in the same posture for a long time are a serious problem in nursing care. The main causes of pressure ulcers are blockage of capillaries due to body pressure and skin structure degeneration due to sweat. To quantify the causes of pressure ulcers, Mengeng Liu et al. have developed a sensitive (14.4 kPa−1) pressure sensor using conductive fibers with excellent cleaning and flexibility. However, a conductive fiber sensor that focuses on both body pressure and sweating has not yet been established. Therefore, in the present research, we made a sensor that can measure body pressure and sweat volume with only fibers and evaluated the performance of the proposed method. The fabricated sensor is a parallel plate capacitive sensor made of two conductive fibers that sandwich an insulating cloth. When body pressure is applied, the distance between two parallel conductive fibers increases, and when sweat is applied, the dielectric constant of the fabric changes, increasing the capacitance of the sensor. Capacitance change can be evaluated by peak holding the output of the AC bridge circuit. Through an evaluation experiment using a vise and a constant temperature and constant‐humidity chamber, the fabricated sensor was confirmed to be able to measure a pressure change of 10 mmHg and a humidity change of 10%. This sensor, which can evaluate pressure and humidity (amount of adhering water) at the same time and at low cost, contributes to reducing the burden of nursing care. © 2020 Institute of Electrical Engineers of Japan. Published by John Wiley & Sons, Inc.
- 12 May 2020
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 15 (7) , 1065-1069
Development of a sensor with a conductive textile for detecting decubitus ulcers
The present paper describes the design and evaluation results of a sensor for measuring body pressure and sweat volume using conductive fibers. Pressure ulcers that develop from staying in the same posture for a long time are a serious problem in nursing care. The main causes of pressure ulcers are blockage of capillaries due to body pressure and skin structure degeneration due to sweat. To quantify the causes of pressure ulcers, Mengeng Liu et al. have developed a sensitive (14.4 kPa−1) pressure sensor using conductive fibers with excellent cleaning and flexibility. However, a conductive fiber sensor that focuses on both body pressure and sweating has not yet been established. Therefore, in the present research, we made a sensor that can measure body pressure and sweat volume with only fibers and evaluated the performance of the proposed method. The fabricated sensor is a parallel plate capacitive sensor made of two conductive fibers that sandwich an insulating cloth. When body pressure is applied, the distance between two parallel conductive fibers increases, and when sweat is applied, the dielectric constant of the fabric changes, increasing the capacitance of the sensor. Capacitance change can be evaluated by peak holding the output of the AC bridge circuit. Through an evaluation experiment using a vise and a constant temperature and constant‐humidity chamber, the fabricated sensor was confirmed to be able to measure a pressure change of 10 mmHg and a humidity change of 10%. This sensor, which can evaluate pressure and humidity (amount of adhering water) at the same time and at low cost, contributes to reducing the burden of nursing care. © 2020 Institute of Electrical Engineers of Japan. Published by John Wiley & Sons, Inc.
- 1 January 2016
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Electronics, Information and Systems
- Vol. 136 (12) , 1791-1796
Study on Corticospinal Excitability during Passive Symmetry and Asymmetry Finger Movements by TMS
Bilateral information in primary motor cortices of human cerebral hemispheres is needed to produce simultaneous bilateral limb movement. The corpus callosum connecting homologous areas of cortex between the hemispheres is an important area to exert bilateral finger movements. It is unclear that the movement state of both fingers influences corticospinal excitability involving in contralateral movement. We measured corticospinal excitability during passive movement of both fingers using transcranial magnetic stimulation (TMS) on the primary motor cortex. The subjects performed passive movement of fingers using servomotors. TMS was applied at the two movement states of maximum flexion and extension position on metacarpophalangeal joint (MP joint) of dominant index finger, respectively. There were three kinds of movement task of symmetry, asymmetry and one-finger movements in this experiment. In one-finger movement task, the highest motor evoked potential (MEP) in electromyogram was measured with TMS timing of maximum extension of MP joint angle. Moreover, MEP with maximum extension of MP joint was lowest in symmetry movement task, but the MEP was conversely lowest with maximum flexion in asymmetry movement task. These results suggested that MEP depended on MP joint angle and the corticospinal excitability was inhibited when contralateral MP joint angle was with maximum extension.
- 1 January 2016
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Electronics, Information and Systems
- Vol. 136 (12) , 1791-1796
Study on Corticospinal Excitability during Passive Symmetry and Asymmetry Finger Movements by TMS
Bilateral information in primary motor cortices of human cerebral hemispheres is needed to produce simultaneous bilateral limb movement. The corpus callosum connecting homologous areas of cortex between the hemispheres is an important area to exert bilateral finger movements. It is unclear that the movement state of both fingers influences corticospinal excitability involving in contralateral movement. We measured corticospinal excitability during passive movement of both fingers using transcranial magnetic stimulation (TMS) on the primary motor cortex. The subjects performed passive movement of fingers using servomotors. TMS was applied at the two movement states of maximum flexion and extension position on metacarpophalangeal joint (MP joint) of dominant index finger, respectively. There were three kinds of movement task of symmetry, asymmetry and one-finger movements in this experiment. In one-finger movement task, the highest motor evoked potential (MEP) in electromyogram was measured with TMS timing of maximum extension of MP joint angle. Moreover, MEP with maximum extension of MP joint was lowest in symmetry movement task, but the MEP was conversely lowest with maximum flexion in asymmetry movement task. These results suggested that MEP depended on MP joint angle and the corticospinal excitability was inhibited when contralateral MP joint angle was with maximum extension.